Home > NEC > Communications System > NEC Neax 2400 Ipx System Operations And Maintenance Manual

NEC Neax 2400 Ipx System Operations And Maintenance Manual

    Download as PDF Print this page Share this page

    Have a look at the manual NEC Neax 2400 Ipx System Operations And Maintenance Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 1168 NEC manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    Page
    of 724
    							NDA-24307 CHAPTER 8
    Page 663
    Issue 1
    DTF601N: Display of Connection Route Peg Count Data for Fusion Network
    DTF601N:Display of Connection Route Peg Count Data for Fusion Network
    1. Functional Outline
    This command displays the result of traffic measurement data for Type=18 (Connection Route Peg Count)
    assigned by the ATRFN command.
    2. Parameters
    Traffic Data 1: Terminal Traffic-DTF101N
    Route Traffic-DTF102N
    Station Peg Count-DTF103N
    Attendant Peg Count-DTF104N
    Route Peg Count-DTF105N
    Traffic Data 2:  Service Peg Count-DTF201N
    Traffic Data 3: UCD Route Peg Count-DTF301N
    UCD Group Peg Count-DTF302N
    UCD Station Peg Count-DTF303N
    Traffic Data 5: Attendant Answering Peg Count-DTF501N
    Traffic Data 6: Connection Route Peg Count-DTF601N
    Connection Route Traffic-DTF602N 
    						
    							CHAPTER 8 NDA-24307
    Page 664
    Issue 1
    DTF602N: Display of Connection Route Traffic Data for Fusion Network
    DTF602N:Display of Connection Route Traffic Data for Fusion Network
    1. Functional Outline
    This command displays the result of traffic measurement data for Type=19 (Connection Route Traffic)
    assigned by the ATRFN command.
    2. Parameters
    Traffic Data 1: Terminal Traffic-DTF101N
    Route Traffic-DTF102N
    Station Peg Count-DTF103N
    Attendant Peg Count-DTF104N
    Route Peg Count-DTF105N
    Traffic Data 2: Service Peg Count-DTF201N
    Traffic Data 3: UCD Route Peg Count-DTF301N
    UCD Group Peg Count-DTF302N
    UCD Station Peg Count-DTF303N
    Traffic Data 5: Attendant Answering Peg Count-DTF501N
    Traffic Data 6: Connection Route Peg Count-DTF601N
    Connection Route Traffic-DTF602N 
    						
    							NDA-24307 CHAPTER 8
    Page 665
    Issue 1
    FLINST: File Install
    FLINST:File Install
    1. Functional Outline
    This command is used to install the DPSW-dedicated database files to your MAT. This command is necessary
    to provide each circuit card’s various information (such as circuit card name, equipped switch names, etc.)
    when your system uses the DPSW/DPKG command.
    2. Parameters
    Input data
    None
    Buttons
    Copy: Click to start the data file install.
    Exit: Click to exit this command.
    
    (1) Start up the FLINST command from the Start menu.
    (2) Initial Display of the FLINST command appears. Make sure the proper FD drive name is selected in the
    “FDD” parameter.
    (3) Click the “Copy” button. Then, a message, requiring to insert the first FD into the FDD drive, appears.
    (4) Insert the first FD into the FDD of the MAT. Then, click OK.
    (5) File copy starts automatically, and the “Copy End” message appears upon completion.
    (6) Click OK. Then, another message asks you whether the next FD is to be installed or not.
    (7) Click OK.
    (8) A message, requiring to insert the second FD into the FDD drive, appears. Insert the second FD into the
    FDD, and click OK.
    (9) File copy starts automatically, and the “Copy End” message appears upon completion.
    (10) Click OK. Then, a message asks you whether the next (fourth) FD is to be installed or not.
    (11) Click Cancel. 
    						
    							CHAPTER 8 NDA-24307
    Page 666
    Issue 1
    HDD_FDD: Data Control Between HDD and FDD
    HDD_FDD:Data Control Between HDD and FDD
    1. Functional Outline
    This command is used to install the program data from FDD of PBX to HDD of PBX, and to verify the program
    data between FDD of PBX and HDD of PBX.
    2. Parameters
    Input data
    System Select:  HFD 0/HFD 1
    Direction Select:  Floppy Disk to Hard Disk/Verify HDD against FDD/Hard Disk to Floppy Disk
    Data Type Selection: Data Memory
    Note 1
    Name Display
    Wireless Call Forwarding
    Program data
    Note 2
    Call Forwarding
    Speed Calling
    User Assign Soft Key
    Number Sharing
    Note 3
    Call Block 
    ACD Data Memory
    LP Select: This data appears when Call Forwarding, Speed Calling, User Assign Soft Key,
    Number Sharing, or Call Block data is designated.
    File Name Select
    Auto Verify Afterward
    Note 1:When “Data Memory” is selected, Local Data Memory (LDM) and Network Data Memory (NDM)
    are also saved/verifed simultaneously.
    Note 2:“Program data” can be valid when you select “Floppy Disk to Hard Disk” or Verify HDD against
    FDD” in the “Direction Select” list box.
    Note 3:By saving the Number Sharing data, the data concering “Dual Station Calling Over-FCCS” is also
    saved/verifed automatically. 
    						
    							NDA-24307 CHAPTER 8
    Page 667
    Issue 1
    HDD_MAT: Data Control Between HDD and MAT
    HDD_MAT:Data Control Between HDD and MAT
    1. Functional Outline
    This command is used to save the following data from HDD of PBX to MAT.
    2. Parameters
    Input data
    Direction Select: PBX Hard Disk to MAT/MAT to PBX Hard Disk/Verify HDD against MAT
    Data Type Selection: Data Memory
    Note 1
    Name display
    Wireless Call Forwarding
    Program data
    Note 2
    Call Forwarding
    Speed Calling
    User Assign Soft Key
    Number Sharing
    Note 3
    Call Block 
    ACD Data Memory
    LP Select: This data appears only when Call Forwarding, Speed Calling, User Assign Soft
    Key, Number Sharing, or Call Block data is designated.
    Auto Verify Afterward
    Note 1:When “Data Memory” is selected, Local Data Memory (LDM) and Network Data Memory (NDM)
    are also saved/verifed simultaneously.
    Note 2:“Program data” can be valid when you select “MAT to PBX Hard Disk” in the “Direction Select”
    list box.
    Note 3:By saving the Number Sharing data, the data concering “Dual Station Calling Over-FCCS” is also
    saved/verifed automatically. 
    						
    							CHAPTER 8 NDA-24307
    Page 668
    Issue 1
    HDD_MAT_N: Data Control Between HDD and MAT for NDM
    HDD_MAT_N:Data Control Between HDD and MAT for NDM
    1. Functional Outline
    This command, available at the NCN only, installs (overwrites) the updated Program data from the centralized
    MAT onto the HDD of all local nodes. To use this command, first install the updated program data on the HDD
    of the MAT and then execute the program installing onto the HDD of each LN.
    2. Parameters
    Input data
    Data Type Selection:  Select all the listed program data
    Execution Button:  Installing of program data is to be executed 
    						
    							NDA-24307 CHAPTER 8
    Page 669
    Issue 1
    HDFP: HDD Format of PBX
    HDFP:HDD Format of PBX
    1. Functional Outline
    This command is used to execute the formatting of the HDD of PBX.
    2. Parameters
    Input data (Selection by check)
    0 System: HDD of No.0 System
    1 System: HDD of No.1 System
    Buttons
    Execute: Click to execute the formatting.
    Close: Click to exit this command. 
    						
    							CHAPTER 8 NDA-24307
    Page 670
    Issue 1
    MBCT: Make Busy of Connection Trunk for LDM
    MBCT:Make Busy of Connection Trunk for LDM
    1. Functional Outline
    This command is used to set/reset the make busy state of the connection trunk.
    2. Parameters
    Input data
    C_RT: Connection Route Number [1-1023]
    C_TK: Trunk Number [1-4095]
    MB: Make Busy Information [0/1]
    0=Make Idle
    1=Make Busy (Outgoing) 
    						
    							NDA-24307 CHAPTER 8
    Page 671
    Issue 1
    MBLE: Make Busy of LENS
    MBLE:Make Busy of LENS
    1. Functional Outline
    This command assigns the Idle/Busy status of Line Equipment Numbers (LENS).
    2. Parameters
    Input data
    LENS
    MB: 0/1=Make Idle/Make Busy 
    						
    							CHAPTER 8 NDA-24307
    Page 672
    Issue 1
    MBPM: Make Busy of Port Microprocessor
    MBPM:Make Busy of Port Microprocessor
    1. Functional Outline
    This command sets or resets the make-busy state of the circuit card that contains the port microprocessor. This
    setting and resetting is performed individually for each circuit card. If the location of the circuit card containing
    the port microprocessor is specified in this command, the operating state of all circuit cards mounted in the
    associated unit is displayed.
    2. Parameters
    Input data
    MG
    Unit
    Group
    MB
    Display data
    MB: (0-1)
    0=Make Idle
    1=Make Busy
    Note:The Idle/Busy status can be displayed and assigned by the MB parameter. 
    						
    All NEC manuals Comments (0)