    							NDA-24307 CHAPTER 3
    Page 133
    Issue 1
    SYSTEM MESSAGES
    This message displays when the SMDR output buffer usage rate has exceeded the value assigned to ASYD,
    SYS1, INDEX249.
    ➀ Detail Information
    (a) FS = 0, FE = 0/1
    ➁
    1: XXXX XXXX 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀ ➁ ➂ ➃
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b7 b6 b5 b4 b3 b2 b1 b0
    b0
    Default Alarm:
    SUP6-OSMDR Output Buffer Overflow AlarmDefault Grade:
    1Grade Modified: Lamp Modified:
    b0-b3: FS
    b4-b7: FE
    This system message varies depending on the data at 
    ➀.
    FSFEMEANING
    (a) 0 0 SMDR output buffer usage rate exceeds the value 
    assigned by ASYD, SYS1, INDEX249.
    (a) 0 1 After SMDR output buffer usage rate exceeds the 
    value assigned by ASYD, SYS1, INDEX249, 
    usage rate lowered less than the value assigned by 
    INDEX250.
    (b) 1 0 -
    (c) 2 0 Data output is impossible due to SMDR apparatus 
    failure.
    b0: 0/1 = Data assigned by the ASYD, SYS1, INDEX249, 250 is valid/
    invalid 
    						
    							CHAPTER 3 NDA-24307
    Page 134
    Issue 1
    SYSTEM MESSAGES
    ➂ Buffer Usage Rate Assigned by 
    ASYD, SYS1, INDEX249
    ➃ Buffer Usage Rate Assigned by 
    ASYD, SYS1, INDEX250
    (b) FS = 1, FE = 0
    ➁
    ➂ 
    Overflow Rate
    ➃ Overflow Rate b7 b6 b5 b4 b3 b2 b1 b0
    b7 b6 b5 b4 b3 b2 b1 b0
    b1 b0
    b0
    b7 b6 b5 b4
    b0-b3: Units
    b4-b7: Tens
    b0-b3: Units
    b4-b7: Tens
    b0, b1: Fault Grade by ALMG command
    00 = NON CONT 01 = SUP
    10 = MN 11 = MJ
    b0: 0/1 = -/100% Overflow
    b4-b7: 1-9 = 10%-90% Overflow 
    						
    							NDA-24307 CHAPTER 3
    Page 135
    Issue 1
    SYSTEM MESSAGES
    (c) FS = 2, FE = 0
    ➁ SMDR Group No.
    ➂ Port No.
    ➃ Not used
    (d) FS = 3, FE = 0
    ➁
    b3 b2 b1 b0
    b7 b6 b5 b4 b3 b2 b1 b0
    b3 b2 b1 b0
    b0-b3: SMDR Group No. to which failure occurred
    b0-b7: Port No. allocated for SMDR Group to which failure occurred (0-7)
    b0-b3: SMDR Group No. to which failure occurred 
    						
    							CHAPTER 3 NDA-24307
    Page 136
    Issue 1
    SYSTEM MESSAGES
    This message displays when the SMDR output buffer usage rate has been lowered to less than the value
    assigned in the ASYD, SYS1, INDEX250 after the rate exceeds the value assigned by INDEX249.
    ➀ Detail Information
    1: XX00 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀ 
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b7 b6 b5 b4 b3 b2 b1 b0
    Default Alarm:
    NON6-PSMDR Output Buffer Overflow ReleaseDefault Grade:
    0Grade Modified: Lamp Modified:
    b0-b7: 00H = After SMDR output buffer usage rate exceeds the value 
    assigned by ASYD, SYS1, INDEX249, the rate lowered less than 
    the value assigned by INDEX250. 
    						
    							NDA-24307 CHAPTER 3
    Page 137
    Issue 1
    SYSTEM MESSAGES
    This message displays after the office data is loaded and system initialization has executed.
    ➀ 
    ➁ 
    Load Status
    1: XXXX XX00 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀  ➁
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b4 b3 b2 b1 b0
    b7 b6 b5 b4 b3 b2 b1 b0
    b11 b9 b8
    Default Alarm:
    NON7-ASystem Initialize With Data LoadDefault Grade:
    3Grade Modified: Lamp Modified:
    b0: 0/1 = IPL/PWR ON
    b1: 0/1 = Load Key OFF/ON
    b2: 0/1 = IPL KEY/MAT INITIAL
    b3: 0/1 = Program load is executed/-
    b4: 0/1 = -/Phase1 Restart Note 1
    b0: Office Data Load Status
    0/1 = Load OK/NG
    b1: Call Forwarding Data Load Status
    0/1 = Load OK/NG
    b2: Individual Speed Calling Data Load Status
    0/1 = Load OK/NG
    b3: RCF Data Load Status
    0/1 = Load OK/NG
    b4: Name Display Data Load Status
    0/1 = Load OK/NG
    b5: Network DM Load Status
    0/1 = Load OK/NG
    b6: Local DM Load Status
    0/1 = Load OK/NG
    b7: 0/1 = DM Load/Non Load
    b8: User assign Soft Key Data Load Status
    0/1 = Load OK/NG
    b9: Number Sharing Data Load Status
    0/1 = Load OK/NG Note 2
    b11: Call Block Data Load Status 
    0/1 = Load OK/NG 
    						
    							CHAPTER 3 NDA-24307
    Page 138
    Issue 1
    SYSTEM MESSAGES
    Note 1:
    Phase 1 Restart is executed when initializing the system without disrupting the following two-way
    connections that have already been established:
    Basic two-way connections (STN-STN, STN-TRK, TRK-TRK)
    Fixed connections
    Two-way connections established on a Fusion link
    Note 2:The Number Sharing data load also affects the data load of Dual Station Calling Over-FCCS .
    For more details, see Chapter 6, Section 12. 
    						
    							NDA-24307 CHAPTER 3
    Page 139
    Issue 1
    SYSTEM MESSAGES
    This message displays when system initialization is activated.
    ➀
    ➁
     Details on Intialization Note 2
    ➂ FPC No. Note 2
    Note 1:
    Phase 1 Restart is executed when initializing the system without disrupting the following two-way
    connections that have already been established:
    Basic two-way connections (STN-STN, STN-TRK, TRK-TRK)
    Fixed connections
    Two-way connections established on a Fusion link
    Note 2:When the whole system is initialized via key information from the ISW, this message is output in each
    LN/ISW. However, the data 
    ➁ and ➂ are displayed at the ISW only.
    For more details, see Chapter 6, Section 12.
    1: XX00 XX00 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀ ➁  ➂
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b4 b3 b2
    b1 b0
    b7 b6 b5 b4 b3 b2 b1 b0
    Default Alarm:
    NON7-BSystem InitializeDefault Grade:
    3Grade Modified: Lamp Modified:
    b2: 0/1 = IPL KEY/MAT INITIAL
    b3: 0/1 = Program Load/Non Load
    b4: 0/1 = -/Phase1 Restart Note 1
    b0: 0/1 = -/ISW 
    → LN Remote Initialization Request
    b1: 0/1 = -/ISW 
    → LN Data Sending Error
    b0-b7: FPC No. of LN where initialization request sent 
    						
    							CHAPTER 3 NDA-24307
    Page 140
    Issue 1
    SYSTEM MESSAGES
    This message displays when the MBR switch on the CPU Front Panel has been turned ON at the time of CPU
    changeover or speech path changeover.
    ➀ Self-CPU Restart Information
    ➁ Mate-CPU Restart Information
    1: XXXX 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀ ➁
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b7 b5 b4 b3 b0
    b7 b5 b4 b3 b0
    Default Alarm:
    NON7-CCPU MBR Key Turn ONDefault Grade:
    3Grade Modified: Lamp Modified:
    b0: 0/1 = -/Monitor Restart
    b3: 0/1 = -/Initialization
    b4: 0/1 = -/Data Copy Restart (for Dual-CPU system only)
    b5: 0/1 = -/MB control
    b7: 0/1 = ACT/STBY (active system indication after restart)
    b0: 0/1 = -/Monitor Restart
    b3: 0/1 = -/Initialization
    b4: 0/1 = -/Data Copy Restart (for Dual-CPU system only)
    b5: 0/1 = -/MB control
    b7: 0/1 = ACT/STBY (active system indication after restart) 
    						
    							NDA-24307 CHAPTER 3
    Page 141
    Issue 1
    SYSTEM MESSAGES
    This message displays when the MBR switch on the CPU Front Panel has been turned OFF at the time of CPU
    changeover or speech path changeover.
    ➀ Self-CPU Restart Information
    ➁ Mate-CPU Restart Information
    1: XXXX 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀ ➁
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b7 b5 b4 b3 b0
    b7 b5 b4 b3 b0
    Default Alarm:
    NON7-DCPU MBR Key Turn OFFDefault Grade:
    3Grade Modified: Lamp Modified:
    b0: 0/1 = -/Monitor Restart
    b3: 0/1 = -/Initialization
    b4: 0/1 =  -/Data  Copy  Restart  (for  Dual-CPU  system  only)
    b5: 0/1 = -/MB control
    b7: 0/1 = ACT/STBY (active system indication after restart)
    b0: 0/1 = -/Monitor Restart
    b3: 0/1 = -/Initialization
    b4: 0/1 = -/Data Copy Restart (for Dual-CPU system only)
    b5: 0/1 = -/MB control
    b7: 0/1 = ACT/STBY (active system indication after restart) 
    						
    							CHAPTER 3 NDA-24307
    Page 142
    Issue 1
    SYSTEM MESSAGES
    This message displays when the MBR switch on the TSW card has been turned ON at CPU changeover or
    speech path changeover.
    ➀ System Status of TSW Card
    1: XX00 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀ 
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b7 b0
    Default Alarm:
    NON7-ETSW MBR Key Turn ONDefault Grade:
    3Grade Modified: Lamp Modified:
    b0: 0/1 = No. 0 system/No. 1 system
    b7: Kind of PKG
    0/1 = SW12/GT09 
    						
    All NEC manuals Comments (0)