NDA-24307 CHAPTER 3 Page 103 Issue 1 SYSTEM MESSAGES This message displays when the DTI card detects abnormal state of a digital line but this failure has influence on the Speech path. When the status is getting worse, they system will issue [3-I] Digital Line Failure. ➀ Faulty PM (LENS) Location ➁ Kind of Fault ➂Fault Detection Time Slot No. (This data is valid only when the kind of fault is 08H) 1: XXXX XX00 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000 ➀ ➁ ➂ 4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000 b7 b6 b5 b4 b3 b2 b1 b0 b7 b6 b5 b4 b3 b2 b1 b0 b4 b3 b2 b1 b0 Default Alarm: SUP3-HDigital Line WarningDefault Grade: 2Grade Modified: Lamp Modified: b0-b4: Group b5, b6: Unit (0-3) b7: 0/1 = Even numbered MG/Odd numbered MG 01H = Frame alignment loss occurs three times a day 02H = Bit error rate is over 10 -6 03H = Slip occurs twice a day 04H = Multiframe alignment loss occurs three times a day 08H = Fault detection on the CCIS Bch b0-b4: Time Slot No. in which the Digital line failure is detected (1-16, 17-31)

CHAPTER 3 NDA-24307 Page 104 Issue 1 SYSTEM MESSAGES This message displays after [3-H] Digital Line Warning lasts in the DTI card over the particular time. This failure may cause a speech path fault to the DTI card. ➀ Faulty PM Location ➁ Kind of fault ➂Faulty Circuit Card Location (This data is valid when ➁ is 0FH) ➃ Faulty Circuit Card Location (This data is valid when ➁ is 0FH) 1: XXXX 0000 XXXX XXXX 2: XXXX XXXX XXXX XXXX 3: XXXX XXXX XXXX XXXX ➀ ➁ ➂ ➃ ➂ ➃ ➂ ➃ ➂ ➃ ➂ ➃ ➂ ➃ ➂ ➃ ➂ ➃ ➂ ➃ ➂ ➃ 4: XXXX XXXX 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000 ➂ ➃ ➂ ➃ 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000 b7 b6 b5 b4 b3 b2 b1 b0 b7 b6 b5 b4 b3 b2 b1 b0 b7 b6 b5 b4 b3 b7 b6 b5 b4 b3 b2 b1 b0 Default Alarm: SUP3-IDigital Line FailureDefault Grade: 3Grade Modified: Lamp Modified: b0-b4: Group b5, b6: Unit b7: Module Group 0/1 = Even-numbered MG/Odd-numbered MG 01H = Frame alignment loss occurs 100 times a day 03H = Slip occurs 50 times a day 04H = Multiframe alignment loss occurs 110 times a day 06H = Frame alignment loss lasts for 2 to 3 sec. 07H = Bit error rate is over 10 -4 09H = Warning signal (AIS) from the opposite office has been received for 1 sec. continuously. 0BH = Multiframe alignment loss lasts for 2 to 3 sec. 0FH = Digital Line is not restored b3-b7: Group No. b0, b1: Unit No. (0-3) b2-b7: MG No.

NDA-24307 CHAPTER 3 Page 105 Issue 1 SYSTEM MESSAGES This message displays when a digital line fault is restored. ➀ Faulty Line Location 1: XX00 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000 ➀ 4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000 b7 b6 b5 b4 b3 b2 b1 b0 Default Alarm: ON3-JDigital Line RestoreDefault Grade: 0Grade Modified: Lamp Modified: b0-b4: Group No. b5, b6: Unit No. (0-3) b7: Module Group 0/1 = Even-numbered MG/odd-numbered MG

CHAPTER 3 NDA-24307 Page 106 Issue 1 SYSTEM MESSAGES This message displays when a Ready Failure occurs in both systems as a result of the TSW card having a failure or the card is not mounted properly. ➀Faulty TSW Information See Chapter 5 for repair procedure. 1: XX00 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000 ➀ 4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000 b7 b1 b0 Default Alarm: MN4-CBoth TSW Ready FailureDefault Grade: 3Grade Modified: Lamp Modified: b0: 0/1 = TSW No. 0 system/TSW No. 1 system Note: When Ready Failure occurs in both systems, the [4-C] message is separately issued twice: “0” displays in one message, and “1” in the other message. b1: Details on faulty TSW card 0 = TSW card (LN) connection to MUX or TSW card within ISWM Note 1 1 = TSW card (LN) connected to TSW of ISWM Note 2 b7: Fault-detected circuit card 0 = PH-SW12 (LN) or PU-SW00 (ISW) 1 = PH-GT09 (LN only) Note 1 TSWM0 [ISW][LN0] TSW00TSW01TSW02TSW03 Note 2 To M U X (IMG0)To M U X (IMG1) Note 1 TSWM1 TSW00TSW01TSW02TSW03 Note 2 To M U X (IMG2)To M U X (IMG3) ISWM TSW00TSW01TSW02TSW03 To L N 1To L N 2To LN3 Note 1 Note 1:If a fault occurs in any of the TSW cards, “0” is set in bit 1 of ➀. Note 2:If a fault occurs in any of the TSW cards, “1” is set in bit 1 of ➀.

NDA-24307 CHAPTER 3 Page 107 Issue 1 SYSTEM MESSAGES This message displays when a TSW Ready Failure occurs in one of the dual systems because the TSW card fails or the card is not mounted properly. ➀Faulty TSW Information See Chapter 5 for repair procedure. 1: XX00 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000 ➀ 4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000 b7 b1 b0 Default Alarm: MN4-DTSW Ready FailureDefault Grade: 3Grade Modified: Lamp Modified: b0: 0/1 = TSW No. 0 system/TSW No. 1 system b1: Details on faulty TSW card 0 = TSW card (LN) connection to MUX or TSW card within ISWM Note 1 1 = TSW card (LN) connected to TSW of ISWM Note 2 b7: Fault-detected circuit card 0 = PH-SW12 (LN) or PU-SW00 (ISW) 1 = PH-GT09 (LN only) Note 1 TSWM0 [ISW][LN0] TSW00TSW01TSW02TSW03 Note 2 To M U X (IMG0)To M U X (IMG1) Note 1 TSWM1 TSW00TSW01TSW02TSW03 Note 2 To M U X (IMG2)To M U X (IMG3) ISWM TSW00TSW01TSW02TSW03 To L N 1To L N 2To LN3 Note 1 Note 1:If a fault occurs in any of the TSW cards, “0” is set in bit 1 of ➀. Note 2:If a fault occurs in any of the TSW cards, “1” is set in bit 1 of ➀.

CHAPTER 3 NDA-24307 Page 108 Issue 1 SYSTEM MESSAGES This message displays when I/O Ready Failure occurs in both HSW systems. ➀ HSW Fault Detected Note:When I/O ready failure ocurs simultaneously in both HSW systems, the [4-E] message is separately issued twice: “0” is displayed in one message and “1” in the other message. ➁ Details on HSW No. See Chapter 5 for repair procedure. 1: XXXX 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000 ➀ ➁ 4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000 b0 b4 b0 Default Alarm: MN4-EBoth HSW Ready FailureDefault Grade: 3Grade Modified: Lamp Modified: b0: 0/1 = No. 0 system/No. 1 system Note b0: 0/1 = -/Ready Fault in HSW b4: HSW No. (0-1)

NDA-24307 CHAPTER 3 Page 109 Issue 1 SYSTEM MESSAGES This message displays when I/O Ready Failure occurs in both HSW systems. ➀ HSW Fault Detected ➁ Details on HSW No. See Chapter 5 for repair procedure. 1: XXXX 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000 ➀ ➁ 4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000 b0 b4 b0 Default Alarm: MN4-FHSW Ready FailureDefault Grade: 3Grade Modified: Lamp Modified: b0: 0/1 = No. 0 system/No. 1 system b0: 0/1 = -/Ready Fault in HSW b4: HSW No. (0-1)

CHAPTER 3 NDA-24307 Page 110 Issue 1 SYSTEM MESSAGES This message displays when I/O Ready Failure occurs on a DLKC card. ➀Details on faulty DLKC card 1: XX00 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000 ➀ 4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000 b7 b0 Default Alarm: MN4-QDLKC Ready FailureDefault Grade: 3Grade Modified: Lamp Modified: b0: 0/1 = No. 0 system/No. 1 system b7: 0/1 = ACT/STBY

NDA-24307 CHAPTER 3 Page 111 Issue 1 SYSTEM MESSAGES This message displays when the MUX (PH-PC36) card has a Ready Failure in one of the dual systems. When the card is not ready for service function because of the failure or because the card is not mounted properly, the system creates this message. ➀Unit and MG number for the faulty MUX card ➁Faulty MUX card information See Chapter 5 for repair procedure. 1: XXXX 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000 ➀ ➁ 4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000 b7 b6 b5 b4 b3 b2 b1 b0 b2 b1 b0 Default Alarm: MN4-SMUX Ready FailureDefault Grade: 3Grade Modified: Lamp Modified: b0: 0/1 = -/Even-numbered MG, Unit 0 b1: 0/1 = -/Even-numbered MG, Unit 1 b2: 0/1 = -/Even-numbered MG, Unit 2 b3: 0/1 = -/Even-numbered MG, Unit 3 b4: 0/1 = -/Odd-numbered MG, Unit 0 b5: 0/1 = -/Odd-numbered MG, Unit 1 b6: 0/1 = -/Odd-numbered MG, Unit 2 b7: 0/1 = -/Odd-numbered MG, Unit 3 b0: MG 0/1 = Even number/Odd number b1: 0/1 = No. 0 system/No. 1 system b2: ACT or STBY status 0/1 = ACT/STBY

CHAPTER 3 NDA-24307 Page 112 Issue 1 SYSTEM MESSAGES This message displays when the MUX (PH-PC36) card has a Ready Failure in both of the dual systems. When the card is not ready for service function because of the failure or because the card is not mounted properly, the system creates this system message. ➀Unit and MG number for the MUX card ➁Faulty MUX card information Note 1:Though this message indicates the Ready Failure in both systems, the information displayed here only relates to the ACT-side MUX status. (Two messages are not displayed separately.) Note 2:Fi xe d as “0 (=ACT).” See Note 1. See Chapter 5 for repair procedure. 1: XXXX 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000 ➀ ➁ 4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000 b7 b6 b5 b4 b3 b2 b1 b0 b2 b1 b0 Default Alarm: MN4-TBoth MUX Ready FailureDefault Grade: 3Grade Modified: Lamp Modified: b0: 0/1 = -/Even-numbered MG, Unit 0 b1: 0/1 = -/Even-numbered MG, Unit 1 b2: 0/1 = -/Even-numbered MG, Unit 2 b3: 0/1 = -/Even-numbered MG, Unit 3 b4: 0/1 = -/Odd-numbered MG, Unit 0 b5: 0/1 = -/Odd-numbered MG, Unit 1 b6: 0/1 = -/Odd-numbered MG, Unit 2 b7: 0/1 = -/Odd-numbered MG, Unit 3 b0: MG 0/1 = Even number/Odd number b1: 0/1 = No. 0 system/No. 1 system Note 1 b2: ACT or STBY status Note 2 0/1 = ACT/STBY