12-4 Data base Prin ting Datab ase Printin g Pr in t Sys t em Pa ra m et er s Pro g ram mi ng S te ps 1. Press the SYSTEM PARAMETERS flexible button ( FLASH 85, Bu tton #1). Th e f oll owing me ssa ge dis pla ys: 2. To print the System Parameters database, press the HOLD button. The f oll owing me ssa ge dis pl ays: Whe n t he syst em fi nis hes se ndi ng t he in form at ion to t he pr in te r, a confirma tion tone is he ard. Des crip ti on The currently stored customer database can be printed or uploaded into a file. This command dumps the entire database as a permanent record whi ch can s er ve as a har dcopy of t he dat aba se . T he syst e m ba ud r at e must ma tc h tha t of t he pr int e r or r ec e iv ing de vic e . W hen pr int i ng t he System Parameters the following data prints: †All System Timers †All System Wide Options (External Night Ringing, Hold Preference) †Attenda nt Station(s ) Prog ram ming †Other System Assignments (Page/Relay Assign, Exec/Sec, SMDR) †Wee kl y Ni ght Mode Sche dul e P RIN T SY S PAR AM P RE SS H OLD P RIN T SY S PAR AM
Da ta b a se P r i n t i n g 1 2- 5 Figure 12-1: Sy stem Pa ra me ters Printout ----- SYSTEM PARAMETERS ---- --------------------SYSTEM FEATURES ------------- SYS HOLD RECALL EXC HOLD RECALL ATND RECALL TIMER TRANSFER RECALL PRESET FWD TIMER CALL FWD NO ANS PAUSE TIMER CALL PARK TIMER CONFERENCE TIMER PAGING TIMEOUT CO RING DETECT SLT RCVR TIMER M/W TONE TIMER HOOK SWITCH TIME HOOK SWT BOUNCE SMDR CALL QUAL AUTO CALL BACK REMINDER RING RELEASE GUARD INTERDIGIT T/O RPT REDIAL ATTENDANT DISPLAY CALL COVERAGE RING MODEM ANSWER T/O INT DIGIT PULSE DTMF ON/OFF TIME -- SYSTEM FEATURES ATTENDANT OVERRIDE HOLD PREFERENCE EXTERNAL NIGHT RING EXECUTIVE WARNING PAGE WARNING TONE BACKGROUND MUSIC LEAST COST ROUTING FORCED ACCOUNT CODE GROUP LISTENING IDLE SPEAKER MODE CALL COST DISPLAY MUSIC ON HOLD CALL QUALIFIER TONE BARGE IN WARN TONE60 180 1 45 10 15 2 180 10 15 3 20 0 10 10 30 3 0 3 5 60 1 5 25 300 1 -------- DISABLED SYSTEM DISABLED ENABLED ENABLED ENABLED DISABLED DISABLED DISABLED DISABLED DISABLED ENABLED DISABLED ENABLEDCO RING TONES VERIFIED ACCT CODES CALL FWD DISPLAY EXTERNAL DAY RING OVERFLOW STA FWD DIRECT XFER STATION LOCK LCR CALL PROGRESS RECORDING WARN TONE MAINTENANCE RINGBACK ON XFER DID/TIE SIGNALING 911 FEATURE -------------SYSTEM INC CO RING INC ICM RING CALL FORWARD BTN MSG WAIT VM BTN MSG CBCK DSS/BLF DND DSS/BLF AUTO CBCK DSS/BLF UCD UNAVL DSS/BLF TRANSFER CO RING RECALL CO RING EXCLUSIVE HOLD QUEUED CO RING SYSTEM HOLD IN USE HOLD CAMP ON BTN CALL BACK BTN LINE QUEUE BTN DND BTN ICM HOLD BTN LEADING DIGIT 1 LEADING DIGIT 2 LEADING DIGIT 3 LEADING DIGIT 4 LEADING DIGIT 5 LEADING DIGIT 6 LEADING DIGIT 7 LEADING DIGIT OPTION CENTREX DIGITS VM ID DIGITSENABLED DISABLED ENABLED DISABLED DISABLED ENABLED DISABLED ENABLED ENABLED DISABLED DISABLED DISABLED DISABLED LE D RE D RE D RE D RE D RE D RE D RE D RE D RE D RE D GREEN GREEN RE D GREEN RE D RE D RE D RE D RE D LEADING NONE NONE NONE NONE NONE NONE DISABLED 4 3FLASH RATES ------- 480 IPM FLUTTER 120 IPM FLUTTER STEADY ON STEADY ON 120 IPM FLUTTER 60 IPM DBL WINK OFF 120 IPM FLASH 60 IPM DBL WINK OFF 120 IPM FLASH 480 IPM FLUTTER 120 IPM FLASH 480 IPM FLUTTER 60 IPM DBL WINK OFF 60 IPM FLASH 120 IPM FLASH 120 IPM FLASH 480 IPM FLUTTER STEADY ON 15 IPM FLASH DIGIT
12-6 Data base Prin ting MUSIC CHANNEL[3..8] CABINET SLOT TYPE CO - ## #### ## ## ## ------- ---- ---- 0 0 DT24 ATTENDANT STATIONS 0 1 DTIB 100 ## ## ## ## ## ## 0 2 DTIB 0 3 NONE DATE & TIME FORMAT 0 4 SLIB MM/DD/YY, 12 HOURS 0 5 NONE 0 6 LCOB PBX DIALING CODES 0 7 PRIB ## ## ## ## ## 0 8 LCOB 09MPB EXECUTIVE/SECRETARY PAIRINGS 1 0-9 NONE 1 = ### ### 2 0-5 NONE 2 = ### ### 3 0-5 NONE 3 = ### ### 4 = ### ### POWER SUPPLY TYPES (Triad 3) ---------------------------- ON BOARD RELAY ASSIGNMENTS 10 AMPS 10 AMPS 10 AMPS 10 AMPS NONE NONE NONE NONE NONE NONE ALARM DESC. ALARM PERIOD THRESHOLD ATTENDANT MINOR MAJOR I/O BAUD RATE CARRIER LOSS Y 5 15 30 Y ------------------ BLUE ALARM Y 5 15 30 Y Port 1 = 9600 YELLOW ALARM Y 5 15 30 Y Port 2 = 2400 RED ALARM Y 5 15 30 Y Port 3 = 9600 BIPOLAR VAR. Y 5 15 30 Y Port 4 = 9600 SLIP ALARM Y 5 15 30 Y DATA ERRORS Y 5 15 30 Y AUTO NIGHT MODE N WEEKLY NIGHT MODE SCHEDULE -------------------------- END START DAY TIME TIME M 0 0800 1700 T 1 0800 1700 W 2 0800 1700 T 3 0800 1700 F 4 0800 1700 S 5 #### #### S 6 #### #### DIAL PULSE - 60/40 10 PPS Figure 12-1: Sy stem Pa ra me ters Printout
Da ta b a se P r i n t i n g 1 2- 7 Print CO Line Attributes Pro g ram mi ng S te ps 1 . Pr es s t he CO LI NE ATT R IBU TES fl ex ibl e but ton (F L ASH 8 5, Bu tton #2). Th e f oll owing me ssa ge dis pla ys: 2. To print data for: †AL L CO Li ne s, p re ss the HO LD button. †A specified CO Line Range, enter 6 digits (3 digits for the first line and 3 digits for the last line in the range): †One CO Li ne, en te r tha t l i ne twi c e: [0 01 0 01 ] 3 . The n pr ess the HO LD but t on. Th e fol lowi ng me ss age d is pla ys and the CO L ine da ta pr int s: When the system finishes sending the requested information to the printer, a conf irmation to ne is hea rd. Des crip ti on The Print CO Line Attributes command dumps the entire database as a permanent record which can serve as a hardcopy of the database The system baud rate must match that of the printer or receiving device. Whe n pr in ti ng t he CO Li ne at tr i but es the f oll owing dat a pr int s: †All CO Line parameters within the specified range. †CO Lin e r i ngin g as si gnmen ts wi thi n t he spe c if ie d r ange . †Di al Pulse Ra ti o a nd S pee d s etti ngs PRINT CO LINES P RE SS H OLD PRINTI NG CO LINE S
12-8 Data base Prin ting Figure 12-2: CO Line Attributes Printout CO LINE ATTRIBUTES ------------------ CO 01 CO 02 ------ ----- DIAL PULSE/DTMF - DTMF DIAL PULSE/DTMF - DTMF PBX/CO - CO PBX/CO - CO UNIVERSAL NIGHT ANS - ENABLED UNIVERSAL NIGHT ANS - ENABLED DISA TRK TO TRK - ENABLED DISA TRK TO TRK - ENABLED PRIVACY - ENABLED PRIVACY - ENABLED LOOOP SUPERVISION - 4 LOOP SUPERVISION - 4 DISA TYPE - NONE DISA TYPE - NONE LINE GROUP - 1 LINE GROUP - 1 CLASS OF SERVICE - 1 CLASS OF SERVICE - 1 LINE IDENTIFICATION - LINE 01 LINE IDENTIFICATION - LINE 02 CO DIRECTION - INCOMING-OUTGOING CO DIRECTION - INCOMING-OUTGOING RING ASSIGNMENTS RING ASSIGNMENTS 100A 100A T-1 SIGNAL TYPE - LOOP START T-1 SIGNAL TYPE - LOOP START T-1 RINGBACK - ENABLED T-1 RINGBACK - ENABLED T-1 DIALTONE - DISABLED T-1 DIALTONE - DISABLED TRANSMIT VOLUME - 0DB TRANSMIT VOLUME - 0DB PRESET FORWARD DEST - NONE PRESET FORWARD DEST - NONE PRESET FWD VMID - NONE PRESET FWD VMID - NONE UNIVERSAL DAY ANSWER - DISABLED UNIVERSAL DAY ANSWER - DISABLED MOH CHANNEL - 1 MOH CHANNEL - 1 RING TONE - 0 RING TONE - 0 DID/TIE SIGNALLING - WINK DID/TIE SIGNALLING - WINK 911 TRUNK - DISABLED 911 TRUNK - DISABLED FLASH TIMER - 10 FLASH TIMER - 10 RING DELAY TIMER - 0 RING DELAY TIMER - 0 WINK TIMER - 140 WINK TIMER - 140 RELEASE TIMER - 20 RELEASE TIMER - 20 RESEIZE TIMER - 200 RESEIZE TIMER - 200 GUARD TIMER - 50 GUARD TIMER - 50 SEIZE TIMER - 10 SEIZE TIMER - 10 PRESET FWD TIMER - 100 PRESET FWD TIMER - 100 DID COLLECT TIMER - 15 DID COLLECT TIMER - 15 T1 COLLECT TIMER - 15 T1 COLLECT TIMER - 15 ... and so on through CO lines: 001-04 8 = Tr i ad 1 / 2 00 1-144 = Tr ia d 3
Da ta b a se P r i n t i n g 1 2- 9 Print Station Attributes Pro g ram mi ng S te ps 1 . Pr es s t h e STATI ON AT TR I B U TE S f le x ib le bu t to n (FLASH 85, Bu tton #3). Th e f oll owing me ssa ge dis pla ys: 2. To print data for: †Al l st at ions , p re ss the HO LD but ton. †A specified Station Range, enter six digits to specify the Station ra nge (thr ee di gi ts for t he fir st st at i on and th re e d igi ts for t he la st st at ion in the r ange ): [100-171] = Tri ad 1 /2 [100-351] = Tri ad 3 †One station, enter that station twice: [101101] 3 . The n pr ess the HO LD but t on. Th e fol lowi ng me ss age d is pla ys and the requested information prints: When the system finishes sending the requested information to the printer, a conf irmation to ne is hea rd. Des crip ti on The Print Station Attributes command dumps the entire database as a permanent record which can serve as a hardcopy of the database. The system baud rate must match that of the printer or receiving device. Whe n pr in ti ng t he St at io n at t ri but es th e f oll owin g dat a pr int s: >> > All Cu rr en t St at io n P ar a met ers PRINT STATIONS P RE SS H OLD PRINTI NG STAT IONS
12- 1 0 D ata base Pr i n ti ng Figure 12- 3: Station Attributes Printout STATION ATTRIBUTES STA 100 STA 101 PAGE ACCESS ENABLED PAGE ACCESS ENABLED DO NOT DISTURB ENABLED DO NOT DISTURB ENABLED CONFERENCE ENABLED CONFERENCE ENABLED EXEC OVERRIDE DISABLED EXEC OVERRIDE DISABLED PRIVACY ENABLED PRIVACY ENABLED SYSTEM SPEED ENABLED SYSTEM SPEED ENABLED LINE QUEUING ENABLED LINE QUEUING ENABLED PREF LINE ANSWER DISABLED PREF LINE ANSWER DISABLED OFF HOOK VOICE OVER DISABLED OFF HOOK VOICE OVER DISABLED CALL FORWARD ENABLED CALL FORWARD ENABLED FORCE LCR DISABLED FORCE LCR DISABLED ACD SUPV BARGE IN DISABLED ACD SUPV BARGE IN DISABLED EXEC OVERRIDE BLOCK DISABLED EXEC OVERRIDE BLOCK DISABLED CO RING OPTIONS MUTED RING CO RING OPTIONS MUTED RING NAME AT IDLE LCD EXT NUMBER NAME AT IDLE LCD EXT NUMBER ACD ZAP TONE DISABLED ACD ZAP TONE DISABLED STATION ID KEYSET - SP 24BTN STATION ID KEYSET - SP 24BTN CO LOOP POOL FLEX DISABLED CO LOOP POOL FLEX DISABLED DAY COS 1 DAY COS 1 NIGHT COS 1 NIGHT COS 1 SPEAKERPHONE FULL SPEAKERPHONE SPEAKERPHONE FULL SPEAKERPHONE PICKUP GROUPS 1 PICKUP GROUPS 1 PAGE ZONE 1 PAGE ZONE 1 INTERNAL NO ANSWER ### INTERNAL NO ANSWER ### INTERNAL BUSY ### INTERNAL BUSY ### EXTERNAL NO ANSWER ### EXTERNAL NO ANSWER ### EXTERNAL BUSY ### EXTERNAL BUSY ### NO ANSWER TIMER 10 NO ANSWER TIMER 10 LINE GROUP ACCESS 1 LINE GROUP ACCESS 1 LCR CLASS OF SERVICE 0 LCR CLASS OF SERVICE 0 OFFHOOK PREFENCE BTN 00 ENABLED OFFHOOK PREFENCE BTN 00 ENABLED KEYSET MODE INACTIVE MODE 2400 KEYSET MODE INACTIVE MODE 2400 VOICE MAIL ID 100 VOICE MAIL ID 101 CORDLESS KEY BTN 00 LIGHT CONTROL NONE BUTTONS: DISPLAY LCD MSG NONE 01D100 02D101 03D102 CORDLESS KEY BTN 00 04D103 05D104 06D105 BUTTONS: 07D106 08D107 09D108 01100 02D101 03D102 10D109 11D110 12D111 04D10 05C001 06C002 13L001 14C002 15L003 07LP 08PL1 09CBK 16L004 17L005 18L006 10PKU 11DND 12LQU 19LP 20PL1 21CBK 13L001 14C002 15L003 22PKU 23DND 24LQU 16L004 17L005 18L006 25FLA 26XFR 27SPD 19LP 20PL1 21CBK 28CNF 29MSG 30FWD 22PKU 23DND 24LQU 31MUT 32CPO 33MON 34HLD 35VOL 36VOL ... and so on through stations: 100-171 = Triad 1/2100-351 = Triad 3 NO TE: T he bu tt on p ri nt out fo r the 8 - but ton k ey s et d is p la ys al l fl e xi bl e A N D f ix ed but to ns , th e s ame a s th e 2 4 -bu tt on k e ys e t.
Da taba se Print ing 12 -11 Pr in t CO Po rt Pa r am e te rs Pro g ram mi ng S te ps 1 . Pr es s t he CO P OR T fl ex ibl e but ton (FLASH 8 5, Bu tton #4). The following message displays: 2. To print the CO Port parameters, press the HOLD button. The f oll owing me ssa ge dis pl ays: When the system finishes sending the requested information to the printer, a conf irmation to ne is hea rd. Des crip ti on The Print CO Port command dumps the entire database as a permanent re c o rd whi c h c an se rve a s a har dc o py o f t he dat ab ase . T he sys te m ba ud ra te mu s t mat c h t hat o f the pr i nte r o r re c ei vi ng de vi c e. Figure 12-4: CO Port Attributes Printout PRINT CO PORT S/CODES P RE SS H OLD PRINTI NG CO PORT CO PORT NUMBERS 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18- - - - - - - - - - - - - - - - - -01 09 17 25 33 41 49 57 65 73 81 89 97 105 113 121 129 13702 10 18 26 34 42 50 58 66 74 82 90 98 106 114 122 130 13803 11 19 27 35 43 51 59 67 75 83 91 99 107 115 123 131 13904 12 20 28 36 44 52 60 68 76 84 92 100 108 116 124 132 14005 13 21 29 37 45 53 61 69 77 85 93 10 1 10 9 11 7 12 5 13 3 14 106 14 22 30 38 46 54 62 70 78 86 94 102 110 118 126 134 14207 15 23 31 39 47 55 63 71 79 87 95 103 111 119 127 135 14308 16 24 32 40 48 56 64 72 80 88 96 104 112 120 128 136 144
12- 1 2 D ata base Pr i n ti ng Pr in t Exc eptio n Tabl es Pro g ram mi ng S te ps 1 . Pr es s t he EXC EP T TA BLES fl exi bl e butt on ( FLASH 85, Butto n #5 ). The following message displays: 2 . To pr int t he Exce pt Ta bl es, pr es s t he HOL D b utt on. The fol lowi ng m ess age di spl ays : When the system finishes sending the requested information to the printer, a conf irmation to ne is hea rd. Des crip ti on The Pr int E xcept i on T abl es command dump s t he en ti re da ta base a s a permanent record which can serve as a hardcopy of the database. The system baud rate must match that of the printer or receiving device. When printing information from the Exception Tables, the following data pr int s: †Allow Table A †De ny Tabl e A †Allow Table B †De ny Tabl e B †Spe c ia l Ta ble 1 †Spe c ia l Ta ble 2 †Spe c ia l Ta ble 3 †Spe c ia l Ta ble 4 P RIN T EX TAB LES P RE SS H OLD PRINTI NG EX TABL ES
Da taba se Print ing 12 -13 Figure 12-5: Ex ception T ables Printout ALL OW TA BLE A SPE CI AL TA BLE 1 AR EA CO DE --- --- -- --- -- --- -- --- -- --- -- --- --- -- --- -- --- - 01 1 1 ALL OW ED OF FIC E COD ES 02 1 2 03 1 3 04 1 4 05 1 5 SPE CI AL TA BLE 2 AR EA CO DE 06 1 6 --- -- --- -- --- -- --- --- -- --- -- --- - 07 1 7 ALL OW ED OF FIC E COD ES 08 1 8 09 1 9 10 2 0 SPE CI AL TA BLE 3 AR EA CO DE DEN Y T AB LE A --- -- --- -- --- -- --- --- -- --- -- --- - --- --- -- --- -- ALL OW ED OF FIC E COD ES 01 0 6 02 0 7 03 0 8 04 0 9 SPE CI AL TA BLE 4 HO ME AR EA CO DE 05 1 0 --- -- --- -- --- -- --- --- -- --- -- --- - ALL OW ED OF FIC E COD ES ALL OW TA BLE B --- --- -- --- -- 01 1 1 02 1 2 03 1 3 04 1 4 05 1 5 06 1 6 07 1 7 08 1 8 09 1 9 10 2 0 DEN Y T AB LE B --- --- -- --- -- 01 0 6 02 0 7 03 0 8 04 0 9 05 1 0