Home > Ricoh > Printer > Ricoh B230 Service Manual

Ricoh B230 Service Manual

    Download as PDF Print this page Share this page

    Have a look at the manual Ricoh B230 Service Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 127 Ricoh manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    Page
    of 1286
    							Dedicated Transmission Parameters 
    S M  111 B 7 86  
    B786 
    Fax Option 
     
    Switch 06 - Not used (do not change the settings) 
    Switch 07 - Not used (do not change the settings) 
    Switch 08 - Not used (do not change the settings) 
    Switch 09 - Not used (do not change the settings) 
      
    						
    							Service RAM Addresses 
    B786 112  SM 
    4.6 SERVICE RAM ADDRESSES 
     
    ƒ  Do not change the settings which are marked as “Not used” or “Read only.” 
    680001 to 680004(H) - ROM version (Read only) 
    680001(H) - Revision number (BCD) 
    680002(H) - Year (BCD) 
    680003(H) - Month (BCD) 
    680004(H) - Day (BCD) 
    680006 to 680015(H) - Machine’s serial number (16 digits - ASCII) 
    680018(H) - Total program checksum (low) 
    680019(H) - Total program checksum (high) 
    680020 to 68003F(H) - System bit switches 
    680050 to 68005F(H) - Printer bit switches 
    680060 to 68007F(H) - Communication bit switches 
    680080 to 68008F(H) - G3 bit switches 
    680090 to 68009F(H) - G3-2 bit switches: Not used 
    6800A0 to 6800AF(H) - G3-3 bit switches: Not used 
    6800D0(H) - User parameter switch 00 (SWUER_00) : Not used 
    6800D1(H) - User parameter switch 01 (SWUSR_01) : Not used 
    6800D2(H) - User parameter switch 02 (SWUSR_02) 
    Bit 0: Forwarding mark printing on forwarded messages  0: Disabled, 1: Enabled 
    Bit 1: Center mark printing on received copies 
    (This switch is not printed on the user parameter list.) 
    0: Disabled, 1: Enabled 
    Bit 2: Reception time printing 
    (This switch is not printed on the user parameter list.) 
    0: Disabled, 1: Enabled 
    Bit 3: TSI print on received messages 0: Disabled, 1: Enabled 
    Bit 4: Checkered mark printing 
    (This switch is not printed on the user parameter list.) 
    0: Disabled, 1: Enabled 
    Bit 5: Not used 
    Bit 6: Not used 
    Bit 7: Not used 
    6800D3(H) - User parameter switch 03 (SWUSR_03: Automatic report printout)  
    						
    							Service RAM Addresses 
    SM 113 B786 
    B786 
    Fax Option 
    Bit 0: Transmission result report (memory transmissions) 0: Off, 1: On 
    Bit 1: Not used 
    Bit 2: Memory storage report 0: Off, 1: On 
    Bit 3: Polling reserve report (polling reception) 0: Off, 1: On 
    Bit 4: Polling result report (polling reception) 0: Off, 1: On 
    Bit 5: Transmission result report (immediate transmissions) 0: Off, 1: On 
    Bit 6: Not used 
    Bit 7: Journal 0: Off, 1: On 
    6800D4(H) - User parameter switch 04 (SWUSR_04: Automatic report printout) 
    Bit 0: Not used 
    Bit 1: Automatic communication failure report and transfer result report output 0: Off, 1: On  
    Bits 2 to 3: Not used 
    Bit 4: Indicates the parties 0: Not indicated, 1: Indicated 
    Bit 5: Include sender’s name on reports 0: Off, 1: On 
    Bit 6: Not used 
    Bit 7: Inclusion of a sample image on reports  0: Off, 1: On 
    6800D5(H) - User parameter switch 05 (SWUSR_05) 
    Bit 0: Substitute reception when the base copier is in an SC condition 
    0: Enabled, 1: Disabled 
    Bits 1 and 2: Condition for substitute rx when the machine cannot print messages (Paper 
    end, toner end, jam, and during night mode) 
    Bit 2: 0, Bit 1: 0 = The machine receives all the fax messages. 
    Bit 2: 0, Bit 1: 1 = The machine receives the fax messages with RTI or CSI. 
    Bit 2: 1, Bit 1: 0 = The machine receives the fax messages with the same ID code. 
    Bit 2: 1, Bit 1: 1 =  The machine does not receive anything. 
    Bit 3: Not used 
    Bit 4: Not used 
    Bit 5: Just size printing 0: Off, 1: On 
    Bit 6: Not used 
    Bit 7: Add paper display when a cassette is empty  0: Off, 1: On 
    6800D6(H) - User parameter switch 06 (SWUSR_06): Not used 
    6800D7(H) - User parameter switch 07 (SWUSR_07) 
    Bit 0 Ringing 0: Off, 1: On 
    Bit1: Automatic answering message 0: Off, 1: On 
    Bit 2: Parallel memory transmission 0: Off, 1: On 
    Bits 3 and 4: Not used  
    						
    							Service RAM Addresses 
    B786 114  SM 
    Bit 5: Remote control 0: Off, 1: On 
    Bits 6 and 7: Not used 
    6800D8(H) - User parameter switch 08 (SWUSR_08) 
    Bits 0 and 1: Not used. 
    Bit 2: Authorized reception  
    0: Only faxes from senders whose RTIs/CSIs are specified for this feature are accepted. 
    1: Only faxes from senders whose RTIs/CSIs are not specified for this feature are 
    accepted. 
    Bits 3 to 7: Not used. 
    6800D9(H) - User parameter switch 09 (SWUSR_09): Not used 
    6800DA(H) - User parameter switch 10 (SWUSR_0A) 
    Bits 0 to 2: Not used 
    Bit 3: Page reduction 0: Off, 1: On 
    Bits 4 and 5: Not used 
    Bit 6: Use both e-mail notification and printed reports to confirm the transmission results 0: 
    Off, 1: On 
    Bit 7: Not used 
    6800DB(H) - User parameter switch 11 (SWUSR_0B) 
    Bits 0 and 1: Not used 
    Bit 2: White original detection 0: Off, 1: On (alarm and alert message on the LCD) 
    Bit 3: Receive rejection for 1300 Hz transmission 0: Off (receive), 1: On (not receive) 
    Bit 5: Not used 
    Bit 6: Printout of messages received while acting as a forwarding station 0: Off, 1: On 
    Bit 7: Not used 
    6800DC(H) - User parameter switch 12 (SWUSR_0C): Not used 
    6800DD(H) - User parameter switch 13 (SWUSR_0D): Not used 
    6800DE(H) - User parameter switch 14 (SWUSR_0E) 
    Bit 0: Message printout while the machine is in Night Printing mode 0: On, 1: Off 
    Bit 1: Maximum document length detection 0: Double letter, 1: Longer than double-letter 
    (well log) – up to 1,200 mm  
    Bit 2: Not used 
    Bit 3: Fax mode settings, such as resolution, before a mode key 
    (Copy/Fax/Printer/Scanner) is pressed 0: Not cleared, 1: Cleared 
    Bits 4 to 6: Not used 
    Bit 7: Not used 
    6800DF(H) - User parameter switch 15 (SWUSR_0F)  
    						
    							Service RAM Addresses 
    SM 115 B786 
    B786 
    Fax Option 
    (This switch is not printed on the user parameter list.) 
    Bits 0, 1 and 2: Cassette for fax printout 
    Bit 2: 0, Bit 1: 0, Bit 0: 1 = 1st paper feed station 
    Bit 2: 0, Bit 1: 1, Bit 0: 0 = 2nd paper feed station 
    Bit 2: 0, Bit 1: 1, Bit 0: 1 = 3rd paper feed station 
    Bit 2: 1, Bit 1: 0, Bit 0: 0 = 4th paper feed station 
    Bit 2: 1, Bit 1: 0, Bit 0: 1 = LCT 
    Other settings Not used 
    Bits 3 and 4: Not used 
    Bit 5: Using the cassette specified by bits 0, 1 and 2 above only 0: On, 1: Off 
    Bits 6 and 7: Not used 
    6800E0(H) – User parameter switch 16 (SWUSR_10) 
    (This switch is not printed on the user parameter list.) 
    Bits 0 and 1: Not used 
    Bit 2: Paper size selection priority for an A4 size fax message when A4/LT size paper is 
    not available. 0: A3 has priority, 1: B4 has priority 
    Bits 3 to 7: Not used 
    6800E1(H) – User parameter switch 17 (SWUSR_11) 
    Bit 0: Not used 
    Bit 1: Not used 
    Bit 2: Inclusion of the “Add” button when a sequence of Quick/Speed dials is selected for 
    broadcasting 0:Not needed, 1: Needed 
    Bits 3 to 6: Not used 
    Bit 7: Press “Start” key without an original when using the on hook dial or the external 
    telephone,  
    0: displays “Cannot detect original size”. 1: Receives fax messages. 
    6800E2(H) - User parameter switch 18 (SWUSR_12) 
    Bit 0: TTI date 0: Off, 1: On 
    Bit 1: TTI sender          0: Off, 1: On 
    Bit 2: TTI file number      0: Off, 1: On 
    Bit 3: TTI page number    0: Off, 1: On 
    Bits 4 to 6: Not used 
    Bit 7: Japan only 
    6800E3(H) - User parameter switch 19 (SWUSR_13) 
    Bit 0: Not used 
    Bit 1: Journal format  
    						
    							Service RAM Addresses 
    B786 116  SM 
    0: The Journal is separated into transmissions and receptions 
    1: The Journal is separated into G3-1, G3-2, and G3-3 communications 
    Bit 2: Not used 
    Bit 3: 90° image rotation during B5 portrait Tx (This switch is not printed on the user 
    parameter list.) 0: Off, 1: On 
    Bit 4: Reduction of sample images on reports to 50% in the main scan and sub-scan 
    directions. (This switch is not printed on the user parameter list.) 0: Technician adjustment 
    (printer switch 0E bits 3 and 4), 1: 50% reduction 
    Bit 5: Use of A5 size paper for reports (This switch is not printed on the user parameter 
    list.) 0: Off, 1: On 
    Bits 6 and 7: Not used 
    6800E4(H) - User parameter switch 20 (SWUSR_14) 
    Bit 0: Automatic printing of the LAN fax result report 0: Off, 1: On 
    Bit 1: Not used.  
    Bits 2 to 5: Store documents in memory which could not be printed from PC fax (LAN fax) 
    driver  
    Bit 5  Bit 4  Bit 3  Bit 2  Setting 
    0 0 0 0 0 min. 
    0 0 0 1 1 min. 
         
    1 1 1 0 14 min. 
    1 1 1 1 15 min. 
    Bits 6 and 7: Not used. 
    6800E5(H) - User parameter switch 21 (SWUSR_15) 
    Bit 0: Print results of sending reception notice request message 0: Disabled (print only 
    when error occurs), 1: Enabled 
    Bit 1: Respond to e-mail reception acknowledgment request 0: Disabled, 1: Enabled 
    Bit 2: Not used 
    Bit 3: File format for forwarded folders 0: TIFF, 1:PDF 
    Bit 4: Transmit Journal by E-mail 0: Disabled, 1: Enabled 
    Bit 5: Not used 
    Bit 6: Network error display 0: Displayed, 1: Not displayed 
    Bit 7: Transmit error mail notification 0: Enabled, 1: Disabled 
    6800E6(H)  - User parameter switch 22 (SWUSR_16) 
    (This switch is not printed on the user parameter list.)  
    						
    							Service RAM Addresses 
    SM 117 B786 
    B786 
    Fax Option 
    Bit 0: Dial tone detection (PSTN 1) 0: Disabled, 1: Enabled 
    Bits 1 to 7: Not used 
    6800E7(H) – User parameter switch 23 (SWUSR_17): Not used 
    6800E8(H) - User parameter switch 24 (SWUSR_18): Not used 
    6800E9(H) - User parameter switch 25 (SWUSR_19) 
    Bit 0: Not used 
    Bit 1: Reception mode switch timer 0: Off, 1: On (switching Fax or Fax/Tel) 
    Bit 2: Mode priority switch 0: Fax first, 1: Tel first 
    Bit 3: Dial in function (Japan Only) 
    Bit 4: RDS operation 0: Not acceptable, 1: Acceptable for the limit specified by system 
    switch 03 
     
    ƒ  This bit is only effective when RDS operation can be selected by the user  
    (see system switch 02). 
    Bits 5 to 7: Not used 
    6800EA(H) and 6800EB(H) - User parameter switches 26 and 27 (SWUSR_1A and 
    1B): Not used 
    6800EC(H) - User parameter switch 28(SWUSR_1C) 
    Xxxxx 
    6800ED(H) - User parameter switch 29(SWUSR_1D) 
    xxxxxx 
    6800EE(H) and 6800EF(H) - User parameter switches 30 and 31 (SWUSR_1E and 1F): 
    Not used 
    6800F0(H) - User parameter switch 32 (SWUSR_20) 
    Bit 0: Quotation priority for a destination when there is no destination of the specified type 
    0: Paper output priority = Priority order: 1. IP-fax destination, 2. Fax Number, 3. E-mail 
    address, 4. Folder 
    1: Electric putout order = Priority order: 1. E-mail address, 2. Folder, 3. IP-fax destination, 
    4. Fax number 
    Bits 1 to 7: Not used 
    6800F1(H) - User parameter switch 33 (SWUSR_21): Not used 
    6800F2(H) - User parameter switch 34 (SWUSR_22) 
    Bit 0: Gatekeeper server used with IP-Fax 0: Disabled, 1: Enabled  
    Bit 1: SIP server used with IP-Fax 0: Disabled, 1: Enabled 
    Bits 2 to 7: Not used 
    680100 to 68010F(H) - G4 Parameter Switches – Not used  
    						
    							Service RAM Addresses 
    B786 118  SM 
    680110 to 68012F(H) - G4 Internal Switches – Not used 
    680130 to 68016F(H) - Service Switches 
    680170 to 68017F(H) - IFAX Switches 
    680180 to 68018F(H) - IP-FAX Switches 
    680190 to 6801AF(H) - Service station’s fax number (SP3-101) 
    6801B0 to 6801B9(H) - Own fax PABX extension number 
    6801BA to 6801C3(H) - Own fax number (PSTN) – Not used 
    6801C4 to 6801D7(H) - Own fax number (ISDN G4) – Not used 
    6801D8 to 6801E3(H) - The first subscriber number (ISDN G3) – Not used 
    6801E4 to 6801EF(H) - The second subscriber number (ISDN G3) – Not used 
    6801F0 to 6801FB(H) - The first subscriber number (ISDN G4) – Not used 
    6801FC to 680207(H) - The second subscriber number (ISDN G4) – Not used 
    680208 to 68021B(H) - PSTN-1 RTI (Max. 20 characters - ASCII) - See the following note. 
    68021C to 68022F(H) - PSTN-2 RTI (Max. 20 characters - ASCII) - Not used 
    680230 to 680246(H) - PSTN-3 RTI (Max. 20 characters - ASCII) - Not used 
    680247 to 680286(H) - TTI 1 (Max. 64 characters - ASCII) - See the following note. 
    680287 to 6802C6(H) - TTI 2 (Max. 64 characters - ASCII) - Not used 
    6802C7 to 680306(H) - TTI 3 (Max. 64 characters - ASCII) - Not used 
    680307 to 68031A(H) - PSTN-1 CSI (Max. 20 characters - ASCII) 
    68031B to 68032E(H) - PSTN-2 CSI (Max.20 characters - ASCII) - Not used 
    68032F to 680342(H) - PSTN-3 CSI (Max.20 characters - ASCII) - Not used 
    680343(H) - Number of PSTN-1 CSI characters (Hex) 
    680344(H) - Number of PSTN-2 CSI characters (Hex) - Not used 
    680345(H) Number of PSTN-3 CSI characters (Hex) - Not used 
     
    ƒ  If the number of characters is less than the maximum (20 for RTI, 64 for TTI), add 
    a stop code (00[H]) after the last character. 
    680380 to 680387(H) - Last power off time (Read only) 
    680380(H) - 01(H) - 24-hour clock, 00(H) - 12-hour clock (AM), 02(H) - 12-hour clock (PM) 
    680381(H) - Year (BCD) 
    680382(H) - Month (BCD) 
    680383(H) - Day (BCD) 
    680384(H) – Hour 
    680385(H) – Minute 
    680386(H) – Second 
    680387(H) - 00: Monday, 01: Tuesday, 02: Wednesday, /// , 06: Sunday  
    						
    							Service RAM Addresses 
    SM 119 B786 
    B786 
    Fax Option 
    680394(H) - Optional equipment (Read only – Do not change the settings) 
    Bit 0: Page Memory    0: Not installed, 1: Installed 
    Bit 1: SAF Memory     0: Not installed, 1: Installed 
    Bits 2 to 7; Not used 
    680395(H) - Optional equipment (Read only – Do not change the settings) 
    Bits 0 to 3: Not used  
    Bit 4: G3-2 0: Not installed, 1: Installed 
    Bit 5: G3-3 0: Not installed, 1: Installed 
    Bit 6 and 7: Not used 
    680406 to 68040A – Option G3 board (G3-2) ROM information (Read only) 
    680406(H) - Suffix (BCD) 
    680407(H) - Version (BCD) 
    680408(H) - Year (BCD) 
    680409(H) - Month (BCD) 
    68040A(H) - Day (BCD) 
    68040B to 68040F – Option G3 board (G3-3) ROM information (Read only) 
    68040B(H) - Suffix (BCD) 
    68040C(H) - Version (BCD) 
    68040D(H) - Year (BCD) 
    68040E(H) - Month (BCD) 
    68040F(H) - Day (BCD) 
    680410(H) - G3-1 Modem ROM version (Read only) 
    680412(H) - G3-2 Modem ROM version (Read only) 
    680414(H) - G3-3 Modem ROM version (Read only) 
    680420(H) - Number of multiple sets print (Read only) 
    680476(H) - Time for economy transmission (hour in 24h clock format - BCD) 
    680477(H) - Time for economy transmission (minute - BCD)  
    680492(H) - Transmission monitor volume 00 - 07(H) 
    680493(H) - Reception monitor volume  00 - 07(H) 
    680494(H) - On-hook monitor volume  00 - 07(H) 
    680495(H) - Dialing monitor volume  00 - 07(H) 
    680496(H) - Buzzer volume   00 - 07(H) 
    680497(H) - Beeper volume    00 - 07(H) 
    6804A8(H) - Machine code (Check ram 4)   
    688E8E to 68918D(H) - SIP server address (Read only) 
    688E8E(H) - Proxy server - Main (Max. 128 characters - ASCII)  
    						
    							Service RAM Addresses 
    B786 120  SM 
    688F0E(H) - Proxy server - Sub (Max. 128 characters - ASCII) 
    688F8E(H) - Redirect server - Main (Max. 128 characters - ASCII) 
    68900E(H) - Redirect server - Sub (Max. 128 characters - ASCII) 
    68908E(H) - Registrar server - Main (Max. 128 characters - ASCII) 
    68910E(H) - Registrar server - Sub (Max. 128 characters - ASCII) 
    68918E(H) - Gatekeeper server address - Main (Max. 128 characters - ASCII) 
    68920E(H) - Gatekeeper server address - Sub (Max. 128 characters - ASCII) 
    68928E(H) - Arias Number (Max. 128 characters - ASCII) 
    68930E(H) - SIP user name (Max. 128 characters - ASCII) 
    68938E(H) - SIP digest authentication password (Max. 128 characters - ASCII) 
    68940E(H) - Gateway address information (Max. 7100 characters - ASCII) 
    68AFCA(H) - Stand-by port number for H.232 connection 
    68AFCCH) - Stand-by port number for SIP connection 
    68AFCE(H) - RAS port number 
    68AFD0(H) - Gatekeeper port number 
    68AFD2(H) - Port number of data waiting for T.38 
    68AFD4(H) - Port number of SIP server 
    68AFD6(H) - Priority for SIP and H.323  0: H.323, 1: SIP 
    68AFD7(H) - SIP function  0: Disabled, 1: Enabled 
    68AFD8(H) - H.323 function  0: Disabled, 1: Enabled 
    68AFD9(H) - SIP digest authentication function 0: Disabled, 1: Enabled 
    68AFDA(H) - IP-Fax backup data 00 - 600 (H) 
    69ECBE(H) - 69ECDE(H) - Dial tone detection parameter (Max. 11 x 3 lines) 
    This initializes following order. [0x04, 0x40, 0x03, 0x60, 0x64, 0xf4, 0x01,0x64, 0x04, 0xc8, 
    0x00] 
    6BEBFE(H) – Dial tone detection frequency – Upper limit (High) 
    Defaults: NA: 06, EU: 06, ASIA: 06 
    6BEBFF(H) – Dial tone detection frequency – Upper Limit (Low) 
    Defaults: NA: 50, EU: 50, ASIA: 50 
    6BEC00(H) – Dial tone detection frequency – Lower Limit (High) 
    Defaults: NA: 03, EU: 02, ASIA: 02 
    6BEC01(H) – Dial tone detection frequency – Lower Limit (Low) 
    Defaults: NA: 60, EU: 90, ASIA: 90 
    6BEC02(H) –Dial tone detection waiting time (20 ms) 
    Defaults: NA: 64, EU 64, ASIA: 64 
    6BEC03 to 6BEC04 – Dial tone detection monitoring time (20 ms)  
    						
    All Ricoh manuals Comments (0)

    Related Manuals for Ricoh B230 Service Manual