Ricoh B230 Service Manual
Have a look at the manual Ricoh B230 Service Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 127 Ricoh manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
SM 5-135 B230/B237 Service Tables (77 mm/s): 2nd Side 003 Paper Transfer: FINE: 1st Side *ENG 004 Paper Transfer: FINE: 2nd Side *ENGNot used 005-008 Adjusts the environment coefficient for each mode. When the environment is detected as HH, SP2851 is multiplied by these SP values. 005 Separation DC: Thick 1 (77 mm/s): 1st Side *ENG 006 Separation DC: Thick 1 (77 mm/s): 2nd Side: *ENG[10 to 250 / 80 / 5%/step] 007 Separation DC: FINE: 1st Side *ENG 008 Separation DC: FINE: 2nd Side *ENGNot used [OPC Drum Brake Time] 2901 Adjusts the time when the OPC drum motor reverses from normal rotation after job end. DFU 001 Plain *ENG 002 Thick 1 *ENG 003 Thick 2 & FINE *ENG[100 to 1500 / 500 / 10 msec/step] [OPC Drum Reverse Time] 2902 Adjusts the time for how long the OPC drum motor reverses after job end. DFU 001 All: BW *ENG 002 All: FC *ENG[0 to 200 / 40 / 10 msec/step]
B230/B237 5-136 SM [Image Transfer Roller Brake Time] 2903 Adjusts the time when the image transfer belt motor reverses from normal rotation after job end. DFU 003 Plain *ENG 004 Thick 1 *ENG 005 Thick 2 & FINE *ENG[100 to 1500 / 500 / 10 msec/step] [OPC Drum Reverse Time] 2904 Adjusts the time for how long the image transfer belt motor reverses after job end. DFU 003 All *ENG [0 to 200 / 30 / 10 msec/step] [ACS Setting (FC to Bk)] 2907 Adjusts the threshold for moving away the image transfer belt from the color PCUs. This SP moves the image transfer belt away from the color PCUs when the number of B/W image printouts reaches the number of sheets specified with this SP after consecutive full color image printouts in the full color mode. If this SP is set to 0, the image transfer belt does not move away. 001 Continuous Bk Pages *ENG [0 to 10 / 0 / 1 sheet/step] [GainAdjust] Gain Adjustment of Image Transfer Belt Motor 2908 DFU 001 154 mm/sec *ENG 002 138 mm/sec *ENG 003 115 mm/sec *ENG 004 77 mm/sec *ENG[0 or 1 / 1 / 1/step]] 0: High speed (Low level) 1: Low speed (High level)
SM 5-137 B230/B237 Service Tables [Motor Start Control] 2909 Not used 001 On *ENG[0 to 1 / 0 / 1 sheet/step] 0: normal, 1: synchro [Motor Stop Control] 2910 Not used 001 On *ENG[0 to 1 / 0 / 1 sheet/step] 0: normal, 1: synchro [Drum Stop Timing] OPC Drum Motor Stop Timing Adjustment 2911 Not used 001 Bk *ENG 002 MCY *ENG[0 to 360 / 30 / 6 deg/step] [Gear Phase Control Result] 2912 DFU 001 Bk - M *ENG [–180 to 180 / 0 / 1 deg/step] [Gear Phase Control] 2913 Enables or disables the OPC gear phase adjustment after job end. 001 Job End *ENG[0 or 1 / 1 / 1/step] 0: OFF, 1: ON 2914 [Dust Shield Shutter Motor]
B230/B237 5-138 SM 001 Stop Delay: Open *ENG 002 Stop Delay: Close *ENGDFU [1 to 50 / 38 / 1 ms/step] 003 Open Execution *ENGOpens the shutter on the laser optics housing unit manually for test purposes. 004 Close Execution *ENGCloses the shutter on the laser optics housing unit manually for test purposes. 007 Presence *ENG Not used [GainAdjust] Gain Adjustment of OPC Bk Drum Motor 2915 DFU 001 154 mm/sec *ENG 002 138 mm/sec *ENG 003 115 mm/sec *ENG 004 77 mm/sec *ENG[0 or 1 / 0 / 1/step] 0: TGAIN: High, 1: GAIN: Low [GainAdjust] Gain Adjustment of OPC MCY Drum Motor 2916 DFU 001 154 mm/sec *ENG 002 138 mm/sec *ENG 003 115 mm/sec *ENG 004 77 mm/sec *ENG[0 or 1 / 0 / 1/step] 0: TGAIN: High, 1: GAIN: Low [SecondaryFB: Threshold] Paper Transfer Roller Feed-back: Threshold Adjustment 2930 Adjusts the threshold between high resistance (division 1) and low resistance (division 2) at the paper transfer roller. This SP affects SP2931 to SP2939.
SM 5-139 B230/B237 Service Tables 001 Voltage *ENG [0 to 7000 / 5000 / 10 –V/step] [SecondaryFB: Plain] 2931 Adjusts the upper limit voltage for the paper transfer roller. These SPs are only used for plain paper use in full color mode. 001 Limit Voltage: Division 1 *ENG [0 to 7000 / 6000 / 10 –V/step] 002 Limit Voltage: Division 2 *ENG [0 to 7000 / 5000 / 10 –V/step] [SecondaryFB: Thin] 2932 Adjusts the upper limit voltage for the paper transfer roller. These SPs are only used for thin paper use in full color mode. 001 Limit Voltage: Division 1 *ENG [0 to 7000 / 6000 / 10 –V/step] 002 Limit Voltage: Division 2 *ENG [0 to 7000 / 5000 / 10 –V/step] [SecondaryFB: Special 1] 2933 Adjusts the upper limit voltage for the paper transfer roller. These SPs are only used for special 1 paper use in full color mode. 001 Limit Voltage: Division 1 *ENG [0 to 7000 / 6000 / 10 –V/step] 002 Limit Voltage: Division 2 *ENG [0 to 7000 / 5000 / 10 –V/step] [SecondaryFB: Special 2] 2934 Adjusts the upper limit voltage for the paper transfer roller. These SPs are only used for special 2 paper use in full color mode. 001 Limit Voltage: Division 1 *ENG [0 to 7000 / 6000 / 10 –V/step] 002 Limit Voltage: Division 2 *ENG [0 to 7000 / 5000 / 10 –V/step]
B230/B237 5-140 SM [SecondaryFB: Thick 1] 2935 Adjusts the upper limit voltage for the paper transfer roller. These SPs are only used for thick 1 paper use in full color mode. 001 Limit Voltage: Division 1 *ENG [0 to 7000 / 6000 / 10 –V/step] 002 Limit Voltage: Division 2 *ENG [0 to 7000 / 5000 / 10 –V/step] [SecondaryFB: Thick 2] 2936 Adjusts the upper limit voltage for the paper transfer roller. These SPs are only used for thick 2 paper use in full color mode. 001 Limit Voltage: Division 1 *ENG [0 to 7000 / 6000 / 10 –V/step] 002 Limit Voltage: Division 2 *ENG [0 to 7000 / 5000 / 10 –V/step] [SecondaryFB: Thick 3] 2937 Adjusts the upper limit voltage for the paper transfer roller. These SPs are only used for thick 3 paper use in full color mode. 001 Limit Voltage: Division 1 *ENG [0 to 7000 / 6000 / 10 –V/step] 002 Limit Voltage: Division 2 *ENG [0 to 7000 / 5000 / 10 –V/step] [SecondaryFB: OHP] 2938 Adjusts the upper limit voltage for the paper transfer roller. These SPs are only used for OHP paper use in full color mode. 001 Limit Voltage: Division 1 *ENG [0 to 7000 / 6000 / 10 –V/step] 002 Limit Voltage: Division 2 *ENG [0 to 7000 / 5000 / 10 –V/step] [SecondaryFB: Special 3] 2939 Adjusts the upper limit voltage for the paper transfer roller. These SPs are only
SM 5-141 B230/B237 Service Tables used for special 3 paper use in full color mode. 001 Limit Voltage: Division 1 *ENG [0 to 7000 / 6000 / 10 –V/step] 002 Limit Voltage: Division 2 *ENG [0 to 7000 / 5000 / 10 –V/step] SP3-XXX (Process) 3011 [Process Cont. Manual Execution] 001 Normal Executes the normal process control manually (potential control). Check the result with SP3-325-001 and 3-012-001 after executing this SP. 002 Density Adjustment Executes the toner density adjustment manually. 003 Pre-ACC Executes the process control that is normally done before ACC. The type of process control is selected with SP3-041-004. 004 Full MUSIC Executes the process control that is normally done at the same time as MUSIC. This SP does the MUSIC (line position adjustment) twice. 005 Normal MUSIC Executes the process control that is normally done at the same time as MUSIC. This SP does the MUSIC (line position adjustment) once. [Process Cont. Check Result] Process Control Self-check Result 3012 Displays the result of the latest process control self-check. All colors are displayed. The results are displayed in the order “Y C M K” e.g., 11 (Y) 99 (C) 11 (M) 11 (K): The self-check for Cyan failed but the others were successful.
B230/B237 5-142 SM See the troubleshooting section for details. 001 History: Latest *ENG 002 Result: Latest 1 *ENG 003 Result: Latest 2 *ENG 004 Result: Latest 3 *ENG 005 Result: Latest 4 *ENG 006 Result: Latest 5 *ENG 007 Result: Latest 6 *ENG 008 Result: Latest 7 *ENG 009 Result: Latest 8 *ENG 010 Result: Latest 9 *ENG[ 11111111 t o 99999999 / - / 1/step] 3013 [T Sensor Initial Set: Execution] Developer Initialization Setting 001 Execution: ALL - 002 Execution: COL (MCY) - 003 Execution: Bk - 004 Execution: M - 005 Execution: C - 006 Execution: Y - DFU 3014 [T Sensor Initial Set Result: Display] Developer Initialization Result: Display Display: YCMK *ENG[0 to 9999 / - / - ] 1: Success 2 to 9: Failure 001 Displays the developer initialization result. See section 4.1.1 for details on the
SM 5-143 B230/B237 Service Tables meaning of each code. All colors are displayed. Values are displayed in the order Y C M Bk. e.g., 1 (Y) 2 (C) 1 (M) 1 (Bk): Initialization of Cyan failed but the others succeeded. 3015 [Forced Toner Supply] Forced Toner Supply ([Color]) 001 Execution: ALL - 002 Execution: COL (MCY) - 003 Execution: Bk - 004 Execution: M - 005 Execution: C - 006 Execution: Y - Executes the manual toner supply to the development unit. [Forced Toner Supply: Setting] Forced Toner Supply Setting ([Color]) 3016 Specifies the manual toner supply time for each color. 001 Supply Time: Bk *ENG 002 Supply Time: M *ENG 003 Supply Time: C *ENG 004 Supply Time: Y *ENG[0 to 30 / 4 / 1 sec/step] [Vt Limit Error] 3020 DFU 001 Delta Vt Threshold *ENG [0 to 5 / 5 / 0.01 V/step] 002 Upper Threshold *ENG [0 to 5 / 4.7 / 0.01 V/step] 003 Threshold Number of Upper counter *ENG [0 to 99 / 20 / 1 time/step]
B230/B237 5-144 SM 004 Lower Threshold *ENG [0 to 5 / 0.5 / 0.01 V/step] 005 Number of Lower counter *ENG [0 to 99 / 10 / 1 time/step] 006 Upper Counter: Bk *ENG 007 Upper Counter: M *ENG 008 Upper Counter: C *ENG 009 Upper Counter: Y *ENG 010 Lower Counter: Bk *ENG 011 Lower Counter: M *ENG 012 Lower Counter: C *ENG 013 Lower Counter: Y *ENG[0 to 99 / 0/ 1 time/step] [TD Sensor Initial Set] Developer Initialization Setting 3021 Specifies the developer agitation time for each color at the developer initialization. DFU 001 Agitation Time: Bk *ENG 002 Agitation Time: M *ENG 003 Agitation Time: C *ENG 004 Agitation Time: Y *ENG[0 to 200 / 30 / 1 sec/step] 005-008 Sets the execution flag of the developer initialization for each color. DFU 005 Execution Flag: Bk *ENG 006 Execution Flag: M *ENG 007 Execution Flag: C *ENG 008 Execution Flag: Y *ENG[0 or 1 / 0 / 1/step] 0: Flag OFF, 1: Flag ON This flag is cleared after executing TD sensor initialization. 009 Prohibition *ENG Enables or disables developer initialization.