SM 5-15 B230/B237 Service Tables Stop Time * ENG [5 to 30 / 10 / 1 sec/step] 003 Specifies the time for measuring the nip. 111 2 [Environmental Correction: Fusing] Temp.: Threshold: Low *ENG [10 to 23 / 17 / 1°C/step] 001 Specifies the threshold temperature for low temperature condition. Temp.: Threshold: High *ENG [24 to 40 / 30 / 1°C/step] 002 Specifies the threshold temperature for high temperature condition. Low Temp. Correction *ENG [0 to 15 / 5 / 1°C/step] 003 Specifies the temperature correction for the heating roller. When the low temperature condition (specified with SP1112-001) is detected, the value of this SP is added to the heating roller temperature. High Temp. Correction *ENG [0 to 15 / 5 / 1°C/step] 004 Specifies the temperature correction for the heating roller. When the high temperature condition (specified with SP1112-002) is detected, the value of this SP is subtracted from the heating roller temperature. 111 3 [Stand-by Time] After Ready *ENG [0 to 60 / 10 / 1 sec/step] 001 Specifies the interval from the ready mode to the stand-by mode. If the machine does not do any printing job for the time specified with this SP after the heating roller has reached the ready temperature, the machine returns to the stand-by mode. 002 Recovery Target Temp. *ENG [0 to 60 / 10 / 1 sec/step] Not used After Recovery *ENG [0 to 60 / 10 / 1 sec/step] 003 Specifies the interval from the recovery to the stand-by mode. If the machine does not do any printing job for the time specified with this SP
B230/B237 5-16 SM after the machine has recovered from the energy save mode, it returns to the stand-by mode. 111 4 [First Print Correction] Correction Temp. *ENG [0 to 30 / 10 / 1°C/step] 001 Specifies the additional temperature for the first print job. This temperature is added to the heating roller for the time specified with SP1114-002. Operation Time *ENG [0 to 60 / 2 / 1 sec/step] 002 Specifies the time for adding the first print additional temperature, which is specified with SP1114-001. Shift Time *ENG [0 to 5 / 0 / 0.1 sec/step] 003 Specifies the start time for adding the first print additional temperature at 138 mm/s line speed. The machine starts to add the first print additional temperature when the time specified with this SP has passed after feeding paper. Shift Time: Half Speed *ENG [0 to 5 / 0 / 0.1 sec/step] 004 Specifies the start time for adding the first print additional temperature at 77 mm/s line speed. The machine starts to add the first print additional temperature when the time specified with this SP has passed after feeding paper. 111 5 [Stand-by Idling] Interval *ENG [1 to 240 / 60 / 1 min/step] 001 Specifies the interval between idling during stand-by mode. This idling during the stand-by mode prevents the roller deformation. Idling Time *ENG [1 to 60 / 2 / 0.1 sec/step] 002 Specifies the length of each idling operation during stand-by mode.
SM 5-17 B230/B237 Service Tables 003 Idling Speed *ENG [0 to 3 / 1 / 1 mm/sec /step] Not used 111 6 [Ends Temp. Correction] Center Temp. 1: 226– *ENG [–30 to 0 / 0 / 1°C/step] 010 Specifies the temperature correction for the heating roller (center) when the paper width is 226 mm or more. The start time of this SP can be adjusted with SP1116-018. Ends Temp. 1: 226– *ENG [–30 to 0 / 0 / 1°C/step] 011 Specifies the temperature correction for the heating roller (ends) when the paper width is 226 mm or more. The start time of this SP can be adjusted with SP1116-018. Center Temp. 2: 226– *ENG [–30 to 0 / 0 / 1°C/step] 012 Specifies the temperature correction for the heating roller (center) when the paper width is 226 mm or more. The start time of this SP can be adjusted with SP1116-019. Ends Temp. 2: 226– *ENG [–30 to 0 / 0 / 1°C/step] 013 Specifies the temperature correction for the heating roller (ends) when the paper width is 226 mm or more. The start time of this SP can be adjusted with SP1116-019. Center Temp. 3: –226 *ENG [–30 to 0 / –5 / 1°C/step] 014 Specifies the temperature correction for the heating roller (center) when the paper width is less than 226 mm. The start time of this SP can be adjusted with SP1116-020. Ends Temp. 3: –226 *ENG [–30 to 0 / –5 / 1°C/step] 015 Specifies the temperature correction for the heating roller (ends) when the paper width is less than 226 mm. The start time of this SP can be adjusted with SP1116-020. 016 Center Temp. 4: –226 *ENG [–30 to 0 / –5 / 1°C/step]
B230/B237 5-18 SM Specifies the temperature correction for the heating roller (center) when the paper width is less than 226 mm. The start time of this SP can be adjusted with SP1116-021. Ends Temp. 4: –226 *ENG [–30 to 0 / –10 / 1°C/step] 017 Specifies the temperature correction for the heating roller (ends) when the paper width is less than 226 mm. The start time of this SP can be adjusted with SP1116-021. Control Time 1: 226– *ENG [0 to 250 / 0 / 1 sec/step] 018 Specifies the start time of the temperature correction that is set with SP1116-010 and -011. The temperature correction is added when the time specified with this SP has passed after feeding the paper. Control Time 2: 226– *ENG [0 to 250 / 0 / 1 sec/step] 019 Specifies the start time of the temperature correction that is set with SP1116-012 and -013. The temperature correction is added when the time specified with this SP has passed after feeding the paper. Control Time 3: –226 *ENG [0 to 250 / 30 / 1 sec/step] 020 Specifies the start time of the temperature correction that is set with SP1116-014 and -015. The temperature correction is added when the time specified with this SP has passed after feeding the paper. Control Time 4: –226 *ENG [0 to 250 / 60 / 1 sec/step] 021 Specifies the start time of the temperature correction that is set with SP1116-016 and -017. The temperature correction is added when the time specified with this SP has passed after feeding the paper. 022 Center Temp. 1 Duplex: 226– *ENG [–30 to 0 / 0 / 1°C/step]
SM 5-19 B230/B237 Service Tables Specifies the temperature correction for the heating roller (center) when the paper width is 226 mm or more in duplex mode. The start time of this SP can be adjusted with SP1116-026. Ends Temp. 1 Duplex: 226– *ENG [–30 to 0 / 0 / 1°C/step] 023 Specifies the temperature correction for the heating roller (ends) when the paper width is 226 mm or more in duplex mode. The start time of this SP can be adjusted with SP1116-026. Center Temp. 2 Duplex: 226– *ENG [–30 to 0 / 0 / 1°C/step] 024 Specifies the temperature correction for the heating roller (center) when the paper width is 226 mm or more in duplex mode. The start time of this SP can be adjusted with SP1116-027. Ends Temp. 2 Duplex: 226– *ENG [–30 to 0 / 0 / 1°C/step] 025 Specifies the temperature correction for the heating roller (ends) when the paper width is 226 mm or more in duplex mode. The start time of this SP can be adjusted with SP1116-027. Control Time 1 Duplex: 226– *ENG [0 to 250 / 0 / 1 sec/step] 026 Specifies the start time of the temperature correction that is set with SP1116-022 and -023. The temperature correction is added when the time specified with this SP has passed after feeding the paper. Control Time 2 Duplex: 226– *ENG [0 to 250 / 0 / 1 sec/step] 027 Specifies the start time of the temperature correction that is set with SP1116-024 and -025. The temperature correction is added when the time specified with this SP has passed after feeding the paper.
B230/B237 5-20 SM 111 7 [Idling Time After Heater OFF] After Ready *ENG [0 to10 / 4 / 1 sec/step] DFU 001 Specifies the idling time without the lamp on after reaching the ready temperature. After Job End *ENG [0 to10 / 4 / 1 sec/step] 002 Specifies the idling time without the lamp on after job end. This idling prevents the heating roller overheating after job end. 11 5 9 [Fusing Jam Detection] SC Display *ENG[0 or 1 / 0 / 1 /step] 0: Disable, 1: Enable 001 Enables or disables the fusing consecutive jam detection. If this SP is set to 1 (default: 0), SC559 occurs when the machine detects the paper jam three times consecutively at the fusing unit. 1801 [Motor Speed Adj.] FA 001 Registration: 77 *ENG 002 Registration: 138 *ENG 003 Registration: 150 *ENG[–4 to 4 / 0 / 0.05 %/step] 004 Bk PCU Drive: 154 *ENG [–4 to 4 / 0 / 0.01 %/step] Not used 005 Bk PCU Drive: 138 *ENG [–4 to 4 / 0.3 / 0.01 %/step] 006 Bk PCU Drive: 77 *ENG [–4 to 4 / 0.28 / 0.01 %/step] 007 MCY PCU Drive: 154 *ENG [–4 to 4 / 0 / 0.01 %/step] Not used 008 MCY PCU Drive: 138 *ENG [–4 to 4 / 0.3 / 0.01 %/step] 009 MCY PCU Drive: 77 *ENG [–4 to 4 / 0.28 / 0.01 %/step]
SM 5-21 B230/B237 Service Tables 010 MCY Development: 154 *ENG [–4 to 4 / 0 / 0.01 %/step] Not used 011 MCY Development: 138 *ENG [–4 to 4 / 0 / 0.01 %/step] 012 MCY Development: 77 *ENG [–4 to 4 / 0 / 0.01 %/step] 013 Fusing: 154 *ENG [–4 to 4 / 0 / 0.01 %/step] Not used 014 Fusing: 138 *ENG 015 Fusing: 77 *ENG[–4 to 4 / 0.4 / 0.01 %/step] 016 Image Transfer: 154 *ENG [–4 to 4 / 0 / 0.01 %/step] Not used 017 Image Transfer: 138 *ENG [–4 to 4 / 0.3 / 0.01 %/step] 018 Image Transfer: 77 *ENG [–4 to 4 / 0.28 / 0.01 %/step] 043 Registration: 77: Thin *ENG 044 Registration: 77: Middle thick *ENG[–4 to 4 / 0 / 0.05 %/step] 045 Registration: 77: Thick 1 *ENG 046 Registration: 77: Thick 2 *ENG 047 Registration: 77: Thick 3 *ENG[–4 to 4 / –0.4 / 0.05 %/step] 048 Registration: 138: Thin *ENG 049 Registration: 138: Middle Thick *ENG[–4 to 4 / 0 / 0.05 %/step] 1901 [Recovery Temp. Ope. Time] 004 - *ENG [0 to 60 / 10 / 1 sec/step] Not used 1903 [Drive Current Setting] 001 Duplex Motor Clockwise *ENG 002 Duplex Motor *ENG[0 or 1 / 0 / 1 /step] 0: Large Current, 1: Small Current
B230/B237 5-22 SM Counterclockwise 1907 [Paper Feed Timing Adj.] DFU 003 Feed Clutch OFF: Plain *ENG [–10 to 10 / 0 / 1 mm/step] 004 Feed Clutch ON: Plain *ENG [–10 to 10 / 0 / 1 mm/step] 005 Inverter Stop Position *ENG [–10 to 10 / 0 / 1 mm/step] 006 Exit Stop Position: 3rd Sheet *ENG [–10 to 10 / 0 / 1 mm/step] 011 Entrance Stop Position *ENG [–7 to 10 / 0 / 1 mm/step] 013 Feed Clutch OFF: Thick *ENG [–10 to 10 / 0 / 1 mm/step] 014 Feed Clutch ON: Thick *ENG [–10 to 10 / 0 / 1 mm/step] 015 Exit Stop Position: 1st/2nd Sheet *ENG [–10 to 10 / 0 / 1 mm/step] 016 By-pass Solenoid ON: Plain *ENG [–10 to 10 / 0 / 1 mm/step] 017 By-pass Solenoid ON: Thick *ENG [–10 to 10 / 0 / 1 mm/step] 1908 [Paper Bank Feed Timing Adj.] DFU 001 Paper Pre-Feed *ENG [0 or 1 / 0 / 1 /step] 002 Feed Solenoid ON: Plain *ENG [–10 to 40 / 0 / 2.5 mm/step] 003 Feed Solenoid ON: Thick *ENG [–10 to 40 / 0 / 2.5 mm/step] 004 Feed Clutch OFF: Plain *ENG [–10 to 10 / 0 / 1 mm/step] 005 Feed Clutch OFF: Thick *ENG [–10 to 10 / 0 / 1 mm/step] 006 Feed Clutch ON: Plain *ENG [–10 to 10 / 0 / 1 mm/step]
SM 5-23 B230/B237 Service Tables 007 Feed Clutch ON: Thick *ENG [–10 to 10 / 0 / 1 mm/step] SP2-XXX (Drum) 2005 [Charge DC Voltage] Charge Roller DC Voltage Adjustment (Paper Type, Process Speed, Color) Paper Type –> Plain, Thick 1, Thick 2 Adjusts the DC component of the charge roller bias in the various print modes. Charge bias (DC component) is automatically adjusted during process control; therefore, adjusting these settings does not effect while process control mode (SP3-041-1 Default: ON) is activated. When deactivating process control mode with SP3-041-1, the values in these SP modes are used for printing. 001 Plain: Bk *ENG 002 Plain: M *ENG 003 Plain: C *ENG 004 Plain: Y *ENG 005 Thick 1: Bk *ENG 006 Thick 1: M *ENG 007 Thick 1: C *ENG 008 Thick 1: Y *ENG 009 Thick 2&FINE: Bk *ENG 010 Thick 2&FINE: M *ENG 011 Thick 2&FINE: C *ENG 012 Thick 2&FINE: Y *ENG[0 to 1000 / 690 / 10 –volts/step] [Charge AC Voltage] Charge Roller AC Voltage Adjustment (Paper Type, Process Speed, Color) Paper Type –> Plain, Thick 1, Thick 2 2006 Adjusts the AC component of the charge roller bias in the various print modes.
B230/B237 5-24 SM Charge bias (AC component) is adjusted by environment correction (SP2-007-xxx to SP2-011-xxx). These SPs are activated only when SP2-012-1 is set to 1: manual control. 001 Plain: Bk *ENG 002 Plain: M *ENG 003 Plain: C *ENG 004 Plain: Y *ENG 005 Thick 1: Bk *ENG 006 Thick 1: M *ENG 007 Thick 1: C *ENG 008 Thick 1: Y *ENG 009 Thick 2&FINE: Bk *ENG 010 Thick 2&FINE: M *ENG 011 Thick 2&FINE: C *ENG 012 Thick 2&FINE: Y *ENG[0 to 3000 / 2100 / 10 V/step] [Charge AC Current: LL] Charge Roller AC Current Adjustment for LL (Color) 2007 Displays/sets the AC current target of the charge roller for LL environment (Low temperature and Low humidity). DFU 001 Environmental Target: Bk *ENG 002 Environmental Target: M *ENG 003 Environmental Target: C *ENG[0 to 3000 / 1060 / 10 μA/step] 004 Environmental Target: Y *ENG [0 to 3000 / 1100 / 10 μA/step]