Home > Ricoh > Printer > Ricoh B230 Service Manual

Ricoh B230 Service Manual

    Download as PDF Print this page Share this page

    Have a look at the manual Ricoh B230 Service Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 127 Ricoh manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    Page
    of 1286
    							Bit Switches 
    SM 91 B786 
    B786 
    Fax Option 
    0 1  0 1 12.0 Kbps 
    0 1  1 0 14.4 Kbps 
    0 1  1 1 16.8 Kbps 
    1 0  0 0 19.2 Kbps 
    1 0  0 1 21.6 Kbps 
    1 0  1 0 24.0 Kbps 
    1 0  1 1 26.4 Kbps 
    1 1  0 0 28.8 Kbps 
    1 1  0 1 31.2 Kbps 
    1 1  1 0 33.6 Kbps 
            
    Modem setting for reception 
    Sets the modem type for reception. The default is 0100 (V27ter, V29, V17). 
    Bit 7  Bit 6   Bit 5  Bit 4   
    0 0  0 1 V27ter 
    0 0  1 0 V27ter, V29 
    0 0  1 1 V27ter, V29, V33 
    (invalid) 
    0  1  0  0  V27ter, V29, V17 
    0 1  0 1 V27ter, V29, V17, 
    V34* 
    4-7 
    *V34 is not supported for IP-Fax communication. 
     
    IP Fax Switch 07 [SP No. 1-111-008] 
    No. FUNCTION COMMENTS 
    0 TSI information  
    0: Not added, 1: Added Adds or does not add TSI information to 
    NSS(S). 
    1 DCN transmission setting at T1 
    timeout 
    0: Not transmitted, 1: Transmitted Transmits or does not transmit DCN at T1 
    timeout. 
    2 Not used  Do not change this setting. 
    3 Hang up setting at DIS reception 
    disabled 
    0: No hang up Sets whether the machine disconnects after 
    DIS reception.  
    						
    							Bit Switches 
    B786 92  SM 
    1: Hang up after transmitting DCN 
    4 Number of times for training  
    0: 1 time, 1: 2 times Selects the number of times training is done 
    at the same bit rate. 
    5 Space CSI transmission setting at 
    no CSI registration 
    0: Not transmitted, 1: Transmitted When 0 is selected, frame data is enabled. 
    When 1 is selected, the transmitted data is 
    all spaces. 
    6-7 Not used  Do not change these settings. 
     
    IP Fax Switch 08 [SP No. 1-111-009] 
    No. FUNCTION COMMENTS 
    0-1 T1 timer adjustment 
    Adjusts the T1 timer. 
    The default is 00 (35 seconds). 
    Bit 1: 0, Bit 0: 0 = 35 sec 
    Bit 1: 0, Bit 0: 1 = 40 sec 
    Bit 1: 1, Bit 0: 0 = 50 sec 
    Bit 1: 1, Bit 0: 1 = 60 sec - 
    2-3 T4 timer adjustment 
    Adjust the T4 timer. 
    The default is 00 (3 seconds). 
    Bit 3: 0, Bit 2: 0 = 3 sec 
    Bit 3: 0, Bit 2: 1 = 3.5 sec 
    Bit 3: 1, Bit 2: 0 = 4 sec 
    Bit 3: 1, Bit 2: 1 = 5 sec - 
    4-5 T0 timer adjustment  
    Bit 5: 0, Bit 4: 0 = 75 sec 
    Bit 5: 0, Bit 4: 1 = 120 sec 
    Bit 5: 1, Bit 4: 0 = 180 sec 
    Bit 5: 1, Bit 4: 1 = 240 sec Adjusts the fail safe timer. This timer sets the 
    interval between setup data transmission 
    and T.38 phase decision. If your destination 
    return is late on the network or G3 fax return 
    is late, adjust the longer interval timer. 
    The default is 00 (75 seconds). 
    6-7 Not used  Do not change these settings. 
      
    						
    							NCU Parameters 
    SM 93 B786 
    B786 
    Fax Option 
    4.4 NCU PARAMETERS 
    The following tables give the RAM addresses and the parameter calculation units that the 
    machine uses for ringing signal detection and automatic dialing. The factory settings for 
    each country are also given. Most of these must be changed by RAM read/write (SP2-
    102), but some can be changed using NCU Parameter programming (SP2-103, 104 and 
    105); if SP2-103, 104 and 105 can be used, this will be indicated in the Remarks column. 
    The RAM is programmed in hex code unless (BCD) is included in the Unit column. 
     
    ƒ  The following addresses describe settings for the standard NCU. 
    ƒ  Change the fourth digit from “5” to “6” (e.g. 680500 to 680600) for the settings for 
    the first optional G3 interface unit and from “5” to “7” (e.g. 680700) for the settings 
    for the second optional G3 interface unit. 
    Address Function 
    Country/Area code for NCU parameters 
    Use the Hex value to program the country/area code directly into this 
    address, or use the decimal value to program it using SP2-103-001 
    Country 
    /Area Decimal Hex Country 
    /Area Decimal Hex 
    France    00  00  USA    17  11 
    Germany    01  01  Asia    18  12 
    UK    02  02  Hong Kong  20  14 
    Italy    03  03  South Africa  21  15 
    Austria    04  04  Australia    22  16 
    Belgium    05  05  New Zealand 26  17 
    Denmark    06  06  Singapore    24  18 
    Finland    07  07  Malaysia    25  19 
    Ireland    08  08  China    26  1A 
    Norway    09  09  Taiwan    27  1B 
    Sweden    10  0A  Korea  28  1C 
    Switzerland    11  0B  Turkey  32  20 
    Portugal    12  0C  Greece    33  21 
    680500 
    Holland    13  0D  Hungary  34  22  
    						
    							NCU Parameters 
    B786 94  SM 
    Address Function 
    Spain    14  0E  Czech  35  23 
    Israel    15  0F  Poland  36  24 
     
    Address Function Unit Remarks 
    680501  Line current detection time  
    680502  Line current wait time  
    680503  Line current drop detect time 20 ms Line current detection is 
    disabled. 
    Line current is not 
    detected if 680501 
    contains FF. 
    680504 PSTN dial tone frequency upper 
    limit (high byte) 
    680505 PSTN dial tone frequency upper 
    limit (low byte) Hz (BCD) If both addresses 
    contain FF(H), tone 
    detection is disabled. 
    680506 PSTN dial tone frequency lower 
    limit (high byte) 
    680507 PSTN dial tone frequency lower 
    limit (low byte) Hz (BCD) If both addresses 
    contain FF(H), tone 
    detection is disabled. 
    680508  PSTN dial tone detection time 
    680509  PSTN dial tone reset time (LOW) 
    68050A  PSTN dial tone reset time (HIGH) 
    68050B PSTN dial tone continuous tone 
    time 
    68050C PSTN dial tone permissible drop 
    time If 680508 contains 
    FF(H), the machine 
    pauses for the pause 
    time (address 68050D / 
    68050E). 
    Italy: See Note 2. 
    68050D  PSTN wait interval (LOW) 
    68050E  PSTN wait interval (HIGH) 20 ms 
    - 
    68050F  PSTN ring-back tone detection time 20 ms Detection is disabled if 
    this contains FF. 
    680510 PSTN ring-back tone off detection 
    time 20 ms  - 
    680511 PSTN detection time for silent 
    period after ring-back tone detected 
    (LOW) 20 ms  - 
    680512 PSTN detection time for silent 
    period after ring-back tone detected 
    (HIGH) 20 ms  -  
    						
    							NCU Parameters 
    SM 95 B786 
    B786 
    Fax Option 
    Address Function Unit Remarks 
    680513 PSTN busy tone frequency upper 
    limit (high byte) 
    680514 PSTN busy tone frequency upper 
    limit (low byte) Hz (BCD) If both addresses 
    contain FF(H), tone 
    detection is disabled. 
    680515 PSTN busy tone frequency lower 
    limit (high byte) 
    680516 PSTN busy tone frequency lower 
    limit (low byte) Hz (BCD) If both addresses 
    contain FF(H), tone 
    detection is disabled. 
    680517 PABX dial tone frequency upper 
    limit (high byte) 
    680518 PABX dial tone frequency upper 
    limit (low byte) Hz (BCD) If both addresses 
    contain FF(H), tone 
    detection is disabled. 
    680519 PABX dial tone frequency lower 
    limit (high byte) 
    68051A PABX dial tone frequency lower 
    limit (low byte) Hz (BCD) If both addresses 
    contain FF(H), tone 
    detection is disabled. 
    68051B  PABX dial tone detection time 
    68051C  PABX dial tone reset time (LOW) 
    68051D  PABX dial tone reset time (HIGH) 
    68051E PABX dial tone continuous tone 
    time 
    68051F PABX dial tone permissible drop 
    time If 68051B contains FF, 
    the machine pauses for 
    the pause time (680520 
    / 680521). 
    680520  PABX wait interval (LOW) 
    680521  PABX wait interval (HIGH) 20 ms 
    - 
    680522  PABX ringback tone detection time  20 ms 
    680523 PABX ringback tone off detection 
    time 20 ms If both addresses 
    contain FF(H), tone 
    detection is disabled. 
    680524  PABX detection time for silent 
    period after ringback tone detected 
    (LOW) 20 ms 
    680525  PABX detection time for silent 
    period after ringback tone detected 
    (HIGH) 20 ms If both addresses 
    contain FF(H), tone 
    detection is disabled. 
    680526 PABX busy tone frequency upper 
    limit (high byte) Hz (BCD) If both addresses 
    contain FF(H), tone  
    						
    							NCU Parameters 
    B786 96  SM 
    Address Function Unit Remarks 
    680527 PABX busy tone frequency upper 
    limit (low byte) detection is disabled. 
    680528 PABX busy tone frequency lower 
    limit (high byte) 
    680529 PABX busy tone frequency lower 
    limit (low byte) Hz (BCD) If both addresses 
    contain FF(H), tone 
    detection is disabled. 
    68052A  Busy tone ON time: range 1 
    68052B  Busy tone OFF time: range 1 
    68052C  Busy tone ON time: range 2 
    68052D  Busy tone OFF time: range 2 
    68052E  Busy tone ON time: range 3 20 ms 
    68052F  Busy tone OFF time: range 3 
    680530  Busy tone ON time: range 4 
    680531  Busy tone OFF time: range 4 
    680532 Busy tone continuous tone 
    detection time 20 ms - 
    680533 Busy tone signal state time tolerance for all ranges, and number of cycles 
    required for detection (a setting of 4 cycles means that ON-OFF-ON or OFF-
    ON-OFF must be detected twice). 
    Tolerance (±) 
    Bit 1: 0, Bit 0: 0 = 75% Bits 2 and 3 must always be kept at 0. 
    Bit 1: 0, Bit 0: 0 = 50% Bits 2 and 3 must always be kept at 0. 
    Bit 1: 0, Bit 0: 0 = 25% 
    Bit 1: 0, Bit 0: 0 = 12.5%  
    Bits 7, 6, 5, 4 - number of cycles required for cadence detection 
    680534 International dial tone frequency 
    upper limit (high byte) 
    680535 International dial tone frequency 
    upper limit (low byte) Hz (BCD) If both addresses 
    contain FF(H), tone 
    detection is disabled. 
    680536 International dial tone frequency 
    lower limit (high byte) 
    680537 International dial tone frequency 
    lower limit (low byte) Hz (BCD) If both addresses 
    contain FF(H), tone 
    detection is disabled. 
    680538 International dial tone detection 
    time  
    680539 International dial tone reset time 
    (LOW) 20 ms If 680538 contains FF, 
    the machine pauses for 
    the pause time (68053D 
    / 68053E).  
    						
    							NCU Parameters 
    SM 97 B786 
    B786 
    Fax Option 
    Address Function Unit Remarks 
    68053A International dial tone reset time 
    (HIGH) 
    68053B International dial tone continuous 
    tone time 
    68053C International dial tone permissible 
    drop time Belgium: See Note 2. 
    68053D International dial wait interval 
    (LOW) 
    68053E International dial wait interval 
    (HIGH) - 
    68053F Country dial tone upper frequency 
    limit (HIGH) 
    680540 Country dial tone upper frequency 
    limit (LOW) If both addresses 
    contain FF(H), tone 
    detection is disabled. 
    680541 Country dial tone lower frequency 
    limit (HIGH) 
    680542 Country dial tone lower frequency 
    limit (LOW) Hz (BCD) 
    If both addresses 
    contain FF(H), tone 
    detection is disabled. 
    680543  Country dial tone detection time 
    680544  Country dial tone reset time (LOW) 
    680545  Country dial tone reset time (HIGH)20 ms If 680543 contains FF, 
    the machine pauses for 
    the pause time (680548 
    / 680549). 
    680546 Country dial tone continuous tone 
    time - - 
    680547 Country dial tone permissible drop 
    time 
    680548  Country dial wait interval (LOW) 
    680549  Country dial wait interval (HIGH) 20 ms  - 
    68054A Time between opening or closing 
    the DO relay and opening the OHDI 
    relay 1 ms See Notes 3, 6 and 8. 
    SP2-103-012 
    (parameter 11). 
    68054B  Break time for pulse dialing  1 ms See Note 3.  
    SP2-103-013 
    (parameter 12). 
    68054C  Make time for pulse dialing  1 ms See Note 3.  
    SP2-103-014 
    (parameter 13).  
    						
    							NCU Parameters 
    B786 98  SM 
    Address Function Unit Remarks 
    68054D Time between final OHDI relay 
    closure and DO relay opening or 
    closing 1 ms See Notes 3, 6 and 8.  
    SP2-103-015 
    (parameter 14). 
    This parameter is only 
    valid in Europe. 
    68054E Minimum pause between dialed 
    digits (pulse dial mode) See Note 3 and 8. SP2-
    103-016 (parameter 15).
    68054F Time waited when a pause is 
    entered at the operation panel 20 ms 
    SP2-103-017 
    (parameter 16). See 
    Note 3. 
    680550  DTMF tone on time SP2-103-018 
    (parameter 17). 
    680551  DTMF tone off time 1 ms 
    SP2-103-019 
    (parameter 18). 
    680552 Tone attenuation level of DTMF 
    signals while dialing -N x 0.5  –
    3.5 dBm SP2-103-020 
    (parameter 19).  
    See Note 5. 
    680553 Tone attenuation value difference 
    between high frequency tone and 
    low frequency tone in DTMF 
    signals -dBm x 0.5 SP2-103-021 
    (parameter 20). 
    The setting must be less 
    than –5dBm, and should 
    not exceed the setting at 
    680552h above. 
    See Note 5. 
    680554 PSTN: DTMF tone attenuation level 
    after dialling -N x 0.5  –
    3.5 dBm SP2-103-022 
    (parameter 21). See 
    Note 5. 
    680555 ISDN: DTMF tone attenuation level 
    after dialling -dBm x 0.5  See Note 5 
    680556 Not used  - Do not change the 
    settings. 
    680557 Time between 68054Dh (NCU 
    parameter 14) and 68054Eh (NCU 
    parameter 15) 1 ms This parameter takes 
    effect when the country 
    code is set to France. 
    680558 Not used  - Do not change the 
    setting. 
    680559 Grounding time (ground start 
    mode) 20 ms The Gs relay is closed 
    for this interval. 
    68055A  Break time (flash start mode)  1 ms The OHDI relay is open 
    for this interval.  
    						
    							NCU Parameters 
    SM 99 B786 
    B786 
    Fax Option 
    Address Function Unit Remarks 
    68055B International dial access code 
    (High) 
    68055C International dial access code 
    (Low) BCD For a code of 100: 
    68055B - F1   
    68055C - 00   
    68055D  PSTN access pause time  20 ms This time is waited for 
    each pause input after 
    the PSTN access code. 
    If this address contains 
    FF[H], the pause time 
    stored in address 
    68054F is used. 
    Do not set a number 
    more than 7 in the UK.  
    68055E Progress tone detection level, and 
    cadence detection enable flags Bit 7: 0, Bit 6: 0, Bit 5: 0 = -25.0 dBm 
    Bit 7: 0, Bit 6: 0, Bit 5: 1 = -35.0 dBm 
    Bit 7: 0, Bit 6: 1, Bit 5: 0 = -30.0 dBm 
    Bit 7: 1, Bit 6: 0, Bit 5: 0 = -40.0 dBm 
    Bit 7: 1, Bit 6: 1, Bit 5: 0 = -49.0 dBm 
    Bits 2, 0 - See Note 2. 
    68055F 
     To  
    680564 Not used - Do not change the 
    settings. 
    680565  Long distance call prefix (HIGH)  BCD 
    680566  Long distance call prefix (LOW)  BCD For a code of 0: 
     680565 – FF 
     680566 - FF 
    680567 
    to 
    680571 Not used - Do not change the 
    settings. 
    680572 Acceptable ringing signal 
    frequency: range 1, upper limit SP2-103-003 
    (parameter 02). 
    680573 Acceptable ringing signal 
    frequency: range 1, lower limit SP2-103-004 
    (parameter 03). 
    680574 Acceptable ringing signal 
    frequency: range 2, upper limit SP2-103-005 
    (parameter 04). 
    680575 Acceptable ringing signal 
    frequency: range 2, lower limit 1000/ N 
    (Hz). 
    SP2-103-006 
    (parameter 05). 
    680576 Number of rings until a call is 
    detected 1 SP2-103-007 
    (parameter 06). 
    The setting must not be 
    zero. 
    680577 Minimum required length of the first 
    ring 20 ms See Note 4. 
    SP2-103-008  
    						
    							NCU Parameters 
    B786 100  SM 
    Address Function Unit Remarks 
    (parameter 07). 
    680578 Minimum required length of the 
    second and subsequent rings 20 ms SP2-103-009 
    (parameter 08). 
    680579 Ringing signal detection reset time 
    (LOW) SP2-103-010 
    (parameter 09). 
    68057A Ringing signal detection reset time 
    (HIGH) 20 ms 
    SP2-103-011 (parameter 
    10). 
    68057B 
    to 
    680580 Not used - Do not change the 
    settings. 
    680581 Interval between dialing the last 
    digit and switching the Oh relay 
    over to the external telephone 
    when dialing from the operation 
    panel in handset mode. 20 ms  Factory setting: 500 ms 
    680582 Bits 0 and 1 - Handset off-hook detection time 
    Bit 1:0, Bit 0: 0 = 200 ms 
    Bit 1:0, Bit 0: 1 = 800 ms 
    Other Not used 
    Bits 2 and 3 - Handset on-hook detection time 
    Bit 3: 0, Bit 2: 0 = 200 ms 
    Bit 3: 0, Bit 2: 1 = 800 ms 
    Other Not used 
    Bits 4 to 7 - Not used - 
    680583 
    To  
    6805A0 Not used - Do not change the 
    settings. 
    6805A1 Acceptable CED detection 
    frequency upper limit (high byte) 
    6805A2 Acceptable CED detection 
    frequency upper limit (low byte) BCD (Hz) If both addresses 
    contain FF(H), tone 
    detection is disabled. 
    6805A3 Acceptable CED detection 
    frequency lower limit (high byte) 
    6805A4 Acceptable CED detection 
    frequency lower limit (low byte) BCD (Hz) If both addresses 
    contain FF(H), tone 
    detection is disabled. 
    6805A5  CED detection time 20 ms ± 20 
    ms Factory setting: 200 ms  
    6805A6 Acceptable CNG detection 
    frequency upper limit (high byte) 
    6805A7  Acceptable CNG detection BCD (Hz) If both addresses 
    contain FF(H), tone 
    detection is disabled.  
    						
    All Ricoh manuals Comments (0)

    Related Manuals for Ricoh B230 Service Manual