Ricoh B230 Service Manual
Have a look at the manual Ricoh B230 Service Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 127 Ricoh manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
SM 5-265 B230/B237 Service Tables ƒ After you do this SP, go out of the SP mode, and then turn the power off. ƒ Do not remove the SD card until the Power LED stops flashing. Search Option 060 This SP uses bit switches to set up the fuzzy search options for the UCS local address book. Bit: Meaning 0: Checks both upper/lower case characters 1: Japan Only 2: Japan Only 3: Japan Only 4 to 7: Not Used Complexity Option 1 062 Use this SP to set the conditions for password entry to access the local address book. Specifically, this SP limits the password entry to upper case and sets the length of the password. [0 to 32 / 0 / 1 /step] ƒ This SP does not normally require adjustment. ƒ This SP is enabled only after the system administrator has set up a group password policy to control access to the address book. 063 Complexity Option 2 DFU 064 Complexity Option 3 DFU 065 Complexity Option 4 DFU 091 FTP Auth Port Setting Specifies the FTP port for getting a distribution server address book that is used in the identification mode. [0 to 65535 / 3671 / 1 /step] 094 Encryption Stat Shows the status of the encryption function for the address book data.
B230/B237 5-266 SM [Rep Resolution Reduction] *CTL - 5847 5847 1 through 5847 8 changes the default settings of image data transferred externally by the Net File page reference function. [ 0 to 5 / 2 / 1 /step] 5847 21 sets the default for JPEG image quality of image files handled by NetFile. “Net files” are jobs to be printed from the document server using a PC and the DeskTopBinder software. 001 Rate for Copy Color 002 Rate for Copy B&W Text 003 Rate for Copy B&W Other 004 Rate for Printer Color 005 Rate for Printer B&W 0: 1x 1: 1/2x 2: 1/3x 3: 1/4x 4: 1/6x 5: 1/8x Network Quality Default for JPEG 021 Sets the default value for the quality of JPEG images sent as NetFile pages. This function is available only with the MLB (Media Link Board) option installed. [5 to 95 / 50 / 1 /step] [Web Service] *CTL - 5848 5848 2 sets the 4-bit switch assignment for the access control setting. Setting of 0001 has no effect on access and delivery from Scan Router. 5848 100 sets the maximum size allowed for downloaded images. The default is equal to 1 gigabyte. 001 ACC Ctrl: Netfile Protocol (Lower 4 bits only) Bit switch settings. 0000: No access control 0001: Denies access to DeskTop Binder. Access and deliveries from Scan Router have no effect on capture.
SM 5-267 B230/B237 Service Tables 002 Access Ctrl: Repository (only Lower 4 bits) 0000: No access control 0001: Denies access to DeskTop Binder. 0010: No writing control 003 Access Control: Doc. Svr. Print (Lower 4 bits) 004 Access Control: User Directory (only Lower 4 bits) 005 Access Cntl: For Cherry(only lower 4bits) 007 Access Ctrl: Comm. Log Fax (Lower 4 bits) 009 Access Ctrl: Job Ctrl (Lower 4 bits) 011 Access Ctrl: Device management (Lower 4 bits) 021 Access Ctrl: Delivery (Lower 4 bits) 022 Access Ctrl: uAdministration (Lower 4bits) Switches access control on and off. 0000: No access control 0001: Denies access to DeskTop Binder. 100 Repository: Download Image Max. Size Specifies the max size of the image data that the machine can download. [1 to 1024 / 1024 / 1 MB /step] 210 Setting: LogType: Job1 211 Setting: LogType: Job2 212 Setting: LogType: Access 213 Setting: Primary Srv 214 Setting: Secondary Srv 215 Setting: Start Time NIA
B230/B237 5-268 SM 216 Setting: Interval Time 217 Setting: Timing 5849 [Installation Date] *CTL - 5849 1 Display The “Counter Clear Day” has been changed to “Installation Date” or “Inst. Date”. 5849 2 Switch to Print Determines whether the installation date is printed on the printout for the total counter. [0 or 1 / 1 / - ] 0: No Print 1: Print 5850 [Address Book Function] *CTL - Replacement of Circuit Classification Japan Only 003 The machine is sold ready to use with a G3 line. This SP allows you to switch all at once to convert to G4 after you add a G4 line. Conversely, if for some reason the G4 line becomes unusable, you can easily switch back to G3. Bluetooth Mode 5851 Sets the operation mode for the Bluetooth Unit. Press either key. [0:Public] [1: Private] [Stamp Data Download] 5853 Use this SP to download the fixed stamp data stored in the firmware of the ROM and copy it to the HDD. This SP can be executed as many times as required. This SP must be executed after replacing or formatting the hard disks. ƒ This SP can be executed only with the hard disks installed.
SM 5-269 B230/B237 Service Tables [Remote ROM Update] 5856 Allows the technician to upgrade the firmware using a local port (IEEE1284) when updating the remote ROM. 002 Local Port *CTL[0 to 1 / 0 / 1/step] 0: Disable 1: Enable 5857 [Save Debug Log] *CTL - On/Off (1:ON 0:OFF) 0: OFF, 1: ON 5857 1 Switches the debug log feature on and off. The debug log cannot be captured until this feature is switched on. Target (2: HDD 3: SD) 2: HDD, 3: SD Card 5857 2 Selects the storage device to save debug logs information when the conditions set with SP5-858 are satisfied. [ 2 to 3 / 2 / 1 /step] [Save to HDD] DFU 005 Saves the debug log in memory to the HDD. A unique file name is generated to avoid overwriting existing file names on the SD Card. Up to 4MB can be copied to an SD Card. 4 MB segments can be copied one by one to each SD Card. 006 Save to SD Card 009 Copy HDD to SD Card (Latest 4 MB) 010 Copy HDD to SD Card (Latest 4 MB Any Key) 011 Erase HDD Debug Data 012 Erase SD Card Debug Data 013 Free Space on SD Card 014 Copy SD to SD (Latest 4 MB)
B230/B237 5-270 SM 015 Copy SD to SD (Latest 4 MB Any Key) 016 Make HDD Debug 017 Make SD Debug [Debug Save When] *CTL - 5858 These SPs select the content of the debugging information to be saved to the destination selected by SP5857-002. SP5858-3 stores one SC specified by number. Refer to Section 4 for a list of SC error codes. 001 Engine SC Error Turns on/off the debug save for SC codes generated by copier engine errors. [0 or 1 / 0 / 1/ step] 0: OFF, 1: ON 002 Controller SC Error Turns on/off the debug save for SC codes generated by GW controller errors. [0 or 1 / 0 / 1/ step] 0: OFF, 1: ON 003 Any SC Error [0 to 65535 / 0 / 1 /step] 004 Jam Turns on/off the debug save for jam errors. [0 or 1 / 0 / 1/ step] 0: OFF, 1: ON 5859 [Debug Save Key No.] *CTL - 001 Key 1 002 Key 2 003 Key 3 004 Key 4 005 Key 5 These SPs allow you to set up to 10 keys for log files for functions that use common memory on the controller board. [–9999999 to 9999999 / 0 / – ]
SM 5-271 B230/B237 Service Tables 006 Key 6 007 Key 7 008 Key 8 009 Key 9 010 Key 10 5860 [SMTP/POP3/IMAP4] *CTL - 020 Partial Mail Receive Timeout [1 to 168 / 72 / – ] Sets the amount of time to wait before saving a mail that breaks up during reception. The received mail is discarded if the remaining portion of the mail is not received during this prescribed time. 021 MDN Response RFC2298 Compliance [0 to 1 / 1 / – ] Determines whether RFC2298 compliance is switched on for MDN reply mail. 0: No 1: Yes 022 SMTP Auth. From Field Replacement [0 to 1 / 0 / – ] Determines whether the FROM item of the mail header is switched to the validated account after the SMTP server is validated. 0: No. “From” item not switched. 1: Yes. “From item switched. 025 SMTP Auth. Direct Setting [0 or 1 / 0 / – ] Selects the authentication method for SMPT. Bit switch: • Bit 0: LOGIN • Bit 1: PLAIN • Bit 2: CRAM MD5 • Bit 3: DIGEST MD5 • Bit 4 to 7: Not used
B230/B237 5-272 SM ƒ This SP is activated only when SMTP authorization is enabled by UP mode. 5866 [E-mail Alert] Not Used 001 Report Validity - Enables or disables the E-mail alert function. [0 or 1 / 0 / – ] 0: Enabled, 1: Disabled 005 Add Date Field *CTL Adds or does not add the date field to the header of the alert mail. [0 or 1 / 0 / – ] 0: Not added, 1: Added 5870 [Common Key Info Writing] 001 Writing *CTL Writes to flash ROM the common proof for validating the device for NRS specifications. 5873 [SD Card Appli Move] 001 Move Exec This SP copies the application programs from the original SD card in SD card slot 3 to an SD card in SD card slot 1 or 2 (slot 1 has the priority to be copied). 002 Undo Exec This SP copies back the application programs from an SD card in SD Card Slot 3 to the original SD card in SD card slot 1 or 2 (slot 1 has the priority to be copied). Use this menu when you have mistakenly copied some programs by using Move Exec (SP5873-1). 5875 [SC Auto Reboot]
SM 5-273 B230/B237 Service Tables 001 Reboot Setting *CTL Enables or disables the automatic reboot function when an SC error occurs. [0 or 1/ 0 / – ] 0: The machine reboots automatically when the machine issues an SC error and logs the SC error code. If the same SC occurs again, the machine does not reboot. 1: The machine does not reboot when an SC error occurs. The reboot is not executed for Type A or C SC codes. 002 Reboot Type *CTL Selects the reboot method for SC. [0 or 1 / 0 / -] 0: Manual reboot, 1: Automatic reboot 5878 [Option Setup] 001 Option Setup - Enables the Data Overwrite Security unit. Press EXECUTE on the operation panel. Then turn the machine off and on. 5881 [Fixed Phrase Block Erasing] 001 - - Deletes the fixed phrase. [WIM Settings] Web Image Monitor Settings 5885 Close or disclose the functions of web image monitor. 020 Document Server ACC Ctrl *CTL 0: OFF, 1: ON Bit Meaning 0: Forbid all document server access (1) 1: Forbid user mode access (1) 2: Forbid print function (1)
B230/B237 5-274 SM 3: Forbid fax TX (1) 4: Forbid scan sending (1) 5: Forbid downloading (1) 6: Forbid delete (1) 7: Reserved [Permit ROM Updating] DFU 5886 This SP determines whether the ROM can be updated. 001 - *CTL [0 or 1 / 0 / 1/step] 0: ON, 1: OFF [Plug & Play Maker/Model Name] Plug & Play Name Selection 5907 Specifies the manufacturer and model name. These names are registered in the NVRAM. If the NVRAM becomes defective, these names should be re-registered. 001 Plug/Play *ENG[0 to 11 / 0 / 1 /step ] FA 0: RICOH Aficio MP C3000 1: RICOH Aficio MP C2500 2: SAVIN C2525 3: SAVIN C3030 4: Gestetner MPC 2500/DSc525 5: Gestetner MPC 3000/DSc530 6: NRG MP C2500 7: NRG MP C3000 8: infotec ISC2525 9: infotec ISC3030 10: LANIER MP C2500/LD425c 11: LANIER MP C3000/LD430c