Nitsuko Ds2000 Software Manual
Have a look at the manual Nitsuko Ds2000 Software Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 57 Nitsuko manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
9800 - System Utilities, Part 1 9801 - Copy Command DS2000 Software Manual Chapter 2: Programming473 OR If copying to a range of extensions or trunks, enter the highest numbered extension or trunk in the range. 8. Press HOLD. 9. Press CONF to select another program to copy. OR Press CONF twice to exit the program. COPY (program) (source) COPY COMPLETE!
9900 - System Utilities, Part 2 9901 - Reset Station Port 474Chapter 2: ProgrammingDS2000 Software Manual 9900 - System Utilities, Part 2 9901 - Reset Station Port Description Use Program 9901 - Reset Station Port to reset an extension. This program also gives you the option of reviewing the status of the extension before you reset it. Conditions None Telephone Programming Instructions 1. Enter the programming mode. 2. 9901 + HOLD 3. Enter the number of the station port you want to program (1-32) + HOLD OR Press HOLD to select port 1 (extension 300). The first line of the display indicates the station port you have selected. 4. Press VO L . The extension’s name displays. 5. Press VO L . 6. Enter Y + VO L to reset the station port. OR Enter N + VO L to skip to the next station port without resetting the port. LCCPU 01.00.00 Available. 9901:RESET STA PORT STATION PORT?n 9901:STA PORT:n EXT:nnnn 9901:STA PORT:n NAME:nnnnnnnnnn 9901:STA PORT:n RESET STA PT?nnn
9900 - System Utilities, Part 2 9902 - Reset Trunk Port DS2000 Software Manual Chapter 2: Programming475 9902 - Reset Trunk Port Description LCCPU 01.00.00 Not available.
9900 - System Utilities, Part 2 9903 - System and PCB Reset 476Chapter 2: ProgrammingDS2000 Software Manual 9903 - System and PCB Reset Description LCCPU 01.00.00 Not available.
9900 - System Utilities, Part 2 9904 - Side Tone Test DS2000 Software Manual Chapter 2: Programming477 9904 - Side Tone Test Description LCCPU 01.00.00 Not available.
9900 - System Utilities, Part 2 9905 - Password 478Chapter 2: ProgrammingDS2000 Software Manual 9905 - Password Description Use Program 9905 - Password to change the system passwords. The table below shows the default system passwords. Turn to System Programming List on page 289 for more on the system pass- words. Conditions None Telephone Programming Instructions 1. Enter the programming mode. 2. 9905 + HOLD 3. Enter the level (1-3) for the password you want to change + VO L The level selected and previously programmed password displays. 4. Enter the password for the level selected + VO L OR Press VO L to leave the current entry unchanged. 5. Repeat from step 3 to enter another password level. OR Press CONF to exit the program. LCCPU 01.00.00 Available. Table 47: Password Levels Password LevelPasswordLevel System Administrator 10000 1 System Administrator 29999 2 Installer372000 3 9905:SYS PASSWORD ENTER PSWD LEVEL? 9905:SYS PASSWORD LVL x?nnnnnnnnnnnnnn 9905:SYS PASSWORD ENTER PSWD LEVEL?
9900 - System Utilities, Part 2 9906 - Database Save DS2000 Software Manual Chapter 2: Programming479 9906 - Database Save Description Use Program 9906 - Database Save to back up site data to PC Card P/N 85880 or P/N 80050- V**.**. Refer to your Hardware Manual for the specifics. Conditions The following table lists the PC Card Backup Error Messages that you may see when using the instructions below. Telephone Programming Instructions 1. Insert the PC Card into the CPU. Refer to the Hardware Manual for additional information. 2. Be sure the CPU mode switch is set to RUN. 3. Enter the programming mode. 4. 9906 + HOLD 5. Enter Y + HOLD. To quit program 9906 instead, enter N + HOLD. 6. Enter a name for the database you want to save (up to 10 characters long). Refer to Programming Names and Text Messages on page 361 if you need help when entering names. Skip this step if you want to save data in an address that already has a name assigned. 7. When you are done entering the name, press HOLD. LCCPU 01.00.00 Available. This error message: Means this: No PCCARD The PC Card is not installed. Install the PC Card and try again. ERASE FAILED The system could not overwrite an existing data base on the PC Card. Repeat the procedure. If you get the message again, try another PC Card. SAVE FAILED The system could not save data to the PC Card. Repeat the procedure. Of you get the error message again, try another PC Card. 9906:DATABASE SAVE START? 9906:DATABASE NAME 9906:DATABASE NAME (name) 9906:DB 00 (time) (name) (date)
9900 - System Utilities, Part 2 9906 - Database Save 480Chapter 2: ProgrammingDS2000 Software Manual You see the address, name and date of the first data base stored. If you data bases are stored, you see: 8. The system assigns the name you entered in step 7 to the address you select below: - Press VOL or VOL to scroll through the 12 data base addresses (DB 00 through DB 11) OR - Skip this step to select the currently displayed data base. 9. Press HOLD. Normally, you see: The PC Card Active LED is on during backup. If the address you choose already has data stored in it. you see: - Press N + HOLD to back up to step 5. OR - Press Y + HOLD to proceed. You automatically exit programming when the upload completes. 9906:DB 00 (empty) 9906:SAVING . . . . . . . . . . . 9906:DATABASE SAVE REPLACE DB nn Y/N
9900 - System Utilities, Part 2 9907 - Database Load DS2000 Software Manual Chapter 2: Programming481 9907 - Database Load Description Use Program 9907 - Database Load to load site data previously saved to PC Card P/N 85880 or P/ N 80050-V**.** into the system data base. Refer to your Hardware Manual for the specifics. Conditions The following table lists the PC Card Load Error Messages that you may see when using the instructions below. Telephone Programming Instructions 1. Insert the PC Card into the CPU. Refer to the Hardware Manual for additional information. 2. Be sure the CPU mode switch is set to RUN. 3. Enter the programming mode. 4. 9907 + HOLD 5. Enter Y + HOLD. You see the name and date of the first data base stored. If no data bases are stored, you see: 6. Press VOL or VOL to scroll through the 12 data base addresses (DB 00 through DB 11) and select the one you want to restore. 7. When the data base you want to restore displays, press HOLD. The PC Card Active LED is on during restore. You automatically exit programming when the upload completes. LCCPU 01.00.00 Available. This error message: Means this: No PCCARD The PC Card is not installed. Install the PC Card and try again. NO DATABASE There is no data stored in the data base address you selected. Select another data base address and try again. 9907:DATABASE LOAD START? 9907:DB 00 (time) (name) (date) 9907:DB 00 (empty)
9900 - System Utilities, Part 2 9999 - System Initialization 482Chapter 2: ProgrammingDS2000 Software Manual 9999 - System Initialization Description Use Program 9999 - System Initialization to initialize the system database. Conditions None Telephone Programming Instructions 1. Enter the programming mode. 2. 9999 + HOLD 3. Enter Y + HOLD to initialize the system. OR Enter N + HOLD to exit the program without initializing. If you enter Y, the system will initialize with the factory-installed default and return to the idle state. LCCPU 01.00.00 Available. ! Warning! Initializing the system erases all your programmed entries and replaces them with the factory-installed default values. 9999:INITIALIZATION INITIALIZE SYS?nnn