    							0500 - System Numbering
    0510 - ACD/UCD Master Extension Numbers and Names
    DS2000 Software Manual Chapter 2: Programming403
    2. 0510 + HOLD
    3. Enter the number of the group you want to program (1-8) + HOLD.
    The previously programmed extension number displays.
    4. Enter the number of the extension you want assigned to the group.
    OR
    Press 
    HOLD to leave the entry unchanged.
    The previously programmed name displays.
    5. Enter the name for the group (10 character maximum) + 
    HOLD
    OR
    Press 
    HOLD to leave the displayed name unchanged.
    6. Return to step 3 and enter another group.
    OR
    Press 
    HOLD to return to step 2 and enter another program
    0510:ACD ID
    GROUP NUM?
    0510:ACD ID-GROUP:nn
    EXT NUM?nnn
    0510:ACD ID-GROUP:nn
    NAME?(name)
    0510:ACD ID
    GROUP NUM? 
    						
    							0500 - System Numbering
    0511 - Ring Group Master Extension Numbers and Names
    404Chapter 2: ProgrammingDS2000 Software Manual
    0511 - Ring Group Master Extension Numbers and Names
    Description
    Use Program 0511- Ring Group Master Extension Numbers and Names to assign extension 
    numbers and names to the Ring Group master extensions. The system can have up to eight Ring 
    Groups (1-8). The extension numbers you enter must be unique and not overlap extension numbers 
    used for trunks, extensions, ACI ports, DCI ports or Extension Hunting master numbers. 
    Conditions
    NoneLCCPU 01.00.00 Available.
    Table 29:  Program 0511 - Ring Group Master Extension Numbers and Names
    OptionDescriptionEntriesDefault
    Extension Number
    Use this option to enter the extension num-
    ber associated with the Ring Group selected.
    • See Central Office Calls, Answering on 
    page 58 for more.
    • See Flexible Numbering Plan on 
    page 134 for more.
    • See Ring Groups on page 248 for more.EXT NUM?Ring Group master num-
    bers can be 100-299, 332-
    400, or 417-899. They 
    cannot be in the exten-
    sion (300-331) or trunk 
    (401-416) number range. 
    By default, the systems 
    uses codes beginning 
    with 0 for operator access 
    and 9 for trunk/trunk 
    group access.Not assigned
    NameUse this option to enter the name associated 
    with the Ring Group selected.
    • See Central Office Calls, Answering on 
    page 58 for more.
    • See Ring Groups on page 248 for more.
    • When entering names, use Table 17: 
    Keys for Entering Names on page 361.NAME?Not assigned 
    						
    							0500 - System Numbering
    0511 - Ring Group Master Extension Numbers and Names
    DS2000 Software Manual Chapter 2: Programming405
    Telephone Programming Instructions
    1. Enter the programming mode.
    2. 0511 + 
    HOLD
    3. Enter the number of the group you want to program (1-8) + HOLD.
    The previously programmed extension number displays.
    4. Enter the number of the extension you want assigned to the group.
    OR
    Press 
    HOLD to leave the entry unchanged.
    The previously programmed name displays.
    5. Enter the name for the group (10 character maximum) + 
    HOLD
    OR
    Press 
    HOLD to leave the displayed name unchanged.
    6. Return to step 3 and enter another group.
    OR
    Press 
    HOLD to return to step 2 and enter another program
    0511:RING GROUP ID
    GROUP NUM?
    0511:RING GROUP:nn
    EXT NUM?nnn
    0511:RING GROUP:nn
    NAME?(name)
    0511:RING GROUP ID
    GROUP NUM? 
    						
    							0600 - Toll Restriction
    0601 - Toll Restriction Options
    406Chapter 2: ProgrammingDS2000 Software Manual
    0600 - Toll Restriction
    0601 - Toll Restriction Options
    Description
    Use Program 0601- Toll Restriction Options to assign Toll Restriction options to each of the 
    seven Toll Levels (1-7). When you assign a Toll Level to an extension, the extension uses the 
    options set up in this program. 
    Conditions
    NoneLCCPU 01.00.00 Not available.
    Table 30:  Program 0601 - Toll Restriction Options
    OptionDescriptionEntriesDefault
    Program Toll  Restriction
    Use this option to program Toll Restriction. 
    (You must always use the following option 
    to initialize Toll Restriction before using it 
    for the first time.)
    • See Toll Restriction on page 314 for 
    more.PROG-PP = ProgramN/A
    Initialize Toll  RestrictionUse this option to initialize Toll Restriction. 
    You must always initialize Toll Restriction 
    before using if for the first time. If you have 
    already programmed Toll Restriction, initial-
    izing will erase all your entries and reinstate 
    the default Toll Restriction values.
    • See Toll Restriction on page 314 for 
    more.INIT-II = InitializeN/A
    Toll Restriction LevelUse this option to select the Toll Restriction 
    level you want to program. The entries that 
    follow pertain to the Toll Restriction Level 
    you select in this step.
    • See Toll Restriction on page 314 for 
    more.TOLL LEVEL1-71
    Active Dial PadUse this option to enable or disable Active 
    Dial Pad (continuous dialing) for trunk calls.
    • See Toll Restriction on page 314 for 
    more.ACTIVE DIAL PAD?Y = Enable
    N = DisableY
    N11 DialingUse this option to enable or disable dial N11 
    services such as directory assistance (411) 
    and repair (611). This option does not 
    restrict 911 or 1 + 911 calls. These calls are 
    always allowed.
    • See Toll Restriction on page 314 for 
    more.N11 DIALING?Y = Enable
    N = DisableY 
    						
    							0600 - Toll Restriction
    0601 - Toll Restriction Options
    DS2000 Software Manual Chapter 2: Programming407
    0 + DialingUse this option to enable or disable an exten-
    sion’s ability to manually dial 0 + (operator 
    assisted) calls.
    • See Toll Restriction on page 314 for 
    more.0 + DIALING?Y = Enable
    N = DisableY
    International DialingUse this option to enable or disable 011 
    (international) dialing.
    • See Toll Restriction on page 314 for 
    more.INT’L DIAL?Y = Enable
    N = DisableY
    Equal Access DialingThis option allows/prevents an extension 
    user from directly dialing Equal Access 
    (10XXX) calls. The system compares the 
    10XXX codes the user dials to the 10XXX 
    table that you program.
    • See Toll Restriction on page 314 for 
    more.
    • See Toll Restriction Rules on page 317 
    for more.10+XXX DIALING
    ALLOW OR DENY 
    TABLE?
    A = Allow Table
    D = Deny TableA
    (Allow table)
    • Enter A to set the table up as an allow 
    table, or D to set the table up as a deny 
    table.
    • D to convert an existing allow table into 
    a deny table, or enter A to convert an 
    existing deny table into an allow table.
    ADD-A/VIEW-V/DEL-DA = Add a code to the 
    table
    D = Delete a code from 
    the table
    V = View the table entriesN/A
    NXX DialingThis option allows/prevents an extension 
    user from directly dialing NXX (local 
    exchange) calls. The system compares the 
    NXX codes the user dials to the NXX table 
    that you program.
    • See Toll Restriction on page 314 for 
    more.
    • See Toll Restriction Rules on page 317 
    for more.NXX DIALING
    ALLOW OR DENY 
    TABLE?
    A = Allow Table
    D = Deny TableA
    (Allow table)
    • Enter A to set the table up as an allow 
    table, or D to set the table up as a deny 
    table.
    • D to convert an existing allow table into 
    a deny table, or enter A to convert an 
    existing deny table into an allow table.
    ADD-A/VIEW-V/DEL-DA = Add a code to the 
    table
    D = Delete a code from 
    the table
    V = View the table entriesN/A Table 30:  Program 0601 - Toll Restriction Options
    OptionDescriptionEntriesDefault 
    						
    							0600 - Toll Restriction
    0601 - Toll Restriction Options
    408Chapter 2: ProgrammingDS2000 Software Manual
    NPA DialingThis option allows/prevents an extension 
    user from directly dialing NPA (area code) 
    calls. The system compares the NPA codes 
    the user dials to the NPA table that you pro-
    gram.
    • See Toll Restriction on page 314 for 
    more.
    • See Toll Restriction Rules on page 317 
    for more.NPA DIALING
    ALLOW OR DENY 
    TABLE?
    A = Allow Table
    D = Deny TableA
    (Allow table)
    • Enter A to set the table up as an allow 
    table, or D to set the table up as a deny 
    table.
    • D to convert an existing allow table into 
    a deny table, or enter A to convert an 
    existing deny table into an allow table.
    ADD-A/VIEW-V/DEL-DA = Add a code to the 
    table
    D = Delete a code from 
    the table
    V = View the table entriesN/A
    6-Digit AnalysisThis option enables/disables 6-Digit Analy-
    sis. With 6-Digit Analysis, the system 
    restricts a call according the NPA and NXX 
    the user dials. The system compares the 
    codes the user dials to the 6-Digital Analysis 
    table that you program.
    • See Toll Restriction on page 314 for 
    more.
    • See Toll Restriction Rules on page 317 
    for more.6 DGT ANALYSIS
    ALLOW OR DENY 
    TABLE?
    A = Allow Table
    D = Deny TableA
    (Allow table)
    • Enter A to set the table up as an allow 
    table, or D to set the table up as a deny 
    table.
    • D to convert an existing allow table into 
    a deny table, or enter A to convert an 
    existing deny table into an allow table.
    ADD-A/VIEW-V/DEL-DA = Add a code to the 
    table
    D = Delete a code from 
    the table
    V = View the table entriesN/A Table 30:  Program 0601 - Toll Restriction Options
    OptionDescriptionEntriesDefault 
    						
    							0600 - Toll Restriction
    0601 - Toll Restriction Options
    DS2000 Software Manual Chapter 2: Programming409
    Telephone Programming Instructions
    To quickly locate the procedure for a Toll Restriction option, go to the steps listed below:
    To select the Toll Level you want to program, go to step 4.
    To enable or disable Active Dial Pad, go to step 5.
    If setting up N11 Dialing, go to step 6.
    When enabling or disabling 0+ Dialing, go to step 7.
    For International Dialing options, go to step 8.
    When programming Equal Access (10XXX) Dialing, go to step 9.
    If you want to configure NXX Dialing, go to step 12.
    To select the NPA Dialing options, go to step 15.
    To set up 6-Digit Analysis, go to 18.
    1. Enter the programming mode.
    2. 0601 + 
    HOLD.
    3. Enter P (7) to program Toll Restriction and go to the next step.
    OR
    Enter I (4) + 
    HOLD to initialize Toll Restriction and return to the previous step.
    You must always initialize Toll Restriction when programming it for the first time. If 
    you initialize an existing Toll Restriction setup, you’ll return all your programmed entries 
    to their factory-installed initial values.
    Toll Level
    4. Enter the Toll Level you want to program (1-7) + 
    HOLD
    OR
    Press 
    HOLD to select the currently displayed Toll Level.
    The options that follow pertain to the Toll Level selected.
    Active Dial Pad
    5. Enter Y to enable or N to disable Active Dial Pad + 
    VO L .
    OR
    Press 
    VO L  to select the currently displayed value.
    The previously programmed value displays.
    N11 Dialing
    6. Enter Y to enable or N to disable N11 Dialing + 
    VO L .
    0601:TOLL RESTRICT
    PROG-P / INIT-I?
    0601:TOLL RESTRICT
    TOLL LEVEL?1
    0601:TOLL RESTRICT
    TABLES INITIALIZED!
    0601:TOLL LEVEL:n
    ACTIVE DIAL PAD?n
    0601:TOLL LEVEL:n
    N11 DIALING?nnn 
    						
    							0600 - Toll Restriction
    0601 - Toll Restriction Options
    410Chapter 2: ProgrammingDS2000 Software Manual
    OR
    Press 
    VO L  to select the currently displayed value.
    The previously programmed value displays
    0+ Dialing
    7. Enter Y to enable or N to disable 0+ Dialing + 
    VO L .
    OR
    Press 
    VO L  to select the currently displayed value.
    The previously programmed value displays
    International Dialing
    8. Enter Y to enable or N to disable International Dialing + 
    VO L .
    OR
    Press 
    VO L  to select the currently displayed value.
    The previously programmed table type displays (A = allow, D = deny).
    Equal Access (10XXX) Dialing
    9. Enter A to set up the table as an allow table.
    OR
    Enter D to set up the table as a deny table.
    OR
    Enter D to convert an existing allow table into a deny table, or enter A to convert an 
    existing deny table into an allow table.
    10. Press A to add codes into the table.
    OR
    Press D to delete codes from the table.
    OR
    Press V to view the current contents of the table.
    If you press V to view the table, the bottom line of the display will show the first set of 
    table entries. Press V to see the remaining entries. The prompt 
    TABLE DONE tells you 
    when you are at the end of the table or the table is empty. The prompt 
    > tells you that there 
    is additional data in the table to view.
    If you press A or D to add codes into the table, you see the prompt 
    DATA. Just enter the 
    codes you want into the table. When entering data, new data appears to the right of the 
    previously entered data. (The system automatically assumes that every group of three dig-
    its is an entry.) 
    11. When you are done entering data, press 
    VO L  to go to the next option.
    0601:TOLL LEVEL:n
    0 + DIALING?nnn
    0601:TOLL LEVEL:n
    INT’L DIAL?nnn
    0601:10+XXX DIALING
    ALLOW OR DENY TABLE?
    0601:10+XXX ALLW TBL
    ADD-A/VIEW-V/DEL-D?
    0601:10+XXX DENY TBL
    ADD-A/VIEW-V/DEL-D?
    0601:NXX DIALING
    ALLOW OR DENY TABLE? 
    						
    							0600 - Toll Restriction
    0601 - Toll Restriction Options
    DS2000 Software Manual Chapter 2: Programming411
    The previously programmed table type displays (A = allow, D = deny).
    NXX Dialing
    12. Enter A to set up the table as an allow table.
    OR
    Enter D to set up the table as a deny table.
    OR
    Enter D to convert an existing allow table into a deny table, or enter A to convert an 
    existing deny table into an allow table.
    13. Press A to add codes into the table.
    OR
    Press D to delete codes from the table.
    OR
    Press V to view the current contents of the table.
    If you press V to view the table, the bottom line of the display will show the first set of 
    table entries. Press V to see the remaining entries. The prompt 
    TABLE DONE tells you 
    when you are at the end of the table or the table is empty. The prompt 
    > tells you that there 
    is additional data in the table to view.
    If you press A or D to add codes into the table, you see the prompt 
    DATA. Just enter the 
    codes you want into the table. When entering data, new data appears to the right of the 
    previously entered data. (The system automatically assumes that every group of three dig-
    its is an entry.) 
    14. When you are done entering data, press 
    VO L  to go to the next option.
    The previously programmed table type displays (A = allow, D = deny).
    NPA Dialing
    15. Enter A to set up the table as an allow table.
    OR
    Enter D to set up the table as a deny table.
    OR
    Enter D to convert an existing allow table into a deny table, or enter A to convert an 
    existing deny table into an allow table.
    16. Press A to add codes into the table.
    OR
    Press D to delete codes from the table.
    OR
    Press V to view the current contents of the table.
    If you press V to view the table, the bottom line of the display will show the first set of 
    table entries. Press V to see the remaining entries. The prompt 
    TABLE DONE tells you 
    when you are at the end of the table or the table is empty. The prompt 
    > tells you that there 
    0601:NXX ALLOW TABLE
    ADD-A/VIEW-V/DEL-D?
    0601:NXX DENY TABLE
    ADD-A/VIEW-V/DEL-D?
    0601:NPA DIALING
    ALLOW OR DENY TABLE?
    0601:NPA ALLOW TABLE
    ADD-A/VIEW-V/DEL-D?
    0601:NPA DENY TABLE
    ADD-A/VIEW-V/DEL-D? 
    						
    							0600 - Toll Restriction
    0601 - Toll Restriction Options
    412Chapter 2: ProgrammingDS2000 Software Manual
    is additional data in the table to view.
    If you press A or D to add codes into the table, you see the prompt 
    DATA. Just enter the 
    codes you want into the table. When entering data, new data appears to the right of the 
    previously entered data. (The system automatically assumes that every group of three dig-
    its is an entry.) 
    17. When you are done entering data, press 
    VO L  to go to the next option.
    The previously programmed table type displays (A = allow, D = deny).
    6-Digit Analysis
    18. Enter A to set up the table as an allow table.
    OR
    Enter D to set up the table as a deny table.
    OR
    Enter D to convert an existing allow table into a deny table, or enter A to convert an 
    existing deny table into an allow table.
    19. Press A to add codes into the table.
    OR
    Press D to delete codes from the table.
    OR
    Press V to view the current contents of the table.
    If you press V to view the table, the bottom line of the display will show the first set of 
    table entries. Press V to see the remaining entries. The prompt 
    TABLE DONE tells you 
    when you are at the end of the table or the table is empty. The prompt 
    > tells you that there 
    is additional data in the table to view.
    If you press A or D to add codes into the table, you see the prompt 
    DATA. Just enter the 
    codes you want into the table. When entering data, new data appears to the right of the 
    previously entered data. (The system automatically assumes that every group of six digits 
    is an entry.) 
    20. When you are done entering data, press 
    VO L  to go back to the Active Dial Pad option for 
    the currently selected Toll Level.
    OR
    Press CONF to go back to the Program/Initialize option.
    OR
    Press CONF twice to exit Toll Restriction programming.
    0601:6 DGT ANALYSIS
    ALLOW OR DENY TABLE?
    0601:6 DGT ALLOW TBL
    ADD-A/VIEW-V/DEL-D?
    0601:6 DGT ALLOW TBL
    ADD-A/VIEW-V/DEL-D?
    0601:TOLL LEVEL:n
    ACTIVE DIAL PAD?nn
    0601:TOLL RESTRICT
    PROG-P / INIT-I 
    						