    SYSTEM MESSAGES
    This message displays when a clock down failure occurs in the CCH/DCH circuit card. When this message is
    indicated, the related CCH/DCH card is placed into make-busy status
    .
    ➀ Location of faulty CCH/DCH card
    1: XX00 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀ 
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b7 b6 b5 b4 b3 b2 b1 b0
    Default Alarm:
    SUP13-ACCH Clock FailureDefault Grade:
    3Grade Modified: Lamp Modified:
    b0-b4: Group No. 
    b5, b6: Unit No. (0-3)
    b7: 0/1 = Even-numbered MG/Odd-numbered MG 
    						
    							CHAPTER 3 NDA-24307
    Page 184
    Issue 1
    SYSTEM MESSAGES
    This message displays when C-level infinite loop of the Port Microprocessor (PM) in the CCH/DCH circuit
    card has occurred
    .
    ➀ Location of faulty CCH/DCH card
    1: XX00 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀ 
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b7 b6 b5 b4 b3 b2 b1 b0
    Default Alarm:
    SUP13-BCCH C-Level Infinite Loop Failure (Permanent)Default Grade:
    3Grade Modified: Lamp Modified:
    b0-b4: Group No.
    b5, b6: Unit No. (0-3)
    b7: 0/1 = Even-numbered MG/Odd-numbered MG 
    						
    							NDA-24307 CHAPTER 3
    Page 185
    Issue 1
    SYSTEM MESSAGES
    This message displays when C-level infinite loop of the Port Microprocessor (PM) in the CCH/DCH circuit
    card has occurred
    .
    ➀ Location of faulty CCH/DCH card
    1: XX00 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀ 
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b7 b6 b5 b4 b3 b2 b1 b0
    Default Alarm:
    SUP13-CCCH C-Level Infinite Loop Failure (Temporary)Default Grade:
    1Grade Modified: Lamp Modified:
    b0-b4: Group No.
    b5, b6: Unit No. (0-3)
    b7: 0/1 = Even-numbered MG/Odd-numbered MG 
    						
    							CHAPTER 3 NDA-24307
    Page 186
    Issue 1
    SYSTEM MESSAGES
    This message displays when a Port Microprocessor (PM) of the CCH/DCH card did not send an answer to the
    CPU
    .
    ➀ Location of faulty CCH/DCH card
    1: XX00 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀ 
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b7 b6 b5 b4 b3 b2 b1 b0
    Default Alarm:
    SUP13-DCCH Lock-Up Failure (Permanent)Default Grade:
    3Grade Modified: Lamp Modified:
    b0-b4: Group No.
    b5, b6: Unit No. (0-3)
    b7: 0/1 = Even-numbered MG/Odd-numbered MG 
    						
    							NDA-24307 CHAPTER 3
    Page 187
    Issue 1
    SYSTEM MESSAGES
    This message displays when a Port Microprocessor (PM) of the CCH/DCH card did not send an answer to the
    CPU
    .
    ➀ Location of faulty CCH/DCH card
    1: XX00 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀ 
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b7 b6 b5 b4 b3 b2 b1 b0
    Default Alarm:
    SUP13-ECCH Lock-Up Failure (Temporary)Default Grade:
    1Grade Modified: Lamp Modified:
    b0-b4: Group No.
    b5, b6: Unit No. (0-3)
    b7: 0/1 = Even-numbered MG/Odd-numbered MG 
    						
    							CHAPTER 3 NDA-24307
    Page 188
    Issue 1
    SYSTEM MESSAGES
    This message displays when B-level infinite loop of the Port Microprocessor (PM) in the CCH/DCH circuit
    card has occurred
    .
    ➀ Location of faulty CCH/DCH card
    1: XX00 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀ 
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b7 b6 b5 b4 b3 b2 b1 b0
    Default Alarm:
    SUP13-FCCH B-Level Infinite Loop Failure (Permanent)Default Grade:
    3Grade Modified: Lamp Modified:
    b0-b4: Group No. 
    b5, b6: Unit No. (0-3)
    b7: 0/1 = Even-numbered MG/Odd-numbered MG 
    						
    							NDA-24307 CHAPTER 3
    Page 189
    Issue 1
    SYSTEM MESSAGES
    This message displays when B-level infinite loop of the Port Microprocessor (PM) in the CCH/DCH circuit
    card has occurred
    .
    ➀ Location of faulty CCH/DCH card
    1: XX00 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀ 
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b7 b6 b5 b4 b3 b2 b1 b0
    Default Alarm:
    SUP13-GCCH B-Level Infinite Loop Failure (Temporary)Default Grade:
    1Grade Modified: Lamp Modified:
    b0-b4: Group No. 
    b5, b6: Unit No. (0-3)
    b7: 0/1 = Even-numbered MG/Odd-numbered MG 
    						
    							CHAPTER 3 NDA-24307
    Page 190
    Issue 1
    SYSTEM MESSAGES
    This message displays when a failure has occurred numerous times to a common channel signaling link and
    the link has been placed into make-busy state
    .
    ➀ Location of Faulty CCH/DCH Card
    ➁ Data to be Analyzed by NEC 
    Engineers
    1: XXXX XX00 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀ ➁ ➂
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b7 b6 b5 b4 b3 b2 b1 b0
    b7 b6 b5 b4 b3 b2 b1 b0
    Default Alarm:
    SUP13-HCCS Link Failure (Permanent)Default Grade:
    1Grade Modified: Lamp Modified:
    b0-b4: Group No. 
    b5, b6: Unit No. (0-3)
    b7: 0/1 = Even-numbered MG/Odd-numbered MG 
    						
    							NDA-24307 CHAPTER 3
    Page 191
    Issue 1
    SYSTEM MESSAGES
    ➂ Probable cause for the failure
    b3 b2 b1 b0b0-b3: See Table:
    FLT IDCCITT 
    ERROR FA C TO R
    00 A S (F = 1) frame is received.
    01 B DM (F = 1) response is received.
    02 C UA (F = 1) response is received.
    03 D UA (F = 0) response is received.
    04 E DM (F = 0) response is received.
    05 F SABME command is received.
    06 G N200 Timeout (Link is set)
    07 HN200 Timeout (Link is 
    disconnected)
    08 IN200 Timeout (Link failure is 
    restored to normal)
    09 J N (R) frame error is received.
    0A KFRMR frame is received (Link is 
    re-setup).
    0B L Undefined frame is received.
    0C M -
    0D N Improper long frame is received.
    0E OI frame with I field which exceeds 
    N201 is received.
    0F - -
    10 - Layer 1 down (for ILC)
    40 -FRMR frame is received. (Link is 
    not re-setup) 
    						
    							CHAPTER 3 NDA-24307
    Page 192
    Issue 1
    SYSTEM MESSAGES
    This message displays when a failure has occurred numerous times to a common channel signaling link and
    the link has been placed into make-busy state. When this fault lasts over three minutes, the system message
    changes to [13-H] CCS Link Failure (Permanent)
    .
    ➀ Location of faulty CCH/DCH card
    ➁ Data to be Analyzed by NEC Engineers
    1: XXXX XX00 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀ ➁ ➂
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b7 b6 b5 b4 b3 b2 b1 b0
    b7 b6 b5 b4 b3 b2 b1 b0
    Default Alarm:
    NON13-ICCS Link Failure (Temporary)Default Grade:
    1Grade Modified: Lamp Modified:
    b0-b4: Group No.
    b5, b6: Unit No. (0-3)
    b7: 0/1 = Even-numbered MG/Odd-numbered MG 
    						