    							NDA-24307 CHAPTER 5
    Page 423
    Issue 1
    FAULT REPAIR PROCEDURES
    8.3 Fault That Cannot Be Detected
    Check the DSP flat cable (See Figure 5-13.).
    If the EMA card is removed from the system while the system is in operation under
    the control of the CPU 1, the system will reset and stop all call processing. See Section
    1.3.2, EMA Card Replacement Procedure, Chapter 4 for detailed instructions.
    Replace the EMA circuit card with a spare.
    Set the MB switch of the EMA circuit card UP, and extract the circuit card from its
    mounting slot.
    Make necessary switch settings on the new circuit card, referring to the card extracted.
    Set MB switch UP and insert the circuit card into its mounting slot.
    Set the MB switch DOWN.
    Check to see if a fault is detected.
    ATTENTIONContents
    Static Sensitive
    Handling
    Precautions Required
    START
    END
    WA RN I NG 
    						
    							CHAPTER 5 NDA-24307
    Page 424
    Issue 1
    FAULT REPAIR PROCEDURES
    9. POWER SUPPLY FAULT
    This section explains the fault repair procedure when any of the faults shown in Table 5-12 occur.
    9.1 Check Point
    When repairing a power supply fault, consider the following items:
    (1) Before checking the system, check the rectifier, battery, and power cables.
    (2) The PWR circuit card is equipped with the circuits to supply ringing signal and howler tone. When a fault
    occurs that causes the bell of the telephone not to ring, or howler tone cannot be heard, etc., check the
    alarm lamp on the PWR circuit card.
    (3)Figure 5-14 through Figure 5-17 show the block diagrams for the power supply to each module.
    Figure 5-14   Block Diagram of Power Supply System (ISW)Table 5-12  PWR Supply Fault Situation
    FAULTY SITUATION REFERENCE SECTION
    Fuse Blown FaultSection 9.2, Fuse Blown Fault
    Circuit Breaker OFF, Fault in PWR SupplySection 9.3, Circuit Breaker OFF Fault in PWR Supply
    Fault of Alarm Lamps on PWR SupplySection 9.4, Fault of Alarm Lamps on PWR Supply
    Note:PWR1 is mounted when power supply system is a dual system configuration.
    ISWMPWR
    0
    PWR
    1
    Note
    LPMPWR
    0
    PWR
    1MISC
    Note
    EMAIOCCPUISAGT0
    ISW
    BASEU
    LANI0
    HSW00HSW01TSW00TSW01TSW02TSW03IOGT0PLO0 
    						
    							NDA-24307 CHAPTER 5
    Page 425
    Issue 1
    FAULT REPAIR PROCEDURES
    Figure 5-15   Block Diagram of Power Supply System (IMG0)
    Note:PWR1 is mounted when power supply system is a dual system configuration. 
    PWR
    0
    PWR
    1LC/TRKLC/TRKMUX0MUX1LC/TRKLC/TRK
    PIM3
    Note
    PWR
    0
    PWR
    1LC/TRKLC/TRKMUX0MUX1LC/TRKLC/TRK
    PIM2
    Note
    PWR
    0
    PWR
    1LC/TRKLC/TRKMUX0MUX1LC/TRKLC/TRK
    PIM1
    Note
    PWR
    0
    PWR
    1LC/TRKLC/TRKMUX0MUX1LC/TRKLC/TRK
    PIM0
    Note
    PWR
    0
    PWR
    1
    LPM
    Note
    CPU0MISC
    BASEUIMG1/2 (LN0/1/2/3)
    LANI0ISAGT-0BISAFT-0AIOCEMA 
    						
    							CHAPTER 5 NDA-24307
    Page 426
    Issue 1
    FAULT REPAIR PROCEDURES
    Figure 5-16   Block Diagram of Power Supply System (IMG1/IMG2)
    PWR
    0
    PWR
    1LC/TRKLC/TRKMUX0MUX1LC/TRKLC/TRK
    PIM3
    Note
    PWR
    0
    PWR
    1LC/TRKLC/TRKMUX0MUX1LC/TRKLC/TRK
    PIM2
    Note
    PWR
    0
    PWR
    1LC/TRKLC/TRKMUX0MUX1LC/TRKLC/TRK
    PIM1
    Note
    PWR
    0
    PWR
    1LC/TRKLC/TRKMUX0MUX1LC/TRKLC/TRK
    PIM0
    Note
    PWR
    0
    PWR
    1MISC
    LPM
    Note
    DLKC0PLO0/CLK0
    BASEUIMG1/2 (LN0/1/2/3)
    TSW03TSW02TSW01TSW00GT0
    Note 1:PWR1 is mounted when power supply system is a dual system configuration. 
    Note 2:DLKC is not mounted in TSWM1 of IMG2.
    Note 3:PLO for IMG1 (TSWM0); CLK for IMG2 (TSWM1) 
    						
    							NDA-24307 CHAPTER 5
    Page 427
    Issue 1
    FAULT REPAIR PROCEDURES
    Figure 5-17   Block Diagram of Power Supply System (IMG3)
    Note:PWR1 is mounted when power supply system is a dual system configuration. 
    PWR
    0
    PWR
    1LC/TRKLC/TRKMUX0MUX1LC/TRKLC/TRK
    PIM3
    Note
    PWR
    0
    PWR
    1LC/TRKLC/TRKMUX0MUX1LC/TRKLC/TRK
    PIM2
    Note
    PWR
    0
    PWR
    1LC/TRKLC/TRKMUX0MUX1LC/TRKLC/TRK
    PIM1
    Note
    PWR
    0
    PWR
    1LC/TRKLC/TRKMUX0MUX1LC/TRKLC/TRK
    PIM0
    Note
    DUMMY
    BASEUIMG3 (LN0/1/2/3) 
    						
    							CHAPTER 5 NDA-24307
    Page 428
    Issue 1
    FAULT REPAIR PROCEDURES
    (4)Figure 5-18 shows the power supply system for PIM.
    Figure 5-18   Power Supply to PIM
    (5)Figure 5-19 shows the power supply system for LPM.
    Figure 5-19   Power Supply to LPM (LN/ISW)
    DC-DC
    CONV
    RGU
    HOW
    -48V
    NFB
    +80V
    relRGU
    REL PWR0
    -48V +80V   Note 
    +5V, +12V, 5V
    CR (for LC)
    HOW (for LC)
    -48V (for LC, TRK)
    +80V
    +80V -48V  DC-DC
    CONV
    RGU
    HOW
    -48 V
    NFB
    +80 V
    relREL PWR1
    Note:+80V is for message waiting lamp.
    +5V,+12V
    (To EMA, MISC, Cards, etc.)
    -48V
    (To EMA, MISC, Cards, etc.)PWR1 PWR0
    DC-DC
    CONV DC-DC
    CONV
    -48V
    +80VREL REL
    -48V
    +80V (To CPR 0)
    -48V (To CPR 1)
    -48V 
    						
    							NDA-24307 CHAPTER 5
    Page 429
    Issue 1
    FAULT REPAIR PROCEDURES
    (6)Figure 5-20 shows the power supply system for TSWM/ISWM.
    Figure 5-20   Power Supply to TSWM/ISWM
    +5V, +12V, +5V
    (To MISC Cards)
    -48VPWR1 PWR0
    DC-DC
    CONV DC-DC
    CONV
    -48V
    +80VREL REL
    -48V
    +80V -48V -48V
    [TSWM]
    To GT, TSW, DLKC, PLO cards
    [ISWM]
    To IOGT, TSW, HSW, PLO cards 
    						
    							CHAPTER 5 NDA-24307
    Page 430
    Issue 1
    FAULT REPAIR PROCEDURES
    9.2 Fuse Blown Fault
    Check the backplane of the PIM. Make a visual check on the backplane for pin
    contacting, melting or burn, etc.
    Extract all the circuit cards from the PIM,
    and insert them back into their slots
    individually to see if the fuse blows.Set the MB switch of the PWR supply UP.
    Set the circuit breaker of the PWR supply
    DOWN.
    Extract all the circuit cards from their mounting
    slots, except PWR supply.
    Replace the fuse with spare.
    Set the circuit breaker of the PWR supply UP
    side.
    Set the MB switch of the PWR supply DOWN.
    Insert the circuit cards into their mounting slots
    individually, with their MB switch to UP side.
    Check to see if the fuse blows when the MB
    switch has been set to DOWN. START
    END 
    						
    							NDA-24307 CHAPTER 5
    Page 431
    Issue 1
    FAULT REPAIR PROCEDURES
    9.3 Circuit Breaker OFF Fault in PWR Supply
    Check the backplane of the PIM. Make a visual check on the backplane for pin
    contacting, melting or burning, etc.
    Extract all the circuit cards from the PIM, 
    and make a visual check of the circuit 
    cards.Set MB switch of the PWR supply UP.
    Set the circuit breaker of the PWR supply
    DOWN.
    Extract all circuit cards out of their mounting
    slots.
    Make a visual check of the extracted circuit
    cards. 
    Check ICs, resistors, and capacitors to see if 
    any are burned. START
    END 
    						
    							CHAPTER 5 NDA-24307
    Page 432
    Issue 1
    FAULT REPAIR PROCEDURES
    9.4 Fault of Alarm Lamps on PWR Supply
    Note:Insert each PWR supply with its MB switch to UP side, and then set it back to DOWN side. Press RESET button of the PWR supply.
    Alarm lamp goes out.FA U LT  S U P E RV I S I O N
    Alarm lamp illuminates again. Set the MB switch on the PWR supply UP.
    Turn circuit breaker OFF.
    Set MB switch on all the circuit cards, except
    PWR supply.
    Extract all circuit cards from their mounting
    slots.
    Turn circuit breaker ON.
    Set the MB switch to DOWN side.
    Check to see if the alarm lamp illuminates.
    If the alarm lamp illuminates,
    replace the PWR supply with a
    spare.
    If the alarm lamp does not
    illuminate, insert the circuit cards
    into their mounting slot
    individually to see if the alarm
    lamp illuminates. START
    END 
    						