Home > Ricoh > Printer > Ricoh B230 Service Manual

Ricoh B230 Service Manual

    Download as PDF Print this page Share this page

    Have a look at the manual Ricoh B230 Service Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 127 Ricoh manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    Page
    of 1286
    							 
    SM 5-25 B230/B237 
    Service 
    Tables 
    [Charge AC Current: ML] Charge Roller AC Current Adjustment for MM   
    (Color) 
    2008 
    Displays/sets the AC current target of the charge roller for ML environment 
    (Meddle temperature and Low humidity). DFU 
    001 Environmental Target: Bk  *ENG
    [0 to 3000 / 1040 / 10 μA/step] 
    002 Environmental Target: M  *ENG
    003 Environmental Target: C  *ENG[0 to 3000 / 1030 / 10 μA/step] 
    004  Environmental Target: Y  *ENG
    [0 to 3000 / 1070 / 10 μA/step] 
     
    [Charge AC Current: MM] Charge Roller AC Current Adjustment for MM   
    (Color) 
    2009 
    Displays/sets the AC current target of the charge roller for MM environment 
    (Middle temperature and Middle humidity). DFU 
    001 Environmental Target: Bk  *ENG
    [0 to 3000 / 980 / 10 μA/step] 
    002 Environmental Target: M  *ENG
    003 Environmental Target: C  *ENG[0 to 3000 / 960 / 10 μA/step] 
    004  Environmental Target: Y  *ENG
    [0 to 3000 / 1000 / 10 μA/step] 
     
    [Charge AC Current: MH] Charge Roller AC Current Adjustment for MH   
    (Color) 
    2010 
    Displays/sets the AC current target of the charge roller for MH environment 
    (Middle temperature and High humidity). DFU 
    001 Environmental Target: Bk  *ENG
    [0 to 3000 / 960 / 10 μA/step] 
    002 Environmental Target: M  *ENG
    003 Environmental Target: C  *ENG[0 to 3000 / 940 / 10 μA/step] 
    004  Environmental Target: Y  *ENG
    [0 to 3000 / 970 / 10 μA/step] 
      
    						
    							 
    B230/B237 5-26  SM 
    [Charge AC Current: HH] Charge Roller AC Current Adjustment for HH   
    (Color) 
    2011 
    Displays/sets the AC current target of the charge roller for HH environment 
    (High temperature and High humidity). DFU 
    001 Environmental Target: Bk  *ENG
    [0 to 3000 / 940 / 10 μA/step] 
    002 Environmental Target: M  *ENG
    003 Environmental Target: C  *ENG[0 to 3000 / 930 / 10 μA/step] 
    004  Environmental Target: Y  *ENG
    [0 to 3000 / 960 / 10 μA/step] 
     
    2012 [Charge Output Control]  
    001 AC Voltage  *ENGSelects the AC voltage control type. 
    [0 or 1 / 0 / 1/step] 
    0: Process control   
    1: Manual control (AC voltages are decided 
    with SP2006.) 
     
    2013 [Environmental Correction: PCU] 
    001 Current Environmental: 
    Display *ENGDisplays the environmental condition, which 
    is measured in absolute humidity. 
    [1 to 5 / – / 1 /step] 
    1: LL (LL 
    						
    							 
    SM 5-27 B230/B237 
    Service 
    Tables 
    1: LL, 2: ML, 3: MM, 4: MH, 5: HH   
    003 Absolute Humidity: 
    Threshold 1 *ENGChanges the humidity threshold between 
    LL and ML. 
    [0 to 100 / 4.3 / 0.01 g/m
    3/step] 
    004 Absolute Humidity: 
    Threshold 2 *ENGChanges the humidity threshold between 
    ML and MM. 
    [0 to 100 / 11 . 3 / 0.01 g/m
    3/step] 
    005 Absolute Humidity: 
    Threshold 3 *ENGChanges the humidity threshold between 
    MM and MH. 
    [0 to 100 / 18.0 / 0.01 g/m
    3/step] 
    006 Absolute Humidity: 
    Threshold 4 *ENGChanges the humidity threshold between 
    MH and HH. 
    [0 to 100 / 24.0 / 0.01 g/m
    3/step] 
    007 Current Temp.: Display  *ENGDisplays the current temperature. 
    [0 to 100 / – / 1°C/step] 
    008 Current Relative 
    Humidity: Display *ENGDisplays the current relative humidity. 
    [0 to 100 / – / 1%/step] 
    009 Current Absolute 
    Humidity: Display *ENGDisplays the absolute humidity. 
    [0 to 100 / – / 0.01 g/m3/step] 
    010 Previous Environmental: 
    Display *ENGDisplays the previous environmental 
    condition, which is measured in absolute 
    humidity. 
    [1 to 5 / – / 1 /step] 
    1: LL, 2: ML, 3: MM, 4: MH, 5: HH   
    011 Previous Temp.: Display  *ENGDisplays the previous temperature. 
    [0 to 100 / – / 1°C/step] 
    012 Previous Relative 
    Humidity: Display *ENGDisplays the previous relative humidity. 
    [0 to 100 / – / 1%/step] 
    013 Previous Absolute 
    Humidity: Display *ENGDisplays the previous absolute humidity. 
    [0 to 100 / – / 0.01 g/m3/step]  
    						
    							 
    B230/B237 5-28  SM 
     
    [Color Registration Correction] FA 
    2101 These values are the parameters for the automatic line position adjustment and 
    are adjusted at the factory. However, you must input a value for SP2101-001 
    after replacing the laser optics housing unit. For details, see Laser Optics 
    Housing Unit in the Replacement and Adjustment section. The value should 
    be provided with the new laser optics housing unit. 
    001  Main Dot: Bk  *ENG
      002  Main Dot: M  *ENG
      003  Main Dot: C  *ENG
     004  Main Dot: Y  *ENG[–512 to 511 / 0 / 1 dot/step] 
    005 Subdot: Bk  *ENG
    006 Subdot: M  *ENG
    007 Subdot: C  *ENG
    008 Subdot: Y  *ENG[–16384 to 16383 / 0 / 1 line/step] 
     
    2102 [Magnification Adjustment] DFU 
    001 Main Mag.: High Speed: 
    Bk *ENG
     002 Main Mag.: Medium 
    Speed: Bk *ENG
     003 Main Mag.: Low Speed: 
    Bk *ENG
     004 Main Mag.: High Speed: 
    M *ENG
    005 Main Mag.: Medium 
    Speed: M *ENGThese are results of the main scan length 
    adjustment. 
    [0 to 560 / 280 / 1 /step]  
    						
    							 
    SM 5-29 B230/B237 
    Service 
    Tables 
    006 Main Mag.: Low Speed: 
    M *ENG
    007 Main Mag.: High Speed: 
    C *ENG
    008 Main Mag.: Medium 
    Speed: C *ENG
    009  Main Mag.: Low Speed: C *ENG
    010 Main Mag.: High Speed: 
    Y *ENG
    011 Main Mag.: Medium 
    Speed: Y *ENG
    012  Main Mag.: Low Speed: Y *ENG
     
    2103 [Erase Margin Adjustment] (Area, Paper Size) 
     Adjusts the erase margin by changing the activation timing of the registration 
    clutch. 
      001  Lead Edge Width  *ENG
     002  Trail. Edge Width  *ENG[0 to 9.9 / 4.2 / 0.1 mm/step] 
     003  Left  *ENG
     004  Right  *ENG[0 to 9.9 / 2 / 0.1 mm/step] 
      005  Lead Edge Width: Thin  *ENG
    [0 to 9.9 / 5 / 0.1 mm/step] 
     006  Duplex Trail. L Size  *ENG
     007  Duplex Trail. M Size  *ENG
     008  Duplex Trail. S Size  *ENG[0 to 4 / 0 / 0.1 mm/step] 
     009  Duplex Left Edge  *ENG
      010  Duplex Right Edge  *ENG[0 to 1.5 / 0.3 / 0.1 mm/step]  
    						
    							 
    B230/B237 5-30  SM 
     
    2105 [LD Power Adj.] (Process Speed, Color) 
     Displays the LD power of each color for each process speed.   
    Each LD power setting is decided by process control. 
      001  High Speed: Bk  *ENG
      002  High Speed: M  *ENG
      003  High Speed: C  *ENG
     004  High Speed: Y  *ENG
      005  Middle Speed: Bk  *ENG
      006  Middle Speed: M  *ENG
      007  Middle Speed: C  *ENG
     008  Middle Speed: Y  *ENG
     009  Low Speed: Bk  *ENG
     010  Low Speed: M  *ENG
    011 Low Speed: C  *ENG
    012 Low Speed: Y  *ENG[50 to 120 / 100 / 1%/step] 
    Decreasing a value makes lines thinner on 
    the output. 
    Increasing a value makes lines thicker on 
    the output. 
     
    2106 [Polygon Rotation Time]  
     
    Adjusts the time of the polygon motor rotation. DFU 
     001  Warming-Up  *ENG
     002  Job End  *ENG[0 to 60 / 10 / 1 sec/step] 
     
    [Image Parameter]  
    2107 
    DFU 
    001  Image Gamma Flag  *ENG
    [0 or 1 / 1 / 1 /step]  
    						
    							 
    SM 5-31 B230/B237 
    Service 
    Tables 
      002  Shading Correction Flag  *ENG
    [0 or 1 / 1 / 1 /step] 
     
    [Test Pattern]  
    2109 
    Generates the test pattern using COPY Window tab in the LCD. 
    003 Pattern Selection  - [0 to 23 / 0 / 1/step] 
    0 None 
    1: 1-dot line pattern (Vertical) 
    2: 2-dot line pattern (Vertical) 
    3: 1-dot line pattern (Horizontal) 
    4: 2-dot line pattern (Horizontal) 
    5: 1-dot grid pattern (Vertical) 
    6: 1-dot grid pattern (Horizontal) 
    7: 1-dot grid pattern (Fine) 
    8: 1-dot grid pattern (Rough) 
    9: 1-dot slant pattern (Fine) 
    10: 1-dot slant pattern (Rough) 
    11. 1-dot pattern 
    12. 2-dot pattern 
    13. 4-dot pattern 
    14. 1-dot trimming pattern   
    15: None 
    16: Cross stitch: main-scan 
    17: Belt pattern (Horizontal) 
    18: Belt pattern (Vertical) 
    19: Checkered flag 
    20: Gray scale (Vertical) 
    21: Gray scale (Horizontal) 
    22: None 
    23: Solid 
     005  Color Selection  - Specifies the color for the test pattern. 
    [1 to 4 / 1 / 1/step] 
    1: All colors, 2: Magenta, 3: Yellow, 4: Cyan
    006  Density: Bk  -  Specifies the color density for the test  
    						
    							 
    B230/B237 5-32  SM 
    007 Density: M  - 
    008 Density: C  - 
    009 Density: Y  - pattern. 
    [0 to 15 / 15 / 1 /step] 
    0: Lightest density 
    15: Darkest density 
     
    2111 [Forced Line Position Adj.]  
    001 Mode a  - Executes the fine line position adjustment 
    twice. 
    If this SP is not completed (NG is 
    displayed), do SP2111-003 first and then try 
    this SP again. 
     002  Mode b  - Executes the fine line position adjustment 
    once. 
    If this SP is not completed, do SP2111-003 
    first and then try this SP again. 
    003 Mode c  - Executes the rough line position adjustment 
    once. 
    After doing this SP, make sure to execute 
    SP2111-001 or -002. Otherwise, the line 
    position adjustment is not perfectly done. 
     
    2112 [TM/ID Sensor Check] ID Sensor Check FA 
    001 Execute   This SP is used to check the ID sensors at 
    the factory. The results of this SP are 
    displayed in SP2140 to SP2145. 
     
    [Skew Adjustment]  
    2117 Specifies a skew adjustment value for the skew motor M, C or Y.   
    These SPs must be used when a new laser optics housing unit is installed or 
    when SC285 occurs. For details, see Laser Optics Housing Unit in the 
    Replacement and Adjustment section.  
    						
    							 
    SM 5-33 B230/B237 
    Service 
    Tables 
    001 Pulse: M  *ENG
     002  Pulse: C  *ENG
    003 Pulse: Y  *ENG[–100 to 100 / 0 / 1 pulse/step] 
     
    2118 [Skew Adjustment]  
    001 Pulse: M  *ENG
     002  Pulse: C  *ENG
    003 Pulse: Y  *ENGChanges the current skew adjustment 
    values to the values specified with SP2117. 
    These SPs must be used when a new laser 
    optics housing unit is installed or when 
    SC285 occurs. For details, see Laser 
    Optics Housing Unit in the Replacement 
    and Adjustment  section. 
     
    [Skew Adjustment Display]  
    2119 
    Displays the current skew adjustment value for each skew motor. 
    001 M  *ENG
     002  C  *ENG
    003 Y  *ENG[–50 to 50 / 0 / 1 pulse/step] 
     
    [ID Sensor Check Result] DFU 
    2140 Displays the results of the ID sensor check. 
    Bk, M, C, Y: ID sensors for the process control 
    Front, Center, Rear: ID sensors for the automatic line position adjustment 
    001 Bk  *ENG
     002  M  *ENG
    003 C  *ENG
    004 Y  *ENG[0 to 1024 / - / 1/step]  
    						
    							 
    B230/B237 5-34  SM 
    005 Front  *ENG
    006 Center   *ENG
    007 Rear  *ENG
     
    [ID Sensor Check Result: Ave.] DFU 
    2141 Displays the average result values of the ID sensor check. 
    Bk, M, C, Y: ID sensors for the process control 
    Front, Center, Rear: ID sensors for the automatic line position adjustment 
    001 Bk  *ENG
     002  M  *ENG
    003 C  *ENG
    004 Y  *ENG
    005 Front  *ENG
    006 Center   *ENG
    007 Rear  *ENG[0 to 5 / 0 / 0.01V/step] 
     
    [ID Sensor Check Result] DFU 
    2142 Displays the maximum result values of the ID sensor check. 
    Bk, M, C, Y: ID sensors for the process control 
    Front, Center, Rear: ID sensors for the automatic line position adjustment 
    001 Maximum: Bk  *ENG
     002  Maximum: M  *ENG
    003 Maximum: C  *ENG
    004 Maximum: Y  *ENG
    005 Maximum: Front  *ENG[0 to 5 / 0 / 0.01V/step]  
    						
    All Ricoh manuals Comments (0)