0500 - System Numbering 0510 - ACD/UCD Master Extension Numbers and Names DS2000 Software Manual Chapter 2: Programming403 2. 0510 + HOLD 3. Enter the number of the group you want to program (1-8) + HOLD. The previously programmed extension number displays. 4. Enter the number of the extension you want assigned to the group. OR Press HOLD to leave the entry unchanged. The previously programmed name displays. 5. Enter the name for the group (10 character maximum) + HOLD OR Press HOLD to leave the displayed name unchanged. 6. Return to step 3 and enter another group. OR Press HOLD to return to step 2 and enter another program 0510:ACD ID GROUP NUM? 0510:ACD ID-GROUP:nn EXT NUM?nnn 0510:ACD ID-GROUP:nn NAME?(name) 0510:ACD ID GROUP NUM?
0500 - System Numbering 0511 - Ring Group Master Extension Numbers and Names 404Chapter 2: ProgrammingDS2000 Software Manual 0511 - Ring Group Master Extension Numbers and Names Description Use Program 0511- Ring Group Master Extension Numbers and Names to assign extension numbers and names to the Ring Group master extensions. The system can have up to eight Ring Groups (1-8). The extension numbers you enter must be unique and not overlap extension numbers used for trunks, extensions, ACI ports, DCI ports or Extension Hunting master numbers. Conditions NoneLCCPU 01.00.00 Available. Table 29: Program 0511 - Ring Group Master Extension Numbers and Names OptionDescriptionEntriesDefault Extension Number Use this option to enter the extension num- ber associated with the Ring Group selected. • See Central Office Calls, Answering on page 58 for more. • See Flexible Numbering Plan on page 134 for more. • See Ring Groups on page 248 for more.EXT NUM?Ring Group master num- bers can be 100-299, 332- 400, or 417-899. They cannot be in the exten- sion (300-331) or trunk (401-416) number range. By default, the systems uses codes beginning with 0 for operator access and 9 for trunk/trunk group access.Not assigned NameUse this option to enter the name associated with the Ring Group selected. • See Central Office Calls, Answering on page 58 for more. • See Ring Groups on page 248 for more. • When entering names, use Table 17: Keys for Entering Names on page 361.NAME?Not assigned
0500 - System Numbering 0511 - Ring Group Master Extension Numbers and Names DS2000 Software Manual Chapter 2: Programming405 Telephone Programming Instructions 1. Enter the programming mode. 2. 0511 + HOLD 3. Enter the number of the group you want to program (1-8) + HOLD. The previously programmed extension number displays. 4. Enter the number of the extension you want assigned to the group. OR Press HOLD to leave the entry unchanged. The previously programmed name displays. 5. Enter the name for the group (10 character maximum) + HOLD OR Press HOLD to leave the displayed name unchanged. 6. Return to step 3 and enter another group. OR Press HOLD to return to step 2 and enter another program 0511:RING GROUP ID GROUP NUM? 0511:RING GROUP:nn EXT NUM?nnn 0511:RING GROUP:nn NAME?(name) 0511:RING GROUP ID GROUP NUM?
0600 - Toll Restriction 0601 - Toll Restriction Options 406Chapter 2: ProgrammingDS2000 Software Manual 0600 - Toll Restriction 0601 - Toll Restriction Options Description Use Program 0601- Toll Restriction Options to assign Toll Restriction options to each of the seven Toll Levels (1-7). When you assign a Toll Level to an extension, the extension uses the options set up in this program. Conditions NoneLCCPU 01.00.00 Not available. Table 30: Program 0601 - Toll Restriction Options OptionDescriptionEntriesDefault Program Toll Restriction Use this option to program Toll Restriction. (You must always use the following option to initialize Toll Restriction before using it for the first time.) • See Toll Restriction on page 314 for more.PROG-PP = ProgramN/A Initialize Toll RestrictionUse this option to initialize Toll Restriction. You must always initialize Toll Restriction before using if for the first time. If you have already programmed Toll Restriction, initial- izing will erase all your entries and reinstate the default Toll Restriction values. • See Toll Restriction on page 314 for more.INIT-II = InitializeN/A Toll Restriction LevelUse this option to select the Toll Restriction level you want to program. The entries that follow pertain to the Toll Restriction Level you select in this step. • See Toll Restriction on page 314 for more.TOLL LEVEL1-71 Active Dial PadUse this option to enable or disable Active Dial Pad (continuous dialing) for trunk calls. • See Toll Restriction on page 314 for more.ACTIVE DIAL PAD?Y = Enable N = DisableY N11 DialingUse this option to enable or disable dial N11 services such as directory assistance (411) and repair (611). This option does not restrict 911 or 1 + 911 calls. These calls are always allowed. • See Toll Restriction on page 314 for more.N11 DIALING?Y = Enable N = DisableY
0600 - Toll Restriction 0601 - Toll Restriction Options DS2000 Software Manual Chapter 2: Programming407 0 + DialingUse this option to enable or disable an exten- sion’s ability to manually dial 0 + (operator assisted) calls. • See Toll Restriction on page 314 for more.0 + DIALING?Y = Enable N = DisableY International DialingUse this option to enable or disable 011 (international) dialing. • See Toll Restriction on page 314 for more.INT’L DIAL?Y = Enable N = DisableY Equal Access DialingThis option allows/prevents an extension user from directly dialing Equal Access (10XXX) calls. The system compares the 10XXX codes the user dials to the 10XXX table that you program. • See Toll Restriction on page 314 for more. • See Toll Restriction Rules on page 317 for more.10+XXX DIALING ALLOW OR DENY TABLE? A = Allow Table D = Deny TableA (Allow table) • Enter A to set the table up as an allow table, or D to set the table up as a deny table. • D to convert an existing allow table into a deny table, or enter A to convert an existing deny table into an allow table. ADD-A/VIEW-V/DEL-DA = Add a code to the table D = Delete a code from the table V = View the table entriesN/A NXX DialingThis option allows/prevents an extension user from directly dialing NXX (local exchange) calls. The system compares the NXX codes the user dials to the NXX table that you program. • See Toll Restriction on page 314 for more. • See Toll Restriction Rules on page 317 for more.NXX DIALING ALLOW OR DENY TABLE? A = Allow Table D = Deny TableA (Allow table) • Enter A to set the table up as an allow table, or D to set the table up as a deny table. • D to convert an existing allow table into a deny table, or enter A to convert an existing deny table into an allow table. ADD-A/VIEW-V/DEL-DA = Add a code to the table D = Delete a code from the table V = View the table entriesN/A Table 30: Program 0601 - Toll Restriction Options OptionDescriptionEntriesDefault
0600 - Toll Restriction 0601 - Toll Restriction Options 408Chapter 2: ProgrammingDS2000 Software Manual NPA DialingThis option allows/prevents an extension user from directly dialing NPA (area code) calls. The system compares the NPA codes the user dials to the NPA table that you pro- gram. • See Toll Restriction on page 314 for more. • See Toll Restriction Rules on page 317 for more.NPA DIALING ALLOW OR DENY TABLE? A = Allow Table D = Deny TableA (Allow table) • Enter A to set the table up as an allow table, or D to set the table up as a deny table. • D to convert an existing allow table into a deny table, or enter A to convert an existing deny table into an allow table. ADD-A/VIEW-V/DEL-DA = Add a code to the table D = Delete a code from the table V = View the table entriesN/A 6-Digit AnalysisThis option enables/disables 6-Digit Analy- sis. With 6-Digit Analysis, the system restricts a call according the NPA and NXX the user dials. The system compares the codes the user dials to the 6-Digital Analysis table that you program. • See Toll Restriction on page 314 for more. • See Toll Restriction Rules on page 317 for more.6 DGT ANALYSIS ALLOW OR DENY TABLE? A = Allow Table D = Deny TableA (Allow table) • Enter A to set the table up as an allow table, or D to set the table up as a deny table. • D to convert an existing allow table into a deny table, or enter A to convert an existing deny table into an allow table. ADD-A/VIEW-V/DEL-DA = Add a code to the table D = Delete a code from the table V = View the table entriesN/A Table 30: Program 0601 - Toll Restriction Options OptionDescriptionEntriesDefault
0600 - Toll Restriction 0601 - Toll Restriction Options DS2000 Software Manual Chapter 2: Programming409 Telephone Programming Instructions To quickly locate the procedure for a Toll Restriction option, go to the steps listed below: To select the Toll Level you want to program, go to step 4. To enable or disable Active Dial Pad, go to step 5. If setting up N11 Dialing, go to step 6. When enabling or disabling 0+ Dialing, go to step 7. For International Dialing options, go to step 8. When programming Equal Access (10XXX) Dialing, go to step 9. If you want to configure NXX Dialing, go to step 12. To select the NPA Dialing options, go to step 15. To set up 6-Digit Analysis, go to 18. 1. Enter the programming mode. 2. 0601 + HOLD. 3. Enter P (7) to program Toll Restriction and go to the next step. OR Enter I (4) + HOLD to initialize Toll Restriction and return to the previous step. You must always initialize Toll Restriction when programming it for the first time. If you initialize an existing Toll Restriction setup, you’ll return all your programmed entries to their factory-installed initial values. Toll Level 4. Enter the Toll Level you want to program (1-7) + HOLD OR Press HOLD to select the currently displayed Toll Level. The options that follow pertain to the Toll Level selected. Active Dial Pad 5. Enter Y to enable or N to disable Active Dial Pad + VO L . OR Press VO L to select the currently displayed value. The previously programmed value displays. N11 Dialing 6. Enter Y to enable or N to disable N11 Dialing + VO L . 0601:TOLL RESTRICT PROG-P / INIT-I? 0601:TOLL RESTRICT TOLL LEVEL?1 0601:TOLL RESTRICT TABLES INITIALIZED! 0601:TOLL LEVEL:n ACTIVE DIAL PAD?n 0601:TOLL LEVEL:n N11 DIALING?nnn
0600 - Toll Restriction 0601 - Toll Restriction Options 410Chapter 2: ProgrammingDS2000 Software Manual OR Press VO L to select the currently displayed value. The previously programmed value displays 0+ Dialing 7. Enter Y to enable or N to disable 0+ Dialing + VO L . OR Press VO L to select the currently displayed value. The previously programmed value displays International Dialing 8. Enter Y to enable or N to disable International Dialing + VO L . OR Press VO L to select the currently displayed value. The previously programmed table type displays (A = allow, D = deny). Equal Access (10XXX) Dialing 9. Enter A to set up the table as an allow table. OR Enter D to set up the table as a deny table. OR Enter D to convert an existing allow table into a deny table, or enter A to convert an existing deny table into an allow table. 10. Press A to add codes into the table. OR Press D to delete codes from the table. OR Press V to view the current contents of the table. If you press V to view the table, the bottom line of the display will show the first set of table entries. Press V to see the remaining entries. The prompt TABLE DONE tells you when you are at the end of the table or the table is empty. The prompt > tells you that there is additional data in the table to view. If you press A or D to add codes into the table, you see the prompt DATA. Just enter the codes you want into the table. When entering data, new data appears to the right of the previously entered data. (The system automatically assumes that every group of three dig- its is an entry.) 11. When you are done entering data, press VO L to go to the next option. 0601:TOLL LEVEL:n 0 + DIALING?nnn 0601:TOLL LEVEL:n INT’L DIAL?nnn 0601:10+XXX DIALING ALLOW OR DENY TABLE? 0601:10+XXX ALLW TBL ADD-A/VIEW-V/DEL-D? 0601:10+XXX DENY TBL ADD-A/VIEW-V/DEL-D? 0601:NXX DIALING ALLOW OR DENY TABLE?
0600 - Toll Restriction 0601 - Toll Restriction Options DS2000 Software Manual Chapter 2: Programming411 The previously programmed table type displays (A = allow, D = deny). NXX Dialing 12. Enter A to set up the table as an allow table. OR Enter D to set up the table as a deny table. OR Enter D to convert an existing allow table into a deny table, or enter A to convert an existing deny table into an allow table. 13. Press A to add codes into the table. OR Press D to delete codes from the table. OR Press V to view the current contents of the table. If you press V to view the table, the bottom line of the display will show the first set of table entries. Press V to see the remaining entries. The prompt TABLE DONE tells you when you are at the end of the table or the table is empty. The prompt > tells you that there is additional data in the table to view. If you press A or D to add codes into the table, you see the prompt DATA. Just enter the codes you want into the table. When entering data, new data appears to the right of the previously entered data. (The system automatically assumes that every group of three dig- its is an entry.) 14. When you are done entering data, press VO L to go to the next option. The previously programmed table type displays (A = allow, D = deny). NPA Dialing 15. Enter A to set up the table as an allow table. OR Enter D to set up the table as a deny table. OR Enter D to convert an existing allow table into a deny table, or enter A to convert an existing deny table into an allow table. 16. Press A to add codes into the table. OR Press D to delete codes from the table. OR Press V to view the current contents of the table. If you press V to view the table, the bottom line of the display will show the first set of table entries. Press V to see the remaining entries. The prompt TABLE DONE tells you when you are at the end of the table or the table is empty. The prompt > tells you that there 0601:NXX ALLOW TABLE ADD-A/VIEW-V/DEL-D? 0601:NXX DENY TABLE ADD-A/VIEW-V/DEL-D? 0601:NPA DIALING ALLOW OR DENY TABLE? 0601:NPA ALLOW TABLE ADD-A/VIEW-V/DEL-D? 0601:NPA DENY TABLE ADD-A/VIEW-V/DEL-D?
0600 - Toll Restriction 0601 - Toll Restriction Options 412Chapter 2: ProgrammingDS2000 Software Manual is additional data in the table to view. If you press A or D to add codes into the table, you see the prompt DATA. Just enter the codes you want into the table. When entering data, new data appears to the right of the previously entered data. (The system automatically assumes that every group of three dig- its is an entry.) 17. When you are done entering data, press VO L to go to the next option. The previously programmed table type displays (A = allow, D = deny). 6-Digit Analysis 18. Enter A to set up the table as an allow table. OR Enter D to set up the table as a deny table. OR Enter D to convert an existing allow table into a deny table, or enter A to convert an existing deny table into an allow table. 19. Press A to add codes into the table. OR Press D to delete codes from the table. OR Press V to view the current contents of the table. If you press V to view the table, the bottom line of the display will show the first set of table entries. Press V to see the remaining entries. The prompt TABLE DONE tells you when you are at the end of the table or the table is empty. The prompt > tells you that there is additional data in the table to view. If you press A or D to add codes into the table, you see the prompt DATA. Just enter the codes you want into the table. When entering data, new data appears to the right of the previously entered data. (The system automatically assumes that every group of six digits is an entry.) 20. When you are done entering data, press VO L to go back to the Active Dial Pad option for the currently selected Toll Level. OR Press CONF to go back to the Program/Initialize option. OR Press CONF twice to exit Toll Restriction programming. 0601:6 DGT ANALYSIS ALLOW OR DENY TABLE? 0601:6 DGT ALLOW TBL ADD-A/VIEW-V/DEL-D? 0601:6 DGT ALLOW TBL ADD-A/VIEW-V/DEL-D? 0601:TOLL LEVEL:n ACTIVE DIAL PAD?nn 0601:TOLL RESTRICT PROG-P / INIT-I