Ricoh B230 Service Manual
Have a look at the manual Ricoh B230 Service Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 127 Ricoh manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
SM 4-21 B230/B237 Trouble shooting No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures) FGATE ON error: Bk The PFGATE ON signal does not assert within 5 seconds after processing the image in normal job or MUSIC for start position [K]. ƒ Defective ASIC (Lupus) ƒ Poor connection between controller and BICU. ƒ Defective BICU 230 D 1. Check the connection between the controller board and the BICU. 2. Replace the BICU. 3. Replace the controller board. No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures) FGATE OFF error: Bk ƒ The PFGATE ON signal still asserts within 5 seconds after processing the image in normal job or MUSIC for end position [K]. ƒ The PFGATE ON signal still asserts when the next job starts. 231 D See SC 230 for troubleshooting details. No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures) FGATE ON error: Y The PFGATE ON signal does not assert within 5 seconds after processing the image in normal job or MUSIC for start position [Y]. 232 D See SC 230 for troubleshooting details.
B230/B237 4-22 SM No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures) FGATE OFF error: Y ƒ The PFGATE ON signal still asserts within 5 seconds after processing the image in normal job or MUSIC for end position [Y]. ƒ The PFGATE ON signal still asserts when the next job starts. 233 D See SC 230 for troubleshooting details. No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures) FGATE ON error: M The PFGATE ON signal does not assert within 5 seconds after processing the image in normal job or MUSIC for start position [M]. 234 D See SC 230 for troubleshooting details. No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures) FGATE OFF error: M ƒ The PFGATE ON signal still asserts within 5 seconds after processing the image in normal job or MUSIC for end position [M]. ƒ The PFGATE ON signal still asserts when the next job starts. 235 D See SC 230 for troubleshooting details. No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures) FGATE ON error: C The PFGATE ON signal does not assert within 5 seconds after processing the image in normal job or MUSIC for start position [C]. 236 D See SC 230 for troubleshooting details.
SM 4-23 B230/B237 Trouble shooting No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures) FGATE OFF error: C ƒ The PFGATE ON signal still asserts within 5 seconds after processing the image in normal job or MUSIC for end position [C]. ƒ The PFGATE ON signal still asserts when the next job starts. 237 D See SC 230 for troubleshooting details. No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures) 240 C LD error: Bk 241 C LD error: Y 242 C LD error: M 243 C LD error: C The BICU detects LDB error a few times consecutively when LDB unit turns on after LDB initialization. ƒ Worn-out LD ƒ Disconnected or broken harness of the LD 1. Replace the harness of the LD. 2. Replace the laser optics housing unit. 3. Replace the BICU.
B230/B237 4-24 SM No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures) Line position adjustment (MUSIC) error Line position adjustment fails four consecutive times. ƒ Pattern sampling error ( insufficient image density ) ƒ Defective ID sensors for the line position adjustment ƒ Defective image transfer belt unit ƒ Defective PCU(s) ƒ Defective laser optics housing unit 285 D 1. Do the recovery procedure for SC285 (see Laser Optics Housing Unit in Replacement & Adjustment). 2. Check and reinstall the image transfer belt unit and PCUs. 3. Check if each toner bottle has enough toner. 4. Replace the ID sensor. 5. Replace the image transfer belt unit. 6. Replace the PCU(s). 7. Replace the laser optics housing unit.
SM 4-25 B230/B237 Trouble shooting No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures) Shutter sensor time over error: Close The shutter close sensor does not detect ON for 2000msec after the shutter motor turns on. ƒ Defective shutter close sensor ƒ Disconnected or broken harness ƒ Defective shutter motor ƒ Defective shutter ƒ Shutter motor overload ƒ Defective IOB 290 D 1. Check or replace the harness. 2. Replace the shutter on the laser optics housing unit. 3. Replace the shutter motor. 4. Replace the shutter close sensor. 5. Replace the IOB. No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures) Shutter overrun error 1: Close The shutter close sensor loses the ON signal after the shutter was closed. ƒ Defective motor ƒ Change of load to shutter motor 291 C 1. Replace the shutter on the laser optics housing unit.
B230/B237 4-26 SM No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures) Shutter overrun error 2: Close The shutter close sensor detects ON after SC 291 has occurred. ƒ Defective motor ƒ Change of load to shutter motor 292 D 1. Replace the shutter on the laser optics housing unit.
SM 4-27 B230/B237 Trouble shooting No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures) Shutter sensor time over error: Open The shutter open sensor does not detect ON for 2000msec after the shutter motor turns on. ƒ Defective shutter close sensor ƒ Disconnected or broken harness ƒ Defective shutter motor ƒ Defective shutter ƒ Shutter motor overload ƒ Defective IOB 293 D 1. Check or replace the harness. 2. Replace the shutter on the laser optics housing unit. 3. Replace the shutter motor. 4. Replace the shutter close sensor. 5. Replace the IOB. No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures) Shutter overrun error 1: Open The shutter open sensor loses the ON signal after the shutter was closed. ƒ Defective motor ƒ Change of load to shutter motor 294 C 1. Replace the shutter on the laser optics housing unit.
B230/B237 4-28 SM No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures) Shutter overrun error 2: Open The shutter open sensor detects ON after SC 291 has occurred. ƒ Defective motor ƒ Change of load to shutter motor 295 D 1. Replace the shutter on the laser optics housing unit. No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures) Shutter open/close sensor error Both shutter open sensor and close sensor detect ON at the same time. ƒ Broken harness(es) of the shutter open/close sensors 296 D 1. Replace the shutter on the laser optics housing unit.
SM 4-29 B230/B237 Trouble shooting No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures) 300 D AC charge output error [K] 301 D AC charge output error [M] 302 D AC charge output error [C] 303 D AC charge output error [Y] The measured voltage is not proper when BICU measures the charge output for each color. ƒ Disconnected or broken high voltage cable ƒ Defective or not installed PCU ƒ Defective high voltage power supply 1. Check or replace the connectors. 2. Replace the PCU for black. 3. Replace the high voltage power supply. No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures) Color development motor error The motor LOCK signal is not detected for more than two seconds while the motor START signal is on. ƒ Color development motor slip due to an increase in the torque 325 D 1. Adjust the torque properly by replacing or cleaning the development unit. 2. Replace the color development motor if the load torque is normal.
B230/B237 4-30 SM No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures) 360 D TD sensor (Vt high) error 1: K 361 D TD sensor (Vt high) error 1: M 362 D TD sensor (Vt high) error 1: C 363 D TD sensor (Vt high) error 1: Y ƒ The Vt value of the black, magenta, cyan, or yellow TD sensor exceeds the specified value (default: 4.7V) with SP3020-002 for twenty counts. ƒ The [Vt - Vtref] value of the black, magenta, cyan, or yellow TD sensor exceeds the specified value (default: 5.0V) with SP3020-001. ƒ Black, magenta, cyan, or yellow TD sensor disconnected ƒ Harness between TD sensor and PCU defective ƒ Defective TD sensor. 1. Check the black, magenta, cyan, or yellow TD sensor connector and harness between the TD sensor and PCU for damage. 2. Check the drawer connector. 3. Replace the defective PCU.