    							9800 - System Utilities, Part 1
    9801 - Copy Command
    DS2000 Software Manual Chapter 2: Programming473
    OR
    If copying to a range of extensions or trunks, enter the highest numbered extension or trunk in 
    the range.
    8. Press 
    HOLD.
    9. Press
     CONF to select another program to copy.
    OR
    Press 
    CONF twice to exit the program.
    COPY (program)    (source)
    COPY COMPLETE! 
    						
    							9900 - System Utilities, Part 2
    9901 - Reset Station Port
    474Chapter 2: ProgrammingDS2000 Software Manual
    9900 - System Utilities, Part 2
    9901 - Reset Station Port
    Description
    Use Program 9901 - Reset Station Port to reset an extension. This program also gives you the 
    option of reviewing the status of the extension before you reset it.
    Conditions
    None
    Telephone Programming Instructions
    1. Enter the programming mode.
    2. 9901 + 
    HOLD
    3. Enter the number of the station port you want to program (1-32) + HOLD
    OR
    Press 
    HOLD to select port 1 (extension 300).
      The first line of the display indicates the station port you have selected.
    4. Press 
    VO L .
    The extension’s name displays.
    5. Press 
    VO L .
    6. Enter Y  + 
    VO L  to reset the station port.
    OR
    Enter N + 
    VO L  to skip to the next station port without resetting the port. LCCPU 01.00.00 Available.
    9901:RESET STA PORT
    STATION PORT?n
    9901:STA PORT:n
    EXT:nnnn
    9901:STA PORT:n
    NAME:nnnnnnnnnn
    9901:STA PORT:n
    RESET STA PT?nnn 
    						
    							9900 - System Utilities, Part 2
    9902 - Reset Trunk Port
    DS2000 Software Manual Chapter 2: Programming475
    9902 - Reset Trunk Port
    Description
    LCCPU 01.00.00 Not available. 
    						
    							9900 - System Utilities, Part 2
    9903 - System and PCB Reset
    476Chapter 2: ProgrammingDS2000 Software Manual
    9903 - System and PCB Reset
    Description
    LCCPU 01.00.00 Not available. 
    						
    							9900 - System Utilities, Part 2
    9904 - Side Tone Test
    DS2000 Software Manual Chapter 2: Programming477
    9904 - Side Tone Test
    Description
    LCCPU 01.00.00 Not available. 
    						
    							9900 - System Utilities, Part 2
    9905 - Password
    478Chapter 2: ProgrammingDS2000 Software Manual
    9905 - Password
    Description
    Use Program 9905 - Password to change the system passwords. The table below shows the default 
    system passwords.  Turn to System Programming List on page 289 for more on the system pass-
    words.
    Conditions
    None
    Telephone Programming Instructions
    1. Enter the programming mode.
    2. 9905 + 
    HOLD
    3. Enter the level (1-3) for the password you want to change + VO L 
    The level selected and previously programmed password displays.
    4. Enter the password for the level selected + 
    VO L 
    OR
    Press 
    VO L  to leave the current entry unchanged.
    5. Repeat from step 3 to enter another password level.
    OR
    Press 
    CONF to exit the program. LCCPU 01.00.00 Available.
    Table 47:  Password Levels
    Password LevelPasswordLevel
    System Administrator 10000 1
    System Administrator 29999 2
    Installer372000 3
    9905:SYS PASSWORD
    ENTER PSWD LEVEL?
    9905:SYS PASSWORD
    LVL x?nnnnnnnnnnnnnn
    9905:SYS PASSWORD
    ENTER PSWD LEVEL? 
    						
    							9900 - System Utilities, Part 2
    9906 - Database Save
    DS2000 Software Manual Chapter 2: Programming479
    9906 - Database Save
    Description
    Use Program 9906 - Database Save to back up site data to PC Card P/N 85880 or P/N 80050-
    V**.**. Refer to your Hardware Manual for the specifics.
    Conditions
    The following table lists the PC Card Backup Error Messages that you may see when using the 
    instructions below.
    Telephone Programming Instructions
    1. Insert the PC Card into the CPU.
    Refer to the Hardware Manual for additional information.
    2. Be sure the CPU mode switch is set to 
    RUN.
    3. Enter the programming mode.
    4. 9906 + 
    HOLD
    5. Enter Y  + HOLD.
    To quit program 9906 instead, enter N + HOLD.
    6. Enter a name for the database you want to save (up to 10 characters long).
    Refer to Programming Names and Text Messages on page 361 if you need help when 
    entering names.
    Skip this step if you want to save data in an address that already has a name assigned.
    7. When you are done entering the name, press 
    HOLD. LCCPU 01.00.00 Available.
    This error message: Means this:
    No PCCARD
    The PC Card is not installed.
    Install the PC Card and try again.
    ERASE FAILED
    The system could not overwrite an existing data 
    base on the PC Card.
    Repeat the procedure. If you get the message 
    again, try another PC Card.
    SAVE FAILED
    The system could not save data to the PC Card.
    Repeat the procedure. Of you get the error message 
    again, try another PC Card.
    9906:DATABASE SAVE
    START?
    9906:DATABASE NAME
    9906:DATABASE NAME
    (name)
    9906:DB 00 (time)
    (name) (date) 
    						
    							9900 - System Utilities, Part 2
    9906 - Database Save
    480Chapter 2: ProgrammingDS2000 Software Manual
    You see the address, name and date of the first data base stored. If you data bases are 
    stored, you see:
    8. The system assigns the name you entered in step 7 to the address you select below:
    - Press VOL 
     or VOL  to scroll through the 12 data base addresses (DB 00 through DB 11)
    OR
    - Skip this step to select the currently displayed data base.
    9. Press 
    HOLD.
    Normally, you see:
    The PC Card Active LED is on during backup.
    If the address you choose already has data stored in it. you see:
    - Press N + 
    HOLD to back up to step 5.
         OR
    - Press Y + 
    HOLD to proceed.
    You automatically exit programming when the upload completes.
    9906:DB 00
    (empty)
    9906:SAVING
    . . . . . . . . . . .
    9906:DATABASE SAVE
    REPLACE DB nn Y/N 
    						
    							9900 - System Utilities, Part 2
    9907 - Database Load
    DS2000 Software Manual Chapter 2: Programming481
    9907 - Database Load
    Description
    Use Program 9907 - Database Load to load site data previously saved to PC Card P/N 85880 or P/
    N 80050-V**.** into the system data base. Refer to your Hardware Manual for the specifics.
    Conditions
    The following table lists the PC Card Load Error Messages that you may see when using the 
    instructions below.
    Telephone Programming Instructions
    1. Insert the PC Card into the CPU.
    Refer to the Hardware Manual for additional information.
    2. Be sure the CPU mode switch is set to 
    RUN.
    3. Enter the programming mode.
    4. 9907 + 
    HOLD
    5. Enter Y  + HOLD.
    You see the name and date of the first data base stored. If no data bases are stored, you 
    see:
    6. Press VOL 
     or VOL  to scroll through the 12 data base addresses (DB 00 through DB 11) 
    and select the one you want to restore.
    7. When the data base you want to restore displays, press 
    HOLD.
    The PC Card Active LED is on during restore.
    You automatically exit programming when the upload completes. LCCPU 01.00.00 Available.
    This error message: Means this:
    No PCCARD
    The PC Card is not installed.
    Install the PC Card and try again.
    NO DATABASE
    There is no data stored in the data base address you 
    selected.
    Select another data base address and try again.
    9907:DATABASE LOAD
    START?
    9907:DB 00 (time)
    (name)  (date)
    9907:DB 00
    (empty) 
    						
    							9900 - System Utilities, Part 2
    9999 - System Initialization
    482Chapter 2: ProgrammingDS2000 Software Manual
    9999 - System Initialization
    Description
    Use Program 9999 - System Initialization to initialize the system database.
    Conditions
    None
    Telephone Programming Instructions
    1. Enter the programming mode.
    2. 9999 + 
    HOLD
    3. Enter Y  + HOLD to initialize the system.
    OR
    Enter N + 
    HOLD to exit the program without initializing.
    If you enter Y, the system will initialize with the factory-installed default and return to 
    the idle state. LCCPU 01.00.00 Available.
    ! Warning!
    Initializing the system erases all your programmed entries 
    and replaces them with the factory-installed default values.
    9999:INITIALIZATION
    INITIALIZE SYS?nnn 
    						