    							LOGIQ 5 Basic User Manual 15-1
    Direction 2300002-100 Rev. 2
    Chapter 15
    Recording Images
    Describes how to record images.  
    						
    							Recording Images
    15-2 LOGIQ 5 Basic User Manual
    Direction 2300002-100 Rev. 2
    Connectivity
    Overview
    A typical workflow for connectivity might be as follows (this setup 
    varies by each user setup): 
    •  Select the dataflow, worklist for example. 
    •  Start a new exam. Select the patient. 
    •  Perform the patient scan.
    •  Store images as multi-frame CINE Loops and Raw DICOM 
    data via the P1 button. 
    •  Store secondary capture for DICOM print via P2. 
    •  Store images to the color printer via P3. 
    •  Store images to the black and white printer via P4. 
    •  Check the DICOM Job Spooler via F4 to verify delivery. 
    •  End the exam. 
    •  Permanently store images via the Patient menu.  
    						
    							Connectivity
    LOGIQ 5 Basic User Manual 15-3
    Direction 2300002-100 Rev. 2
    Overview (continued)
    Dataflow combines archive, data, DICOM, and onboard records 
    into one coherent workflow. Destination devices are configured 
    and assigned to P1-P4 print buttons. You select the appropriate 
    dataflow (Portable, etc.) according to your requirements. You 
    manage the patient database (local, shared, or via a worklist 
    broker). 
    •  DO NOT use the internal hard drive for long-term image 
    storage. Daily backup is recommended. MOD or CD storage 
    is recommended for image archive.
    NOTE:  DICOM images are stored to MOD separately from patient 
    data, which also needs to be backed up to a dedicated 
    database-formatted MOD. 
    •  You need to set up a protocol for locating images stored to 
    external storage media for easy recall
    •  GE Medical Systems IS NOT responsible for lost data if you 
    do not follow suggested back-up procedures. GE Medical 
    systems WILL NOT aid in the recovery of lost data. 
    Refer to the Customizing Your System chapter for instructions 
    on seting up your system’s connectivity.  
    						
    							Recording Images
    15-4 LOGIQ 5 Basic User Manual
    Direction 2300002-100 Rev. 2
    Adding Devices
    To add a destination device (printer, worklist server, etc.) to this 
    system, see Chapter 16. 
    To verify a DICOM device, see Chapter 16.
    Adding a Dataflow
    To add a new dataflow to this system, see Chapter 16.
    Adding Devices to a Print Button
    To add devices/dataflows to a print button (P1 through P4), see 
    Chapter 16.
    Formatting Removable Media
    To format removable media, see Chapter 16.
    Using the DICOM Spooler
    To monitor/control DICOM jobs, press F4. You can view, resend, 
    redirect, and delete images from the DICOM spooler by 
    selecting a job, then specifying the action to be performed on 
    this job. 
    Troubleshooting using Views
    To troubleshoot connectivity on this system, see Chapter 16.
    To verify that a service is connected to the network, see Chapter 
    16. 
    						
    							Connectivity
    LOGIQ 5 Basic User Manual 15-5
    Direction 2300002-100 Rev. 2
    Portable Exams Using the DICOM Worklist Broker
    Here are the steps to follow when doing a portable exam: 
    1.  Set up a dataflow called ‘Portable Exam’. The DICOM 
    Worklist must be set up as the primary input device. DICOM 
    Image Store must be set up as the primary output. 
     Figure 15-1. Portable Exam with Worklist Dataflow Setup Example 
    						
    							Recording Images
    15-6 LOGIQ 5 Basic User Manual
    Direction 2300002-100 Rev. 2
    Portable Exams Using the DICOM Worklist Broker (continued)
    2.  Define a print key for DICOM print. 
     Figure 15-2. DICOM Print Setup Example 
    						
    							Connectivity
    LOGIQ 5 Basic User Manual 15-7
    Direction 2300002-100 Rev. 2
    Portable Exams Using the DICOM Worklist Broker (continued)
    3. Login. 
     Figure 15-3. Login Pop-up Menu
    4.  On the Patient menu, select Portable with Worklist as this 
    exam’s Dataflow. 
     Figure 15-4. Selecting the Portable Exam Dataflow on the New Patient Menu 
    						
    							Recording Images
    15-8 LOGIQ 5 Basic User Manual
    Direction 2300002-100 Rev. 2
    Portable Exams Using the DICOM Worklist Broker (continued)
    5.  Select the portable exam patient. 
     Figure 15-5. Selecting the Portable Exam Patient on the New Patient Menu
    6.  Select the appropriate choice in the Warning message. 
     Figure 15-6. New Patient Query 
    						
    							Connectivity
    LOGIQ 5 Basic User Manual 15-9
    Direction 2300002-100 Rev. 2
    Portable Exams Using the DICOM Worklist Broker (continued)
    7.  Press On/Off. Answer ‘Shutdown’ to the System - Exit pop-
    up message. 
     Figure 15-7. System Power Down Menu
    8.  Transport the system according to user manual instructions 
    to the portable exam site.  
    						
    							Recording Images
    15-10 LOGIQ 5 Basic User Manual
    Direction 2300002-100 Rev. 2
    Portable Exams Using the DICOM Worklist Broker (continued)
    9.  Press Standby (On/Off) to power on the system. The 
    patient’s exam is displayed on the screen. 
     Figure 15-8. Patient’s Exam
    10.  Answer ‘Cont./End Exam’ to the Question pop-up message. 
     Figure 15-9. Continue Current Exam Question Pop-up Menu 
    						