    of 724
    							NDA-24307 CHAPTER 8
    Page 633
    Issue 1
    DLSS_T: Display of Lock Out Station - Number- Telephone Number
    DLSS_T:Display of Lock Out Station - Number- Telephone Number
    1. Functional Outline
    This command is used to print out stations in lockout state, by using Telephone Numbers. This command is
    available at NCN (for Fusion network) only. 
    Note
    Note:
    This command is available for PBX program software.
    2. Parameters
    Input data
    Type: Printout of all lockout stations
    Printout of lockout stations by tenant
    Printout of lockout stations within a specified range of station number
    UGN: User Group Number 
    Note 1, Note 2
    Start TELN: First Telephone Number (max. 16 digits) Note 2
    End TELN: End Telephone Number (max. 16 digits) Note 2
    Note 1:
    This parameter is valid when “Type = Printout of lockout stations by tenant” is selected.
    Note 2:This parameter is valid when “Type = Printout of lockout stations within a specified range of station
    number” is selected.
    Display data
    FPC: Fusion Point Code (1-253)
    TN: Tenant Number
    Start STN: First Physical Station Number (max. 5 digits for Business/max. 6 digits for Hotel
    system)
    End STN: End Physical Station Number (max. 5 digits for Business/max. 6 digits for Hotel
    system)
    CNT: Count
    UGN: User Group Number
    TELN: Telephone Number (max. 16 digits)
    LENS: Line Equipment Number
    Buttons
    Get: Click to get information on the lockout station
    Exit: Click to exit this command. 
    						
    							CHAPTER 8 NDA-24307
    Page 634
    Issue 1
    DLTEL: Display of Telephone Number from LENS for LDM
    DLTEL:Display of Telephone Number from LENS for LDM
    1. Functional Outline
    This command, available at each Local Node (LN), is used to display the Telephone Number or other station
    data by designating a specific LEN.
    2. Parameters
    Input data
    LENS: Line Equipment Number [6 digits]
    Display data
    UGN: User Group Number
    TELN: Telephone Number [Max. 16 digits]
    TN: Tenant Number
    STN: Station Number [Max. 6 digits]
    TEC: Telephone Equipment Class [1-31]
    RSC: Route Restriction Class [0-15]
    SFC: Service Feature Class [0-15] 
    						
    							NDA-24307 CHAPTER 8
    Page 635
    Issue 1
    DNTEL: Display of Telephone Number from LENS for NDM
    DNTEL:Display of Telephone Number from LENS for NDM
    1. Functional Outline
    This command, available at Network Control Node (NCN) only, is used to display the Telephone Number or
    other station data by designating a specific FPC and LEN.
    2. Parameters
    Input data
    FPC: Fusion Point Code [1-253]
    LENS: Line Equipment Number [6 digits]
    Display data
    UGN: User Group Number
    TELN: Telephone Number [Max. 16 digits]
    NID: Network ID 
    Note
    TN: Tenant Number
    STN: Station Number [Max. 6 digits]
    TEC: Telephone Equipment Number [1-31]
    RSC: Route Restriction Class [0-15]
    SFC: Service Feature Class [0-15]
    Note:Network ID (NID) is allocated automatically when the Module Group/Unit data is assigned by the
    AFMU command. Refer to the “Fusion Network System Manual” for more information. 
    						
    							CHAPTER 8 NDA-24307
    Page 636
    Issue 1
    DPKG: Display of Setting Port Package
    DPKG:Display of Setting Port Package
    1. Functional Outline
    This command is used to display the circuit card name accommodated in each Group of a specific UNIT.
    Note 1:When using this command, make sure that each circuit card related database files have already been
    installed to your MAT. (See FLINST command for more information.)
    2. Parameters
    Input data
    MG: Module Group (MG) number [00-07]
    UNIT: Unit (U) number [0-3]
    Buttons
    Get: Click to get information on mounted circuit cards.
    Close: Click to exit this command.
    Note:When the Input Data above is entered and the “Get” button is pressed, the related circuit card name is
    displayed on a Group basis. However, if the name is not found for some reasons, the following mark
    may appear in the relevant display field.
    #→Unidentifiable firm ware type.
    ##→Data not found in the FMID (database).
    ###→Group data not assigned.
    *→Circuit card name not found (for the card is in make-busy state, etc.). 
    						
    							NDA-24307 CHAPTER 8
    Page 637
    Issue 1
    DPSW: Display Package Switch Status
    DPSW:Display Package Switch Status
    1. Functional Outline
    This command is used to display the following information on a Line/Trunk or Control circuit card:
    [When MAT is in On-Line Mode (=connected to the system)]
    Current status of each switch
    Explanation of each switch function
    [When MAT is in Off-Line Mode (= not connected to the system)]
    Explanation of each switch function
    Note 1:When using this command, make sure that each circuit card related database files have already been
    installed to your MAT. (See FLINST command for more information.)
    2. Parameters
    Input data
    KIND: Display Kind (selection)
    (MAT=) On-Line Mode
    (MAT=) Off-Line Mode
    TYPE: Circuit Card Type (selection)
    Line Trunk Package
    Control Package
    PMN: Port Micro Processor Number
    PKG NAME: Circuit Card Name
    LP/ISW: Local Partition Number [00-06 (Even Number only)] or ISW Number 
    Note
    SYSTEM: System Note
    0=No.0 System
    1=No.1 System
    MG: Module Group Number [00-07] 
    Note
    UNIT: Unit Number [0-3] Note
    ACT/ST-BY: ACT/ST-BY information Note
    0=ACT
    1=ST-BY
    2=Not used
    NODE: Node Number [0-3]
    CLINE: Collection Line 
    Note
    0=Out of Service
    1=In Service
    No: IOC Card Number [0/1] 
    Note
    Note:
    This parameter may appear when “Control Package” is selected in the “TYPE” parameter. 
    						
    							CHAPTER 8 NDA-24307
    Page 638
    Issue 1
    DPSW: Display Package Switch Status
    Buttons
    Get: Click to view the display data
    Page Up: Click to view the next page data (when next page exists).
    Page Down: Click to return to the previous page data.
    Exit: Click to exit this command.
    Display data
    PKG Name: Circuit Card Name
    Firm Name/Issue: Firm Name/Issue of the circuit cardEach switch data is also displayed on the dedicated
    display page.
    Each switch data is also displayed on the dedicated display page. 
    						
    							NDA-24307 CHAPTER 8
    Page 639
    Issue 1
    DSTN: Display of Station Data
    DSTN:Display of Station Data
    1. Functional Outline
    This command is used to display the registered Station Data corresponding to the designated Tenant and Sta-
    tion Number. In addition, the information of Hot Line, D
    term Key Layout, Hunting, and Call Pickup, etc., can
    also be displayed as the data related to the designated stations.
    2. Parameters
    Input data
    TN: Tenant Number
    STN: Station Number [0-9, #, * (Max. 6 digits)]
    Buttons 
    [For display data selection]
    SHP: Station Hunting Group-Pilot 
    Note
    KYD: Key Data for Dterm Note
    CPG: Call Pickup Group Note
    CPE: Call Pickup Expand Group Note
    PHN: Phantom Station Number Note
    SHC: Station Hunting-Circular Note
    SHU: Station Hunting-UCD Note
    HLS: Hot Line Station Note
    Note:
    When the designated station has any of these data, the corresponding button(s) can be selected. If the
    data is necessary, click the button(s).
    [For execution order]
    Get: Click to view the display data.
    Close: Click to exit this command.
    Display data (by Parameters)
    ETN: Effective Tenant Number
    LENS: Line Equipment Number (6 digits)
    TEC: Telephone Equipment Class [1-31]
    1=DP (10pps) 2=PB
    3=DP/PB 4=DP (20pps)
    5-11=Not used 12=D
    term
    13=Data Terminal via Dterm14=Hot Line
    15=CAS Line 16=Data Terminal via Data Module
    17=Not used 18=Virtual Line Appearance (for D
    term Multi-Line)
    19-22=Not used 23=ISDN Terminal
    24-26=Not used 27=8 Conference Equipment
    28-31=Not used
    RSC: Route Restriction Class [0-15]
    SFC: Service Feature Class [0-15] 
    						
    							CHAPTER 8 NDA-24307
    Page 640
    Issue 1
    DTELN: Display of Telephone Number Data for NDM
    DTELN:Display of Telephone Number Data for NDM
    1. Functional Outline
    This command is used to display the registered station data corresponding to specified User Group Number
    (UGN) and Telephone Number (TELN). The following data related to Number Group can be displayed by
    clicking the selection button for each data. This command can be used only when logging in to Network
    Control Node (NCN).
    ACPGN: Call Pickup Group (NDM)
    ACPEN: Call Pickup Expand Group (NDM)
    ASHUN: Station Hunting Group-UCD (NDM)
    ASHCN: Station Hunting Group-Circular (NDM)
    AHLSN: Hot Line Station (NDM)
    ASHPN: Station Hunting Group-Pilot (NDM)
    AKYD: Key Data for D
    term
    2. Parameters
    Input Data
    UGN: User Group Number
    TELN: Telephone Number
    Display Data
    FPC: Fusion Point Code (1-253)
    TN: Tenant Number
    STN: Station Number
    LENS: Line Equipment Number (6 digits)
    MG: Module Group Number
    UNIT: Unit Number
    G: Group Number
    LV: Level Number
    TEC: Telephone Class (1-31)
    RSC: Route Restriction Class (0-15)
    SFC: Service Feature Restriction Class (0-15)
    Selection Button
    CPGN :Call Pickup Group (NDM)
    CPEN :Call Pickup Expand Group (NDM)
    SHUN :Station Hunting Group-UCD (NDM)
    SHCN :Station Hunting Group-Circular (NDM)
    HLSN :Hot Line Station (NDM)
    SHPN :Station Hunting Group-Pilot (NDM)
    KYD :Key Data for D
    term 
    						
    							NDA-24307 CHAPTER 8
    Page 641
    Issue 1
    DTF101: Display of Terminal Traffic Data
    DTF101:Display of Terminal Traffic Data
    1. Functional Outline
    This command displays the result of traffic measurement data for Type= 1 (Terminal Traffic) assigned by the
    ATRF command.
    2. Parameters
    Traffic Data 1: Terminal Traffic-DTF101
    Route Traffic-DTF102
    Station Peg Count-DTF103
    Attendant Peg Count-DTF104
    Route Peg Count-DTF105
    Traffic Data 2: Service Peg Count-DTF201
    Traffic Data 3: UCD Route Peg Count-DTF301
    UCD Group Peg Count-DTF302
    UCD Station Peg Count-DTF303
    Traffic Data 5: Attendant Answering Peg Count-DTF501
    Traffic Data 6: Connection Route Peg Count-DTF601
    Connection Route Traffic-DTF602 
    						
    							CHAPTER 8 NDA-24307
    Page 642
    Issue 1
    DTF102: Display of Route Traffic Data
    DTF102:Display of Route Traffic Data
    1. Functional Outline
    This command displays the result of traffic measurement data for Type= 2 (Route Traffic) assigned by the
    ATRF command.
    2. Parameters
    Traffic Data 1: Terminal Traffic-DTF101
    Route Traffic-DTF102
    Station Peg Count-DTF103
    Attendant Peg Count-DTF104
    Route Peg Count-DTF105
    Traffic Data 2: Service Peg Count-DTF201
    Traffic Data 3: UCD Route Peg Count-DTF301
    UCD Group Peg Count-DTF302
    UCD Station Peg Count-DTF303
    Traffic Data 5: Attendant Answering Peg Count-DTF501
    Traffic Data 6: Connection Route Peg Count-DTF601
    Connection Route Traffic-DTF602 
    						