NDA-24307 CHAPTER 8 Page 633 Issue 1 DLSS_T: Display of Lock Out Station - Number- Telephone Number DLSS_T:Display of Lock Out Station - Number- Telephone Number 1. Functional Outline This command is used to print out stations in lockout state, by using Telephone Numbers. This command is available at NCN (for Fusion network) only. Note Note: This command is available for PBX program software. 2. Parameters Input data Type: Printout of all lockout stations Printout of lockout stations by tenant Printout of lockout stations within a specified range of station number UGN: User Group Number Note 1, Note 2 Start TELN: First Telephone Number (max. 16 digits) Note 2 End TELN: End Telephone Number (max. 16 digits) Note 2 Note 1: This parameter is valid when “Type = Printout of lockout stations by tenant” is selected. Note 2:This parameter is valid when “Type = Printout of lockout stations within a specified range of station number” is selected. Display data FPC: Fusion Point Code (1-253) TN: Tenant Number Start STN: First Physical Station Number (max. 5 digits for Business/max. 6 digits for Hotel system) End STN: End Physical Station Number (max. 5 digits for Business/max. 6 digits for Hotel system) CNT: Count UGN: User Group Number TELN: Telephone Number (max. 16 digits) LENS: Line Equipment Number Buttons Get: Click to get information on the lockout station Exit: Click to exit this command.

CHAPTER 8 NDA-24307 Page 634 Issue 1 DLTEL: Display of Telephone Number from LENS for LDM DLTEL:Display of Telephone Number from LENS for LDM 1. Functional Outline This command, available at each Local Node (LN), is used to display the Telephone Number or other station data by designating a specific LEN. 2. Parameters Input data LENS: Line Equipment Number [6 digits] Display data UGN: User Group Number TELN: Telephone Number [Max. 16 digits] TN: Tenant Number STN: Station Number [Max. 6 digits] TEC: Telephone Equipment Class [1-31] RSC: Route Restriction Class [0-15] SFC: Service Feature Class [0-15]

NDA-24307 CHAPTER 8 Page 635 Issue 1 DNTEL: Display of Telephone Number from LENS for NDM DNTEL:Display of Telephone Number from LENS for NDM 1. Functional Outline This command, available at Network Control Node (NCN) only, is used to display the Telephone Number or other station data by designating a specific FPC and LEN. 2. Parameters Input data FPC: Fusion Point Code [1-253] LENS: Line Equipment Number [6 digits] Display data UGN: User Group Number TELN: Telephone Number [Max. 16 digits] NID: Network ID Note TN: Tenant Number STN: Station Number [Max. 6 digits] TEC: Telephone Equipment Number [1-31] RSC: Route Restriction Class [0-15] SFC: Service Feature Class [0-15] Note:Network ID (NID) is allocated automatically when the Module Group/Unit data is assigned by the AFMU command. Refer to the “Fusion Network System Manual” for more information.

CHAPTER 8 NDA-24307 Page 636 Issue 1 DPKG: Display of Setting Port Package DPKG:Display of Setting Port Package 1. Functional Outline This command is used to display the circuit card name accommodated in each Group of a specific UNIT. Note 1:When using this command, make sure that each circuit card related database files have already been installed to your MAT. (See FLINST command for more information.) 2. Parameters Input data MG: Module Group (MG) number [00-07] UNIT: Unit (U) number [0-3] Buttons Get: Click to get information on mounted circuit cards. Close: Click to exit this command. Note:When the Input Data above is entered and the “Get” button is pressed, the related circuit card name is displayed on a Group basis. However, if the name is not found for some reasons, the following mark may appear in the relevant display field. #→Unidentifiable firm ware type. ##→Data not found in the FMID (database). ###→Group data not assigned. *→Circuit card name not found (for the card is in make-busy state, etc.).

NDA-24307 CHAPTER 8 Page 637 Issue 1 DPSW: Display Package Switch Status DPSW:Display Package Switch Status 1. Functional Outline This command is used to display the following information on a Line/Trunk or Control circuit card: [When MAT is in On-Line Mode (=connected to the system)] Current status of each switch Explanation of each switch function [When MAT is in Off-Line Mode (= not connected to the system)] Explanation of each switch function Note 1:When using this command, make sure that each circuit card related database files have already been installed to your MAT. (See FLINST command for more information.) 2. Parameters Input data KIND: Display Kind (selection) (MAT=) On-Line Mode (MAT=) Off-Line Mode TYPE: Circuit Card Type (selection) Line Trunk Package Control Package PMN: Port Micro Processor Number PKG NAME: Circuit Card Name LP/ISW: Local Partition Number [00-06 (Even Number only)] or ISW Number Note SYSTEM: System Note 0=No.0 System 1=No.1 System MG: Module Group Number [00-07] Note UNIT: Unit Number [0-3] Note ACT/ST-BY: ACT/ST-BY information Note 0=ACT 1=ST-BY 2=Not used NODE: Node Number [0-3] CLINE: Collection Line Note 0=Out of Service 1=In Service No: IOC Card Number [0/1] Note Note: This parameter may appear when “Control Package” is selected in the “TYPE” parameter.

CHAPTER 8 NDA-24307 Page 638 Issue 1 DPSW: Display Package Switch Status Buttons Get: Click to view the display data Page Up: Click to view the next page data (when next page exists). Page Down: Click to return to the previous page data. Exit: Click to exit this command. Display data PKG Name: Circuit Card Name Firm Name/Issue: Firm Name/Issue of the circuit cardEach switch data is also displayed on the dedicated display page. Each switch data is also displayed on the dedicated display page.

NDA-24307 CHAPTER 8 Page 639 Issue 1 DSTN: Display of Station Data DSTN:Display of Station Data 1. Functional Outline This command is used to display the registered Station Data corresponding to the designated Tenant and Sta- tion Number. In addition, the information of Hot Line, D term Key Layout, Hunting, and Call Pickup, etc., can also be displayed as the data related to the designated stations. 2. Parameters Input data TN: Tenant Number STN: Station Number [0-9, #, * (Max. 6 digits)] Buttons [For display data selection] SHP: Station Hunting Group-Pilot Note KYD: Key Data for Dterm Note CPG: Call Pickup Group Note CPE: Call Pickup Expand Group Note PHN: Phantom Station Number Note SHC: Station Hunting-Circular Note SHU: Station Hunting-UCD Note HLS: Hot Line Station Note Note: When the designated station has any of these data, the corresponding button(s) can be selected. If the data is necessary, click the button(s). [For execution order] Get: Click to view the display data. Close: Click to exit this command. Display data (by Parameters) ETN: Effective Tenant Number LENS: Line Equipment Number (6 digits) TEC: Telephone Equipment Class [1-31] 1=DP (10pps) 2=PB 3=DP/PB 4=DP (20pps) 5-11=Not used 12=D term 13=Data Terminal via Dterm14=Hot Line 15=CAS Line 16=Data Terminal via Data Module 17=Not used 18=Virtual Line Appearance (for D term Multi-Line) 19-22=Not used 23=ISDN Terminal 24-26=Not used 27=8 Conference Equipment 28-31=Not used RSC: Route Restriction Class [0-15] SFC: Service Feature Class [0-15]

CHAPTER 8 NDA-24307 Page 640 Issue 1 DTELN: Display of Telephone Number Data for NDM DTELN:Display of Telephone Number Data for NDM 1. Functional Outline This command is used to display the registered station data corresponding to specified User Group Number (UGN) and Telephone Number (TELN). The following data related to Number Group can be displayed by clicking the selection button for each data. This command can be used only when logging in to Network Control Node (NCN). ACPGN: Call Pickup Group (NDM) ACPEN: Call Pickup Expand Group (NDM) ASHUN: Station Hunting Group-UCD (NDM) ASHCN: Station Hunting Group-Circular (NDM) AHLSN: Hot Line Station (NDM) ASHPN: Station Hunting Group-Pilot (NDM) AKYD: Key Data for D term 2. Parameters Input Data UGN: User Group Number TELN: Telephone Number Display Data FPC: Fusion Point Code (1-253) TN: Tenant Number STN: Station Number LENS: Line Equipment Number (6 digits) MG: Module Group Number UNIT: Unit Number G: Group Number LV: Level Number TEC: Telephone Class (1-31) RSC: Route Restriction Class (0-15) SFC: Service Feature Restriction Class (0-15) Selection Button CPGN :Call Pickup Group (NDM) CPEN :Call Pickup Expand Group (NDM) SHUN :Station Hunting Group-UCD (NDM) SHCN :Station Hunting Group-Circular (NDM) HLSN :Hot Line Station (NDM) SHPN :Station Hunting Group-Pilot (NDM) KYD :Key Data for D term

NDA-24307 CHAPTER 8 Page 641 Issue 1 DTF101: Display of Terminal Traffic Data DTF101:Display of Terminal Traffic Data 1. Functional Outline This command displays the result of traffic measurement data for Type= 1 (Terminal Traffic) assigned by the ATRF command. 2. Parameters Traffic Data 1: Terminal Traffic-DTF101 Route Traffic-DTF102 Station Peg Count-DTF103 Attendant Peg Count-DTF104 Route Peg Count-DTF105 Traffic Data 2: Service Peg Count-DTF201 Traffic Data 3: UCD Route Peg Count-DTF301 UCD Group Peg Count-DTF302 UCD Station Peg Count-DTF303 Traffic Data 5: Attendant Answering Peg Count-DTF501 Traffic Data 6: Connection Route Peg Count-DTF601 Connection Route Traffic-DTF602

CHAPTER 8 NDA-24307 Page 642 Issue 1 DTF102: Display of Route Traffic Data DTF102:Display of Route Traffic Data 1. Functional Outline This command displays the result of traffic measurement data for Type= 2 (Route Traffic) assigned by the ATRF command. 2. Parameters Traffic Data 1: Terminal Traffic-DTF101 Route Traffic-DTF102 Station Peg Count-DTF103 Attendant Peg Count-DTF104 Route Peg Count-DTF105 Traffic Data 2: Service Peg Count-DTF201 Traffic Data 3: UCD Route Peg Count-DTF301 UCD Group Peg Count-DTF302 UCD Station Peg Count-DTF303 Traffic Data 5: Attendant Answering Peg Count-DTF501 Traffic Data 6: Connection Route Peg Count-DTF601 Connection Route Traffic-DTF602