Introduction 11-3 Introduction Pro g ram mi ng S te ps If the system is in the programming mode, continue using the program codes. If starting to program here, enter the programming mode. Pr es s FLASH and di al [80 ]. The following message displays: Des crip ti on This section lets portions of the database be initialized individually. The initialization occurs regardless of the position of switch #8 on the MPB. The only way to initialize the entire database is to move switch #8 on the MPB board to the ON position and reset or power off/on the system. A Sys te m Re se t (but ton #2 0) comman d i s a ls o in clude d i n t hi s s ect ion for clearing meantime errors without initializing the database. The buttons on the key telephone are defined as shown: INITIA LIZE DATABASE ENTE R BUTTON NUMBER SYSTEM PARAMETER SCO LINE ATTR IBUTESSTATIO N ATTRIBU TESPO RT - STA/CO =1Q=2W=3E=4R EXCEPTIO N TAB LESSYSTEM SPEED NUM BERSLCR TABLESI C L I D/ DI D TA B LE S =5T=6Y=7U=8I DI REC TO RY DI A L TA B LEHUN T GROU PSACD* OR U CD GR OUP SV OICE M AIL GRO UPS =9O=10 P=11 A=12 S DI D- TI E PARAMETER SVE R IF I E D ACCT CODESISDN PARAM ETER S =13 D=14 F=15 G=16 H SYSTEM RESET =17 J=18 K=19 L=20 ; =21 Z=22 X=23 C=24 V
11-4 I ntro ductio n In it i al iz e Sy st em Pa ra m et er s Pro g ram mi ng S te ps 1. Press the SYSTEM PARAMETERS flexible button ( FLASH 80, Bu tton #1). The fo ll owing mes sag e d is pla ys: 2. Press the HOLD button. A confirmation tone is heard. Des crip ti on The System Parameters may be initialized setting all data fields to their original, default values. The following data fields are returned to their default values upon initializing the System Parameters. INITIA LIZE S YS PARAM P RE SS HO LD
Introduction 11-5 Table 11-1: Syste m Paramete r Defa ults Pr o g r a m C o d eFl ex ButtonF eat ure sDef ault V alue ( after initialization) FLASH 0 1 SYSTEM TI MERS 1 Syste m Ho ld Rec all Timer 060 sec 2 Exc lusi ve Ho ld Rec al l Ti mer 180 sec 3 Atten d an t R eca ll Timer 1 mi n 4 Tra n sfer R eca ll Timer 45 sec 5 Preset Fo rward Ti mer 10 sec 6 C al l For wa rd No /An swer Timer 15 sec 7 Pause Ti mer 2 sec 8 Cal l Park Rec all Timer 180 sec 9 Co nfer enc e/D ISA Ti mer 10 min 10 Pagi ng Time -ou t Tim er 15 sec 11 CO R in g Detec t Ti mer 3=300 ms 12 SLT DTMF R eceiver Ti mer 20 sec 13 Message Wai t Rem in der Ton e 000=Disabl ed 14 SLT Ho ok Flash Ti mer 10 (1 sec) 15 SLT Ho ok Flash Debou nc e Tim er 030=30 0 ms 16 SMDR C al l Qu al ific a tio n Ti mer 30 sec 17 Aut oma ti c C a ll Ba ck Ti mer 03 sec 18 Rem inder R in g Timer 00 sec 20 Flexible Inter-Digit Timeout 5 sec FLASH 0 2 A DDITI ONAL SYSTEM TI MER S 1 Repeat R edial Timer 60 sec 2 Atten d an t D isp la y Time r 01 sec 3 C al l C ov era ge Rin g Timer 5 sec 4 Modem A nswer T / O 25 sec 5 Pul se Dial I nter -Di gi t Tim er 300 ms 6 Pro gra m ma bl e D TM F Time Op era ti on 1=100 ms
11-6 I ntro ductio n FLASH 0 5SYSTEM FEATURES 1 1 Atten d an t Overr id e D isab led 2 Ho ld Preference System 3 External Night Ring Disabled 4 Exec uti ve Over rid e Warn in g Ton e En ab led 5 Page War ning Tone Enabled 6 Background Music Channel Enabled 7 Lea st Co st Ro ut in g D isa b led 8 Acc ount Codes - Forced Disabled 9 Gro up L ist enin g D isa b led 10 Idle Speaker Mode Disabled 11 Call Cost Display Disabled 12 Musi c-On -Ho ld En abled 13 C al l Qu al ifier Ton e D isa b led FLASH 0 6 SYSTEM FEATURES 2 1 Barge-In Tone Enabled 2 CO Ring Tones Enabled 3 Veri fied Acc ou nt C o des D isa b led 4Call Forward Display Enabled 5 Ext ernal Day R ing Disabled 6 Ov erflo w Sta t ion For wa rd D isa b led 7 Di rec t Transfer Mo de Enabled 8 Statio n ID Lo ck D isab led 9 LCR Call Progress Enabled 10 One-Tou ch Rec ord in g W ar ni ng To ne En a b led 11 Ri ngback on Transfer Disabled 12 ACD Ag ent Rec all Disabled 13 911 Featur e Disabled 14 Enh anc ed 91 1 Disabled 15 VM I D St a tio n N um be r s S TA Nu mb e rs = V M IDTable 11-1: Syste m Paramete r Defa ults Pr o g r a m C o d eFl ex ButtonF eat ure sDef ault V alue ( after initialization)
Introduction 11-7 FLASH 0 7FLASH RATES 1 In co min g CO Lin e Ri ng in g Red 480 i pm flu tter 2 In co min g Int erco m R in gi ng Red 120 i pm flu tter 3 Cal l For ward Butto n Red Steady On 4 Message Wait/VM Button Red Steady On 5 Message Call Back – DSS/B LF Red 120 i pm flu tter 6Do Not Disturb – DSS/ BL F Red 60 ip m D bl Wi nk 7 Aut o C a llB a ck – DSS/BLF Red 120 i pm flash 8 UCD Available/Unavailable – D SS/ BL F Red 60 ip m D bl Wi nk 9 Tran sfer CO Rin g ing Red 120 i pm flash 10 Rec all CO Ri ng in g Red 480 i pm flu tter 11 Queued CO Ri nging G reen 4 80 ipm fl utt er 12 Exc lusi ve Ho ld G reen 1 20 ip m fl ash 13 Syste m Ho ld Red 60 ip m D bl Wi nk 14 In Use Hold (I-Hold) Green 60 ipm flash 15 Cam p-On Bu tto n Red 120 i pm flash 16 Cal l B ac k Bu tto n Red 120 i pm flash 17 Line Qu eue But to n Red 480 i pm flu tter 18 Do Not Disturb Button Red Steady On 19 In terc om Ho ld Bu tto n R ed 1 5 ip m fla sh FLASH 0 9 1-6 MOH Assi gn men ts N on e 7 E911 Po wer Fai lu re Stati on N on e FLASH 1 0 -- Atten dan t Stat ion Assig n ment STA 1 00 FLASH 1 1 1-4 Syste m Tim e And Date MMM/DD/Y Y, 12- ho ur di s pl ay FLASH 1 2 -- PBX Dial ing Codes None FL ASH 1 3 1-4 Exec uti ve /Secr etary Pair s N on e FLASH 1 4 1-6 On-Board Rel ay NoneTable 11-1: Syste m Paramete r Defa ults Pr o g r a m C o d eFl ex ButtonF eat ure sDef ault V alue ( after initialization)
11-8 I ntro ductio n FLASH 1 5B AUD RATE ASSI GNMENTS 1 Por t #1 (On -Bo ard RS-232C) 9600 B au d 2 Por t #2 (On -Bo ard Baud Mo dem ) 2400 B au d 3 Por t #3 (SI U2 Mo dule RS-232) Optio nal 9600 B au d 4 Por t #4 (SI U2 Mo dule RS-232) Optio nal 9600 B au d FLASH 1 6 1-3 Net wor king Tables None FLASH 2 0 1 DI SA Acc ess Code 100 2 Dat abase Admin Passwor d 32 26 FL ASH 2 1 1 SMDR Ena b le/ Di sab le N o 2 Long Distance/ Local Assi gnment Long Distance 3 C ha ra c te r Pr int As s ig nm e nt 8 0 4Baud Rate Display 9600 5 SMDR Por t Assi gnments Por t #1 FLASH 2 2 1 Aut omatic/Manual Operat ion Manual=None; Auto= M-F 08:00 17:00 Sat- Sun ##:## ##:## 2-8 Da y of W eek P rog ra mm ing N on e FLASH 2 3 1-4 Di rec tor y Di alin g Tabl e N on e FLASH 2 4 1-12 Car d Sl ots (0-1 1) Slo t 0 15 /16 Powe r Supply Types (0-1)(Tr ia d 3)10 Amp 17-20 Cabin ets (0-3) Cabin et 0 FLASH 3 0 1-12 Hu nt Gro up N on e 13 Station/Pilot/Pilot Ring All--Hunting Assignm entsPi lo t FLASH 3 1 1 Veri fied Acc ou nt Co de En tr y N on e 2COS None FLASH 3 9 1-24 CO G rou p Queu in g En abledTable 11-1: Syste m Paramete r Defa ults Pr o g r a m C o d eFl ex ButtonF eat ure sDef ault V alue ( after initialization)
Introduction 11-9 In iti al iz e CO Lin e A ttr ibu tes Pro g ram mi ng S te ps 1 . Pr es s t he CO LI NE ATT R IBU TES fl ex ibl e but ton (FLA SH 80, Bu tton #2). The following message displays: 2. Press the HOLD button. A confirmation tone is heard. Des crip ti on The CO Line parameters may be initialized setting all data fields to their original, default values. The following data fields are returned to their default value upon initializing the CO Line Attributes. INITIA LIZE CO LINES P RE SS HO LD Table 11-2: CO Line Attribute Defaults Pr o g r a m Co d eFlex ButtonFeat uresDef ault Va lue ( a ft er in i t ia li z at i on ) FLASH 40 PA G E A1 D TMF/ D ia l Pu lse Pr og ra mmi ng D TMF 2 C O/ PB X P rog ra mm ing C O 3 UN A Pr og ra mmi ng En a bl ed 4 DISA CO-to-CO (Per CO Line) Enabled 5Privacy Enabled 6 Loo p Su per visio n Prog ramm in g 4=400 m s 7 D ISA Pr og ra mmi ng No n e 8 CO Li ne G rou p Pro gram min g G ro up 1 9 C la ss of Ser v ic e (COS) Pro gra m min g COS 1 10 CO Line Ringing Assignments (blank) 1 1 C O Li ne I den tifi ca ti on Di spl ay L ine XX X 1 2 C O Di rect io n In com in g/ Outg oi ng 1 3 Display Ring Assignments None 1 4 DID/TIE Signal Type Wink 1 5 911 Tru nk Disabl ed
11- 1 0 I ntr o ducti o n FLASH 40 PA G E B1 T - 1 S i gn al in g T y pe Lo op S ta r t 2T-1 Ringback Enabled 3 T-1 Dial Tone Disabled 4 Tr an smi t Vo lu me 5 =0 db 5 Preset Cal l For ward Dest inat ion #### 6 Preset Forw ar d Voic e Mail #### 7 Universal Day Answ er Disabl ed 8 Mu sic-On -Ho ld p er C O Li ne C h an n el 1 9 Ring Tone per CO Line Tone # 00 FLASH 40 PA G E C1 Fla sh Ti mer Prog ra mm in g 10=1 .0 sec 2 Ri ng D ela y Timer 00=D isa b led 3 Wink Timer 140 ms 4 Rel ease Timer 020=200 m s 5 Resei ze Tim er 200=200 m s 6 Gu a rd Timer 05=.5 sec 7 Seiz e Timer 010=0.1 sec 8 Preset Fo rw ar d Ti mer 10 sec 9 DID Co ll ect Timer 015=150 m s 1 0 T-1 Col lec t Tim er 015=150 m sTable 11-2: CO Line Attribute Defaults Pr o g r a m Co d eFlex ButtonFeat uresDef ault Va lue ( a ft er in i t ia li z at i on )
Introduction 11-11 Initialize Station Attributes Pro g ram mi ng S te ps 1 . Pr es s t h e STATI ON AT TR I B U TE S f le x ib le bu t to n (FLASH 8 0, Bu tton #3). The following message displays: 2. Press the HOLD button. A confirmation tone is heard. Des crip ti on The Station Parameters may be initialized setting all data fields to their original, default values. The following data fields are returned to their default value upon initializing the Station Attributes. INITIA LIZE S TATIONS P RE SS HO LD Tabl e 1 1- 3: St at io n At t ri but e Def ault s Progra m CodeFl ex ButtonFeat uresDef ault V alue ( after initialization) FLASH 50 1 Pag in g Ac cess En abled PAGE A 2 Do Not Disturb Enabled 3 Conference Enable/Disable (Per Station) Enabled 4 Ex ecu tive Overri de D isab led 5 Pr ivacy (Per Stat ion) Enabled 6 System Speed Di al Ac cess En abled 7 Line Queuing Enabled 8 P r e fe r r e d L i ne A ns w e r En a b l e d 9 Off-Hoo k Voic e Over (OHVO) Disabled 10 C a ll Fo rwa rd in g En a b led 11 Forc ed Lea st C o st Ro ut in g ( LC R ) D isa b led 12 ACD Sup ervi sor Mo n ito r w/ Barg e-In D isab led 13 Ex ecu tiv e Ov erri de Blo ck D isa b led 14 C O Li ne R in gi ng M u te d Ri ng