NDA-24307 CHAPTER 8 Page 623 Issue 1 DCBD: Display of Call Block Entry Data DCBD:Display of Call Block Entry Data 1. Functional Outline This command is used to display the following Call Block data, assigned to a station: Number of station/trunk whose call is to be blocked (in the remainder of this page, denoted as “Restriction Number”) Registered “Restriction Numbers” in total These data can be obtained by entering any of the station’s Telephone Number (TYPE 1), Physical Station Number (TYPE 2) or LENS (TYPE 3) in the parameters below: 2. Parameters Input Data TYPE: Selection of Input Data Type TYPE 1 (Input Data = UGN, TELN) Note TYPE 2 (Input Data = FPC, TN, STN)Note TYPE 3 (Input Data = FPC, LENS)Note READ (button to view the Display Data) EXIT (button to exit) Note:When using this command, first choose the input data type (Type 1 - 3) in the “TYPE” selection list box. Then the following parameters appear, according to the selected data type. When TYPE 1 is selected: UGN (User Group Number) TELN (Telephone Number [Max.16 digits]) When TYPE 2 is selected: FPC (Fusion Point Code [1-253]) TN (Tenant Number [Max.3 digits]) STN (Physical Station Number [Max.6 digits]) When TYPE 3 is selected: FPC (Fusion Point Code [1-253]) LENS (Line Equipment Number)

CHAPTER 8 NDA-24307 Page 624 Issue 1 DCBD: Display of Call Block Entry Data Display Data CNT: Registered “Restriction Numbers” in total (1-5) DC: Each “Restriction Number” When Physical Station Number is registered – Max.6 digits When Telephone Number is registered – Max.16 digits When Trunk Call Number is registered – Max.32 digits

NDA-24307 CHAPTER 8 Page 625 Issue 1 DCEN: Display of Connection Trunk LENS Data for LDM DCEN:Display of Connection Trunk LENS Data for LDM 1. Functional Outline This command is used to display the registered connection trunk/route data by designating LENS. 2. Parameters Input data C_LENS: Line Equipment Number [6 digits] Display data C_RT: Connection Route Number [1-1023] C_TK: Connection Trunk Number [1-4095] RT: External Route Number TK: Trunk Number [1-255] TN: Tenant Number

CHAPTER 8 NDA-24307 Page 626 Issue 1 DCON: Display of Connection Status DCON:Display of Connection Status 1. Functional Outline This command displays the connection status of the station and trunks. If the specified station or trunk is busy, the connected party is displayed. 2. Parameters Input data TYPE: Kind of Connection Status (1-4) 1=Station of Connection Status 2=Trunk of Connection Status 3=LENS of Connection Status 4=Connection Trunk of Connection Status (Fusion Network) TN: Note 1 STN: Maximum number of digits is 5 for Business system, and 6 for Hotel system. Note 1 RT:Note 2 TK:Note 2 LEN:Note 3 C_RT: Connection Route Number (1-1023) Note 4 C_TK: Connection Trunk Number (1-4095) Note 4 Note 1: This data is valid when Type= 1. Note 2:This data is valid when Type= 2. Note 3:This data is valid when Type= 3. Note 4:This data is valid when Type= 4.

NDA-24307 CHAPTER 8 Page 627 Issue 1 DFTD: Display of System Message Details DFTD:Display of System Message Details 1. Functional Outline This command is necessary to print the system messages detected by the Fault Diagnostic programs. When the fault scanning (Scanning PBX) is effective, the MAT can scan the PBX status by polling every 20 sec, (default setting is Effective.) If the PBX has faults, this command executes automatically. 2. Parameters Input data New/Old Show Details: YES/NO

CHAPTER 8 NDA-24307 Page 628 Issue 1 DISS: Display of Program Issue DISS:Display of Program Issue 1. Functional Outline This command outputs to the printer and displays at the MAT, the program information (version, issue No. and date) in the main memory, and the program information (SP No.and issue No.) in the port microprocessor memory mounted in each circuit card in the PBX. 2. Parameters Input data Type of Issue: Main Memory/Port Microprocessor Module Group: Note 1 Unit:Note 1 Display data Type: Main Memory/Boot ROM/IP/ACDP Note 2 Version:Note 2 Issue:Note 2 Date:Note 2 Group: 00-23 Note 1 SP No.: 4 digits Note 1 Issue: ASCII 2 digits Note 1 Note 1: This data is valid when Port Microprocessor is designated. Note 2:This data is valid when Main Memory is designated.

NDA-24307 CHAPTER 8 Page 629 Issue 1 DLEN: Display of LENS Data DLEN:Display of LENS Data 1. Functional Outline This command displays the data (station data or trunk data) assigned for a designated LEN. For Hotel system, Room Class and Floor Service Data [Annex (ANX), Ground/Underground (G), Floor (FLR)] displays also. 2. Parameters Input data LENS Display data TN STN: Maximum 6 digits TEC: Telephone Equipment Number (1-31) RSC: Route Restriction Class (0-15) SFC: Service Feature Class (0-15) ROOM CLASS: (0-15) ANX: Annex (0-3) G: 0/1=Ground/Underground FLR: Floor (1-127) RT: The Internal Route Number DATA MEANING DATA MEANING 1 DP (10pps) 2 PB 3 DP/PB 4 DP (20 pps) 5-11 Not used 12 D term 13 Data Terminal via Dterm14 Hot Line 15 CAS Line 16 Data Terminal via Data Module 17 Not used 23 ISDN Terminal 18 Virtual Line Appearance (for D term Multi-Line)19-22 Not used 24-26 Not used 27 Eight Conference Equipment 28-31 Not used

CHAPTER 8 NDA-24307 Page 630 Issue 1 DLEN: Display of LENS Data TK C_RT: Connection Route Number (1-1023) C_TK: Connection Trunk Number (1-4095) DATA MEANING DATA MEANING 901 Attendant Console 902 Originating Register Trunk 903 Incoming Register Trunk 904 MF Receiver 905 Sender Trunk DP/PB 906 PB Receiver for Automated Attendant Service 907AMP 908Not used 909 Three-Way Conference Trunk 910-912 Not used 913 Three-Way Conference Trunk for ATTCON 914 Not Used 915 Night Attendant Console 916 MFC Register 917 MFC Sender 918 Not used 919-926 Modem 927, 928 Not used 929 Data Signaling Trunk-Option 930 Rate Adapter Conversion Trunk 931-947 Not used

NDA-24307 CHAPTER 8 Page 631 Issue 1 DLSL: Display of Lock Out Station - LENS DLSL:Display of Lock Out Station - LENS 1. Functional Outline This command prints the LENS of stations in lockout state. 2. Parameters Input data TYPE: Type of Printout (1-3) 1=Printout of all LEN in lockout 2=Printout of locked out LEN in the designated Module Group 3=Printout of locked out LEN in the designated Unit MG: Note 1, Note 2 UNIT:Note 2 Note 1: The parameter is valid only when Type= 2. Note 2:The parameter is valid only when Type= 3. Display data LENS

CHAPTER 8 NDA-24307 Page 632 Issue 1 DLSS: Display of Lockout Station - Number DLSS:Display of Lockout Station - Number 1. Functional Outline This command prints the stations in lockout state by station number. 2. Parameters Input data TYPE: Type of Printout (1-3) 1=Printout of all lockout stations 2=Printout of lockout stations by tenant 3=Printout of lockout stations within a specified range of station number. TN: Note 1, Note 2 START STN: Maximum 6 digitsNote 2 END STN: Maximum 6 digitsNote 2 Note 1: The parameter is valid only when Type= 2. Note 2:The parameter is valid only when Type= 3. Display data CNT: Count TN STN LENS