    							NDA-24307 CHAPTER 8
    Page 693
    Issue 1
    SPTS: Scanning of Port Status
    Note 1:
    The parameter is only for KIND = 1.
    Note 2:The parameter is only for KIND= 2.
    DATA MEANING DATA MEANING
    901 Attendant Console 902 Originating Register Trunk
    903 Incoming Register Trunk 904 MF Receiver
    905 Sender Trunk DP/PB 906 PB Receiver for Automated Attendant Service
    907AMP 908Not used
    909 Three-Way Conference Trunk 910-912 Not used
    913 Three-Way Conference Trunk for ATTCON 914 Not used
    915 Night Attendant 916 MFC Register
    917 MFC Sender 918 Not used
    919-926 Modem 927, 928 Not used
    929 MFC Sender 930 Rate Adapter Conversion Trunk
    931 Not used 932-947 Not used 
    						
    							CHAPTER 8 NDA-24307
    Page 694
    Issue 1
    SRTS: Scanning of Route Status
    SRTS:Scanning of Route Status
    1. Functional Outline
    This command displays the designated trunk status (Busy/Idle) at predetermined intervals. A maximum of 15
    routes can be scanned.
    2. Parameters
    Input data
    RT: R o u t e  N u m b e r
    Interval Time
    Display data
    Number of Idle TK
    Number of Busy 
    						
    							NDA-24307 CHAPTER 8
    Page 695
    Issue 1
    XHFD: X-RAY HD or FDD Diagnosis
    XHFD:X-RAY HD or FDD Diagnosis
    1. Functional Outline
    This command is used to execute the following diagnoses.
    Hard Disk Diagnosis
    By executing read/write check on the files in the hard disk of the PBX, this command diagnoses the hard
    disk for its normality.
    If an error has been found as a result of the diagnosis, this command displays the information on the faulty
    logical drive and the number of faulty sectors on the MAT screen. The information can also be output by
    the printer.
    Floppy Disk Diagnosis
    By executing cleaning of the floppy disk drive in the PBX, this command diagnoses the floppy disk drive
    for its normality.
    If the cleaning has not finished normally, a diagnosis error has been found as a result of the diagnosis. The
    result message may be displayed on the MAT screen or printed out by the printer.
    2. Parameters
    Input data
    FUNCTION: HD/FDD Designation [1/2]
    1=Diagnosis of HD (Hard Disk)
    2=Diagnosis of FDD (Floppy Disk Drive)
    AREA: Area Designation [0/l] 
    Note
    0=All Files
    1=Program Files
    SYSTEM: System (0/1)
    0=No.0 System
    1=No.1 System
    Note:“AREA” parameter appears only when “1(=HD)” is selected in the “FUNCTION” parameter.
    Buttons
    Exe: Click to execute the diagnosis.
    Close: Click to exist this command. 
    						
    							CHAPTER 8 NDA-24307
    Page 696
    Issue 1
    XHFD: X-RAY HD or FDD Diagnosis
    Display data
    FAULT DRIVE: Fault Drive Number [0-4]
    0=-
    1=#0
    2=#1
    3=#2
    4=#3
    FAULT SECTOR: Number of Fault Sector [0-65535]
    MESSAGE: Result of diagnosis [0-255]
    0=Normal End
    1=Hard disk read test practice error
    2=Floppy disk drive cleaning practice error
    3=Common part parameter error (Data length error)
    4=FDD cleaning abnormal end (FD not in drive)
    5=Individual part parameter error (Function error)
    6=Individual part parameter error (Sub function error)
    7=Individual part parameter error (Device error)
    8=Individual part parameter error (Drive selection error)
    9=Individual part parameter error (Data ID error)
    10=Individual part parameter error (Processor ID error)
    11=Individual part parameter error (File ID error)
    12=Individual part parameter error (File name error)
    13=Request order error (Health check send error)
    14=Request order error (Data send signal error)
    15=Internal error (File open error)
    16=Internal error (File read error)
    17=Internal error (File close error)
    18=Internal error (FAT error)
    19=Internal error (SCSIC error)
    20=Internal error (other)
    21=Hard interface abnormal end
    22-255=- 
    						
    All NEC manuals Comments (0)