Ricoh B230 Service Manual
Have a look at the manual Ricoh B230 Service Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 127 Ricoh manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
SM 5-165 B230/B237 Service Tables [ID Sensor Detection Value: Vsgave] 3313 Not used 001 Vsgave reg: Bk *ENG 002 Vsgave reg: M *ENG 003 Vsgave reg: C *ENG 004 Vsgave reg: Y *ENG[0 to 5.5 / - / 0.01 V/step] 005-007 Not used 005 Vsgave dif: M *ENG 006 Vsgave dif: C *ENG 007 Vsgave dif: Y *ENG[0 to 5.5 / - / 0.01 V/step] 008-010 Not used 008 Vsgave TM (Front) *ENG 009 Vsgave TM (Center) *ENG 010 Vsgave TM (Rear) *ENG[0 to 5.5 / - / 0.01 V/step] 3321 [Vsg Adjustment: Execution] 010 P/TM Sensor All - Execute the ID sensor initialization setting for all sensors [Vsg Adjustment Result: Vsg] 3322 Displays the result value of the Vsg adjustment for each sensor. 001 Vsg reg: Bk *ENG 002 Vsg reg: M *ENG 003 Vsg reg: C *ENG[0 to 5.5 / - / 0.01 V/step]
B230/B237 5-166 SM 004 Vsg reg: Y *ENG 005 Vsg dif: M *ENG 006 Vsg dif: C *ENG 007 Vsg dif: Y *ENG[0 to 5.5 / - / 0.01 V/step] 008 Vsg TM (Front) *ENG 009 Vsg TM (Center) *ENG 010 Vsg TM (Rear) *ENG[0 to 5.5 / - / 0.01 V/step] 3323 [Vsg Adjustment Result: Ifsg] DFU 001 Ifsg: Bk *ENG 002 Ifsg: M *ENG 003 Ifsg: C *ENG 004 Ifsg: Y *ENG[0 to 50 / - / 0.1 mA/step] 005 Ifsg TM (Front) *ENG 006 Ifsg TM (Center) *ENG 007 Ifsg TM (Rear) *ENG[0 to 50 / - / 0.1 mA/step] 3324 [Vsg Adjustment: Set] DFU 002 Vofset Error Counter *ENG 003 Vofset Error Counter *ENG[0 to 99 / - / 0.1 time/step] 004 Vofset Threshold *ENG [0 to 5 / 1 / 0.01 V/step] 005 Vsg Upper Threshold *ENG [0 to 5 / 4.5 / 0.01 V/step] 006 Vsg Lower Threshold *ENG [0 to 5 / 3.5 / 0.01 V/step]
SM 5-167 B230/B237 Service Tables [Vsg Adjustment Result] 3325 Displays the result of the Vsg adjustment. The displayed numbers mean the result of each sensor (sensor for Front, sensor for Bk, sensor for Cyan, sensor for Center, sensor for Magenta, sensor for Yellow and sensor for Rear). 001 Latest *ENG 002 Latest 1 *ENG 003 Latest 2 *ENG 004 Latest 3 *ENG 005 Latest 4 *ENG 006 Latest 5 *ENG 007 Latest 6 *ENG 008 Latest 7 *ENG 009 Latest 8 *ENG 010 Latest 9 *ENG[ 1111111 t o 9999999 / 9999999 / 1 /step] 9: Unexpected error 3: Offset voltage error 2: Vsg adjustment value error 1: O.K 3361 [ID Sensor Sensitivity: Display] Not Used 001 K2K (Latest) *ENG 002 K5K (Latest) *ENG 003 K2M (Latest) *ENG 004 K5M (Latest) *ENG 005 K2C (Latest) *ENG 006 K5C (Latest) *ENG 007 K2Y (Latest) *ENG 008 K5Y (Latest) *ENG[0 to 5 / - / 0.0001 /step]
B230/B237 5-168 SM 3362 [ID Sensor Sensitivity: Setting] DFU 001 K2: Upper *ENG [0 to 1 / 0.32 / 0.01 /step] 002 K2: Lower *ENG [0 to 1 / 0.22 / 0.01 /step] 003 K5: Upper *ENG [0 to 10 / 5 / 0.01 /step] 004 K5: Lower *ENG [0 to 10 / 0.5 / 0.01 /step] 005 Kn: Lower *ENG [0 to 1 / 0.1 / 0.01 /step] 006 Kn: Upper *ENG [0 to 1 / 1 / 0.01 /step] 007 K5 Edit Point *ENG [0 to 1 / 0.15 / 0.01 /step] 008 K5 Target Voltage *ENG [0 to 5 / 1.63 / 0.01 V/step] 009 K5 Approximate Method *ENG[0 to 1 / 1 / 1 /step] 0:Linear, 1: Curve 010 K2: Upper/Lower Limit Coefficient 1 *ENG [0 to 1 / 0 / 0.01 /step] 011 K2: Upper Limit Correction *ENG [–0.2 to 0.4 / 0.07 / 0.01 /step] 012 K2: Lower Limit Correction *ENG [–0.2 to 0.4 / –0.07 / 0.01 /step] 013 Diffusion Correction: M *ENG 014 Diffusion Correction: C *ENG 015 Diffusion Correction: Y *ENG[0.75 to 1.35 / 1 / 0.01 /step] 016 K2: Check: M *ENG 017 K2: Check: C *ENG 018 K2: Check: Y *ENG[0 to 1 / 0.25 / 0.001 /step]
SM 5-169 B230/B237 Service Tables 3363 [ID Pattern Timing Setting] DFU 001 Scan YCMBk *ENGAdjusts the detection timing for the process control pattern. [-500 to 500 / 13.7 / 1 mm/step] 002 Paper Transfer Release Start Ti m e *ENGAdjusts the timing when the paper transfer unit is kept away from the image transfer belt. [0 to 2500 / 0 / 1 msec/step] 003 Delay Time *ENGAdjusts the processing timing for the process control pattern. [0 to 2500 / 600 / 1 msec/step] 004 MUSIC Delay Time *ENGAdjusts the processing timing for the pattern that is used for the line position adjustment. [-2500 to 2500 / 300 / 1 msec/step] 3371 [M/A Calculation] DFU 001 Correction Coefficient: Bk *ENG [0.5 to 2.0 / 1.04 / 0.01 /step] 002 Correction Coefficient: M *ENG [0.5 to 2.0 / 0.98 / 0.01 /step] 003 Correction Coefficient: C *ENG [0.5 to 2.0 / 1.11 / 0.01 /step] 004 Correction Coefficient: Y *ENG [0.5 to 2.0 / 0.91 / 0.01 /step] [Fixed Supply Mode] 3401 Adjusts the toner supply rate in the fixed toner supply mode. 001 Fixed Rate: Bk *ENG 002 Fixed Rate: M *ENG 003 Fixed Rate: C *ENG[0 to 100 / 5 / 1 %/step] These SPs are used only when SP3-044 is set to 1.
B230/B237 5-170 SM 004 Fixed Rate: Y *ENG [Toner Supply Rate: Display] 3411 Displays the current toner supply rate. 001 Latest: Bk *ENG 002 Latest: M *ENG 003 Latest: C *ENG 004 Latest: Y *ENG[0 to 100 / - / 1 %/step] 3421 [Toner Supply Range] 001 Upper Limit: Bk *ENG 002 Upper Limit: M *ENG 003 Upper Limit: C *ENG 004 Upper Limit: Y *ENGAdjusts the toner supply rate during printing. [0 to 100 / 100 / 1%/step] 005 Minimum Supply Time: Bk *ENG 006 Minimum Supply Time: M *ENG 007 Minimum Supply Time: C *ENG 008 Minimum Supply Time: Y *ENGAdjusts the minimum toner supply time. [0 to 1000 / 0 / 1 msec/step] 3451 [Toner Supply Carry Over: Display] DFU 001 Bk *ENG 002 M *ENG 003 C *ENG 004 Y *ENG[0 to 10000 / 0 / 1 msec/step]
SM 5-171 B230/B237 Service Tables 3452 [Toner Supply Carry Over: Setting] DFU 001 Maximum: Bk *ENG 002 Maximum: M *ENG 003 Maximum: C *ENG 004 Maximum: Y *ENG[0 to 10000 / 1000 / 1 msec/step] [Process Control Target M/A] 3501 Adjusts the target M/A. 001 Maximum M/A: Bk *ENG 002 Maximum M/A: M *ENG 003 Maximum M/A: C *ENG[0 to 1 / 0.42 / 0.001 mg/cm 2/step] 004 Maximum M/A: Y *ENG [0 to 1 / 0.43 / 0.001 mg/cm2/step] [Image Quality Adj. Counter: Display] 3510 Displays the total page counter for each adjustment mode. 001 Potential Control: BW *ENG 002 Potential Control: FC *ENG 003 Power ON: BW *ENG 004 Power ON: FC *ENG 005 MUSIC: BW *ENG 006 MUSIC: FC *ENG 007 Vsg Adj. *ENG 008 Charge AC Control *ENG[0 to 2000 / 0 / 1 page/step]
B230/B237 5-172 SM [Execution Interval: Setting] 3511 Adjusts the threshold for each adjustment mode. 001 Job End: Potential Control: BW *ENG [0 to 2000 / 250 / 1 page/step] 002 Job End: Potential Control: FC *ENG [0 to 2000 / 100 / 1 page/step] 003 Interrupt: Potential Control: BW *ENG [0 to 2000 / 500 / 1 page/step] 004 Interrupt: Potential Control: FC *ENG [0 to 2000 / 200 / 1 page/step] 005 Initial: Potential Control: BW *ENG [0 to 2000 / 200 / 1 page/step] 006 Initial: Potential Control: FC *ENG [0 to 2000 / 100 / 1 page/step] 007 Vsg Adj. Counter *ENG [0 to 2000 / 500 / 1 page/step] 008 Charge AC Control Counter *ENG [0 to 2000 / 500 / 1 page/step] 019 Environmental Correction *ENG[0 or 1 / 1 / 1 /step] 0: Not Correct (OFF), 1: Correct (ON) 020 Gamma Correction *ENG[0 or 1 / 1 / 1 /step] 0: Not Correct (OFF), 1: Correct (ON) 021 Non-use Time Correction *ENG[0 or 1 / 1 / 1 /step] 0: Not Correct (OFF), 1: Correct (ON) 022 Correction Coefficient 1: JE: BW *ENG [0 to 1 / 0.2 / 0.01 page/step] 023 Correction Coefficient 2: JE: BW *ENG [0 to 1 / 1 / 0.01/step] 024 Correction Coefficient 1: *ENG [0 to 1 / 0.5 / 0.01/step]
SM 5-173 B230/B237 Service Tables JE: FC 025 Correction Coefficient 2: JE: FC *ENG [0 to 1 / 1 / 0.01/step] 026 Correction Coefficient 1: Interrupt: BW *ENG [0 to 1 / 0.1 / 0.01/step] 027 Correction Coefficient 2: Interrupt: BW *ENG [0 to 1 / 1 / 0.01/step] 028 Correction Coefficient 1: Interrupt: FC *ENG [0 to 1 / 0.25 / 0.01/step] 029 Correction Coefficient 2: Interrupt: FC *ENG [0 to 1 / 1 / 0.01/step] 030 Max. Number Correction Threshold *ENG [0 to 99 / 2 / 1/step] 031 Max. Number Correction Counter *ENG [0 to 255 / 0 / 1/step] [Image Quality Adj.: Interval] 3512 Adjusts the timing for execution of process control and line position adjustment. 001 During Job *ENG [0 to 100 / 30 / 1 page/step] 002 During Stand-by *ENG [0 to 100 / 10 / 1 minute/step] [PCU Motor Stop Time: Bk] 3513 Displays the last time that the PCU motors stopped. These are used for process control execution timing. 001 Year *ENG [0 to 99 / 0 / 1/step] 002 Month *ENG [1 to 12 / 1 / 1/step] 003 Date *ENG [1 to 31 / 1 / 1/step]
B230/B237 5-174 SM 004 Hour *ENG [0 to 23 / 0 / 1/step] 005 Minute *ENG [0 to 59 / 0 / 1/step] [Environmental Display: Job End] 3514 Displays the environmental conditions for the last job. These are used for process control execution timing. 001 Temperature *ENG [-1280 to 1270 / 0 / 0.1°C/step] 002 Relative Humidity *ENG [0 to 1000 / - / 0.1%RH/step] 003 Absolute Humidity *ENG [0 to 1000 / - / 0.1 g/cm3/step] [Execution Interval: Display] 3515 Displays the current interval for process control execution. When the machine calculates the timing for process control, it uses a number of conditions. These are the results after considering all the conditions. 001 Job End: Potential Control: BW *ENG [0 to 2000 / – / 1 page/step] 002 Job End: Potential Control: FC *ENG [0 to 2000 / – / 1 page/step] 003 Interrupt: Potential Control: BW *ENG [0 to 2000 / – / 1 page/step] 004 Interrupt: Potential Control: FC *ENG [0 to 2000 / – / 1 page/step] [Refresh Mode] DFU 3516 While making prints with low coverage, the developer is agitated with less toner consumption and the toner carrier attraction tends to increase. This may cause low image density or poor transfer (white dots). To prevent this, the coagulated toner or overcharged toner has to be consumed by performing the refresh