Ricoh B230 Service Manual
Have a look at the manual Ricoh B230 Service Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 127 Ricoh manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
SM 5-35 B230/B237 Service Tables 006 Maximum: Center *ENG 007 Maximum: Rear *ENG [ID Sensor Check Result] DFU 2143 Displays the minimum result values of the ID sensor check. Bk, M, C, Y: ID sensors for the process control Front, Center, Rear: ID sensors for the automatic line position adjustment 001 Minimum: Bk *ENG 002 Minimum: M *ENG 003 Minimum: C *ENG 004 Minimum: Y *ENG 005 Minimum: Front *ENG 006 Minimum: Center *ENG 007 Minimum: Rear *ENG[0 to 5 / 0 / 0.01V/step] [ID Sensor Check Result] DFU 2144 Displays the maximum result 2 values of the ID sensor check. Bk, M, C, Y: ID sensors for the process control Front, Center, Rear: ID sensors for the automatic line position adjustment 001 Maximum 2: Bk *ENG 002 Maximum 2: M *ENG 003 Maximum 2: C *ENG 004 Maximum 2: Y *ENG 005 Maximum 2: Front *ENG 006 Maximum 2: Center *ENG[0 to 5 / 0 / 0.01V/step]
B230/B237 5-36 SM 007 Maximum 2: Rear *ENG [ID Sensor Check Result] DFU 2145 Displays the minimum result 2 values of the ID sensor check. Bk, M, C, Y: ID sensors for the process control Front, Center, Rear: ID sensors for the automatic line position adjustment 001 Minimum 2: Bk *ENG 002 Minimum 2: M *ENG 003 Minimum 2: C *ENG 004 Minimum 2: Y *ENG 005 Minimum 2: Front *ENG 006 Minimum 2: Center *ENG 007 Minimum 2: Rear *ENG[0 to 5 / 0 / 0.01V/step] [Area Mag. Correction] LD Pulse Area Correction (Color, Area) FA 2150 Adjusts the magnification for each area. The main scan (297 mm) is divided into 8 areas. Area 1 is at the front side of the machine (left side of the image) and area 8 is at the rear side of the machine (right side of the image). Decreasing a value makes the image shift to the left side on the print. Increasing a value makes the image shift to the right side on the print. 1 pulse = 1/16 dot 027 Area0: Bk *ENG DFU 028 Area1: Bk *ENG 029 Area2: Bk *ENG 030 Area3: Bk *ENG 031 Area4: Bk *ENG[–256 to 255 / 0 / 1 sub-dot/step ]
SM 5-37 B230/B237 Service Tables 032 Area5: Bk *ENG 033 Area6: Bk *ENG 034 Area7: Bk *ENG 035 Area8: Bk *ENG 036 Area9: Bk *ENG 037 Area10: Bk *ENG 038 Area11: Bk *ENG 039 Area12: Bk *ENGNot used 079 Area0: M *ENG Not used 080 Area1: M *ENG 081 Area2: M *ENG 082 Area3: M *ENG 083 Area4: M *ENG 084 Area5: M *ENG 085 Area6: M *ENG 086 Area7: M *ENG 087 Area8: M *ENG[–256 to 255 / 0 / 1 sub-dot/step] 088 Area9: M *ENG 089 Area10: M *ENG 090 Area11: M *ENG 091 Area12: M *ENGNot used 131 Area0: C *ENG Not used 132 Area1: C *ENG [–256 to 255 / 0 / 1 sub-dot/step]
B230/B237 5-38 SM 133 Area2: C *ENG 134 Area3: C *ENG 135 Area4: C *ENG 136 Area5: C *ENG 137 Area6: C *ENG 138 Area7: C *ENG 139 Area8: C *ENG 140 Area9: C *ENG 141 Area10: C *ENG 142 Area11: C *ENG 143 Area12: C *ENGNot used 183 Area0: Y *ENG Not used 184 Area1: Y *ENG 185 Area2: Y *ENG 186 Area3: Y *ENG 187 Area4: Y *ENG 188 Area5: Y *ENG 189 Area6: Y *ENG 190 Area7: Y *ENG 191 Area8: Y *ENG[–256 to 255 / 0 / 1 sub-dot/step] 192 Area9: Y *ENG 193 Area10: Y *ENG 194 Area11: Y *ENGNot used
SM 5-39 B230/B237 Service Tables 195 Area12: Y *ENG [Area Shad. Correct. Setting] FA 2152 Adjusts the area correction value for each LD power. The main scan is divided into 16 areas. However, the image areas are limited from area 1 to area 14. For BK and Magenta, area 1 is at the rear side of the machine (left side of the image) and area 14 is at the front side of the machine (right side of the image). For Cyan and Yellow, area 1 is at the front side of the machine (right side of the image) and area 14 is at the rear side of the machine (left side of the image). 001 Area 0: Bk *ENGThis is for the synchronizing detection board. 002 Area 1: Bk *ENG 003 Area 2: Bk *ENG 004 Area 3: Bk *ENG 005 Area 4: Bk *ENG 006 Area 5: Bk *ENG 007 Area 6: Bk *ENG 008 Area 7: Bk *ENG 009 Area 8: Bk *ENG 010 Area 9: Bk *ENG 011 Area 10: Bk *ENG 012 Area 11: Bk *ENG 013 Area 12: Bk *ENG 014 Area 13: Bk *ENG 015 Area 14: Bk *ENG[50 to 150 / 100 / 1 %/step]
B230/B237 5-40 SM 016 Area 15: Bk *ENG This is out of the image area. 033 Area 0: M *ENGThis is for the synchronizing detection board. 034 Area 1: M *ENG 035 Area 2: M *ENG 036 Area 3: M *ENG 037 Area 4: M *ENG 038 Area 5: M *ENG 039 Area 6: M *ENG 040 Area 7: M *ENG 041 Area 8: M *ENG 042 Area 9: M *ENG 043 Area 10: M *ENG 044 Area 11: M *ENG 045 Area 12: M *ENG 046 Area 13: M *ENG 047 Area 14: M *ENG[50 to 150 / 100 / 1 %/step] 048 Area 15: M *ENG This is out of the image area. 065 Area 0: C *ENGThis is for the synchronizing detection board. 066 Area 1: C *ENG 067 Area 2: C *ENG 068 Area 3: C *ENG 069 Area 4: C *ENG[50 to 150 / 100 / 1 %/step]
SM 5-41 B230/B237 Service Tables 070 Area 5: C *ENG 071 Area 6: C *ENG 072 Area 7: C *ENG 073 Area 8: C *ENG 074 Area 9: C *ENG 075 Area 10: C *ENG 076 Area 11: C *ENG 077 Area 12: C *ENG 078 Area 13: C *ENG 079 Area 14: C *ENG 080 Area 15: C *ENG This is out of the image area. 097 Area 0: Y *ENGThis is for the synchronizing detection board. 098 Area 1: Y *ENG 099 Area 2: Y *ENG 100 Area 3: Y *ENG 101 Area 4: Y *ENG 102 Area 5: Y *ENG 103 Area 6: Y *ENG 104 Area 7: Y *ENG 105 Area 8: Y *ENG 106 Area 9: Y *ENG 107 Area 10: Y *ENG 108 Area 11: Y *ENG[50 to 150 / 100 / 1 %/step]
B230/B237 5-42 SM 109 Area 12: Y *ENG 110 Area 13: Y *ENG 111 Area 14: Y *ENG 112 Area 15: Y *ENG This is out of the image area. 2180 [Line Position Adj. Setting Clear] 001 Color Regist - DFU 002 Main Scan Length Detection - DFU 003 MUSIC Result - DFU 004 Area Magnification Correction - DFU 2181 [Line Position Adj. Result] Displays the values for each correction. ƒ Paper Int. Mag: Subdot indicates the magnification correction value between two sheets of paper. ƒ Mag.Cor. Subdot indicates the magnification correction value. ƒ M. Scan Erro. indicates the shift correction value in the main scan direction. ƒ S. Scan Erro. Indicates the shift correction value in the sub scan direction. ƒ M. Cor.: Dot indicates the dot correction value in the main scan direction. ƒ M. Cor.: Subdot indicates the sub dot correction value in the main scan direction. 001 Paper Int. Mag: Subdot: Bk *ENG [–32768 to 32767 / 0 / 1 pulse/step] 002 Mag.Cor. Subdot: Bk *ENG [–32768 to 32767 / 0 / 1 pulse/step]
SM 5-43 B230/B237 Service Tables 003 Skew: M *ENG 004 Bent: M *ENG[–5000 to 5000 / 0 / 0.001 um/step] 005 M. Scan Erro.: Left: M *ENG 006 M. Scan Erro.: Center: M *ENG 007 M. Scan Erro.: Right: M *ENG 008 S. Scan Erro.: Left: M *ENG 009 S. Scan Erro.: Center: M *ENG 010 S. Scan Erro.: Right: M *ENG[–5000 to 5000 / 0 / 0.001 um/step] 011 M. Cor.: Dot: M *ENG 012 M. Cor.: Subdot: M *ENG[–512 to 511 / 0 / 1 dot/step] 013 Paper Int. Mag: Subdot: M *ENG 014 Mag.Cor. Subdot: M *ENG 015 M. Left Mag.: Subdot: M *ENG 016 M. Right Mag.: Subdot: M *ENG[–32768 to 32767 / 0 / 1 pulse/step] 017 S. Cor.: 600 Line: M *ENG [–16384 to 16383 / 0 / 1 line/step] 018 S. Cor.: 600 Sub: M *ENG [–1 to 1 / 0 / 0.001 line/step] 019 S. Cor.: 1200 Line: M *ENG [–16384 to 16383 / 0 / 1 line/step] 020 S. Cor.: 1200 Sub: M *ENG [–1 to 1 / 0 / 0.001 line/step] 021 Skew: C *ENG 022 Bent: C *ENG[–5000 to 5000 / 0 / 0.001 um/step] 023 M. Scan Erro.: Left: C *ENG 024 M. Scan Erro.: Center: C *ENG 025 M. Scan Erro.: Right: C *ENG[–5000 to 5000 / 0 / 0.001 um/step]
B230/B237 5-44 SM 026 S. Scan Erro.: Left: C *ENG 027 S. Scan Erro.: Center: C *ENG 028 S. Scan Erro.: Right: C *ENG[–5000 to 5000 / 0 / 0.001 um/step] 029 M. Cor.: Dot: C *ENG [–512 to 511 / 0 / 1 dot/step] 030 M. Cor.: Subdot: C *ENG [–15 to 15 / 0 / 1 pulse/step] 031 Paper Int. Mag: Subdot: C *ENG 032 Mag.Cor. Subdot: C *ENG 033 M. Left Mag.: Subdot: C *ENG 034 M. Right Mag.: Subdot: C *ENG[–32768 to 32767 / 0 / 1 pulse/step] 035 S. Cor.: 600 Line: C *ENG [–16384 to 16383 / 0 / 1 line/step] 036 S. Cor.: 600 Sub: C *ENG [–1 to 1 / 0 / 0.001 line/step] 037 S. Cor.: 1200 Line: C *ENG [–16384 to 16383 / 0 / 1 line/step] 038 S. Cor.: 1200 Sub: C *ENG [–1 to 1 / 0 / 0.001 line/step] 039 Skew: Y *ENG 040 Bent: Y *ENG[–5000 to 5000 / 0 / 0.001 um/step] 041 M. Scan Erro.: Left: Y *ENG 042 M. Scan Erro.: Center: Y *ENG 043 M. Scan Erro.: Right: Y *ENG[–5000 to 5000 / 0 / 0.001 um/step] 044 S. Scan Erro.: Left: Y *ENG 045 S. Scan Erro.: Center: Y *ENG 046 S. Scan Erro.: Right: Y *ENG[–5000 to 5000 / 0 / 0.001 um/step] 047 M. Cor.: Dot: Y *ENG [–512 to 511 / 0 / 1 dot/step] 048 M. Cor.: Subdot: Y *ENG [–15 to 15 / 0 / 1 pulse/step]