    							NDA-24307 CHAPTER 3
    Page 113
    Issue 1
    SYSTEM MESSAGES
    This message displays when a PCI card failure occurs.
    ➀ Fault detection on PCI card
    ➁ Error status on PCI slot 0
    ➂ Error status on PCI slot 1
    ➃ Not used
    ➄ Error status on PCI slot 3
    Note 1:Physical Connection Error
    Ethernet cable is disconnected.
    Ethernet cable has short-circuited.
    Ethernet straight/cross cable selection error
    Note 2:Hardware Fault
    Transmitter failure
    Controller lock-up
    1: 0X0X 0X0X 0X00 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀ ➁ ➂ ➃ ➄
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b3 b2 b1 b0
    b1 b0
    b1 b0
    b1 b0
    Default Alarm:
    MN4-UPCI Card FailureDefault Grade:
    3Grade Modified: Lamp Modified:
    b0: 0/1 = -/Error detection on PCI slot 0 (LANI-A)
    b1: 0/1 = -/Error detection on PCI slot 1
    b2: 0/1 = -/Error detection on PCI slot 2 (Not used)
    b3: 0/1 = -/Error detection on PCI slot 3 (LANI-B)
    b0: 0/1 = -/Physical connection error Note 1
    b1: 0/1 = -/Hardware Fault Note 2
    b0: 0/1 = -/Physical connection error Note 1
    b1: 0/1 = -/Hardware Fault Note 2
    b0: 0/1 = -/Physical connection error Note 1
    b1: 0/1 = -/Hardware Fault Note 2 
    						
    							CHAPTER 3 NDA-24307
    Page 114
    Issue 1
    SYSTEM MESSAGES
    This message displays when the PCI card, which was detected as faulty, is recovered.
    ➀ Detection of PCI restoration
    ➁Details on error restoration 
    (PCI slot 0)
    ➂Details on error restoration 
    (PCI slot 1)
    ➃Not used
    ➄Details on error restoration (PCI 
    slot 3)
    Note:Physical Connection Error
    Ethernet cable is disconnected.
    Ethernet cable has short-circuited.
    Ethernet straight/cross cable selection error
    1: 0X0X 0X0X 0X00 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀ ➁ ➂ ➃ ➄
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b3 b2 b1 b0
    b0
    b0
    b0
    Default Alarm:
    MN4-VPCI Card Failure RecoveredDefault Grade:
    3Grade Modified: Lamp Modified:
    b0: 0/1 = -/Error restoration on PCI slot 0 (LANI-A)
    b1: 0/1 = -/Error restoration on PCI slot 1
    b2: 0/1 = -/Error restoration on PCI slot 2 (Not used)
    b3: 0/1 = -/Error restoration on PCI slot 3 (LANI-B)
    b0: 0/1 = -/Physical connection error restoration Note
    b0: 0/1 = -/Physical connection error restoration Note
    b0: 0/1 = -/Physical connection error restoration Note 
    						
    							NDA-24307 CHAPTER 3
    Page 115
    Issue 1
    SYSTEM MESSAGES
    This message displays when any of the following faults are detected:
    Power failure
    Fuse blowing
    In-Frame abnormal temperature
    ➀ Probable cause for the failure
    ➁The frame in which a fault is 
    detected
    ➂ Factor of the failure
    See Chapter 5 for repair procedure.
    1: XX00 XXXX 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀  ➁ ➂
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b4 b3 b2 b1 b0
    b7 b6 b5 b4 b3 b2 b1 b0
    b4 b3 b2 b1 b0
    Default Alarm:
    NON6-ASystem FailureDefault Grade:
    3Grade Modified:
    (FIXED) NONLamp Modified:
    (FIXED) 3
    b0: Input power (-48V) down or failure
    b1: PWR Supply Fault
    b2: PWR Supply Fuse Alarm
    b3: Abnormal temperature MJ (70ºC (158ºF))
    b4: Abnormal temperature MN (60ºC (140ºF))
    b0-b3: Frame No. (0-3)
    b4, b5: Frame Group No. (0 only)
    b6, b7: Kind of frame
    00 = IMG
    b0: 0/1 = -/OBP Alarm 0 side
    b1: 0/1 = -/OBP Alarm 1 side
    b2: 0/1 = -/OBP Alarm MISC side
    b3: 0/1 = -/Power Alarm 0 side
    b4: 0/1 = -/Power Alarm 1 side 
    						
    							CHAPTER 3 NDA-24307
    Page 116
    Issue 1
    SYSTEM MESSAGES
    This message displays when a fault in either the ringer or howler tone occurs in the PWR card.
    ➀Unit and MG number of fault 
    detection
    ➁ Kind of the fault
    1: XXXX 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀ ➁
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b2 b1 b0
    b1 b0
    Default Alarm:
    MN6-BRGU and Howler FailureDefault Grade:
    3Grade Modified: Lamp Modified:
    b0, b1: Unit No. (0-3)
    b2: 0/1 = Even-numbered MG/Odd-numbered MG
    b0: 0/1 = -/RGU (Ringing Unit) Fault
    b1: 0/1 = -/Howler Fault 
    						
    							NDA-24307 CHAPTER 3
    Page 117
    Issue 1
    SYSTEM MESSAGES
    This message displays when the CPU usage (occupancy) rate exceeds the value assigned to ASYD, SYS1,
    INDEX56, and the call origination from the pre-selected group of stations is restricted (i.e. Line Load Control
    is set). This system message is always indicated as 0.
    1: 0000 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    Default Alarm:
    NON6-CLine Load Control StartDefault Grade:
    3Grade Modified: Lamp Modified: 
    						
    							CHAPTER 3 NDA-24307
    Page 118
    Issue 1
    SYSTEM MESSAGES
    This message displays when the CPU usage (occupancy) rate becomes lower than the value assigned to ASYD,
    SYS1, INDEX57, and Line Load Control is cancelled. This system message is always indicated as 0.
    1: 0000 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    Default Alarm:
    NON6-DLine Load Control StopDefault Grade:
    2Grade Modified: Lamp Modified: 
    						
    							NDA-24307 CHAPTER 3
    Page 119
    Issue 1
    SYSTEM MESSAGES
    This message displays to indicate the result of Bad Call Notification.
    ➀ Bad Call Notification
    1: XXXX XXXX XXXX XXXX 2: XXXX XXXX XXXX XXXX 3: 0000 0000 0000 0000
    ➀ ➁ ➂ ➃ ➄ ➅ ➆ ➇ ➈ ➉11
    12
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b7 b6 b5 b4 b3 b2 b1 b0
    Default Alarm:
    SUP6-HBad Call NotificationDefault Grade:
    2Grade Modified: Lamp Modified:
    b0-b3: Station number digit with the fault. (This data is always indicated as 
    “0” when Type of connection is 2 (ACD Trunk).)
    b4-b7: Type of connection
    0 = Station connection
    1 = Trunk connection
    2 = ACD Trunk connection 
    						
    							CHAPTER 3 NDA-24307
    Page 120
    Issue 1
    SYSTEM MESSAGES
    When type of connection is intra-Station connection
    ➁ ~ ➃ Station number (see table)
    ➄ Called station number
    ➅ ~ ➇ Called station number 
    (See table)
    ➈ Time Slot Number of Link 1 Note 1
    ➉ Not used
     Time Slot Number of Link 2 Note 1
     Not used
    Note 1:Station at which the operation was performed as shown in the figure below. b7 b6 b5 b4 b3 b2 b1 b0
    b3 b2 b1 b0
    b7 b6 b5 b4 b3 b2 b1 b0
    b4-b7b0-b3
    ➁DC0 DC1
    ➂DC2 DC3
    ➃DC4 DC5
    b0-b3: Number of digits for the called station number
    b4-b7b0-b3
    ➅DC0 DC1
    ➆DC2 DC3
    ➇DC4 DC5
    11
    12
    CALLED SIDE (TRUNK)
    LINK 1
    LINK 2 
    						
    							NDA-24307 CHAPTER 3
    Page 121
    Issue 1
    SYSTEM MESSAGES
    When type of connection is Trunk connection
    ➁ ~ ➃ Station number (See table)
    ➄ Remote Route No.
    ➅ Remote Route No.
    ➆ Called trunk No.
    ➇ Not used
    ➈ Time Slot Number of Link 1 Note 1
    ➉ Not used
     Time Slot Number of Link 2 Note 1
     Not used
    Note 1:Station at which the operation was performed as shown below. b7 b6 b5 b4 b3 b2 b1 b0
    b7 b6 b5 b4 b3 b2 b1 b0
    b3 b2 b1 b0
    b7 b6 b5 b4 b3 b2 b1 b0
    b4-b7 b0-b3
    ➁DC0 DC1
    ➂DC2 DC3
    ➃DC4 DC5
    b0-b5: Route No. (1-63)
    b6: OP
    0/1 = Data in OPRT ( 
    ➅ ) is invalid/valid
    b7: AC
    0/1 = Internal trunk/External trunk
    b0-b3: OPRT Route No. (Over 64)
    b0-b7: Trunk No. 
    11
    12
    CALLED SIDE (TRUNK)
    LINK 1
    LINK 2 
    						
    							CHAPTER 3 NDA-24307
    Page 122
    Issue 1
    SYSTEM MESSAGES
    When type of connection is ACD Trunk connection
    ➁ ACD Trouble Kind
    Note 1:When“➁ (ACD Trouble Kind)” is 01 Hex:
    ➂ ~ ➅ Information on Calling Party
    ➆ ➇ Not Used
    ➈ ➉ Information on Calling Party
    Refer to 
    Information on Held Party or 3rd Station/Trunk in 3-Party Connection
    Refer to 
    Note 2:When“➁ (ACD Trouble Kind)” is 14 Hex:
    ➂ Issue of ACDP (First digit of decimal place)
    ➃ Issue of ACDP (Second digit of decimal place)
    Note 3:When“➁ (ACD Trouble Kind)” is 21 Hex:
    ➂ ~ ➅ Information on Calling Party
    Refer to 
    ➂ ~ ➅ of Note 1
    ➆ ➇ Not used
    ➈ ➉ Information on Unknown Pilot No.
    Refer to 
    ➂ ~ ➅, (a) Station of Note 1
    b7 b6 b5 b4 b3 b2 b1 b0
    b0-b7: ACD trouble kind
    01H=ACD trunk trouble key 
    Note 1
    14H=ACD reset start Note 2
    15H=Insufficient ACD memory
    16H=Insufficient ACD call record
    17H=Excessive business station on ACD calls
    18H=Excessive calls queued
    21H=Unknown Pilot No. called 
    Note 3
    24H=Illegal execution of ACD timeout procedure Note 4
    30H=ACD pointer error detection and recovery Note 5
    33H=ACDP reset completion Note 6
    34H=Call recovery failure on unknown Pilot No. Note 7
    37H=ACD Traffic (incoming) Capacity Over
    99H=Illegal ACD processing-trace stored 
    Note 4
    (b) Trunk 
    Route No.+Trunk No.
    Example:RT125,TKl0
    01 25 00 l0
     
    ➂ ➃ ➄ ➅
    b4-b7b0-b3
    ➂DC0
    ➃DC1 DC2
    ➄DC0
    ➅DC1 DC2
    Route No.
    Trunk No.
    (a) Station
    My Line No.
    b4-b7b0-b3
    ➂DC0 DC1
    ➃DC2 DC3
    ➄DC4 DC5
    ➅
    1112 
    						