    SM 5-175 B230/B237 
    Service 
    Tables 
    mode. 
    001 Dev. Motor Rotation: 
    Display: Bk *ENG
    002 Dev. Motor Rotation: 
    Display: M *ENG
    003 Dev. Motor Rotation: 
    Display: C *ENG
    004 Dev. Motor Rotation: 
    Display: Y *ENG[0 to 1000 / 0 / 1 m/step] 
    005 Rotation Threshold  *ENG
    [0 to 1000 / 1 / 1 m/step] 
    006  Pixel Coverage Sum: Bk  *ENG
    007  Pixel Coverage Sum: M  *ENG
    008  Pixel Coverage Sum: C  *ENG
    009  Pixel Coverage Sum: Y  *ENG[0 to 65535 / 0 / 1 cm
    2/step] 
    010 Required Area: Bk  *ENG
    011 Required Area: M  *ENG
    012 Required Area: C  *ENG
    013 Required Area: Y  *ENG[0 to 65535 / 0 / 1 cm
    2/step] 
    014 Refresh Threshold: Bk  *ENG
    015 Refresh Threshold: M  *ENG
    016 Refresh Threshold: C  *ENG
    017  Refresh Threshold: Y  *ENG[0 to 255 / 14 / 1 cm
    2/m/step] 
    018 Pattern Generation 
    Number: Bk *ENG
    019 Pattern Generation  *ENG[0 to 255 / 0 / 1 time/step]  
    						
    							 
    B230/B237 5-176  SM 
    Number: M 
    020 Pattern Generation 
    Number: C *ENG
    021 Pattern Generation 
    Number: Y *ENG
    022 Pattern Generation 
    Number: Upper limit *ENG
    [0 to 255 / 0 / 1 time/step] 
    023 Toner Consumption 
    Pattern Area *ENG
    [10 to 2550 / 320 / 10 cm2/step] 
    024 Supply Coefficient  *ENG
    [0 to 2.55 / 1 / 0.01/step] 
    025  Job End Area Coefficient  *ENG
    [0.1 to 25.5 / 1 / 0.1/step] 
    026  Job End Vb Coefficient  *ENG
    [0 to 100 / 40 / 1%/step] 
    027  Job End Length  *ENG
    [0 to 56 / 12 / 1mm/step] 
    028  Job End Supply  *ENG [0 to 1 / 0.45 / 0.001 mg/cm2/step] 
     
    [Blade damage prevention mode] 
    3517 Adjusts the threshold temperature for preventing the cleaning blade at the drum 
    unit from being damaged. If the temperature is above this value, the drum 
    reverses briefly at the end of the job to prevent the blade from flipping over. 
    001 Execution Temp. 
    Threshold *ENG
    [0 to 50/ 40 / 1°C/step] 
     
    3518 [Image Quality Adj. Execution Flag] DFU 
    001  Toner End Recovery: Bk  *ENG
    002  Toner End Recovery: M  *ENG
    003  Toner End Recovery: C  *ENG[0 or 1 / 0 / 1/step]   
    0: OFF. 1: ON  
    						
    							 
    SM 5-177 B230/B237 
    Service 
    Tables 
    004  Toner End Recovery: Y  *ENG
    005 Vsg Adj.  *ENG[0 or 1 / 0 / 1/step] 
    0: OFF. 1: ON 
    006 Developer Mixing  *ENG[0 or 1 / 0 / 1/step] 
    0: OFF. 1: ON 
    007 Process Control  *ENG[0 or 1 / 0 / 1/step] 
    0: OFF. 1: ON 
    008 MUSIC  *ENG[0 or 1 / 0 / 1/step] 
    0: OFF. 1: ON 
    009 MUSIC (Skew 
    Correction) *ENG[0 or 1 / 0 / 1/step] 
    0: OFF. 1: ON 
    010 Charge AC Control  *ENG[0 or 1 / 0 / 1/step] 
    0: OFF. 1: ON 
    011 Blade Damage 
    Prevention *ENG[0 or 1 / 0 / 1/step] 
    0: OFF. 1: ON 
     
    [Toner End Prohibition Setting] 
    3519 
    Enables or disables each adjustment at toner near end. 
    001 Process Control  *ENG
    002 MUSIC  *ENG
    003 TC Adj.  *ENG[0 or 1 / 0 / 1/step]   
    0: Permit (adjustment is done even toner 
    near end condition) 
    1: Forbid (adjustment is not done at toner 
    near end condition) 
     
    [Initial Process Control Setting] 
    3522 Adjusts the threshold for the process control at power on.   
    When the current condition has changed by more than the values of these SPs 
    when compared with the conditions at the previous operation, the process 
    control at power on is executed.  
    						
    							 
    B230/B237 5-178  SM 
    002 Non-use Time Setting  *ENG
    [0 to 1440 / 360 / 1 minute/step]  
    003 Temperature Range  *ENG
    [0 to 99 / 10 / 1°C/step] 
    004  Relative Humidity Range  *ENG
    [0 to 99 / 50 / 1 %RH/step] 
    005  Absolute Humidity Range *ENG
    [0 to 99 / 6 / 1 g/m3/step] 
     
    [Non-use Time Process Control Setting] 
    3531 Adjusts the threshold for the process control at stand-by.   
    When the current condition has changed by more than the values of these SPs 
    when compared with the conditions at the previous operation, the process 
    control at stand-by is executed. 
    001 Non-use Time Setting  *ENG
    [0 to 1440 / 360 / 1 minute/step]  
    002 Temperature Range  *ENG
    [0 to 99 / 10 / 1°C/step] 
    003  Relative Humidity Range  *ENG
    [0 to 99 / 50 / 1 %RH/step] 
    004  Absolute Humidity Range *ENG
    [0 to 99 / 6 / 1 g/m3/step] 
    005 Maximum Execution 
    Number *ENGAdjusts the maximum execution time for the 
    process control at stand-by. 
    [0 to 99 / 10 / 1 time/step] 
     
    3611 [Development Gamma: Display/Set] 
    001 Bk (Current)  *ENG
    002 M (Current)  *ENG
    003 C (Current)  *ENG
    004 Y (Current)  *ENGDisplays the current development gamma 
    for each color. 
    [0 to 5 / - / 0.01 mg/cm
    2/kV /step] 
    005  Bk (Target Display)  *ENG
    006  M (Target Display)  *ENGDisplays the target development gamma for 
    each color.   
    [0 to 5 / 0.85 / 0.01 mg/cm2/kV /step]  
    						
    							 
    SM 5-179 B230/B237 
    Service 
    Tables 
    007  C (Target Display)  *ENG
    008  Y (Target Display)  *ENGDisplays the target development gamma for 
    each color.   
    [0 to 5 / 0.8 / 0.01 mg/cm2/kV /step] 
    009  Bk (Standard Target Set)  *ENGDisplays the standard target development 
    gamma for each color.   
    [0 to 5 / 0.9 / 0.01 mg/cm
    2/kV /step] 
    010  M (Standard Target Set)  *ENG
    011  C (Standard Target Set)  *ENG
    012  Y (Standard Target Set)  *ENG[0 to 5 / 0.8 / 0.01 mg/cm
    2/kV /step] 
    013 Environmental Correction *ENGTurns on or off the environmental correction 
    for target development gamma. 
    [0 or 1 / 1 / - ] 
    0: Not Correct, 1: Correct 
     
    [Vk Display] 
    3612 
    Displays Vk for each color. 
    001 Bk  *ENG
    002 M  *ENG
    003 C  *ENG
    004 Y  *ENG[-300 to 300 / - / 1 V/step] 
     
    [Development DC Control: Display] 
    Plain: 138 mm/sec, Thick 2 and Fin: 77 mm/sec 
    3621 
    Displays the development DC bias adjusted with the process control for each 
    line speed and color. 
    001 Plain: Bk  *ENG
    002 Plain: M  *ENG[0 to 700 / 550 / 1 -V/step]  
    						
    							 
    B230/B237 5-180  SM 
    003 Plain: C  *ENG
    004 Plain: Y  *ENG
    009  Thick 2 & FINE: Bk  *ENG
    010  Thick 2 & FINE: M  *ENG
    011  Thick 2 & FINE: C  *ENG
    012  Thick 2 & FINE: Y  *ENG[0 to 700 / 550 / 1 -V/step] 
     
    [Charge DC Control: Display] 
    Plain: 138 mm/sec, Thick 2 and Fin: 77 mm/sec 
    3631 
    Displays the charge DC voltage adjusted with the process control for each line 
    speed and color. 
    001 Plain: Bk  *ENG
    002 Plain: M  *ENG
    003 Plain: C  *ENG
    004 Plain: Y  *ENG[0 to 2000 / 690 / 1 -V/step] 
    009  Thick 2 & FINE: Bk  *ENG
    010  Thick 2 & FINE: M  *ENG
    011  Thick 2 & FINE: C  *ENG
    012  Thick 2 & FINE: Y  *ENG[0 to 2000 / 690 / 1 -V/step] 
     
    [Charge AC Control: Display] 
    Plain: 138 mm/sec, Thick 2 and Fin: 77 mm/sec 
    3641 
    Displays the charge AC voltage adjusted with the process control for each 
    color. 
    001 Plain: Bk  *ENG
    [0 to 3 / 1.75 / 0.01 kV/step]  
    						
    							 
    SM 5-181 B230/B237 
    Service 
    Tables 
    002 Plain: M  *ENG
    003 Plain: C  *ENG
    004 Plain: Y  *ENG
     
    [LD Power Control: Display] 
    Plain: 138 mm/sec, Thick 2 and Fin: 77 mm/sec 
    3651 
    Displays the LD power adjusted for each environment. 
    001 Plain: Bk  *ENG
    002 Plain: M  *ENG
    003 Plain: C  *ENG
    004 Plain: Y  *ENG[0 to 200 / 100 / 1 %/step] 
    009  Thick 2 & FINE: Bk  *ENG
    010  Thick 2 & FINE: M  *ENG
    011  Thick 2 & FINE: C  *ENG
    012  Thick 2 & FINE: Y  *ENG[0 to 200 / 100 / 1 %/step] 
     
    [HST Concentration Control: Set]  
    TD Sensor: Toner Concentration Control Setting 
    3710 
    Selects the toner concentration control method by HST memory, which is in the 
    TD sensor. 
    001 Control Method: 
    Selection *ENG[0 or 1 / 1 / - ] 
    0: Not Use, 1: Use 
     
    [HST Concentration Control: Bk] 
    3711 
    Displays the factory settings of the black PCU.   
    001 Vcnt  *ENG
    [0 to 5 / 4 / 0.1 V/step]  
    						
    							 
    B230/B237 5-182  SM 
    002 Vt  *ENG
    [0 to 5 / 2.5 / 0.1 V/step] 
    003 Sensitivity: HL  *ENG
    [0 to 5 / 2.5 / 0.1 V/step] 
    004 Sensitivity: HM  *ENG
    [0 to 5 / 1.3 / 0.1 V/step] 
    005 Sensitivity: ML  *ENG
    [0 to 5 / 1.2 / 0.1 V/step] 
    006 Set Detection  *ENG
    [0 to 5 / 1 / 0.1 V/step] 
    007 Without Developer  *ENG
    [0 to 5 / 1.2 / 0.1 V/step] 
    008 With Developer  *ENG
    [0 to 5 / 1.3 / 0.1 V/step] 
    009  Serial Number 1  *ENG
    010  Serial Number 2  *ENG[0 to 255 / - / 1 V/step] 
    011 Adjustment: Vt  *ENG
    [0 to 5 / 3 / 0.1 V/step] 
    012 Adjustment: Vtref  *ENG
    [0 to 5 / 3 / 0.1 V/step] 
    013 Adjustment: Vtcnt  *ENG
    [0 to 5 / 4 / 0.01 V/step] 
    014 Adjustment: Gamma  *ENG
    [0 to 2.55 / 0 / 0.01 mg/cm2/kV /step] 
    015  Adjustment: Vcnt Result  *ENG
    [0 to 9 / 9 / 1 /step] 
     
    [HST Concentration Control: M] 
    3712 
    Displays the factory settings of the magenta PCU.   
    001 Vcnt  *ENG
    [0 to 5 / 4 / 0.1 V/step] 
    002 Vt  *ENG
    [0 to 5 / 2.5 / 0.1 V/step] 
    003 Sensitivity: HL  *ENG
    [0 to 5 / 2.5 / 0.1 V/step] 
    004 Sensitivity: HM  *ENG
    [0 to 5 / 1.3 / 0.1 V/step] 
    005 Sensitivity: ML  *ENG
    [0 to 5 / 1.2 / 0.1 V/step] 
    006 Set Detection  *ENG
    [0 to 5 / 1 / 0.1 V/step] 
    007 Without Developer  *ENG
    [0 to 5 / 1.2 / 0.1 V/step]  
    						
    							 
    SM 5-183 B230/B237 
    Service 
    Tables 
    008 With Developer  *ENG
    [0 to 5 / 1.3 / 0.1 V/step] 
    009  Serial Number 1  *ENG
    010  Serial Number 2  *ENG[0 to 255 / - / 1 V/step] 
    011 Adjustment: Vt  *ENG
    [0 to 5 / 3 / 0.1 V/step] 
    012 Adjustment: Vtref  *ENG
    [0 to 5 / 3 / 0.1 V/step] 
    013 Adjustment: Vtcnt  *ENG
    [0 to 5 / 4 / 0.01 V/step] 
    014 Adjustment: Gamma  *ENG
    [0 to 2.55 / 0 / 0.01 mg/cm2/kV /step] 
    015  Adjustment: Vcnt Result  *ENG
    [0 to 9 / 9 / 1 /step] 
     
    [HST Concentration Control: C] 
    3713 
    Displays the factory settings of the cyan PCU.   
    001 Vcnt  *ENG
    [0 to 5 / 4 / 0.1 V/step] 
    002 Vt  *ENG
    [0 to 5 / 2.5 / 0.1 V/step] 
    003 Sensitivity: HL  *ENG
    [0 to 5 / 2.5 / 0.1 V/step] 
    004 Sensitivity: HM  *ENG
    [0 to 5 / 1.3 / 0.1 V/step] 
    005 Sensitivity: ML  *ENG
    [0 to 5 / 1.2 / 0.1 V/step] 
    006 Set Detection  *ENG
    [0 to 5 / 1 / 0.1 V/step] 
    007 Without Developer  *ENG
    [0 to 5 / 1.2 / 0.1 V/step] 
    008 With Developer  *ENG
    [0 to 5 / 1.3 / 0.1 V/step] 
    009  Serial Number 1  *ENG
    010  Serial Number 2  *ENG[0 to 255 / - / 1 V/step] 
    011 Adjustment: Vt  *ENG
    [0 to 5 / 3 / 0.1 V/step] 
    012 Adjustment: Vtref  *ENG
    [0 to 5 / 3 / 0.1 V/step] 
    013 Adjustment: Vtcnt  *ENG
    [0 to 5 / 4 / 0.01 V/step]  
    						
    							 
    B230/B237 5-184  SM 
    014 Adjustment: Gamma  *ENG
    [0 to 2.55 / 0 / 0.01 mg/cm2/kV /step] 
    015  Adjustment: Vcnt Result  *ENG
    [0 to 9 / 9 / 1 /step] 
     
    [HST Concentration Control: Y] 
    3714 
    Displays the factory settings of the yellow PCU.   
    001 Vcnt  *ENG
    [0 to 5 / 4 / 0.1 V/step] 
    002 Vt  *ENG
    [0 to 5 / 2.5 / 0.1 V/step] 
    003 Sensitivity: HL  *ENG
    [0 to 5 / 2.5 / 0.1 V/step] 
    004 Sensitivity: HM  *ENG
    [0 to 5 / 1.3 / 0.1 V/step] 
    005 Sensitivity: ML  *ENG
    [0 to 5 / 1.2 / 0.1 V/step] 
    006 Set Detection  *ENG
    [0 to 5 / 1 / 0.1 V/step] 
    007 Without Developer  *ENG
    [0 to 5 / 1.2 / 0.1 V/step] 
    008 With Developer  *ENG
    [0 to 5 / 1.3 / 0.1 V/step] 
    009  Serial Number 1  *ENG
    010  Serial Number 2  *ENG[0 to 255 / - / 1 V/step] 
    011 Adjustment: Vt  *ENG
    [0 to 5 / 3 / 0.1 V/step] 
    012 Adjustment: Vtref  *ENG
    [0 to 5 / 3 / 0.1 V/step] 
    013 Adjustment: Vtcnt  *ENG
    [0 to 5 / 4 / 0.01 V/step] 
    014 Adjustment: Gamma  *ENG
    [0 to 2.55 / 0 / 0.01 mg/cm2/kV /step] 
    015  Adjustment: Vcnt Result  *ENG
    [0 to 9 / 9 / 1 /step] 
     
    [Toner Collection Bottle Full Detection] 
    3800 
    Displays/ adjusts the toner collection bottle detection settings. These SPs are 
    used for NRS.  
    						
    All Ricoh manuals Comments (0)