NDA-24307 CHAPTER 3 Page 133 Issue 1 SYSTEM MESSAGES This message displays when the SMDR output buffer usage rate has exceeded the value assigned to ASYD, SYS1, INDEX249. ➀ Detail Information (a) FS = 0, FE = 0/1 ➁ 1: XXXX XXXX 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000 ➀ ➁ ➂ ➃ 4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000 b7 b6 b5 b4 b3 b2 b1 b0 b0 Default Alarm: SUP6-OSMDR Output Buffer Overflow AlarmDefault Grade: 1Grade Modified: Lamp Modified: b0-b3: FS b4-b7: FE This system message varies depending on the data at ➀. FSFEMEANING (a) 0 0 SMDR output buffer usage rate exceeds the value assigned by ASYD, SYS1, INDEX249. (a) 0 1 After SMDR output buffer usage rate exceeds the value assigned by ASYD, SYS1, INDEX249, usage rate lowered less than the value assigned by INDEX250. (b) 1 0 - (c) 2 0 Data output is impossible due to SMDR apparatus failure. b0: 0/1 = Data assigned by the ASYD, SYS1, INDEX249, 250 is valid/ invalid

CHAPTER 3 NDA-24307 Page 134 Issue 1 SYSTEM MESSAGES ➂ Buffer Usage Rate Assigned by ASYD, SYS1, INDEX249 ➃ Buffer Usage Rate Assigned by ASYD, SYS1, INDEX250 (b) FS = 1, FE = 0 ➁ ➂ Overflow Rate ➃ Overflow Rate b7 b6 b5 b4 b3 b2 b1 b0 b7 b6 b5 b4 b3 b2 b1 b0 b1 b0 b0 b7 b6 b5 b4 b0-b3: Units b4-b7: Tens b0-b3: Units b4-b7: Tens b0, b1: Fault Grade by ALMG command 00 = NON CONT 01 = SUP 10 = MN 11 = MJ b0: 0/1 = -/100% Overflow b4-b7: 1-9 = 10%-90% Overflow

NDA-24307 CHAPTER 3 Page 135 Issue 1 SYSTEM MESSAGES (c) FS = 2, FE = 0 ➁ SMDR Group No. ➂ Port No. ➃ Not used (d) FS = 3, FE = 0 ➁ b3 b2 b1 b0 b7 b6 b5 b4 b3 b2 b1 b0 b3 b2 b1 b0 b0-b3: SMDR Group No. to which failure occurred b0-b7: Port No. allocated for SMDR Group to which failure occurred (0-7) b0-b3: SMDR Group No. to which failure occurred

CHAPTER 3 NDA-24307 Page 136 Issue 1 SYSTEM MESSAGES This message displays when the SMDR output buffer usage rate has been lowered to less than the value assigned in the ASYD, SYS1, INDEX250 after the rate exceeds the value assigned by INDEX249. ➀ Detail Information 1: XX00 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000 ➀ 4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000 b7 b6 b5 b4 b3 b2 b1 b0 Default Alarm: NON6-PSMDR Output Buffer Overflow ReleaseDefault Grade: 0Grade Modified: Lamp Modified: b0-b7: 00H = After SMDR output buffer usage rate exceeds the value assigned by ASYD, SYS1, INDEX249, the rate lowered less than the value assigned by INDEX250.

NDA-24307 CHAPTER 3 Page 137 Issue 1 SYSTEM MESSAGES This message displays after the office data is loaded and system initialization has executed. ➀ ➁ Load Status 1: XXXX XX00 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000 ➀ ➁ 4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000 b4 b3 b2 b1 b0 b7 b6 b5 b4 b3 b2 b1 b0 b11 b9 b8 Default Alarm: NON7-ASystem Initialize With Data LoadDefault Grade: 3Grade Modified: Lamp Modified: b0: 0/1 = IPL/PWR ON b1: 0/1 = Load Key OFF/ON b2: 0/1 = IPL KEY/MAT INITIAL b3: 0/1 = Program load is executed/- b4: 0/1 = -/Phase1 Restart Note 1 b0: Office Data Load Status 0/1 = Load OK/NG b1: Call Forwarding Data Load Status 0/1 = Load OK/NG b2: Individual Speed Calling Data Load Status 0/1 = Load OK/NG b3: RCF Data Load Status 0/1 = Load OK/NG b4: Name Display Data Load Status 0/1 = Load OK/NG b5: Network DM Load Status 0/1 = Load OK/NG b6: Local DM Load Status 0/1 = Load OK/NG b7: 0/1 = DM Load/Non Load b8: User assign Soft Key Data Load Status 0/1 = Load OK/NG b9: Number Sharing Data Load Status 0/1 = Load OK/NG Note 2 b11: Call Block Data Load Status 0/1 = Load OK/NG

CHAPTER 3 NDA-24307 Page 138 Issue 1 SYSTEM MESSAGES Note 1: Phase 1 Restart is executed when initializing the system without disrupting the following two-way connections that have already been established: Basic two-way connections (STN-STN, STN-TRK, TRK-TRK) Fixed connections Two-way connections established on a Fusion link Note 2:The Number Sharing data load also affects the data load of Dual Station Calling Over-FCCS . For more details, see Chapter 6, Section 12.

NDA-24307 CHAPTER 3 Page 139 Issue 1 SYSTEM MESSAGES This message displays when system initialization is activated. ➀ ➁ Details on Intialization Note 2 ➂ FPC No. Note 2 Note 1: Phase 1 Restart is executed when initializing the system without disrupting the following two-way connections that have already been established: Basic two-way connections (STN-STN, STN-TRK, TRK-TRK) Fixed connections Two-way connections established on a Fusion link Note 2:When the whole system is initialized via key information from the ISW, this message is output in each LN/ISW. However, the data ➁ and ➂ are displayed at the ISW only. For more details, see Chapter 6, Section 12. 1: XX00 XX00 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000 ➀ ➁ ➂ 4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000 b4 b3 b2 b1 b0 b7 b6 b5 b4 b3 b2 b1 b0 Default Alarm: NON7-BSystem InitializeDefault Grade: 3Grade Modified: Lamp Modified: b2: 0/1 = IPL KEY/MAT INITIAL b3: 0/1 = Program Load/Non Load b4: 0/1 = -/Phase1 Restart Note 1 b0: 0/1 = -/ISW → LN Remote Initialization Request b1: 0/1 = -/ISW → LN Data Sending Error b0-b7: FPC No. of LN where initialization request sent

CHAPTER 3 NDA-24307 Page 140 Issue 1 SYSTEM MESSAGES This message displays when the MBR switch on the CPU Front Panel has been turned ON at the time of CPU changeover or speech path changeover. ➀ Self-CPU Restart Information ➁ Mate-CPU Restart Information 1: XXXX 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000 ➀ ➁ 4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000 b7 b5 b4 b3 b0 b7 b5 b4 b3 b0 Default Alarm: NON7-CCPU MBR Key Turn ONDefault Grade: 3Grade Modified: Lamp Modified: b0: 0/1 = -/Monitor Restart b3: 0/1 = -/Initialization b4: 0/1 = -/Data Copy Restart (for Dual-CPU system only) b5: 0/1 = -/MB control b7: 0/1 = ACT/STBY (active system indication after restart) b0: 0/1 = -/Monitor Restart b3: 0/1 = -/Initialization b4: 0/1 = -/Data Copy Restart (for Dual-CPU system only) b5: 0/1 = -/MB control b7: 0/1 = ACT/STBY (active system indication after restart)

NDA-24307 CHAPTER 3 Page 141 Issue 1 SYSTEM MESSAGES This message displays when the MBR switch on the CPU Front Panel has been turned OFF at the time of CPU changeover or speech path changeover. ➀ Self-CPU Restart Information ➁ Mate-CPU Restart Information 1: XXXX 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000 ➀ ➁ 4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000 b7 b5 b4 b3 b0 b7 b5 b4 b3 b0 Default Alarm: NON7-DCPU MBR Key Turn OFFDefault Grade: 3Grade Modified: Lamp Modified: b0: 0/1 = -/Monitor Restart b3: 0/1 = -/Initialization b4: 0/1 = -/Data Copy Restart (for Dual-CPU system only) b5: 0/1 = -/MB control b7: 0/1 = ACT/STBY (active system indication after restart) b0: 0/1 = -/Monitor Restart b3: 0/1 = -/Initialization b4: 0/1 = -/Data Copy Restart (for Dual-CPU system only) b5: 0/1 = -/MB control b7: 0/1 = ACT/STBY (active system indication after restart)

CHAPTER 3 NDA-24307 Page 142 Issue 1 SYSTEM MESSAGES This message displays when the MBR switch on the TSW card has been turned ON at CPU changeover or speech path changeover. ➀ System Status of TSW Card 1: XX00 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000 ➀ 4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000 b7 b0 Default Alarm: NON7-ETSW MBR Key Turn ONDefault Grade: 3Grade Modified: Lamp Modified: b0: 0/1 = No. 0 system/No. 1 system b7: Kind of PKG 0/1 = SW12/GT09