    							NDA-24307 CHAPTER 3
    Page 93
    Issue 1
    SYSTEM MESSAGES
    This message (for the ISW only) displays when a TSW card (both systems) of ISW fails to receive the CLK/
    FH signals, sent from the LN side.
    ➀ TSW detected as faulty
    Note:Both b0 and b1 are displayed as “1.”
    ➁,➂ Details on the fault (TSW No. 0 
    side)
    ➁
    ➂
    1: XX00 XXXX XXXX 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀  ➁ ➂
    ➃ ➄
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b1 b0
    b7 b6 b5 b4 b3 b2 b1 b0
    b7 b6 b5 b4 b3 b2 b1 b0
    LN13 LN12 LN11 LN10 LN03 LN02 LN01 LN00
    b7 b6 b5 b4 b3 b2 b1 b0
    LN33 LN32 LN31 LN30 LN23 LN22 LN21 L200
    Default Alarm:
    NON1-YLN 
    →
    →→ → ISW CLK/FH Failure (Both)
    Default Grade:
    0Grade Modified: Lamp Modified:
    b0: 0/1 = -/No. 0 system
    b1: 0/1 = -/No. 1 system
    The bits here correspond to “LN00” through “LN33” lamps, apiece, on a 
    TSW (PU-SW00) card of No. 0 system. If “1” is set, the corresponding PCM 
    traffic has encountered a CLK/FH failure.
    0: -
    1: LN 
    → ISW CLK/FH Failure 
    						
    							CHAPTER 3 NDA-24307
    Pag e 9 4
    Issue 1
    SYSTEM MESSAGES
    ➃,➄ Details on the fault (TSW No. 1 
    side)
    ➃
    ➄
    Note 1:For more information on each lamp, refer to the “Circuit Card Manual.” b7 b6 b5 b4 b3 b2 b1 b0
    b7 b6 b5 b4 b3 b2 b1 b0
    LN13 LN12 LN11 LN10 LN03 LN02 LN01 LN00
    b7 b6 b5 b4 b3 b2 b1 b0
    LN33 LN32 LN31 LN30 LN23 LN22 LN21 L200
    The bits here correspond to “LN00” through “LN33” lamps, apiece, on a 
    TSW (PU-SW00) card of No. 1 system. If “1” is set, the corresponding PCM 
    traffic has encountered a CLK/FH failure.
    0: -
    1: LN 
    → ISW CLK/FH Failure 
    						
    							NDA-24307 CHAPTER 3
    Page 95
    Issue 1
    SYSTEM MESSAGES
    This message (for the ISW only) displays when LN → ISW CLK/FH failure has recovered and issues the [1-
    X, 1-Y] system messages.
    ➀ TSW detected as fault recovery
    Note:When fault recovery is detected in both No. 0/No. 1 system, “1” is set in b0 and b1 simultaneously.
    ➁,➂ Details on the recovered traffic 
    (TSW No. 0 side)
    ➁
    ➂
    Note 1:This data is displayed when b0 of ➀ is set as “1.”
    Note 2:For more information on each lamp, refer to the “Circuit Card Manual.”
    1: XX00 XXXX XXXX 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀  ➁ ➂
    ➃ ➄
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b1 b0
    b7 b6 b5 b4 b3 b2 b1 b0
    b7 b6 b5 b4 b3 b2 b1 b0
    LN13 LN12 LN11 LN10 LN03 LN02 LN01 LN00
    b7 b6 b5 b4 b3 b2 b1 b0
    LN33 LN32 LN31 LN30 LN23 LN22 LN21 L200
    Default Alarm:
    NON1-ZLN 
    →
    →→ → ISW CLK/FH Release
    Default Grade:
    0Grade Modified: Lamp Modified:
    b0: 0/1 = -/No. 0 system
    b1: 0/1 = -/No. 1 system
    The bits here correspond to “LN00” through “LN33” lamps, apiece, on a 
    TSW (PU-SW00) card of No. 0 system. If “1” is set, the corresponding PCM 
    traffic, once detected as faulty, has recovered.
    0: -
    1: Recovery of LN 
    → ISW CLK/FH Failure 
    						
    							CHAPTER 3 NDA-24307
    Pag e 9 6
    Issue 1
    SYSTEM MESSAGES
    ➃,➄ Details on the recovered traffic 
    (TSW No. 1 side)
    ➃
    ➄
    Note 1:This data is displayed when b1 of ➁ is set as “1.”
    Note 2:For more information on each lamp, refer to the “Circuit Card Manual.” b7 b6 b5 b4 b3 b2 b1 b0
    b7 b6 b5 b4 b3 b2 b1 b0
    LN13 LN12 LN11 LN10 LN03 LN02 LN01 LN00
    b7 b6 b5 b4 b3 b2 b1 b0
    LN33 LN32 LN31 LN30 LN23 LN22 LN21 L200
    The bits here correspond to “LN00” through “LN33” lamps, apiece, on a 
    TSW (PU-SW00) card of No. 1 system. If “1” is set, the corresponding PCM 
    traffic, once detected as faulty, has recovered.
    0: -
    1: LN 
    → ISW CLK/FH Failure 
    						
    							NDA-24307 CHAPTER 3
    Page 97
    Issue 1
    SYSTEM MESSAGES
    This message displays when a C-level program abnormal state is detected as permanent. When the Port
    Microprocessor (PM) on an LC/TRK card detects the abnormal state, the PM places the card into make-busy
    status. If the failure occurs more than 15 times an hour, the system judges the failure as permanent, and issues
    the [3-B] system message.
    ➀Faulty Circuit Card Mounting 
    Location
    1: XX00 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀
     
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b7 b6 b5 b4 b3 b2 b1 b0
    Default Alarm:
    MN3-BC-Level Infinite Loop (Permanent)Default Grade:
    3Grade Modified: Lamp Modified:
    b0-b4: Group
    b5-b6: Unit (0-3)
    b7: Module Group
    0/1 = Even-numbered MG/Odd-numbered MG 
    						
    							CHAPTER 3 NDA-24307
    Pag e 9 8
    Issue 1
    SYSTEM MESSAGES
    This message displays when C-level program is detected as abnormal by the Port Microprocessor (PM)
    mounted on an LC/TRK card. If the failure occurs less than 15 times/hour, and a B-monitor/Initial restart
    executes as the result, the failure is judged as temporary and this message is created.
    ➀Faulty Circuit Card Mounting 
    Location
    ➁ PM Restart Type
    Note:B-monitor Restart: Ports whose link have already been established remain connected. Ports processing
    a call-origination may be released.
    Initial Restart: All ports on the circuit card are forcibly released to be placed in idle state.
    1: XX0X 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀ ➁
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b7 b6 b5 b4 b3 b2 b1 b0
    b0
    Default Alarm:
    SUP3-CC-Level Infinite Loop (Temporary)Default Grade:
    1Grade Modified: Lamp Modified:
    b0-b4: Group 
    b5-b6: Unit (0-3)
    b7: Module Group
    0/1 = Even-numbered MG/Odd-numbered MG
    b0: 0/1 = B-monitor/Initial Restart     Note 
    						
    							NDA-24307 CHAPTER 3
    Page 99
    Issue 1
    SYSTEM MESSAGES
    At the periodic interval, the CPU sends diagnosis data to the Port Microprocessor (PM) on LC/TRK cards in
    order to monitor the PM. If the CPU cannot receive the return data within a predetermined period of time, the
    system displays this data. When the failure is detected more than 15 times per hour, the failure is judged as
    permanent.
    ➀ Faulty Circuit Card Location
    See Chapter 5 for repair procedure.
    1: XX00 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀ 
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b7 b6 b5 b4 b3 b2 b1 b0
    Default Alarm:
    MN3-DLock-Up Failure (Permanent)Default Grade:
    3Grade Modified: Lamp Modified:
    b0-b4: Group
    b5-b6: Unit (0-3)
    b7: Module Group
    0/1 = Even-numbered MG/Odd-numbered MG 
    						
    							CHAPTER 3 NDA-24307
    Page 100
    Issue 1
    SYSTEM MESSAGES
    At the periodic interval, the CPU sends diagnosis data to the Port Microprocessor (PM) on LC/TRK cards in
    order to monitor the PM. If the CPU cannot receive the return data within a predetermined period of time, the
    system displays this data. When the failure is detected less than 15 times per hour, the failure is judged as
    temporary.
    ➀ Faulty Circuit Card Location
    ➁ PM Restart Type
    1: XXXX 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀ ➁
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b7 b6 b5 b4 b3 b2 b1 b0
    b0
    Default Alarm:
    SUP3-ELock-Up Failure (Temporary)Default Grade:
    1Grade Modified: Lamp Modified:
    b0-b4: Group 
    b5-b6: Unit (0-3)
    b7: Module Group
    0/1 = Even-numbered MG/Odd-numbered MG
    b0: 0/1 = B-monitor/Initial Restart 
    						
    							NDA-24307 CHAPTER 3
    Page 101
    Issue 1
    SYSTEM MESSAGES
    This message displays when over current of the operating power (DC-48V) is supplied from the ATI/ELC
    circuit card to the Attendant Console/Dterm. When this fault occurs, the related circuit card is placed into make-
    busy state and stops supplying power.
    ➀ Faulty PM Location
    1: XX00 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀ 
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b7 b6 b5 b4 b3 b2 b1 b0
    Default Alarm:
    SUP3-F-48V Over CurrentDefault Grade:
    3Grade Modified: Lamp Modified:
    b0-b4: Group
    b5, b6: Unit
    b7: Module Group
    0/1 = Even-numbered MG/Odd-numbered MG 
    						
    							CHAPTER 3 NDA-24307
    Page 102
    Issue 1
    SYSTEM MESSAGES
    This message displays when a wire of the line between the LC circuit card and the telephone set is short-
    circuited with ground.
    ➀ Faulty Circuit Card Location
    ➁ Faulty Circuit Card Location
    Note:This message displays when using the specific LC card providing the above function.
    1: XXXX 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀ ➁
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b7 b6 b5 b4 b3 b2 b1 b0
    b7 b6 b5 b4 b3 b2 b1 b0
    Default Alarm:
    SUP3-GGround FailureDefault Grade:
    1Grade Modified: Lamp Modified:
    b0-b2: Circuit No. (0-7)
    b3-b7: Circuit card No. (0-31)
    b0, b1: Unit No. (0-3)
    b2-b7: MG No. 
    						