Table Of Contents 1 Introduction 1–1 2 System Records 2–1 2.1 VDT Configuration (Terminal Setup) 2–2 2.2 LCD Messages 2–2 2.3 Serial Data Port Records 2–3 2.4 Subdued Off-Hook Voice Announce Groups 2–4 2.5 Speed Dial Records 2–6 2.6 Timing 2–10 2.7 System Parameters 2–11 2.8 Zone Paging 2–12 2.9 Relays 2–12 2.10 External Paging Port 2–12 2.11 Change Password 2–12 2.12 Feature Renumbering 2–13 2.13 Enabling Status Reporting and Major Alarm Alerting 2–14 2.14 T1 Status Logging 2–14 2.15 Major Alarm Alerting 2–15 3 Station Records 3–1 3.1 COS Programming 3–2 3.2 Station Programming 3–3 3.3 Button Mapping and Telephone Types 3–4 3.4 Copy Model COS 3–26 3.5 Copy Model Station 3–27 3.6 Copy Button Map 3–28 3.7 Hunt Groups 3–29 4 Line Records 4–1 4.1 Line Programming 4–2 4.2 Line Group Programming 4–7 4.3 Copy Model Line 4–7 4.4 System Line Record 4–8 4.5 DID/DNIS Block Programming 4–10 4.6 DISA Configuration Programming Records 4–12 DXP Plus Programming Records IMI66–125 Table Of Contents – iii
5 Intercom Numbers 5–1 5.1 Intercom Record 5–2 6 SMDA/SMDR Records 6–1 6.1 SMDA/SMDR Parameters 6–2 6.2 Automatic Reports 6–2 6.3 Account Code Parameter Records 6–2 6.4 Verified Account Codes 6–3 6.5 Emergency Numbers 6–4 6.6 Authorization Codes 6–4 7 Toll/ARS Records 7–1 7.1 Restriction Tables 7–2 7.2 Staion Restriction Level 7–3 7.3 Toll Groups 7–4 7.4 Route Tables 7–5 7.5 Modify Digit Tables 7–13 8 Printout Records 8–1 8.1 Printout Records 8–2 9 Peripherals 9–1 9.1 Caller ID Records 9–2 9.2 Tracker Records 9–3 9.3 Voice/DVA Records 9–5 9.4 PC Attendant Records 9–6 9.5 Voice Mail Records 9–7 9.6 Modem Setup 9–8 10 Board Configuration 10–1 10.1 Board Configuration Records 10–2 IMI66–125 DXP Plus Programming Records iv – Table Of Contents
Introduction Use these record charts along with GCA40-130, DXP Plus Digital Communications System General System Description, and IMI66-123,DXP Plus Digital Communications System Programming Instructionsto plan the system configuration and feature applications that best complement the site requirements. ·The charts are arranged in the same order that the VDT programming menus are presented. ·Use the index at the end of this publication to locate a programmable feature by name. ·Since the Diagnostics menu item does not require any record keeping, this publication contains no entry tables for it. For a discussion of the system diagnostics, see IMI89–239,Understanding The System Diagnostics, that you can find under the troubleshooting section of your system hardware binder. Main Menu 1. System 2. Stations 3. Lines 4. Intercom Numbers 5. SMDA / SMDR 6. Toll / ARS 7. Printouts 8. Diagnostics 9. Peripherals 10. Board Configuration 11. Logout Enter Selection (1-9): 1 DXP Plus Programming Records IMI66–125 Introduction 1–1
System Records ·From main menu, type selection number for system and pressENTER. ·From system menu, type selection number for feature and pressENTER. System 1. Defaults 2. Terminal Setup 3. LCD Messages 4. Save/Restore Database (use VMMI) 5. Serial Ports 6. SOHVA Table 7. Speed Dials 8. Time and Date 9. Timing 10. System Parameters 11. Paging Zones 12. Change Password 13. Feature Renumbering 14. T1–E1 Status Log Parameters 15. Major Alarm Alerting Enter Selection (1-13): 2 DXP Plus Programming Records IMI66–125 System Records 2–1
2.1 VDT Configuration(Terminal Setup) ANSI Terminal ANSI Color Terminal WYSE 50 Terminal (default) Brief Display Mode 2.2 LCD Messages Number Message(16 Characters Maximum) 01Ba c k a t 02Ca l l 03AskThemToHold 04Take A Me s s age 05I Will Call Back 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 Default = bold italic entries IMI66–125DXP Plus Programming Records 2–2 System Records
2.3 Serial Data Port Records Data Port Baud Rate In Baud Rate Out Data Bits Stop Bits Paity Flow Control Main Data Port 1 Main Data Port 2 Aux Data Port 1 Aux Data Port 2 Aux Data Port 3 Aux Data Port 4 Aux Data Port 5 Aux Data Port 6 Aux Data Port 7 Aux Data Port 8 Aux Data Port 9 Aux Data Port 10 Aux Data Port 11 Aux Data Port 12 Aux Data Port 13 Aux Data Port 14 Aux Data Port 15 Aux Data Port 16 Baud Rates = 150, 300, 600, 1200, 1800, 2400, 4800, 9600 / Data Bits = 7, 8 / Stop Bits = 1, 2 / Parity = None, Even, Odd Flow Control = None, Xon/Xoff, CTR/DTR Defaults: Data Port 1 = 9600, 9600, 8, 1, None, None Data Port 2 = 2400, 2400, 7, 2, None, None Data Ports 3–10 = 19,200, 19,200, 8, 1, None, None Data Ports 11–18 = 9600, 9600, 8, 1, None, None 2.3.1 Modem Setup Feature Default Program Setting Data Portmain data port 2 Initialize StringAT S0=1 M0 Q1 E0 DXP Plus Programming RecordsIMI66–125 System Records 2–3
2.4 Subdued Off-Hook Voice Announce Groups SOHVA Receive 12345678910111213141516 1*..............* S 2.*.............* O 3..*............* H 4...*...........* V 5....*..........* A 6.....*.........* 7......*........* T 8.......*.......* r 9........*......* a 10.........*.....* n 11..........*....* s 12.. . . ....*...* m 13............*..* i 14.............*.* t 15..............** 16**************** Default = * IMI66–125DXP Plus Programming Records 2–4 System Records
2.5 Speed Dial Records 2.5.1 Speed Dial Records 100—199 Dialing Code*Line Selection**Prefix*** Number****Dialing Code*Line Selection**Prefix*** Number**** *Enter 100–199 for dialing codes 100–199 **Enter line number, line group number, prime line/last line used—Beginning with software release 8.B, you can assign intercom as a preselect choice. ***Enter 1–128 for line or enter 1–16 for line group ****Enter 32 digits maximum—enter P for pause and F for hookflash DXP Plus Programming RecordsIMI66–125 System Records 2–5
2.5.2 Speed Dial Records 200—299 Dialing Code*Line Selection**Prefix*** Number****Dialing Code*Line Selection**Prefix*** Number**** *Enter 200–299 for dialing codes 200–299 **Enter line number, line group number, prime line/last line used—Beginning with software release 8.B, you can assign intercom as a preselect choice. ***Enter 1–128 for line or enter 1–16 for line group ****Enter 32 digits maximum—enter P for pause and F for hookflash IMI66–125DXP Plus Programming Records 2–6 System Records
2.5.3 Speed Dial Records 300–399 Dialing Code*Line Selection**Prefix*** Number****Dialing Code*Line Selection**Prefix*** Number**** *Enter 300–399 for dialing codes 300–399 **Enter line number, line group number, prime line/last line used—Beginning with software release 8.B, you can assign intercom as a preselect choice. ***Enter 1–128 for line or enter 1–16 for line group ****Enter 32 digits maximum—enter P for pause and F for hookflash DXP Plus Programming RecordsIMI66–125 System Records 2–7