    							NDA-24307 CHAPTER 8
    Page 623
    Issue 1
    DCBD: Display of Call Block Entry Data
    DCBD:Display of Call Block Entry Data
    1. Functional Outline
    This command is used to display the following Call Block data, assigned to a station:
    Number of station/trunk whose call is to be blocked (in the remainder of this page, denoted as “Restriction
    Number”)
    Registered “Restriction Numbers” in total
    These data can be obtained by entering any of the station’s Telephone Number (TYPE 1), Physical Station
    Number (TYPE 2) or LENS (TYPE 3) in the parameters below:
    2. Parameters
    Input Data
    TYPE: Selection of Input Data Type
    TYPE 1 (Input Data = UGN, TELN)
    Note
    TYPE 2 (Input Data = FPC, TN, STN)Note
    TYPE 3 (Input Data = FPC, LENS)Note
    READ (button to view the Display Data)
    EXIT (button to exit)
    Note:When using this command, first choose the input data type (Type 1 - 3) in the “TYPE” selection list box.
    Then the following parameters appear, according to the selected data type.
    When TYPE 1 is selected: UGN (User Group Number)
    TELN (Telephone Number [Max.16 digits])
    When TYPE 2 is selected: FPC (Fusion Point Code [1-253])
    TN (Tenant Number [Max.3 digits])
    STN (Physical Station Number [Max.6 digits])
    When TYPE 3 is selected: FPC (Fusion Point Code [1-253])
    LENS (Line Equipment Number) 
    						
    							CHAPTER 8 NDA-24307
    Page 624
    Issue 1
    DCBD: Display of Call Block Entry Data
    Display Data
    CNT: Registered “Restriction Numbers” in total (1-5)
    DC: Each “Restriction Number”
    When Physical Station Number is registered – Max.6 digits
    When Telephone Number is registered – Max.16 digits
    When Trunk Call Number is registered – Max.32 digits 
    						
    							NDA-24307 CHAPTER 8
    Page 625
    Issue 1
    DCEN: Display of Connection Trunk LENS Data for LDM
    DCEN:Display of Connection Trunk LENS Data for LDM
    1. Functional Outline
    This command is used to display the registered connection trunk/route data by designating LENS.
    2. Parameters
    Input data
    C_LENS: Line Equipment Number [6 digits]
    Display data
    C_RT: Connection Route Number [1-1023]
    C_TK: Connection Trunk Number [1-4095]
    RT: External Route Number
    TK: Trunk Number [1-255]
    TN: Tenant Number 
    						
    							CHAPTER 8 NDA-24307
    Page 626
    Issue 1
    DCON: Display of Connection Status
    DCON:Display of Connection Status
    1. Functional Outline
    This command displays the connection status of the station and trunks. If the specified station or trunk is busy,
    the connected party is displayed.
    2. Parameters
    Input data
    TYPE: Kind of Connection Status (1-4)
    1=Station of Connection Status
    2=Trunk of Connection Status
    3=LENS of Connection Status
    4=Connection Trunk of Connection Status (Fusion Network)
    TN:
    Note 1
    STN: Maximum number of digits is 5 for Business system, and 6 for Hotel system. Note 1
    RT:Note 2
    TK:Note 2
    LEN:Note 3
    C_RT: Connection Route Number (1-1023) Note 4
    C_TK: Connection Trunk Number (1-4095) Note 4
    Note 1:
    This data is valid when Type= 1.
    Note 2:This data is valid when Type= 2.
    Note 3:This data is valid when Type= 3.
    Note 4:This data is valid when Type= 4. 
    						
    							NDA-24307 CHAPTER 8
    Page 627
    Issue 1
    DFTD: Display of System Message Details
    DFTD:Display of System Message Details
    1. Functional Outline
    This command is necessary to print the system messages detected by the Fault Diagnostic programs.
    When the fault scanning (Scanning PBX) is effective, the MAT can scan the PBX status by polling every 20
    sec, (default setting is Effective.)
    If the PBX has faults, this command executes automatically.
    2. Parameters
    Input data
    New/Old
    Show Details: YES/NO 
    						
    							CHAPTER 8 NDA-24307
    Page 628
    Issue 1
    DISS: Display of Program Issue
    DISS:Display of Program Issue
    1. Functional Outline
    This command outputs to the printer and displays at the MAT, the program information (version, issue No. and
    date) in the main memory, and the program information (SP No.and issue No.) in the port microprocessor
    memory mounted in each circuit card in the PBX.
    2. Parameters
    Input data
    Type of Issue: Main Memory/Port Microprocessor
    Module Group:
    Note 1
    Unit:Note 1
    Display data
    Type: Main Memory/Boot ROM/IP/ACDP 
    Note 2
    Version:Note 2
    Issue:Note 2
    Date:Note 2
    Group: 00-23 Note 1
    SP No.: 4 digits Note 1
    Issue: ASCII 2 digits Note 1
    Note 1:
    This data is valid when Port Microprocessor is designated.
    Note 2:This data is valid when Main Memory is designated. 
    						
    							NDA-24307 CHAPTER 8
    Page 629
    Issue 1
    DLEN: Display of LENS Data
    DLEN:Display of LENS Data
    1. Functional Outline
    This command displays the data (station data or trunk data) assigned for a designated LEN. For Hotel system,
    Room Class and Floor Service Data [Annex (ANX), Ground/Underground (G), Floor (FLR)] displays also.
    2. Parameters
    Input data
    LENS
    Display data
    TN
    STN: Maximum 6 digits
    TEC: Telephone Equipment Number (1-31)
    RSC: Route Restriction Class (0-15)
    SFC: Service Feature Class (0-15)
    ROOM CLASS: (0-15)
    ANX: Annex (0-3)
    G: 0/1=Ground/Underground
    FLR: Floor (1-127)
    RT: The Internal Route Number
    DATA MEANING DATA MEANING
    1 DP (10pps) 2 PB
    3 DP/PB 4 DP (20 pps)
    5-11 Not used 12 D
    term
    13 Data Terminal via Dterm14 Hot Line
    15 CAS Line 16 Data Terminal via Data Module
    17 Not used 23 ISDN Terminal
    18 Virtual Line Appearance (for D
    term 
    Multi-Line)19-22 Not used
    24-26 Not used 27 Eight Conference Equipment
    28-31 Not used 
    						
    							CHAPTER 8 NDA-24307
    Page 630
    Issue 1
    DLEN: Display of LENS Data
    TK
    C_RT: Connection Route Number (1-1023)
    C_TK: Connection Trunk Number (1-4095)
    DATA MEANING DATA MEANING
    901 Attendant Console 902 Originating Register Trunk
    903 Incoming Register Trunk 904 MF Receiver
    905 Sender Trunk DP/PB 906 PB Receiver for Automated Attendant Service
    907AMP 908Not used
    909 Three-Way Conference Trunk 910-912 Not used
    913 Three-Way Conference Trunk for ATTCON 914 Not Used
    915 Night Attendant Console 916 MFC Register
    917 MFC Sender 918 Not used
    919-926 Modem 927, 928 Not used
    929 Data Signaling Trunk-Option 930 Rate Adapter Conversion Trunk
    931-947 Not used 
    						
    							NDA-24307 CHAPTER 8
    Page 631
    Issue 1
    DLSL: Display of Lock Out Station - LENS
    DLSL:Display of Lock Out Station - LENS
    1. Functional Outline
    This command prints the LENS of stations in lockout state.
    2. Parameters
    Input data
    TYPE: Type of Printout (1-3)
    1=Printout of all LEN in lockout
    2=Printout of locked out LEN in the designated Module Group
    3=Printout of locked out LEN in the designated Unit
    MG:
    Note 1, Note 2
    UNIT:Note 2
    Note 1:
    The parameter is valid only when Type= 2.
    Note 2:The parameter is valid only when Type= 3.
    Display data
    LENS 
    						
    							CHAPTER 8 NDA-24307
    Page 632
    Issue 1
    DLSS: Display of Lockout Station - Number
    DLSS:Display of Lockout Station - Number
    1. Functional Outline
    This command prints the stations in lockout state by station number.
    2. Parameters
    Input data
    TYPE: Type of Printout (1-3)
    1=Printout of all lockout stations
    2=Printout of lockout stations by tenant
    3=Printout of lockout stations within a specified range of station number.
    TN:
    Note 1, Note 2
    START STN: Maximum 6 digitsNote 2
    END STN: Maximum 6 digitsNote 2
    Note 1:
    The parameter is valid only when Type= 2.
    Note 2:The parameter is valid only when Type= 3.
    Display data
    CNT: Count
    TN
    STN
    LENS 
    						
    All NEC manuals Comments (0)