    							LOGIQ 5 Basic User Manual 3-1
    Direction 2300002-100 Rev. 2
    Chapter 3
    Preparing the System for Use
    Describes the site requirements, console overview, 
    system positioning/transporting, powering on the 
    system, adjusting the display monitor, probes and 
    operator controls. 
    						
    							Preparing the System for Use
    3-2 LOGIQ 5 Basic User Manual
    Direction 2300002-100 Rev. 2
    Site Requirements
    Introduction
    NOTE:  Only qualified physicians or sonographers should perform 
    ultrasound scanning on human subjects for medical diagnostic 
    reasons. Request training, if needed.
    Do not attempt to install the system alone. General Electric, 
    Affiliate, or Distributor Field Engineers and Application 
    Specialists will install and setup the system.  See ‘Contact 
    Information’ for more information.
    The LOGIQ 5 does not contain any operator serviceable internal 
    components. Ensure that unauthorized personnel do not tamper 
    with the unit.
    Perform regular preventive maintenance. See ‘System Care and 
    Maintenance’ for more information.
    Maintain a clean environment. Turn off the system circuit 
    breaker before cleaning the unit. See ‘Cleaning the system’ for 
    more information.
    Never set liquids on the unit to ensure that liquid does not drip 
    into the control panel or unit. 
    						
    							Site Requirements
    LOGIQ 5 Basic User Manual 3-3
    Direction 2300002-100 Rev. 2
    Before the system arrives
    NOTICE This medical equipment is approved, in terms of the prevention 
    of radio wave interference, to be used in hospitals, clinics and 
    other institutions which are environmentally qualified. The use of 
    this equipment in an inappropriate environment may cause 
    some electronic interference to radios and televisions around 
    the equipment. This equipment can be used in residential areas 
    only under the supervision of physicians or qualified technicians.
    Ensure that the following is provided for the new system: 
    •  A separate power outlet with a 5 amp circuit breaker for 120 
    VAC for 120V area, 8 amp circuit breaker for 220-240VAC 
    for 220/240V area or 15 amp circuit breaker for 100 VAC for 
    Japan.
    •  Take precautions to ensure that the console is protected 
    from electromagnetic interference.
    Precautions include: 
    •  Operate the console at least 15 feet away from motors, 
    typewriters, elevators, and other sources of strong 
    electromagnetic radiation.
    •  Operation in an enclosed area (wood, plaster or 
    concrete walls, floors and ceilings) helps prevent 
    electromagnetic interference.
    •  Special shielding may be required if the console is to be 
    operated in the vicinity of radio broadcast equipment. 
    						
    							Preparing the System for Use
    3-4 LOGIQ 5 Basic User Manual
    Direction 2300002-100 Rev. 2
    Environmental Requirements
    The system should be operated, stored, or transported within 
    the parameters outlined below. Either its operational 
    environment must be constantly maintained or the unit must be 
    turned off.
    Table 3-1: System Environmental Requirements
    OperationalStorageTransport (
    						
    							Console Overview
    LOGIQ 5 Basic User Manual 3-5
    Direction 2300002-100 Rev. 2
    Console Overview
    Console graphics
    The following are illustrations of the console:
     Figure 3-1. LOGIQ 5 System (right and left side views)
    1.  Probe and Gel Bottle Holder
    2.  Storage area of Peripheral Device
    3.  Storage area of Peripheral Device
    4.  Release lever to raise and lower Monitor and Control Panel
    5. Side Pocket
    6. Task Light
    100-120V  150VA Max
    6
    23
    4
    5 31
    CAUTIONDO NOT place probes or the footswitch into either the side 
    pocket or the peripheral device’s storage area.  
    						
    							Preparing the System for Use
    3-6 LOGIQ 5 Basic User Manual
    Direction 2300002-100 Rev. 2
    Console graphics (continued)
     Figure 3-2. LOGIQ 5 System (front and back views)
    1.  Optional B/W Video Page Printer
    2.  Probe Ports with optional CWD Probe Port, when available
    3. Footswitch connector
    4.  Optional Physiological Input Panel
    5. MOD
    6. CD ROM
    7. Rear Panel
    8. Task Lamp
    8
    1
    6
    5
    42
    3
    7 
    						
    							Console Overview
    LOGIQ 5 Basic User Manual 3-7
    Direction 2300002-100 Rev. 2
    External drives (CD-RW and/or MO) 
    The external CD-RW drive (Standard) and MO drive (Option) are 
    located next to the probe port.
    They can be used to perform software upgrades, image 
    archiving and service diagnostics.
    CAUTIONMake sure that the CD-RW Disk tray and/or MO Disk are 
    securely placed in each device during system operation. 
    Mechanical damage may occur if other objects hit the tray or 
    MO disk. 
    						
    							Preparing the System for Use
    3-8 LOGIQ 5 Basic User Manual
    Direction 2300002-100 Rev. 2
    Storage areas
    Several convenient storage areas are provided within the 
    console as shown in the figure below. Use them to store gel, 
    options, probe cables, accessories, etc.
     Figure 3-3. Storage Areas
    1. Storage Areas
    100-120V  150VA Max
    PDIPW
    L
    R B Pause Auto
    DepthMZoom
    Ellipse Body PatternMeasure
    M/D Cursor
    Scan AreaSetClear Comment
    Patient
    21L21
    1
    1
    1
    1
    1 1
    1
    CAUTIONDO NOT place probes or the footswitch into either the side 
    pocket or the peripheral device’s storage area.  
    						
    							Console Overview
    LOGIQ 5 Basic User Manual 3-9
    Direction 2300002-100 Rev. 2
    Task Lamp
    The task lamp is used to illuminate the keyboard. 
     Figure 3-4. Task Lamp
    1. Task lamp
    CAUTIONThe task lamp may overheat. Take proper precautions to avoid 
    touching the task lamp. 
    Contact your local Service Representative when the task lamp 
    bulb needs to be replaced.
    1. 
    						
    							Preparing the System for Use
    3-10 LOGIQ 5 Basic User Manual
    Direction 2300002-100 Rev. 2
    Peripheral/Accessory Connection
    Peripheral/Accessory Connector Panel
    LOGIQ 5 peripherals and accessories can be properly 
    connected using the rear connector panel located behind the 
    rear door. Only the B/W Printer can be connected to the front 
    accessory panel.
    Located on the rear panel are video input and output, audio 
    input and output, camera rec/expose, Insite, Ethernet, power 
    and control connections for VCR, printer and service tools. See 
    Figure 3-5 for more specifics.
    CAUTIONEach outer (case) ground line of peripheral/accessory 
    connectors are Earth Grounded.
    Signal ground lines are Not Isolated.
    CAUTIONUse only approved probes, peripherals or accessories.
    Be sure to plug the power supply cable of the peripherals to the 
    connector panel of the system to avoid unexpected electrical 
    shock.
    DO NOT connect any probes or accessories without approval 
    by GE. 
    						