Measurement and Calculation Setup LOGIQ 5 Basic User Manual 7-21 Direction 2300002-100 Rev. 2 Selecting a study or measurement (continued) To select a folder or measurement: 1. Move the Trackball to the Selection menu and highlight the folder or measurement. 2. Press Set. • If you selected a folder, the system displays the folder in the Folder section of the Measurement & Analysis screen. • If you selected a measurement, the system displays the measurement in the Measurement section of the Measurement & Analysis screen. NOTE: Items must be selected in the Available folders and measurements list to be in the Selection menu. To move or change an item that is in the Available folders and measurements list but not in the Selection menu, move the Trackball to the check box for the item, and press Set. The item is now listed in the Selection menu.+ Figure 7-10. Available folders and measurements check boxes
General Measurements and Calculations 7-22 LOGIQ 5 Basic User Manual Direction 2300002-100 Rev. 2 Using folders When you select a folder in the Selection menu, the system displays all folders and measurements that are in the folder. A folder can indicate a study, or can indicate a measurement group that contains related measurements. For example, a calculation such as OB Amniotic Fluid Index (AFI) requires four measurements, one of each quadrant. The AFI folder contains four measurements. Figure 7-11. AFI Folder
Measurement and Calculation Setup LOGIQ 5 Basic User Manual 7-23 Direction 2300002-100 Rev. 2 Specifying Which Measurements Go in a Study or Folder The Folder section of the Measurement & Analysis screen has two lists of folders and measurements. This is where you specify which items go in a study or folder. • Available folders and measurements. The left list contains all possible folders and measurements for the selected study or folder. • Measure & Study. The right list has all folders and measurements currently selected for the study or folder. These are selected from the Available folders and measurements list. These are the folders and measurements you see when you are scanning and choose an exam category. This also defines where the folder or measurement is located on the Touch Panel, based on the number in this list.
General Measurements and Calculations 7-24 LOGIQ 5 Basic User Manual Direction 2300002-100 Rev. 2 Specifying Which Measurements Go in a Study or Folder (continued) To add an item to the Measure & Study list: 1. In the Measure & Study list, move the Trackball to highlight where you want to put the item, and press Set. Figure 7-12. Measure & Study list: Select position
Measurement and Calculation Setup LOGIQ 5 Basic User Manual 7-25 Direction 2300002-100 Rev. 2 Specifying Which Measurements Go in a Study or Folder (continued) 2. Move the Trackball to highlight an item in the Available folders and measurements list, and press Set. Figure 7-13. Available folders and measurements list: Select item
General Measurements and Calculations 7-26 LOGIQ 5 Basic User Manual Direction 2300002-100 Rev. 2 Specifying Which Measurements Go in a Study or Folder (continued) 3. Select the arrow between the lists.The item is copied to the Measure & Study list. The selected item is now displayed in the Touch Panel and the Summary Window. See the Touch Panel in Figure 7-15. Figure 7-14. Measure & Study list: New item added
Measurement and Calculation Setup LOGIQ 5 Basic User Manual 7-27 Direction 2300002-100 Rev. 2 Specifying Which Measurements Go in a Study or Folder (continued) Figure 7-15. Touch Panel for RV/LV Cardiac folder: IVSd measurement added NOTE: If an item is already in the Measure & Study list, the system does not allow you to add it again. To move an item within the Measure & Study list, See ‘Moving items in the Touch Panel’ for more information..
General Measurements and Calculations 7-28 LOGIQ 5 Basic User Manual Direction 2300002-100 Rev. 2 Specifying Which Measurements Go in a Study or Folder (continued) Touch Panel positions Each Touch Panel has 16 positions, four across and four down. The items in the first row across are numbered 1–4, in the second row 5–8, and so on. See Figure 7-16 and Figure 7-17. These figures show the OB/GYN Vessel Touch Panel and the Measurement & Analysis screen for the OB/GYN Vessel. The numbers are shown in the Measure & Study list in the Measurement & Analysis screen. For example, the second row in the Touch Panel shows Prox, Aorta, Umbilical, and Placenta. In the Measurement & Analysis screen, the Measure & Study list shows these as number 5–8. Figure 7-16. Touch Panel for OB-GYN Vessel study
Measurement and Calculation Setup LOGIQ 5 Basic User Manual 7-29 Direction 2300002-100 Rev. 2 Touch Panel positions (continued) Figure 7-17. Measurement & Analysis: OB/GYN Vessel
General Measurements and Calculations 7-30 LOGIQ 5 Basic User Manual Direction 2300002-100 Rev. 2 Moving items in the Touch Panel To move items that are in the Touch Panel, you move them in the Measure & Study list. 1. Move the Trackball to highlight an item in the Measure & Study list. 2. Select the up or down arrow. The item is displayed at the selected position in the Touch Panel. NOTE: Some items cannot be moved. For example, Worksheet Display and Page Change are in the same place on each Touch Panel.