Ricoh B230 Service Manual
Have a look at the manual Ricoh B230 Service Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 127 Ricoh manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
SM 5-245 B230/B237 Service Tables firmware update is done with the firmware files from the URL. 086 Firmware Size Allows the service technician to confirm the size of the firmware data files during the firmware update execution. 087 CERT: Macro Version Displays the macro version of the NRS certification. 088 CERT: PAC Version Displays the PAC version of the NRS certification. 089 CERT: ID2 Code Displays ID2 for the NRS certification. Spaces are displayed as underscores (_). Asteriskes () indicate that no NRS certification exists. 090 CERT: Subject Displays the common name of the NRS certification subject. CN = the following 17 bytes. Spaces are displayed as underscores (_). Asterisks () indicate that no DESS exists. 091 CERT: Serial Number Displays serial number for the NRS certification. Asterisks () indicate that no DESS exists. 092 CERT: Issuer Displays the common name of the issuer of the NRS certification. CN = the following 30 bytes. Asteriskes () indicate that no DESS exists. 093 CERT: Valid Start Displays the start time of the period for which the current NRS certification is enabled. 094 CERT: Valid End Displays the end time of the period for which the current NRS certification is enabled. Selection Country 150 Select from the list the name of the country where Cumin-M is installed in the machine. After selecting the country, you must also set the following SP codes for Cumin-M: ƒ SP5816-153 ƒ SP5816-154
B230/B237 5-246 SM ƒ SP5816-161 0: Japan, 1: USA, 2: Canada, 3: UK, 4: Germany, 5: France, 6: Italy, 7: Netherlands, 8: Belgium, 9: Luxembourg, 10: Spain Line Type Authentication Judgment 151 Touch [Execute]. Setting this SP classifies the telephone line where Cumin-M is connected as either dial-up or push type, so Cumin-M can automatically distinguish the number that connects to the outside line. ƒ The current progress, success, or failure of this execution can be displayed with SP5816-152. ƒ If the execution succeeded, SP5816-153 will display the result for confirmation and SP5816-154 will display the telephone number for the connection to the outside line. Line Type Judgment Result 152 Displays a number to show the result of the execution of SP5816 151. Here is a list of what the numbers mean. 0: Success 1: In progress (no result yet). Please wait. 2: Line abnormal 3: Cannot detect dial tone automatically 4: Line is disconnected 5: Insufficient electrical power supply 6: Line classification not supported 7: Error because fax transmission in progress – ioctl() occurred. 8: Other error occurred 9: Line classification still in progress. Please wait. Selection Dial/Push 153 This SP displays the classification (tone or pulse) of the telephone line to the access point for Cumin-M. The numbered displayed (0 or 1) is the result of the execution of SP5816 151. However, this setting can also be changed manually. [0 to 1/ 0 / 1 /step]
SM 5-247 B230/B237 Service Tables 0: Tone Dialing Phone 1: Pulse Dialing Phone Inside Japan 2 may also be displayed: 0: Tone Dialing Phone 1: Pulse Dialing Phone 10PPS 2: Pulse Dialing Phone 20PPS Outside Line/Outgoing Number 154 The SP sets the number that switches to PSTN for the outside connection for Cumin-M in a system that employs a PBX (internal line). ƒ If the execution of SP5816 151 has succeeded and Cumin-M has connected to the external line, this SP display is completely blank. ƒ If Cumin-M has connected to an internal line, then the number of the connection to the external line is displayed. ƒ If Cumin-M has connected to an external line, a comma is displayed with the number. The comma is inserted for a 2 sec. pause. ƒ The number setting for the external line can be entered manually (including commas). Dial Up User Name 156 Use this SP to set a user name for access to remote dial up. Follow these rules when setting a user name: ƒ Name length: Up to 32 characters ƒ Spaces and # allowed but the entire entry must be enclosed by double quotation marks (). Dial Up Password 157 Use this SP to set a password for access to remote dial up. Follow these rules when setting a user name: ƒ Name length: Up to 32 characters ƒ Spaces and # allowed but the entire entry must be enclosed by double quotation marks (). Local Phone Number 161 Use this SP to set the telephone number of the line where Cumin-M is
B230/B237 5-248 SM connected. This number is transmitted to and used by the Call Center to return calls. Limit: 24 numbers (numbers only) Connection Timing Adjustment: Incoming 162 When the Call Center calls out to a Cumin-M modem, it sends a repeating ID tone (*#1#). This SP sets the line remains open to send these ID tones after the number of the Cumin-M modem is dialed up and connected. [0 to 24 / 1 / 1 /step] The actual amount of time is this setting x 2 sec. For example, if you set 2 the line will remain open for 4 sec. Access Point 163 This is the number of the dial-up access point for Cumin-M. If no setting is done for this SP code, then a preset value (determined by the country selected) is used. Default: 0 Allowed: Up to 16 alphanumeric characters 164 Line Connecting This SP sets the connection conditions for the customer. This setting dedicates the line to Cumin-M only, or sets the line for sharing between Cumin-M and a fax unit. [0 to 1 / 0 / 1 /step] 0: Sharing Fax 1: No Sharing Fax ƒ If this setting is changed, the copier must be cycled off and on. ƒ SP5816 187 determines whether the off-hook button can be used to interrupt a Cumin-M transmission in progress to open the line for fax transaction. 173 Modem Serial Number This SP displays the serial number registered for the Cumin-M. 174 Retransmission Limit
SM 5-249 B230/B237 Service Tables Normally, it is best to allow unlimited time for certification and ID2 update requests, and for the notification that the certification has been completed. However, Cumin-M generates charges based on transmission time for the customer, so a limit is placed upon the time allowed for these transactions. If these transactions cannot be completed within the allowed time, do this SP to cancel the time restriction. 175 Modem Modulation Mode Setting FAX TX Priority - 187 This SP determines whether pushing the off-hook button will interrupt a Cumin-M transmission in progress to open the line for fax transaction. This SP can be used only if SP5816 164 is set to 0. [0 or 1/ 0 / - ] 0: Disable, 1: Enable 200 Manual Polling - Executes the manual polling. Regist: Status 201 Displays a number that indicates the status of the NRS service device. 0: Neither the NRS device nor Cumin device are set. 1: The Cumin device is being set. Only Box registration is completed. In this status the Basil unit cannot answer a polling request. 2: The Cumin device is set. In this status the Basil unit cannot answer a polling request. 3: The NRS device is being set. In this status the Cumin device cannot be set. 4: The NRS module has not started. 202 Letter Number Allows entry of the number of the request needed for the Cumin device. 203 Confirm Execute Executes the inquiry request to the NRS GW URL. 204 Confirm Result Displays a number that indicates the result of the inquiry executed with SP5816 203. 0: Succeeded
B230/B237 5-250 SM 1: Inquiry number error 2: Registration in progress 3: Proxy error (proxy enabled) 4: Proxy error (proxy disabled) 5: Proxy error (Illegal user name or password) 6: Communication error 7: Certification update error 8: Other error 9: Inquiry executing Confirm Place 205 Displays the result of the notification sent to the device from the GW URL in answer to the inquiry request. Displayed only when the result is registered at the GW URL. 206 Register Execute Executes Cumin Registration. Register Result 207 Displays a number that indicates the registration result. 0: Succeeded 2: Registration in progress 3: Proxy error (proxy enabled) 4: Proxy error (proxy disabled) 5: Proxy error (Illegal user name or password) 6: Communication error 7: Certification update error 8: Other error 9: Registration executing Error Code Displays a number that describes the error code that was issued when either SP5816-204 or SP5816-207 was executed. Cause Code Meaning 208 Illegal Modem -11001 Chat parameter error
SM 5-251 B230/B237 Service Tables -11002 Chat execution error Parameter -11003 Unexpected error -12002 Inquiry, registration attempted without acquiring device status. -12003 Attempted registration without execution of an inquiry and no previous registration. Operation Error, Incorrect Setting -12004 Attempted setting with illegal entries for certification and ID2. -2385 Attempted dial up overseas without the correct international prefix for the telephone number. -2387 Not supported at the Service Center -2389 Database out of service -2390 Program out of service -2391 Two registrations for same device -2392 Parameter error -2393 Basil not managed -2394 Device not managed -2395 Box ID for Basil is illegal -2396 Device ID for Basil is illegal -2397 Incorrect ID2 format Error Caused by Response from GW URL -2398 Incorrect request number format 209 @Remote Setting Clear Releases the machine from its Cumin setup. 250 CommLog Print Prints the communication log.
B230/B237 5-252 SM 5821 [Remote Service Address] 001 CSS-PI Device Code Sets the PI device code. After you change this setting, you must turn the machine off and on. [0 to 4 / 0 / 1 /step] 002 RCG IP Address *CTL Sets the IP address of the RCG (Remote Communication Gate) destination for call processing at the remote service center. [NV-RAM Data Upload] 5824 Uploads the UP and SP mode data (except for counters and the serial number) from the NVRAM to an SD card. For details, see the NVRAM Data Upload/Download in this section. 5824 1 NV-RAM Data Upload # - [NV-RAM Data Download] 5825 Downloads the UP and SP mode data from an SD card to the NVRAM. For details, see the NVRAM Data Upload/Download in this section. 5825 1 NV-RAM Download # - 5828 [Network Setting] *CTL - 050 1284 Compatibility (Centro) Enables or disables 1284 Compatibility. [0 or 1 / 1 / 1 / step] 0: Disabled, 1: Enabled 052 ECP (Centro) Enables or disables ECP Compatibility. [0 or 1 / 1 / 1 / step] 0: Disabled, 1: Enabled ƒ This SP is activated only when
SM 5-253 B230/B237 Service Tables SP5-828-50 is set to 1. 065 Job Spooling Enables/disables Job Spooling. [0 or 1 / 0 / 1 / step] 0: Disabled, 1: Enabled 066 Job Spooling Clear: Start Ti m e Treatment of the job when a spooled job exists at power on. 0: ON (Data is cleared) 1: OFF (Automatically printed) 069 Job Spooling (Protocol) Validates or invalidates the job spooling function for each protocol. 0: Validates 1: Invalidates bit0: LPR bit1: FTP bit2: IPP bit3: SMB bit4: BMLinkS bit5: DIPRINT bit6: sftp bit7: (Reserved) 090 TELNET (0: OFF 1: ON)Enables or disables the Telnet protocol. [0 or 1 / 1 / – ] 0: Disable, 1: Enable 091 Web (0: OFF 1: ON) Enables or disables the Web operation. [0 or 1 / 1 / – ] 0: Disable, 1: Enable 145 Active IPv6 Link Local Address This is the IPv6 local address link referenced on the Ethernet or wireless LAN (802.11b) in the format: Link Local Address + Prefix Length The IPv6 address consists of a total 128 bits configured in 8 blocks of 16 bits each.
B230/B237 5-254 SM 147 Active IPv6 Stateless Address 1 149 Active IPv6 Stateless Address 2 151 Active IPv6 Stateless Address 3 153 Active IPv6 Stateless Address 4 155 Active IPv6 Stateless Address 5 These SPs are the IPv6 status addresses (1 to 5) referenced on the Ethernet or wireless LAN (802.11b) in the format: Status Address + Prefix Length The IPv6 address consists of a total 128 bits configured in 8 blocks of 16 bits each. 156 IPv6 Manual Address This SP is the IPv6 manually set address referenced on the Ethernet or wireless LAN (802.11b) in the format: Manual Set Address + Prefix Length The IPv6 address consists of a total 128 bits configured in 8 blocks of 16 bits each. 158 IPv6 Gateway Address This SP is the IPv6 gateway address referenced on the Ethernet or wireless LAN (802.11b). The IPv6 address consists of a total 128 bits configured in 8 blocks of 16 bits each. 5832 [HDD] HDD Initialization *CTL - 001 HDD Formatting (ALL) 002 HDD Formatting (IMH) 003 HDD Formatting (Thumbnail) 004 HDD Formatting (Job Log) 005 HDD Formatting (Printer Initializes the hard disk. Use this SP mode only if there is a hard disk error.