    							NDA-24307 CHAPTER 3
    Page 173
    Issue 1
    SYSTEM MESSAGES
    [50H] Trunk Ineffective Hold Detected 
    ➀ Detected Error Item
    ➁ LENS of Trunk Ineffective Hold 
    (MG, U)
    ➂ LENS of Ineffective Hold Trunk (G, LV)
    1: 50XX 00XX XXXX XXXX 2: XXXX XXXX XXXX XXXX 3: XXXX XXXX XXXX XXXX
    ➀ ➁ ➂ ➂
    ➂
    4: XXXX XXXX XXXX XXXX 5: XXXX XX00 0000 0000 6: 0000 0000 0000 0000
    ➂➂
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b2 b1 b0
    Group No.
    1: 500X 00XX XXXX XXXX 2: XXXX XXXX XXXX XXXX 3: XXXX XXXX XXXX XXXX
    Group 
    Number0➀ ➁ ➂ ➃ ➄ ➅ ➆ ➇ ➈ ➉11 1213 1415 1617 18 19 20
    4: XXXX XXXX XXXX XXXX 5: XXXX XX00 0000 0000 6: 0000 0000 0000 0000
    25 26 21 22 23 2427 28 29 30 31
    7: 0000 0000 0000 0000 8: 000 0000 0000 0000 9: 0000 0000 0000 0000
    
    Level
    b7 b6 b5 b4 b3 b2 b1 b0
    G0
    G1
    G2
    G3
    G30
    G31
    [50H] Trunk Ineffective Hold Detected
    b1
    b0
    0 0 = Unit 0
    0 1 = Unit 1
    1 0 = Unit 2
    1 1 = Unit 3
    b2: 0/1 = Even No./Odd No. Module
    0/1 = -/Ineffectively held 
    						
    							CHAPTER 3 NDA-24307
    Page 174
    Issue 1
    SYSTEM MESSAGES
    [51H] Trunk Ineffective Hold Detected and Released 
    ➀ Detected Error Item
    ➁ LENS of Trunk Ineffective Hold 
    Detected and Released (MG, U)
    ➂ LENS of Ineffective Hold Trunk (G, LV)
    1: 51XX 00XX XXXX XXXX 2: XXXX XXXX XXXX XXXX 3: XXXX XXXX XXXX XXXX
    ➀ ➁ ➂ ➂ ➂
    4: XXXX XXXX XXXX XXXX 5: XXXX XX00 0000 0000 6: 0000 0000 0000 0000
    ➂➂
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b2 b1 b0
    Group No.
    1: 500X 00XX XXXX XXXX 2: XXXX XXXX XXXX XXXX 3: XXXX XXXX XXXX XXXX
    Group 
    Number➀ ➀ ➁ ➂ ➃ ➄ ➅ ➆ ➇ ➈ ➉11 1213 1415 1617 18 19 20
    4: XXXX XXXX XXXX XXXX 5: XXXX XX00 0000 0000 6: 0000 0000 0000 0000
    25 26 21 22 23 2427 28 29 3031
    7: 0000 0000 0000 0000 8: 000 0000 0000 0000 9: 0000 0000 0000 0000
    
    Level
    b7 b6 b5 b4 b3 b2 b1 b0
    G0
    G1
    G2
    G3
    G30
    G31
    [51H] Trunk Ineffective Hold Detected and Released
    b1
    b0
    00 = Unit 0
    01 = Unit 1
    10 = Unit 2
    11 = Unit 3
    b2: 0/1 = Even No./Odd No. Module
    0/1 = -/Ineffectively held 
    						
    							NDA-24307 CHAPTER 3
    Page 175
    Issue 1
    SYSTEM MESSAGES
    [52H] Trunk Ineffective Hold Detected Impossible 
    ➀ Detected Error Item
    ➁ Cause for the Suspended Detection 
    1: 5200 XX00 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀ 
    ➁
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b1 b0
    [52H] Trunk Ineffective Hold Detected Impossible
    b1
    b0
    0 1 = The CPU to detect is abnormal
    1 0 = Data transfer error
    1 1 = No Answer error 
    						
    							CHAPTER 3 NDA-24307
    Page 176
    Issue 1
    SYSTEM MESSAGES
    [70H] Call Forwarding Memory Clear NG 
    ➀ Detected Error Item
    ➁ Cause for which the Transfer 
    Memory has been stopped
    1: 7000 0X00 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀ 
    ➁
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b1 b0
    [70H] Call Forwarding Memory Clear NG
    b1
    b0
    0 1 = CPU is abnormal
    1 0 = Data Transfer error 
    						
    							NDA-24307 CHAPTER 3
    Page 177
    Issue 1
    SYSTEM MESSAGES
    [A0H] Periodic Backup Abnormal End
    ➀ Error detection by Routine 
    Diagnosis
    ➁ Periodic Backup Abnormal End 
    Information
    ➂ Backup Data to No. 0 system
    ➃ Error Code of No. 0 system HD
    Note:The Number Sharing data load also affects the data load of Dual Station Calling Over-FCCS.
    1: A0XX XX00 XXXX XX00 2: XXXX XXXX XXXX XX00 3: 0000 0000 0000 0000
    ➀ ➁ ➂ ➃ ➄ ➅ ➆ ➇ ➈ ➉
    4: 0000 0000 0000 0000 5: 0000 0000 0000 00006: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 00009: 0000 0000 0000 0000
    b1 b0
    b6 b5 b4 b3 b2 b1 b0
    b7 b6 b5 b4 b3 b2 b1 b0
    [A0H] Periodic Backup Abnormal End
    b0: 0/1 = HFD 0 Normal end/Abnormal end
    b1: 0/1 = HFD 1 Normal end/Abnormal end
    b0: 0/1 = -/Individual Speed Calling Data
    b1: 0/1 = -/Call Forwarding Data
    b2: 0/1 = -/RCF
    b3: 0/1 = -/Name Display Data
    b4: 0/1 = -/User Assign Soft Key Data
    b5: 0/1 = -/Number Sharing Data Note
    b6: 0/1 = -/Call Block Data 
    21H:
    40H~47H:
    53H:
    57H:
    59H~5BH:
    80H~84H:
    A0H:
    A2H~A6H:
    BDH:
    C0H: Failed installation
    01H:  HD being used by another program
    02H: HD not equipped
    Parameter
    HD Fault 
    						
    							CHAPTER 3 NDA-24307
    Page 178
    Issue 1
    SYSTEM MESSAGES
    ➄ Error Status of No. 0 System HD
    ➅ Backup Data to No. 1 System
    ➆ Error Code of No. 1 System HD
    ➇ Error Status of No. 1 System HD
    ➈ [Data analyzed by NEC Engineers]
    ➉ [Data analyzed by NEC Engineers] b7 b3 b2 b1 b0
    b7 b6 b5 b4 b3 b2 b1 b0
    b7 b6 b5 b4 b3 b2 b1 b0
    b7 b3 b2 b1 b0
    Error occurs;
    b0: 0/1 = -/At the time data transfer started
    b1: 0/1 = -/At the time data saved
    b2: 0/1 = -/At the time data transfer ended
    b3: 0/1 = -/At the time file transfer started
    Refer to No. ➂
    Refer to No.➃
    Refer to No.➄ 
    						
    							NDA-24307 CHAPTER 3
    Page 179
    Issue 1
    SYSTEM MESSAGES
    [C0H] Detection of Remaining Link Abnormal End 
    ➀ Performed Diagnosis Item
    ➁ Error Data
    1: C000 XX00 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀  ➁
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b7 b6 b5 b4 b3 b2 b1 b0
    b1 b0
    [C0H] Detection of Remaining Link Abnormal End
    b1
    b0
    0 1 = CPU is not normal
    1 0 = Data transfer error
    1 1 = No Answer error 
    						
    							CHAPTER 3 NDA-24307
    Page 180
    Issue 1
    SYSTEM MESSAGES
    This message displays when the MB switch on the PLO/CLK card is turned ON when extracting or inserting
    a circuit card
    .
    ➀ Switched PLO system
    1: XX00 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀ 
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b0
    Default Alarm:
    NON7-UPLO MB Key Turn ONDefault Grade:
    3Grade Modified: Lamp Modified:
    b0: 0/1 = PLO No. 0 system/PLO No. 1 system 
    						
    							NDA-24307 CHAPTER 3
    Page 181
    Issue 1
    SYSTEM MESSAGES
    This message displays when the MB switch on the PLO/CLK card has been turned off when extracting or
    inserting a circuit card
    .
    ➀ Switched PLO System
    ➁ Status of the PLO card at the time 
    of the fault detection (Scan Data 1)
    Note:This information includes the failure detected in PH-CK18 (CLK) card.
    1: XXXX XX00 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀ ➁ ➂
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b0
    b7 b6 b5 b4 b3 b2 b1 b0
    Default Alarm:
    NON7-VPLO MB Key Turn OFFDefault Grade:
    3Grade Modified: Lamp Modified:
    b0: 0/1 = PLO No. 0 system/PLO No. 1 system
    b0: 0/1 = Clock STBY/ACT
    b1: 0/1 = PLO Synchronizing/PLO self-running or drifting
    b2: 0/1 = -/Input clock down
    b3, b4: Route of Input clock (see table)
    b5: 0/1 = -/PLO input all down
    b6: 0/1 = -/PLO output down Note
    b7: 0/1 = -/Drifting
    b4b3Connected With Primary 
    Oscillator (M-OSC)Connected With 
    External Clock
    0 0 No. 0 M-OSC Route 0
    0 1 No. 1 M-OSC Route 1
    10 - Route 2
    11 - Route 3 
    						
    							CHAPTER 3 NDA-24307
    Page 182
    Issue 1
    SYSTEM MESSAGES
    ➂ Status of the PLO card at the time 
    of the failure detection (Scan Data 
    2)
    b4 b1 b0b0: 0/1 = -/n × 5msec clock down
    b1: 0/1 = -/Frame Synchronization down from SYNC card
    b4: 0/1 = -/Internal OSC clock down  
    						