    							6. Specifications
    and Parts
    6-3
    SPECIFICATIONS
    Electrical Specifications
    Power Supply: 120 VAC ±- 10% @ 50-60 Hz
    4-Slot Output Power 91 Watts @ 100% full load
    4-Slot Input Current 1.50A @ 110 V
    4-Slot VA 165
    4-Slot Kwh .165
    4-Slot BTU 563
    Grounding Requirements: 12 AWG copper wire
    Environmental Specifications
    Cabinets and Key Telephones
    Temperature: 0-45
    oC (32-113
    oF)
    Humidity: 10-95% (non-condensing)
    Door Box
    Temperature: -20-60
    oC (-4-140
    oF)
    Humidity: 10-95% (non-condensing)
    Power Requirements
    A dedicated 110 VAC 60 Hz circuit located within seven feet
    of the cabinet is required. You should install a separate dedi-
    cated outlet for each cabinet.
    Environmental Requirements
    Meeting established environmental standards maximizes the
    life of the system. Refer to the Standard Practices Manual for
    further information. Be sure that the site is not:
    1. In direct sunlight or in hot, cold or humid places.
    2. In dusty areas or in areas where sulfuric gases are produced.
    3. In places where shocks or vibrations are frequent or strong.
    4. In places where water or other fluids comes in contact with
    the main equipment.
    5. In areas near high-frequency machines or electric welders.
    6. Near computers, telexes, microwaves, air conditioners, etc.
    7. Near radio antennas (including shortwave). 
    						
    							6-4
    SPECIFICATIONS
    ACI Module Input/Output
    Audio/Music Input
    Input Impedance: 47 KOhm @ 1Khz
    Audio/Paging Output
    Output Impedance: 600 Ohms @ 1 KHz
    Maximum Output: +3 dBm
    Relay Contacts
    Configuration: Normally Open
    Maximum Contact Ratings: 30 VDC @ 60 mA
    90 VAC @ 10 mA
    Minimum Application Load: 1 VDC @ 1 mA
    External Paging
    Output Impedance: 600 Ohm
    Output Level: 0 dBr at 1.0 KHz
    External Paging Contacts
    Output Impedance: 600 Ohm
    Output Level: Nominal 250 mV (-10 dBm)
    Maximum Output: 400 mV RMS
    Configuration: Normally open
    Mechanical Specifications
    Equipment Width Depth Height Weight
    4-Slot KSU 10 3/4””5 7/8””13 11/16”4 lbs 5 oz
    Non-display Keyset 7 1/4”9”2 7/8””1 lb 11 oz
    Display Keyset 7 1/4”9”2 7/8”1 lb 12 oz
    Super Display Keyset 7 1/4”9”2 7/8”1 lb 16 oz
    DSS Console 7 7/8” 8 7/8” 2 3/4” 1 lb 6 oz
    Door Box 4” 1 1/2” 5 3/16” 10 oz
    2-OPX Module 9 3/8” 7 3/8” 1 1/4” 3 lbs 
    						
    							6. Specifications
    and Parts
    6-5
    SPECIFICATIONS
    Cabling Requirements
    1. Do not run station cable parallel with the AC source, telex or com-
    puter, etc. If the cables are near cable runs to those devices, use
    shielded cable with grounded shields or install the cable in conduit.
    2. When cables must be run on the floor, use cable protectors.
    3. Cable runs for key telephones, single line telephones, Door Boxes
    and 3-ACI Modules must be a dedicated, isolated cable pair.Device Cable Type Cable Run Length (ft) Notes
    Key Telephone, 2-wire 26 AWG 1300
    2-wire 24 AWG 2000
    3-ACI Module & 2-wire 24 AWG 2000
    3-DCI Module 2-wire 22 AWG 2000
    Single Line 2-wire 26 AWG TBD at constant 20 mA
    Telephone TBD at constant 35 mA
    2-wire 24 AWG TBD at constant 20 mA
    TBD at constant 35 mA
    2-wire 22 AWG TBD at constant 20 mA
    TBD at constant 35 mA
    Door Box 2-wire 24 AWG 2000
    2-wire 22 AWG 2000
    2-OPX 2-wire 24 AWG 1000
    FCC Registration Information
    Model: DS2000
    Manufacturer: Nitsuko
    FCC Part 15 Registration: Class A
    FCC Registration Number: 1ZDTHA27007-KF-E
    1ZDTHA27044-MF-E
    Industry Canada
    Certificate (DOC) Number 854 9522 AReg. FIC Mfrs. Port Ringer Network
    Status Identifier Eq. Number JacksOriginal 02LS2 80010 0.6B RJ11C
    80011 RJ21X
    BGM/MOH Music Source Input
    Input Impedance: 10K Ohms
    Input Level: +18 dBr (+/- 2 dBr) t 1.0
    KHz
    Music input is located on the CPU PCB. 
    						
    							6-6
    PARTS LIST
    Common Equipment
    Description Part Number
    4-Slot KSU 80000
    DS2000 Power Supply 80005
    Installation Cable 80892
    Blank PC Card 85880
    PC Card with system software preloaded 80050-V**.**
    (**.** denotes the system software level)
    8-Pin DIN to Mod-8 Cable 80893
    DB9 to Mod-8 Adaptor 85980
    DB25 to Mod-8 Adaptor 85981
    Spare KSU Hanger 80578
    Peripheral Station Equipment
    Description Part Number
    2-OPX Module 92177A
    Station Equipment
    Description Part Number
    34-Button Super Display Telephone 80673
    34-Button Display Telephone 80663
    22-Button Telephone 80570
    22-Button Display Telephone 80573
    24-Button DSS Console 80556
    110-Button DSS Console 80555
    Wall Mount Kit TBD
    Analog Telephones (customer provided) 
    						
    							6. Specifications
    and Parts
    6-7
    PARTS LIST
    Replacement Parts
    Description Part Number
    Handset and Cord Assembly TBD
    Handset Coil Cord - Black 6’ TBD
    Handset Coil Cord - Black 9’ TBD
    Handset Coil Cord - Black 13’ TBD
    22 Btn Tel Plastic C.O. Cover TBD
    34 Btn Tel Plastic C.O. Cover TBD
    22 Btn Designation Strip TBD
    34 Btn Designation Strip TBD
    24-Button DSS Console Designation Strip TBD
    110-Button DSS Console Designation Strip TBD
    PCBs
    Description Part Number
    CPU Central Processing Unit 80025
    16DSTU Digital Station PCB 80021
    8ASTU 8 Port Analog Station PCB 80041
    4ASTU 4 Port Analog Station PCB 80040
    4ATRU 4 Port Analog Trunk PCB (loop start) 80010
    8ATRU 8 Port Analog Trunk PCB (loop start) 80011 
    						
    							Nitsuko America, Telecom Division
    4 Forest Parkway
    Shelton, CT  06484
    TEL: 203-926-5400
    FAX: 203-929-0535
    Other Important Telephone Numbers
    Sales:  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .203-926-5450
    Customer Service:  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .203-926-5444
    Customer Service FAX:  . . . . . . . . . . . . . . . . . . . . . . . . . .203-926-5454
    Technical Service:  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .203-925-8801
    Discontinued Product Service:  . . . . . . . . . . . . . . . . . . . . .900-990-2541
    Technical Training: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .203-926-5430
    Emergency Technical Service (After hours)  . . . . . . . . . . .203-929-7920
    (Excludes discontinued products)
    Nitsuko Canada, Division of Nitsuko America
    165 Matheson Blvd. E., Unit #4-6
    Mississauga, Ontario Canada L4Z 3K2
    TEL
    : 905-507-2888, 
    FA X
    : 905-507-2971Th
    6-9
    co 
    						
    							4 Forest Parkway
    Shelton, CT 06484
    TEL:
    203-926-5400  
    FAX:
    203-929-0535165 Matheson Blvd. E., Unit #4-6,
    Mississauga, Ontario Canada L4Z 3K2
    TEL:
    905-507-2888  
    FAX:
    905-507-2971 
    						
    All Nitsuko manuals Comments (0)

    Related Manuals for Nitsuko Ds2000 Software Manual