NEC Neax 2400 Ipx System Operations And Maintenance Manual
Have a look at the manual NEC Neax 2400 Ipx System Operations And Maintenance Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 1168 NEC manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

NDA-24307 CHAPTER 8 Page 693 Issue 1 SPTS: Scanning of Port Status Note 1: The parameter is only for KIND = 1. Note 2:The parameter is only for KIND= 2. DATA MEANING DATA MEANING 901 Attendant Console 902 Originating Register Trunk 903 Incoming Register Trunk 904 MF Receiver 905 Sender Trunk DP/PB 906 PB Receiver for Automated Attendant Service 907AMP 908Not used 909 Three-Way Conference Trunk 910-912 Not used 913 Three-Way Conference Trunk for ATTCON 914 Not used 915 Night Attendant 916 MFC Register 917 MFC Sender 918 Not used 919-926 Modem 927, 928 Not used 929 MFC Sender 930 Rate Adapter Conversion Trunk 931 Not used 932-947 Not used

CHAPTER 8 NDA-24307 Page 694 Issue 1 SRTS: Scanning of Route Status SRTS:Scanning of Route Status 1. Functional Outline This command displays the designated trunk status (Busy/Idle) at predetermined intervals. A maximum of 15 routes can be scanned. 2. Parameters Input data RT: R o u t e N u m b e r Interval Time Display data Number of Idle TK Number of Busy

NDA-24307 CHAPTER 8 Page 695 Issue 1 XHFD: X-RAY HD or FDD Diagnosis XHFD:X-RAY HD or FDD Diagnosis 1. Functional Outline This command is used to execute the following diagnoses. Hard Disk Diagnosis By executing read/write check on the files in the hard disk of the PBX, this command diagnoses the hard disk for its normality. If an error has been found as a result of the diagnosis, this command displays the information on the faulty logical drive and the number of faulty sectors on the MAT screen. The information can also be output by the printer. Floppy Disk Diagnosis By executing cleaning of the floppy disk drive in the PBX, this command diagnoses the floppy disk drive for its normality. If the cleaning has not finished normally, a diagnosis error has been found as a result of the diagnosis. The result message may be displayed on the MAT screen or printed out by the printer. 2. Parameters Input data FUNCTION: HD/FDD Designation [1/2] 1=Diagnosis of HD (Hard Disk) 2=Diagnosis of FDD (Floppy Disk Drive) AREA: Area Designation [0/l] Note 0=All Files 1=Program Files SYSTEM: System (0/1) 0=No.0 System 1=No.1 System Note:“AREA” parameter appears only when “1(=HD)” is selected in the “FUNCTION” parameter. Buttons Exe: Click to execute the diagnosis. Close: Click to exist this command.

CHAPTER 8 NDA-24307 Page 696 Issue 1 XHFD: X-RAY HD or FDD Diagnosis Display data FAULT DRIVE: Fault Drive Number [0-4] 0=- 1=#0 2=#1 3=#2 4=#3 FAULT SECTOR: Number of Fault Sector [0-65535] MESSAGE: Result of diagnosis [0-255] 0=Normal End 1=Hard disk read test practice error 2=Floppy disk drive cleaning practice error 3=Common part parameter error (Data length error) 4=FDD cleaning abnormal end (FD not in drive) 5=Individual part parameter error (Function error) 6=Individual part parameter error (Sub function error) 7=Individual part parameter error (Device error) 8=Individual part parameter error (Drive selection error) 9=Individual part parameter error (Data ID error) 10=Individual part parameter error (Processor ID error) 11=Individual part parameter error (File ID error) 12=Individual part parameter error (File name error) 13=Request order error (Health check send error) 14=Request order error (Data send signal error) 15=Internal error (File open error) 16=Internal error (File read error) 17=Internal error (File close error) 18=Internal error (FAT error) 19=Internal error (SCSIC error) 20=Internal error (other) 21=Hard interface abnormal end 22-255=-