    5610 [ACC Factory Setting] 
    Recall - - 
    004 
    Recalls the factory settings. 
    Overwrite - - 
    005 
    Overwrites the current values onto the factory settings. 
    Previous Setting  -  - 
    006 
    Recalls the previous settings. 
     
    5611 [Toner Color in 2C] 
    B-C *ENG[0 to 128 / 100 / 1 /step] 
    128: Darkest density 
    001 
    Adjusts the Cyan correction value of the blue signal in two-color mode. 
    B-M *ENG[0 to 128 / 100 / 1 /step] 
    128: Darkest density 
    002 
    Adjusts the Magenta correction value of the blue signal in two-color mode. 
    G-C *ENG[0 to 128 / 100 / 1 /step] 
    128: Darkest density 
    003 
    Adjusts the Cyan correction value of the blue signal in two-color mode. 
    G-Y *ENG[0 to 128 / 100 / 1 /step] 
    128: Darkest density 
    004 
    Adjusts the Yellow correction value of the blue signal in two-color mode. 
    R-M *ENG[0 to 128 / 100 / 1 /step] 
    128: Darkest density 
    005 
    Adjusts the Magenta correction value of the blue signal in two-color mode. 
    006 
    R-Y *ENG
    [0 to 128 / 100 / 1 /step]  
    						
    							 
    B230/B237 5-236  SM 
    128: Darkest density 
    Adjusts the Yellow correction value of the blue signal in two-color mode. 
     
    5618 [Color Mode Display Selection] 
    - *CTL[0 or 1 / 1 / - ] 
    0: ACS, Colour, Black & White, Two Colour, 
    Single colour 
    1: ACD, Full Colour, Black & White   
    001 
    Selects the color selection display on the LCD. 
     
    5801 [Memory Clear] 
    NOTE: For more information, see “NOTE 1” following SP8-xxx table. 
    001 All Clear 
     Resets all correction data for process control and all software counters, and 
    returns all modes and adjustments to their default values. 
    Use this SP only after replacing the NVRAM, or after the copier has 
    malfunctioned due to a damaged NVRAM. 
    002 Engine  -  - 
      Clears the engine settings. 
    003 SCS  -  - 
      Clears the system settings. 
    IMH Memory Clr  -  - 
    004 
    Clears IMH data. DFU 
    MCS - - 
    005 
    Clears MCS data. DFU 
    006 Copier Application  -  -  
    						
    							 
    SM 5-237 B230/B237 
    Service 
    Tables 
    Clears the copy application settings. 
    Fax Application  -  - 
    007 
    Clears the fax application settings. 
    Printer Application  -  - 
    008 
    Clears the printer application settings. 
    Scanner Application  -     - 
    009 
    Clears the scanner application settings. 
    Web Service/Network 
    Application -   - 
    010 
    Delete the netfile application management files and thumbnails, and 
    initializes the job login ID. 
    NCS - - 
    011 Initializes the system default and interface settings (IP address also), 
    SmartDeviceMonitor for 
    Admin, WebStatusMonitor settings, and the TELNET settings.   
    R-FAX - - 
    012 
    Initializes the job login ID, SmartDeviceMonitor for 
    Admin, job history, and local storage file numbers.   
    Clear DCS Settings  -  - 
    014 
    Initializes the DCS (Delivery Control Service) settings. 
    Clear UCS Settings  -  - 
    015 
    Initializes the UCS (User Information Control Service) settings. 
    MIRS Setting  -  - 
    016 
    Initializes the MIRS (Machine Information Report Service) settings. 
    017 CCS  -  -  
    						
    							 
    B230/B237 5-238  SM 
    Initializes the CCS (Certification and Charge-control Service) settings. 
    SRM Memory Clr  -  - 
    018 
    Initializes the SRM (System Resource Manager) settings. 
    LCS - - 
    019 
    Initializes the LCS (Log Count Service) settings. 
    WebUapl  - 
    020 
    Initializes the WebUapl settings. 
     
    [Free Run] 
    5802 Performs a free run on the copier engine. 
     
    ƒ  The machine starts free run in the same condition as the sequence 
    of A4/LT, A3 or A4 SEF printing from the 1st or 2nd tray. Therefore, 
    the correct paper should be loaded in the 1st tray or 2nd tray, but 
    paper is not fed. 
    ƒ  The main switch has to be turned off and on after using the free run 
    mode for a test. 
    001 TRAY1: A4LEF: FC  - 
    002 TRAY2: A3: FC  - 
    003 TRAY2: A4SEF: FC  - - 
     
    5803 [Input Check] -  See Input Check in this section. 
    5804 [Output Check] - See Output Check in this section. 
     
     
    [SC Reset] 
    5810 
    Resets a type A service call condition.  
    						
    							 
    SM 5-239 B230/B237 
    Service 
    Tables 
    NOTE: Turn the main switch off and on after resetting the SC code. 
    001  Fusing SC Reset  -  - 
     
    5811 [Machine Serial] Machine Serial Number Display 
    002  Display  *ENG Displays the machine serial number. 
     
    5812 [Service Tel. No. Setting] 
    Service *CTL - 
    001 Sets the telephone number for a service representative. This number is 
    printed on the Counter List, which can be printed with the user’s “Counter” 
    menu. 
    This can be up to 20 characters (both numbers and alphabetic characters can 
    be input). 
    Facsimile *CTL - 
    002 Sets the fax or telephone number for a service representative. This number is 
    printed on the Counter List. 
    This can be up to 20 characters (both numbers and alphabetic characters can 
    be input). 
    Supply *CTL - 
    003 
    Use this to input the telephone number of your supplier for consumables. 
    Enter the number and press #. 
    Operation *CTL - 
    004 
    Use this to input the telephone number of your sales agency. Enter the 
    number and press #. 
      
    						
    							 
    B230/B237 5-240  SM 
    5816 [Remote Service] *CTL
    - 
    I/F Setting 
    001 Selects the remote service setting. 
    [0 to 2 / 2 / 1 /step] 
    0: Remote service off 
    1: CSS remote service on 
    2: NRS remote service on 
    CE Call 
    002 Performs the CE Call at the start or end of the service. 
    [0 or 1 / 0 / 1 /step] 
    0: Start of the service 
    1: End of the service 
    ƒ  This SP is activated only when SP 5816-001 is set to “2”. 
    Function Flag 
    003 Enables or disables the remote service function. 
    [0 to 1 / 0 / 1 /step] 
    0: Disabled 
    1: Enabled 
    Device Information Call Display Setting 
    006 Displays or does not display the device information call content. 
    [0 to 1 / 0 / 1 /step] 
    0: Not displayed 
    1: Displayed 
    SSL Disable 
    007 Uses or does not use the RCG certification by SSL when calling the RCG. 
    [0 to 1 / 0 / 1 /step] 
    0: Uses the RCG certification 
    1: Does no use the RCG certification 
    008 RCG Connect Timeout  
    						
    							 
    SM 5-241 B230/B237 
    Service 
    Tables 
    Specifies the connect timeout interval when calling the RCG. 
    [1 to 90 / 10 / 1 second /step] 
    RCG Write Timeout 
    009 
    Specifies the write timeout interval when calling the RCG. 
    [1 to 100 / 60 / 1 second /step] 
    RCG Read Timeout 
    010 
    Specifies the read timeout interval when calling the RCG. 
    [1 to 100 / 60 / 1 second /step] 
    Port 80 Enable  - 
    011 Enables/disables access via port 80 to the SOAP method. 
    [0 or 1 / 0 / – ] 
    0: Disabled 
    1: Enabled 
    RCG – C Registed 
    021 This SP displays the Cumin installation end flag. 
    0: Installation not completed 
    1: Installation completed 
    RCG – C Registed Detail 
    022 This SP displays the Cumin installation status. 
    0: Basil not registered 
    1: Basil registered 
    2: Device registered 
    Connect Type (N/M) 
    023 This SP displays and selects the Cumin connection method. 
    [0 or 1 / 0 / 1 /step 
    0: Internet connection 
    1: Dial-up connection 
    061 
    Cert. Expire Timing DFUProximity of the expiration of the certification.  
    						
    							 
    B230/B237 5-242  SM 
    062 Use Proxy This SP setting determines if the proxy server is 
    used when the machine communicates with the 
    service center. 
    Proxy Host 
    063 This SP sets the address of the proxy server used for communication 
    between Cumin-N and the gateway. Use this SP to set up or display the 
    customer proxy server address. The address is necessary to set up Cumin-N. 
    ƒ  The address display is limited to 128 characters. Characters beyond 
    the 128 character are ignored.   
    ƒ  This address is customer information and is not printed in the SMC 
    report. 
    Proxy Port Number 
    064 This SP sets the port number of the proxy server used for communication 
    between Cumin-N and the gateway. This setting is necessary to set up 
    Cumin-N. 
     
    ƒ  This port number is customer information and is not printed in the 
    SMC report. 
    Proxy User Name 
    065 This SP sets the HTTP proxy certification user name.  
    ƒ  The length of the name is limited to 31 characters. Any character 
    beyond the 31st character is ignored. 
    ƒ  This name is customer information and is not printed in the SMC 
    report. 
    Proxy Password 
    066 This SP sets the HTTP proxy certification password.  
    ƒ  The length of the password is limited to 31 characters. Any character 
    beyond the 31st character is ignored.  
    						
    							 
    SM 5-243 B230/B237 
    Service 
    Tables 
    ƒ  This name is customer information and is not printed in the SMC 
    report. 
    CERT: Up State 
    Displays the status of the certification update. 
    0  The certification used by Cumin is set correctly. 
    1 The certification request (setAuthKey) for update has been received 
    from the GW URL and certification is presently being updated. 
    2 The certification update is completed and the GW URL is being notified 
    of the successful update. 
    3 The certification update failed, and the GW URL is being notified of the 
    failed update. 
    4 The period of the certification has expired and new request for an 
    update is being sent to the GW URL. 
    11  A rescue update for certification has been issued and a rescue 
    certification setting is in progress for the rescue GW connection. 
    12 The rescue certification setting is completed and the GW URL is being 
    notified of the certification update request. 
    13 The notification of the request for certification update has completed 
    successfully, and the system is waiting for the certification update 
    request from the rescue GW URL. 
    14 The notification of the certification request has been received from the 
    rescue GW controller, and the certification is being stored. 
    15 The certification has been stored, and the GW URL is being notified of 
    the successful completion of this event. 
    16 The storing of the certification has failed, and the GW URL is being 
    notified of the failure of this event. 
    067 
    17  The certification update request has been received from the GW URL, 
    the GW URL was notified of the results of the update after it was  
    						
    							 
    B230/B237 5-244  SM 
    completed, but an certification error has been received, and the rescue 
    certification is being recorded. 
    18 The rescue certification of No. 17 has been recorded, and the GW URL 
    is being notified of the failure of the certification update. 
    CERT: Error 
    Displays a number code that describes the reason for the request for update 
    of the certification. 
    0  Normal. There is no request for certification update in progress. 
    1 Request for certification update in progress. The current certification 
    has expired. 
    2 An SSL error notification has been issued. Issued after the certification 
    has expired. 
    3 Notification of shift from a common authentication to an individual 
    certification. 
    4  Notification of a common certification without ID2. 
    5  Notification that no certification was issued. 
    068 
    6  Notification that GW URL does not exist. 
    069  CERT: Up ID  The ID of the request for certification. 
    083  Firmware Up Status  Displays the status of the firmware update. 
    084  Non-HDD Firm Up This setting determines if the firmware can be 
    updated, even without the HDD installed. 
    0: Not allowed update 
    1: Allowed  update 
    085  Firm Up User Check This SP setting determines if the operator can 
    confirm the previous version of the firmware before 
    the firmware update execution. If the option to 
    confirm the previous version is selected, a 
    notification is sent to the system manager and the  
    						