NDA-24307 CHAPTER 3 Page 113 Issue 1 SYSTEM MESSAGES This message displays when a PCI card failure occurs. ➀ Fault detection on PCI card ➁ Error status on PCI slot 0 ➂ Error status on PCI slot 1 ➃ Not used ➄ Error status on PCI slot 3 Note 1:Physical Connection Error Ethernet cable is disconnected. Ethernet cable has short-circuited. Ethernet straight/cross cable selection error Note 2:Hardware Fault Transmitter failure Controller lock-up 1: 0X0X 0X0X 0X00 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000 ➀ ➁ ➂ ➃ ➄ 4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000 b3 b2 b1 b0 b1 b0 b1 b0 b1 b0 Default Alarm: MN4-UPCI Card FailureDefault Grade: 3Grade Modified: Lamp Modified: b0: 0/1 = -/Error detection on PCI slot 0 (LANI-A) b1: 0/1 = -/Error detection on PCI slot 1 b2: 0/1 = -/Error detection on PCI slot 2 (Not used) b3: 0/1 = -/Error detection on PCI slot 3 (LANI-B) b0: 0/1 = -/Physical connection error Note 1 b1: 0/1 = -/Hardware Fault Note 2 b0: 0/1 = -/Physical connection error Note 1 b1: 0/1 = -/Hardware Fault Note 2 b0: 0/1 = -/Physical connection error Note 1 b1: 0/1 = -/Hardware Fault Note 2

CHAPTER 3 NDA-24307 Page 114 Issue 1 SYSTEM MESSAGES This message displays when the PCI card, which was detected as faulty, is recovered. ➀ Detection of PCI restoration ➁Details on error restoration (PCI slot 0) ➂Details on error restoration (PCI slot 1) ➃Not used ➄Details on error restoration (PCI slot 3) Note:Physical Connection Error Ethernet cable is disconnected. Ethernet cable has short-circuited. Ethernet straight/cross cable selection error 1: 0X0X 0X0X 0X00 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000 ➀ ➁ ➂ ➃ ➄ 4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000 b3 b2 b1 b0 b0 b0 b0 Default Alarm: MN4-VPCI Card Failure RecoveredDefault Grade: 3Grade Modified: Lamp Modified: b0: 0/1 = -/Error restoration on PCI slot 0 (LANI-A) b1: 0/1 = -/Error restoration on PCI slot 1 b2: 0/1 = -/Error restoration on PCI slot 2 (Not used) b3: 0/1 = -/Error restoration on PCI slot 3 (LANI-B) b0: 0/1 = -/Physical connection error restoration Note b0: 0/1 = -/Physical connection error restoration Note b0: 0/1 = -/Physical connection error restoration Note

NDA-24307 CHAPTER 3 Page 115 Issue 1 SYSTEM MESSAGES This message displays when any of the following faults are detected: Power failure Fuse blowing In-Frame abnormal temperature ➀ Probable cause for the failure ➁The frame in which a fault is detected ➂ Factor of the failure See Chapter 5 for repair procedure. 1: XX00 XXXX 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000 ➀ ➁ ➂ 4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000 b4 b3 b2 b1 b0 b7 b6 b5 b4 b3 b2 b1 b0 b4 b3 b2 b1 b0 Default Alarm: NON6-ASystem FailureDefault Grade: 3Grade Modified: (FIXED) NONLamp Modified: (FIXED) 3 b0: Input power (-48V) down or failure b1: PWR Supply Fault b2: PWR Supply Fuse Alarm b3: Abnormal temperature MJ (70ºC (158ºF)) b4: Abnormal temperature MN (60ºC (140ºF)) b0-b3: Frame No. (0-3) b4, b5: Frame Group No. (0 only) b6, b7: Kind of frame 00 = IMG b0: 0/1 = -/OBP Alarm 0 side b1: 0/1 = -/OBP Alarm 1 side b2: 0/1 = -/OBP Alarm MISC side b3: 0/1 = -/Power Alarm 0 side b4: 0/1 = -/Power Alarm 1 side

CHAPTER 3 NDA-24307 Page 116 Issue 1 SYSTEM MESSAGES This message displays when a fault in either the ringer or howler tone occurs in the PWR card. ➀Unit and MG number of fault detection ➁ Kind of the fault 1: XXXX 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000 ➀ ➁ 4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000 b2 b1 b0 b1 b0 Default Alarm: MN6-BRGU and Howler FailureDefault Grade: 3Grade Modified: Lamp Modified: b0, b1: Unit No. (0-3) b2: 0/1 = Even-numbered MG/Odd-numbered MG b0: 0/1 = -/RGU (Ringing Unit) Fault b1: 0/1 = -/Howler Fault

NDA-24307 CHAPTER 3 Page 117 Issue 1 SYSTEM MESSAGES This message displays when the CPU usage (occupancy) rate exceeds the value assigned to ASYD, SYS1, INDEX56, and the call origination from the pre-selected group of stations is restricted (i.e. Line Load Control is set). This system message is always indicated as 0. 1: 0000 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000 4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000 Default Alarm: NON6-CLine Load Control StartDefault Grade: 3Grade Modified: Lamp Modified:

CHAPTER 3 NDA-24307 Page 118 Issue 1 SYSTEM MESSAGES This message displays when the CPU usage (occupancy) rate becomes lower than the value assigned to ASYD, SYS1, INDEX57, and Line Load Control is cancelled. This system message is always indicated as 0. 1: 0000 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000 4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000 Default Alarm: NON6-DLine Load Control StopDefault Grade: 2Grade Modified: Lamp Modified:

NDA-24307 CHAPTER 3 Page 119 Issue 1 SYSTEM MESSAGES This message displays to indicate the result of Bad Call Notification. ➀ Bad Call Notification 1: XXXX XXXX XXXX XXXX 2: XXXX XXXX XXXX XXXX 3: 0000 0000 0000 0000 ➀ ➁ ➂ ➃ ➄ ➅ ➆ ➇ ➈ ➉11 12 4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000 b7 b6 b5 b4 b3 b2 b1 b0 Default Alarm: SUP6-HBad Call NotificationDefault Grade: 2Grade Modified: Lamp Modified: b0-b3: Station number digit with the fault. (This data is always indicated as “0” when Type of connection is 2 (ACD Trunk).) b4-b7: Type of connection 0 = Station connection 1 = Trunk connection 2 = ACD Trunk connection

CHAPTER 3 NDA-24307 Page 120 Issue 1 SYSTEM MESSAGES When type of connection is intra-Station connection ➁ ~ ➃ Station number (see table) ➄ Called station number ➅ ~ ➇ Called station number (See table) ➈ Time Slot Number of Link 1 Note 1 ➉ Not used Time Slot Number of Link 2 Note 1 Not used Note 1:Station at which the operation was performed as shown in the figure below. b7 b6 b5 b4 b3 b2 b1 b0 b3 b2 b1 b0 b7 b6 b5 b4 b3 b2 b1 b0 b4-b7b0-b3 ➁DC0 DC1 ➂DC2 DC3 ➃DC4 DC5 b0-b3: Number of digits for the called station number b4-b7b0-b3 ➅DC0 DC1 ➆DC2 DC3 ➇DC4 DC5 11 12 CALLED SIDE (TRUNK) LINK 1 LINK 2

NDA-24307 CHAPTER 3 Page 121 Issue 1 SYSTEM MESSAGES When type of connection is Trunk connection ➁ ~ ➃ Station number (See table) ➄ Remote Route No. ➅ Remote Route No. ➆ Called trunk No. ➇ Not used ➈ Time Slot Number of Link 1 Note 1 ➉ Not used Time Slot Number of Link 2 Note 1 Not used Note 1:Station at which the operation was performed as shown below. b7 b6 b5 b4 b3 b2 b1 b0 b7 b6 b5 b4 b3 b2 b1 b0 b3 b2 b1 b0 b7 b6 b5 b4 b3 b2 b1 b0 b4-b7 b0-b3 ➁DC0 DC1 ➂DC2 DC3 ➃DC4 DC5 b0-b5: Route No. (1-63) b6: OP 0/1 = Data in OPRT ( ➅ ) is invalid/valid b7: AC 0/1 = Internal trunk/External trunk b0-b3: OPRT Route No. (Over 64) b0-b7: Trunk No. 11 12 CALLED SIDE (TRUNK) LINK 1 LINK 2

CHAPTER 3 NDA-24307 Page 122 Issue 1 SYSTEM MESSAGES When type of connection is ACD Trunk connection ➁ ACD Trouble Kind Note 1:When“➁ (ACD Trouble Kind)” is 01 Hex: ➂ ~ ➅ Information on Calling Party ➆ ➇ Not Used ➈ ➉ Information on Calling Party Refer to Information on Held Party or 3rd Station/Trunk in 3-Party Connection Refer to Note 2:When“➁ (ACD Trouble Kind)” is 14 Hex: ➂ Issue of ACDP (First digit of decimal place) ➃ Issue of ACDP (Second digit of decimal place) Note 3:When“➁ (ACD Trouble Kind)” is 21 Hex: ➂ ~ ➅ Information on Calling Party Refer to ➂ ~ ➅ of Note 1 ➆ ➇ Not used ➈ ➉ Information on Unknown Pilot No. Refer to ➂ ~ ➅, (a) Station of Note 1 b7 b6 b5 b4 b3 b2 b1 b0 b0-b7: ACD trouble kind 01H=ACD trunk trouble key Note 1 14H=ACD reset start Note 2 15H=Insufficient ACD memory 16H=Insufficient ACD call record 17H=Excessive business station on ACD calls 18H=Excessive calls queued 21H=Unknown Pilot No. called Note 3 24H=Illegal execution of ACD timeout procedure Note 4 30H=ACD pointer error detection and recovery Note 5 33H=ACDP reset completion Note 6 34H=Call recovery failure on unknown Pilot No. Note 7 37H=ACD Traffic (incoming) Capacity Over 99H=Illegal ACD processing-trace stored Note 4 (b) Trunk Route No.+Trunk No. Example:RT125,TKl0 01 25 00 l0 ➂ ➃ ➄ ➅ b4-b7b0-b3 ➂DC0 ➃DC1 DC2 ➄DC0 ➅DC1 DC2 Route No. Trunk No. (a) Station My Line No. b4-b7b0-b3 ➂DC0 DC1 ➃DC2 DC3 ➄DC4 DC5 ➅ 1112