Home > Comdial > Communications System > Comdial Dxp Plus Instructions Manual

Comdial Dxp Plus Instructions Manual

    Download as PDF Print this page Share this page

    Have a look at the manual Comdial Dxp Plus Instructions Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 133 Comdial manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    Page
    of 1176
    							Table Of Contents
    1 Introduction 1–1
    2 System Records 2–1
    2.1 VDT Configuration (Terminal Setup) 2–2
    2.2 LCD Messages 2–2
    2.3 Serial Data Port Records 2–3
    2.4 Subdued Off-Hook Voice Announce Groups 2–4
    2.5 Speed Dial Records 2–6
    2.6 Timing     2–10
    2.7 System Parameters 2–11
    2.8 Zone Paging 2–12
    2.9 Relays 2–12
    2.10 External Paging Port 2–12
    2.11 Change Password 2–12
    2.12 Feature Renumbering 2–13
    2.13 Enabling Status Reporting and Major Alarm Alerting 2–14
    2.14 T1 Status Logging     2–14
    2.15 Major Alarm Alerting 2–15
    3 Station Records 3–1
    3.1 COS Programming     3–2
    3.2 Station Programming     3–3
    3.3 Button Mapping and Telephone Types 3–4
    3.4 Copy Model COS 3–26
    3.5 Copy Model Station 3–27
    3.6 Copy Button Map 3–28
    3.7 Hunt Groups 3–29
    4 Line Records 4–1
    4.1 Line Programming     4–2
    4.2 Line Group Programming 4–7
    4.3 Copy Model Line 4–7
    4.4 System Line Record 4–8
    4.5 DID/DNIS Block Programming 4–10
    4.6 DISA Configuration Programming Records 4–12
    DXP Plus Programming Records IMI66–125
    Table Of Contents  – iii 
    						
    							5 Intercom Numbers     5–1
    5.1 Intercom Record 5–2
    6 SMDA/SMDR Records 6–1
    6.1 SMDA/SMDR Parameters 6–2
    6.2 Automatic Reports 6–2
    6.3 Account Code Parameter Records 6–2
    6.4 Verified Account Codes 6–3
    6.5 Emergency Numbers 6–4
    6.6 Authorization Codes 6–4
    7 Toll/ARS Records 7–1
    7.1 Restriction Tables 7–2
    7.2 Staion Restriction Level 7–3
    7.3 Toll Groups 7–4
    7.4 Route Tables 7–5
    7.5 Modify Digit Tables 7–13
    8 Printout Records 8–1
    8.1 Printout Records 8–2
    9 Peripherals 9–1
    9.1 Caller ID Records 9–2
    9.2 Tracker Records 9–3
    9.3 Voice/DVA Records 9–5
    9.4 PC Attendant Records 9–6
    9.5 Voice Mail Records 9–7
    9.6 Modem Setup 9–8
    10 Board Configuration 10–1
    10.1 Board Configuration Records 10–2
    IMI66–125 DXP Plus Programming Records
    iv – Table Of Contents 
    						
    							Introduction
    Use these record charts along with GCA40-130, DXP Plus Digital Communications System General System
    Description, and IMI66-123,DXP Plus Digital Communications System Programming Instructionsto plan the
    system configuration and feature applications that best complement the site requirements.
    ·The charts are arranged in the same order that the VDT programming menus are presented.
    ·Use the index at the end of this publication to locate a programmable feature by name.
    ·Since the Diagnostics menu item does not require any record keeping, this publication contains no entry tables
    for it. For a discussion of the system diagnostics, see IMI89–239,Understanding The System Diagnostics, that
    you can find under the troubleshooting section of your system hardware binder.
    Main Menu
    1.  System
    2.  Stations
    3.  Lines
    4.  Intercom Numbers
    5.  SMDA / SMDR
    6.  Toll / ARS
    7.  Printouts
    8.  Diagnostics
    9.  Peripherals
    10. Board Configuration
    11. Logout
    Enter Selection (1-9):
    1
    DXP Plus Programming Records IMI66–125
    Introduction 1–1 
    						
    							System Records
    ·From main menu, type selection number for system and pressENTER.
    ·From system menu, type selection number for feature and pressENTER.
    System
    1. Defaults
    2. Terminal Setup
    3. LCD Messages
    4. Save/Restore Database (use VMMI)
    5. Serial Ports
    6. SOHVA Table
    7. Speed Dials
    8. Time and Date
    9. Timing
    10. System Parameters
    11. Paging Zones
    12. Change Password
    13. Feature Renumbering
    14. T1–E1 Status Log Parameters
    15. Major Alarm Alerting
    Enter Selection (1-13):
    2
    DXP Plus Programming Records IMI66–125
    System Records 2–1 
    						
    							2.1 VDT Configuration(Terminal Setup)
    ANSI Terminal
    ANSI Color Terminal
    WYSE 50 Terminal (default)
    Brief Display Mode
    2.2 LCD Messages
    Number Message(16 Characters Maximum)
    01Ba c k a t
    02Ca l l
    03AskThemToHold
    04Take A Me s s age
    05I Will Call Back
    06
    07
    08
    09
    10
    11
    12
    13
    14
    15
    16
    17
    18
    19
    20
    21
    22
    23
    24
    25
    26
    27
    28
    29
    30
    Default = bold italic entries
    IMI66–125DXP Plus Programming Records
    2–2  System Records 
    						
    							2.3 Serial Data Port Records
    Data Port Baud Rate In Baud Rate Out Data Bits Stop Bits Paity Flow Control
    Main Data Port 1
    Main Data Port 2
    Aux Data Port 1
    Aux Data Port 2
    Aux Data Port 3
    Aux Data Port 4
    Aux Data Port 5
    Aux Data Port 6
    Aux Data Port 7
    Aux Data Port 8
    Aux Data Port 9
    Aux Data Port 10
    Aux Data Port 11
    Aux Data Port 12
    Aux Data Port 13
    Aux Data Port 14
    Aux Data Port 15
    Aux Data Port 16
    Baud Rates = 150, 300, 600, 1200, 1800, 2400, 4800, 9600 / Data Bits = 7, 8 / Stop Bits = 1, 2 / Parity = None, Even, Odd
    Flow Control = None, Xon/Xoff, CTR/DTR
    Defaults: Data Port 1 = 9600, 9600, 8, 1, None, None
    Data Port 2 = 2400, 2400, 7, 2, None, None
    Data Ports 3–10 = 19,200, 19,200, 8, 1, None, None
    Data Ports 11–18 = 9600, 9600, 8, 1, None, None
    2.3.1 Modem Setup
    Feature Default Program Setting
    Data Portmain data port 2
    Initialize StringAT S0=1 M0 Q1 E0
    DXP Plus Programming RecordsIMI66–125
    System Records 2–3 
    						
    							2.4 Subdued Off-Hook Voice Announce Groups
    SOHVA Receive
    12345678910111213141516
    1*..............*
    S 2.*.............*
    O 3..*............*
    H 4...*...........*
    V 5....*..........*
    A 6.....*.........*
    7......*........*
    T 8.......*.......*
    r 9........*......*
    a 10.........*.....*
    n 11..........*....*
    s 12.. . . ....*...*
    m 13............*..*
    i 14.............*.*
    t 15..............**
    16****************
    Default = *
    IMI66–125DXP Plus Programming Records
    2–4  System Records 
    						
    							2.5 Speed Dial Records
    2.5.1 Speed Dial Records 100—199
    Dialing
    Code*Line
    Selection**Prefix*** Number****Dialing
    Code*Line
    Selection**Prefix*** Number****
    *Enter 100–199 for dialing codes 100–199
    **Enter line number, line group number, prime line/last line used—Beginning with software release 8.B,
    you can assign intercom as a preselect choice.
    ***Enter 1–128 for line or enter 1–16 for line group
    ****Enter 32 digits maximum—enter P for pause and F for hookflash
    DXP Plus Programming RecordsIMI66–125
    System Records 2–5 
    						
    							2.5.2 Speed Dial Records 200—299
    Dialing
    Code*Line
    Selection**Prefix*** Number****Dialing
    Code*Line
    Selection**Prefix*** Number****
    *Enter 200–299 for dialing codes 200–299
    **Enter line number, line group number, prime line/last line used—Beginning with software release 8.B,
    you can assign intercom as a preselect choice.
    ***Enter 1–128 for line or enter 1–16 for line group
    ****Enter 32 digits maximum—enter P for pause and F for hookflash
    IMI66–125DXP Plus Programming Records
    2–6  System Records 
    						
    							2.5.3 Speed Dial Records 300–399
    Dialing
    Code*Line
    Selection**Prefix*** Number****Dialing
    Code*Line
    Selection**Prefix*** Number****
    *Enter 300–399 for dialing codes 300–399
    **Enter line number, line group number, prime line/last line used—Beginning with software release 8.B,
    you can assign intercom as a preselect choice.
    ***Enter 1–128 for line or enter 1–16 for line group
    ****Enter 32 digits maximum—enter P for pause and F for hookflash
    DXP Plus Programming RecordsIMI66–125
    System Records 2–7 
    						
    All Comdial manuals Comments (0)