SM 5-235 B230/B237 Service Tables 5610 [ACC Factory Setting] Recall - - 004 Recalls the factory settings. Overwrite - - 005 Overwrites the current values onto the factory settings. Previous Setting - - 006 Recalls the previous settings. 5611 [Toner Color in 2C] B-C *ENG[0 to 128 / 100 / 1 /step] 128: Darkest density 001 Adjusts the Cyan correction value of the blue signal in two-color mode. B-M *ENG[0 to 128 / 100 / 1 /step] 128: Darkest density 002 Adjusts the Magenta correction value of the blue signal in two-color mode. G-C *ENG[0 to 128 / 100 / 1 /step] 128: Darkest density 003 Adjusts the Cyan correction value of the blue signal in two-color mode. G-Y *ENG[0 to 128 / 100 / 1 /step] 128: Darkest density 004 Adjusts the Yellow correction value of the blue signal in two-color mode. R-M *ENG[0 to 128 / 100 / 1 /step] 128: Darkest density 005 Adjusts the Magenta correction value of the blue signal in two-color mode. 006 R-Y *ENG [0 to 128 / 100 / 1 /step]
B230/B237 5-236 SM 128: Darkest density Adjusts the Yellow correction value of the blue signal in two-color mode. 5618 [Color Mode Display Selection] - *CTL[0 or 1 / 1 / - ] 0: ACS, Colour, Black & White, Two Colour, Single colour 1: ACD, Full Colour, Black & White 001 Selects the color selection display on the LCD. 5801 [Memory Clear] NOTE: For more information, see “NOTE 1” following SP8-xxx table. 001 All Clear Resets all correction data for process control and all software counters, and returns all modes and adjustments to their default values. Use this SP only after replacing the NVRAM, or after the copier has malfunctioned due to a damaged NVRAM. 002 Engine - - Clears the engine settings. 003 SCS - - Clears the system settings. IMH Memory Clr - - 004 Clears IMH data. DFU MCS - - 005 Clears MCS data. DFU 006 Copier Application - -
SM 5-237 B230/B237 Service Tables Clears the copy application settings. Fax Application - - 007 Clears the fax application settings. Printer Application - - 008 Clears the printer application settings. Scanner Application - - 009 Clears the scanner application settings. Web Service/Network Application - - 010 Delete the netfile application management files and thumbnails, and initializes the job login ID. NCS - - 011 Initializes the system default and interface settings (IP address also), SmartDeviceMonitor for Admin, WebStatusMonitor settings, and the TELNET settings. R-FAX - - 012 Initializes the job login ID, SmartDeviceMonitor for Admin, job history, and local storage file numbers. Clear DCS Settings - - 014 Initializes the DCS (Delivery Control Service) settings. Clear UCS Settings - - 015 Initializes the UCS (User Information Control Service) settings. MIRS Setting - - 016 Initializes the MIRS (Machine Information Report Service) settings. 017 CCS - -
B230/B237 5-238 SM Initializes the CCS (Certification and Charge-control Service) settings. SRM Memory Clr - - 018 Initializes the SRM (System Resource Manager) settings. LCS - - 019 Initializes the LCS (Log Count Service) settings. WebUapl - 020 Initializes the WebUapl settings. [Free Run] 5802 Performs a free run on the copier engine. ƒ The machine starts free run in the same condition as the sequence of A4/LT, A3 or A4 SEF printing from the 1st or 2nd tray. Therefore, the correct paper should be loaded in the 1st tray or 2nd tray, but paper is not fed. ƒ The main switch has to be turned off and on after using the free run mode for a test. 001 TRAY1: A4LEF: FC - 002 TRAY2: A3: FC - 003 TRAY2: A4SEF: FC - - 5803 [Input Check] - See Input Check in this section. 5804 [Output Check] - See Output Check in this section. [SC Reset] 5810 Resets a type A service call condition.
SM 5-239 B230/B237 Service Tables NOTE: Turn the main switch off and on after resetting the SC code. 001 Fusing SC Reset - - 5811 [Machine Serial] Machine Serial Number Display 002 Display *ENG Displays the machine serial number. 5812 [Service Tel. No. Setting] Service *CTL - 001 Sets the telephone number for a service representative. This number is printed on the Counter List, which can be printed with the user’s “Counter” menu. This can be up to 20 characters (both numbers and alphabetic characters can be input). Facsimile *CTL - 002 Sets the fax or telephone number for a service representative. This number is printed on the Counter List. This can be up to 20 characters (both numbers and alphabetic characters can be input). Supply *CTL - 003 Use this to input the telephone number of your supplier for consumables. Enter the number and press #. Operation *CTL - 004 Use this to input the telephone number of your sales agency. Enter the number and press #.
B230/B237 5-240 SM 5816 [Remote Service] *CTL - I/F Setting 001 Selects the remote service setting. [0 to 2 / 2 / 1 /step] 0: Remote service off 1: CSS remote service on 2: NRS remote service on CE Call 002 Performs the CE Call at the start or end of the service. [0 or 1 / 0 / 1 /step] 0: Start of the service 1: End of the service ƒ This SP is activated only when SP 5816-001 is set to “2”. Function Flag 003 Enables or disables the remote service function. [0 to 1 / 0 / 1 /step] 0: Disabled 1: Enabled Device Information Call Display Setting 006 Displays or does not display the device information call content. [0 to 1 / 0 / 1 /step] 0: Not displayed 1: Displayed SSL Disable 007 Uses or does not use the RCG certification by SSL when calling the RCG. [0 to 1 / 0 / 1 /step] 0: Uses the RCG certification 1: Does no use the RCG certification 008 RCG Connect Timeout
SM 5-241 B230/B237 Service Tables Specifies the connect timeout interval when calling the RCG. [1 to 90 / 10 / 1 second /step] RCG Write Timeout 009 Specifies the write timeout interval when calling the RCG. [1 to 100 / 60 / 1 second /step] RCG Read Timeout 010 Specifies the read timeout interval when calling the RCG. [1 to 100 / 60 / 1 second /step] Port 80 Enable - 011 Enables/disables access via port 80 to the SOAP method. [0 or 1 / 0 / – ] 0: Disabled 1: Enabled RCG – C Registed 021 This SP displays the Cumin installation end flag. 0: Installation not completed 1: Installation completed RCG – C Registed Detail 022 This SP displays the Cumin installation status. 0: Basil not registered 1: Basil registered 2: Device registered Connect Type (N/M) 023 This SP displays and selects the Cumin connection method. [0 or 1 / 0 / 1 /step 0: Internet connection 1: Dial-up connection 061 Cert. Expire Timing DFUProximity of the expiration of the certification.
B230/B237 5-242 SM 062 Use Proxy This SP setting determines if the proxy server is used when the machine communicates with the service center. Proxy Host 063 This SP sets the address of the proxy server used for communication between Cumin-N and the gateway. Use this SP to set up or display the customer proxy server address. The address is necessary to set up Cumin-N. ƒ The address display is limited to 128 characters. Characters beyond the 128 character are ignored. ƒ This address is customer information and is not printed in the SMC report. Proxy Port Number 064 This SP sets the port number of the proxy server used for communication between Cumin-N and the gateway. This setting is necessary to set up Cumin-N. ƒ This port number is customer information and is not printed in the SMC report. Proxy User Name 065 This SP sets the HTTP proxy certification user name. ƒ The length of the name is limited to 31 characters. Any character beyond the 31st character is ignored. ƒ This name is customer information and is not printed in the SMC report. Proxy Password 066 This SP sets the HTTP proxy certification password. ƒ The length of the password is limited to 31 characters. Any character beyond the 31st character is ignored.
SM 5-243 B230/B237 Service Tables ƒ This name is customer information and is not printed in the SMC report. CERT: Up State Displays the status of the certification update. 0 The certification used by Cumin is set correctly. 1 The certification request (setAuthKey) for update has been received from the GW URL and certification is presently being updated. 2 The certification update is completed and the GW URL is being notified of the successful update. 3 The certification update failed, and the GW URL is being notified of the failed update. 4 The period of the certification has expired and new request for an update is being sent to the GW URL. 11 A rescue update for certification has been issued and a rescue certification setting is in progress for the rescue GW connection. 12 The rescue certification setting is completed and the GW URL is being notified of the certification update request. 13 The notification of the request for certification update has completed successfully, and the system is waiting for the certification update request from the rescue GW URL. 14 The notification of the certification request has been received from the rescue GW controller, and the certification is being stored. 15 The certification has been stored, and the GW URL is being notified of the successful completion of this event. 16 The storing of the certification has failed, and the GW URL is being notified of the failure of this event. 067 17 The certification update request has been received from the GW URL, the GW URL was notified of the results of the update after it was
B230/B237 5-244 SM completed, but an certification error has been received, and the rescue certification is being recorded. 18 The rescue certification of No. 17 has been recorded, and the GW URL is being notified of the failure of the certification update. CERT: Error Displays a number code that describes the reason for the request for update of the certification. 0 Normal. There is no request for certification update in progress. 1 Request for certification update in progress. The current certification has expired. 2 An SSL error notification has been issued. Issued after the certification has expired. 3 Notification of shift from a common authentication to an individual certification. 4 Notification of a common certification without ID2. 5 Notification that no certification was issued. 068 6 Notification that GW URL does not exist. 069 CERT: Up ID The ID of the request for certification. 083 Firmware Up Status Displays the status of the firmware update. 084 Non-HDD Firm Up This setting determines if the firmware can be updated, even without the HDD installed. 0: Not allowed update 1: Allowed update 085 Firm Up User Check This SP setting determines if the operator can confirm the previous version of the firmware before the firmware update execution. If the option to confirm the previous version is selected, a notification is sent to the system manager and the