NDA-24307 CHAPTER 3 Page 173 Issue 1 SYSTEM MESSAGES [50H] Trunk Ineffective Hold Detected ➀ Detected Error Item ➁ LENS of Trunk Ineffective Hold (MG, U) ➂ LENS of Ineffective Hold Trunk (G, LV) 1: 50XX 00XX XXXX XXXX 2: XXXX XXXX XXXX XXXX 3: XXXX XXXX XXXX XXXX ➀ ➁ ➂ ➂ ➂ 4: XXXX XXXX XXXX XXXX 5: XXXX XX00 0000 0000 6: 0000 0000 0000 0000 ➂➂ 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000 b2 b1 b0 Group No. 1: 500X 00XX XXXX XXXX 2: XXXX XXXX XXXX XXXX 3: XXXX XXXX XXXX XXXX Group Number0➀ ➁ ➂ ➃ ➄ ➅ ➆ ➇ ➈ ➉11 1213 1415 1617 18 19 20 4: XXXX XXXX XXXX XXXX 5: XXXX XX00 0000 0000 6: 0000 0000 0000 0000 25 26 21 22 23 2427 28 29 30 31 7: 0000 0000 0000 0000 8: 000 0000 0000 0000 9: 0000 0000 0000 0000 Level b7 b6 b5 b4 b3 b2 b1 b0 G0 G1 G2 G3 G30 G31 [50H] Trunk Ineffective Hold Detected b1 b0 0 0 = Unit 0 0 1 = Unit 1 1 0 = Unit 2 1 1 = Unit 3 b2: 0/1 = Even No./Odd No. Module 0/1 = -/Ineffectively held

CHAPTER 3 NDA-24307 Page 174 Issue 1 SYSTEM MESSAGES [51H] Trunk Ineffective Hold Detected and Released ➀ Detected Error Item ➁ LENS of Trunk Ineffective Hold Detected and Released (MG, U) ➂ LENS of Ineffective Hold Trunk (G, LV) 1: 51XX 00XX XXXX XXXX 2: XXXX XXXX XXXX XXXX 3: XXXX XXXX XXXX XXXX ➀ ➁ ➂ ➂ ➂ 4: XXXX XXXX XXXX XXXX 5: XXXX XX00 0000 0000 6: 0000 0000 0000 0000 ➂➂ 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000 b2 b1 b0 Group No. 1: 500X 00XX XXXX XXXX 2: XXXX XXXX XXXX XXXX 3: XXXX XXXX XXXX XXXX Group Number➀ ➀ ➁ ➂ ➃ ➄ ➅ ➆ ➇ ➈ ➉11 1213 1415 1617 18 19 20 4: XXXX XXXX XXXX XXXX 5: XXXX XX00 0000 0000 6: 0000 0000 0000 0000 25 26 21 22 23 2427 28 29 3031 7: 0000 0000 0000 0000 8: 000 0000 0000 0000 9: 0000 0000 0000 0000 Level b7 b6 b5 b4 b3 b2 b1 b0 G0 G1 G2 G3 G30 G31 [51H] Trunk Ineffective Hold Detected and Released b1 b0 00 = Unit 0 01 = Unit 1 10 = Unit 2 11 = Unit 3 b2: 0/1 = Even No./Odd No. Module 0/1 = -/Ineffectively held

NDA-24307 CHAPTER 3 Page 175 Issue 1 SYSTEM MESSAGES [52H] Trunk Ineffective Hold Detected Impossible ➀ Detected Error Item ➁ Cause for the Suspended Detection 1: 5200 XX00 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000 ➀ ➁ 4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000 b1 b0 [52H] Trunk Ineffective Hold Detected Impossible b1 b0 0 1 = The CPU to detect is abnormal 1 0 = Data transfer error 1 1 = No Answer error

CHAPTER 3 NDA-24307 Page 176 Issue 1 SYSTEM MESSAGES [70H] Call Forwarding Memory Clear NG ➀ Detected Error Item ➁ Cause for which the Transfer Memory has been stopped 1: 7000 0X00 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000 ➀ ➁ 4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000 b1 b0 [70H] Call Forwarding Memory Clear NG b1 b0 0 1 = CPU is abnormal 1 0 = Data Transfer error

NDA-24307 CHAPTER 3 Page 177 Issue 1 SYSTEM MESSAGES [A0H] Periodic Backup Abnormal End ➀ Error detection by Routine Diagnosis ➁ Periodic Backup Abnormal End Information ➂ Backup Data to No. 0 system ➃ Error Code of No. 0 system HD Note:The Number Sharing data load also affects the data load of Dual Station Calling Over-FCCS. 1: A0XX XX00 XXXX XX00 2: XXXX XXXX XXXX XX00 3: 0000 0000 0000 0000 ➀ ➁ ➂ ➃ ➄ ➅ ➆ ➇ ➈ ➉ 4: 0000 0000 0000 0000 5: 0000 0000 0000 00006: 0000 0000 0000 0000 7: 0000 0000 0000 0000 8: 0000 0000 0000 00009: 0000 0000 0000 0000 b1 b0 b6 b5 b4 b3 b2 b1 b0 b7 b6 b5 b4 b3 b2 b1 b0 [A0H] Periodic Backup Abnormal End b0: 0/1 = HFD 0 Normal end/Abnormal end b1: 0/1 = HFD 1 Normal end/Abnormal end b0: 0/1 = -/Individual Speed Calling Data b1: 0/1 = -/Call Forwarding Data b2: 0/1 = -/RCF b3: 0/1 = -/Name Display Data b4: 0/1 = -/User Assign Soft Key Data b5: 0/1 = -/Number Sharing Data Note b6: 0/1 = -/Call Block Data 21H: 40H~47H: 53H: 57H: 59H~5BH: 80H~84H: A0H: A2H~A6H: BDH: C0H: Failed installation 01H: HD being used by another program 02H: HD not equipped Parameter HD Fault

CHAPTER 3 NDA-24307 Page 178 Issue 1 SYSTEM MESSAGES ➄ Error Status of No. 0 System HD ➅ Backup Data to No. 1 System ➆ Error Code of No. 1 System HD ➇ Error Status of No. 1 System HD ➈ [Data analyzed by NEC Engineers] ➉ [Data analyzed by NEC Engineers] b7 b3 b2 b1 b0 b7 b6 b5 b4 b3 b2 b1 b0 b7 b6 b5 b4 b3 b2 b1 b0 b7 b3 b2 b1 b0 Error occurs; b0: 0/1 = -/At the time data transfer started b1: 0/1 = -/At the time data saved b2: 0/1 = -/At the time data transfer ended b3: 0/1 = -/At the time file transfer started Refer to No. ➂ Refer to No.➃ Refer to No.➄

NDA-24307 CHAPTER 3 Page 179 Issue 1 SYSTEM MESSAGES [C0H] Detection of Remaining Link Abnormal End ➀ Performed Diagnosis Item ➁ Error Data 1: C000 XX00 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000 ➀ ➁ 4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000 b7 b6 b5 b4 b3 b2 b1 b0 b1 b0 [C0H] Detection of Remaining Link Abnormal End b1 b0 0 1 = CPU is not normal 1 0 = Data transfer error 1 1 = No Answer error

CHAPTER 3 NDA-24307 Page 180 Issue 1 SYSTEM MESSAGES This message displays when the MB switch on the PLO/CLK card is turned ON when extracting or inserting a circuit card . ➀ Switched PLO system 1: XX00 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000 ➀ 4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000 b0 Default Alarm: NON7-UPLO MB Key Turn ONDefault Grade: 3Grade Modified: Lamp Modified: b0: 0/1 = PLO No. 0 system/PLO No. 1 system

NDA-24307 CHAPTER 3 Page 181 Issue 1 SYSTEM MESSAGES This message displays when the MB switch on the PLO/CLK card has been turned off when extracting or inserting a circuit card . ➀ Switched PLO System ➁ Status of the PLO card at the time of the fault detection (Scan Data 1) Note:This information includes the failure detected in PH-CK18 (CLK) card. 1: XXXX XX00 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000 ➀ ➁ ➂ 4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000 b0 b7 b6 b5 b4 b3 b2 b1 b0 Default Alarm: NON7-VPLO MB Key Turn OFFDefault Grade: 3Grade Modified: Lamp Modified: b0: 0/1 = PLO No. 0 system/PLO No. 1 system b0: 0/1 = Clock STBY/ACT b1: 0/1 = PLO Synchronizing/PLO self-running or drifting b2: 0/1 = -/Input clock down b3, b4: Route of Input clock (see table) b5: 0/1 = -/PLO input all down b6: 0/1 = -/PLO output down Note b7: 0/1 = -/Drifting b4b3Connected With Primary Oscillator (M-OSC)Connected With External Clock 0 0 No. 0 M-OSC Route 0 0 1 No. 1 M-OSC Route 1 10 - Route 2 11 - Route 3

CHAPTER 3 NDA-24307 Page 182 Issue 1 SYSTEM MESSAGES ➂ Status of the PLO card at the time of the failure detection (Scan Data 2) b4 b1 b0b0: 0/1 = -/n × 5msec clock down b1: 0/1 = -/Frame Synchronization down from SYNC card b4: 0/1 = -/Internal OSC clock down