NDA-24307 CHAPTER 3 Page 153 Issue 1 SYSTEM MESSAGES [20H] Data Memory Verification Normal End ➀ Performed Diagnosis Item ➁ Verification of HD ➂ Verification of Data Memory 1: 20XX XX00 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000 ➀ ➁ ➂ 4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000 b1 b0 b2 b1 b0 [20H] Data Memory Verification Normal End b0: 0/1 = -/HFD 0 is normal b1: 0/1 = -/HFD 1 is normal b0: 0/1 = -/Data Memory b1: 0/1 = -/Local Data Memory b2: 0/1 = -/Network Data Memory
CHAPTER 3 NDA-24307 Page 154 Issue 1 SYSTEM MESSAGES [30H] TSW ACT/STBY Changeover Normal End ➀ Performed Diagnosis Item ➁ Active TSW system after the changeover 1: 30XX 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000 ➀ ➁ 4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000 b0 [30H] TSW ACT/STBY Changeover Normal End b0: 0/1 = TSW No. 0 is ACT/TSW No. 1 is ACT
NDA-24307 CHAPTER 3 Page 155 Issue 1 SYSTEM MESSAGES [40H] CPU ACT/STBY Changeover Normal End ➀ Performed Diagnosis Item ➁ Active status information after changeover 1: 40XX 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000 ➀ ➁ 4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000 b1 b0 [40H] CPU ACT/STBY Changeover Normal End b0: CPU 0/1 = No. 0 is ACT/No. 1 is ACT b1: TSW 0/1 = No. 0 is ACT/No. 1 is ACT
CHAPTER 3 NDA-24307 Page 156 Issue 1 SYSTEM MESSAGES [50H] No Trunk Ineffective Hold ➀ Performed Diagnosis Item ➁ MG and Unit of No. 1: 50XX 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000 ➀ ➁ 4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000 b7 b6 b5 b4 b3 b2 b1 b0 [50H] No Trunk Ineffective Hold b0: Unit 0, Even-numbered MG 1 = No Trunk Ineffective Hold b1: Unit 1, Even-numbered MG 1 = No Trunk Ineffective Hold b2: Unit 2, Even-numbered MG 1 = No Trunk Ineffective Hold b3: Unit 3, Even-numbered MG 1 = No Trunk Ineffective Hold b4: Unit 0, Odd-numbered MG 1 = No Trunk Ineffective Hold b5: Unit 1, Odd-numbered MG 1 = No Trunk Ineffective Hold b6: Unit 2, Odd-numbered MG 1 = No Trunk Ineffective Hold b7: Unit 3, Odd-numbered MG 1 = No Trunk Ineffective Hold
NDA-24307 CHAPTER 3 Page 157 Issue 1 SYSTEM MESSAGES [70H] Call Forwarding Memory Clear Normal End ➀ Performed Diagnosis Item 1: 7000 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000 ➀ 4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000 [70H] Call Forwarding Memory Clear Normal End
CHAPTER 3 NDA-24307 Page 158 Issue 1 SYSTEM MESSAGES [A0H] Periodic Back-up Normal ➀ Performed Diagnosis Item ➁ Information on Periodic Backup Normal End ➂ Backup Data to No. 0 system ➃Backup Data to No. 1 system Note:The Number Sharing data load also affects the data load of Dual Station Calling Over-FCCS. 1: A0XX XX00 0000 XX00 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000 ➀ ➁ ➂ ➃ 4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000 b1 b0 b6 b5 b4 b3 b2 b1 b0 b6 b5 b4 b3 b2 b1 b0 [A0H] Periodic Back-up Normal b0: 0/1 = HFD 0 Normal end/Abnormal end b1: 0/1 = HFD 1 Normal end/Abnormal end b0: 0/1 = -/Individual Speed Calling Data b1: 0/1 = -/Call Forwarding Data b2: 0/1 = -/RCF b3: 0/1 = -/Name Display Data b4: 0/1 = -/User Assign Soft Key Data b5: 0/1 = -/Number Sharing Data Note b6: 0/1 = -/Call Block Data b0: 0/1 = -/Individual Speed Calling Data b1: 0/1 = -/Call Forwarding Data b2: 0/1 = -/RCF b3: 0/1 = -/Name Display Data b4: 0/1 = -/User Assign Soft Key Data b5: 0/1 = -/Number Sharing Data Note b6: 0/1 = -/Call Block Data
NDA-24307 CHAPTER 3 Page 159 Issue 1 SYSTEM MESSAGES [C0H] Detection of Remaining Link Normal End ➀ Performed Diagnosis Item 1: C000 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000 ➀ 4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000 b7 b6 b5 b4 b3 b2 b1 b0 [C0H] Detection of Remaining Link Normal End
CHAPTER 3 NDA-24307 Page 160 Issue 1 SYSTEM MESSAGES In a specific time cycle, the system allows a routine diagnosis in its hardware and software to determine if they are operating properly. This message indicates that the system has been checked by the routine diagnosis program and the result of the diagnosis is not normal. ➀ Detected Error Item Note 1:This data is output at the ISW. Note 2:This data is collected and output at the ISW. Note 3:The data in this area will be diverse, according to the diagnosis specified in ➀. For details on each item data, see the following pages. 1: XXXX XXXX XXXX XXXX 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000 Note 3 ➀ 4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000 b7 b6 b5 b4 b3 b2 b1 b0 Default Alarm: NON7-PCyclic Diagnosis Information (Error Detected)Default Grade: 3Grade Modified: Lamp Modified: [10H] Program Memory Verification Discrepancy [11H] Program Memory Verification Impossible (HFD Fault) [12H] Program Memory Verification Impossible (Fault at CPU side) [20H] Data Memory Verification Discrepancy [21H] Data Memory Verification Impossible (HFD Fault) [31H] TSW ACT/STBY Changeover Failure (ISW) [32H] TSW ACT/STBY Changeover Failure (LN) [41H] CPU ACT/STBY Changeover Failure [42H] CPU ACT/STBY Changeover Failure (DM or PM Verification NG) [43H] CPU ACT/STBY Changeover Failure (PCI Fault) [44H] CPU ACT/STBY Changeover Failure (Changeover NG or CPU RAM Copy NG) [50H] Trunk Ineffective Hold Detected [51H] Trunk Ineffective Hold Detected and Released [52H] Trunk Ineffective Hold Detected Impossible [70H] Call Forwarding Memory Clear NG [A0H] Periodic Backup Abnormal End [C0H] Detection of Remaining Link Abnormal End
NDA-24307 CHAPTER 3 Page 161 Issue 1 SYSTEM MESSAGES [10H] Program Memory Verification Discrepancy ➀ Detected Error Item ➁ Faulty HFD number ➂ Verification of Drive Number ➃ Data analyzed by NEC Engineers 1: 1000 XXXX XXXX XXXX 2: XXXX 0000 0000 0000 3: 0000 0000 0000 0000 ➀ ➁ ➂ ➃ 4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000 b1 b0 b3 b2 b1 b0 [10H] Program Memory Verification Discrepancy b0: 0/1 = -/HFD 0 b1: 0/1 = -/HFD 1 b0: 0/1 = -/Drive Number 0 b1: 0/1 = -/Drive Number 1 b2: 0/1 = -/Drive Number 2 b3: 0/1 = -/Drive Number 3
CHAPTER 3 NDA-24307 Page 162 Issue 1 SYSTEM MESSAGES [11H] Program Memory Verification Impossible (HFD Fault) ➀ Detected Error Item ➁ HFD No. (verification suspended) ➂ Error Type ➃ Data analyzed by NEC Engineers ➄ Error Drive Note Note: This data is available when ➂ is 00 Hex. 1: 11XX XXXX XXXX 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000 ➀ ➁ ➂ ➃➄ 4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000 b1 b0 b7 b6 b5 b4 b3 b2 b1 b0 b3 b2 b1 b0 [11H] Program Memory Verification Impossible (HFD Fault) b0: 0/1 = -/HFD 0 b1: 0/1 = -/HFD 1 00H: HD Processing NG 01H: HD Not Connected 02H: HD Busy 03H: HD Fault (Fault processing/No equipment, etc.) 04H: Transfer NG 05H: Response Timeout b0: 0/1 = -/Drive Number 0 b1: 0/1 = -/Drive Number 1 b2: 0/1 = -/Drive Number 2 b3: 0/1 = -/Drive Number 3