Home > NEC > Communications System > NEC Neax 2400 Ipx System Operations And Maintenance Manual

NEC Neax 2400 Ipx System Operations And Maintenance Manual

    Download as PDF Print this page Share this page

    Have a look at the manual NEC Neax 2400 Ipx System Operations And Maintenance Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 1168 NEC manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    Page
    of 724
    							NDA-24307 CHAPTER 6
    Page 503
    Issue 1
    SYSTEM OPERATIONS
    (3) Designated Connection Test Procedure
    (a) Register Test Procedure
    Figure 6-29   Register Test Procedure/Connection Diagram
    Access code is assigned by ASPA command, CI=N,
    SRV=SSC, SID=17
    Route numbers to be designated are as follows.:
    If any of the dialed numbers are not received correctly, a
    Reorder Tone (ROT) is heard.
    RT NUMBER
    902
    903
    TRUNK NAME
    Originating Register Trunk
    Incoming Register Trunk
    Hang Up
    TRUNK DESIGNATIONTEST IN PROGRESS
    REGISTER
    UNDER TEST
    ORT
    Note: If the Trunk Number of the next register is not assigned, the test ends.
    Lift handset
    (DT)
    Dial access code for 
    designated connection
    (DT)
    Dial “1,2,3,4,5,6,7,8,9,0” (*, # 
    in case of PB signal) 
    consecutively
    Is next register to 
    be tested, too?(NO)
    (YES)
    Make switch hook flash 
    Note
    + “9xx”
    RT No.“xxx”
    TRK No.
    (SST) 
    						
    							CHAPTER 6 NDA-24307
    Page 504
    Issue 1
    SYSTEM OPERATIONS
    (b) Sender Test Procedure
    Figure 6-30   Sender Test Procedure/Connection Diagram
    Access code is assigned by ASPA command, CI=N,
    SRV=SSC, SID=17
    Route number to be designated is as follows:
    If any of the dialed numbers are received correctly, a Reorder
    Tone (ROT) is heard.
    RT NUMBER
    905
    TRUNK NAME
    Sender Trunk DP/PB
    Note 1:After the sender to be tested is connected to the register, the sender sends out 1 ~ 9, 0 by DP
    signals and 1 ~ 9, 0, *, # by PB signals, thus checking to see if the dialed numbers are sent out
    correctly.
    Note 2:If the trunk number of the next sender is not assigned, the test ends.
    + “9xx”
    RT No.“xxx”
    TRK No. Lift handset
    Connection test is automatically
    Is next
    performed Note 1
    register to be
    tested, too?
    Make switch hook flash
    Note 2
    (DT)
    Dial access code for
    designated connection
    (Music On Hold)
    (SST)
    TRUNK DESIGNATION
    MUSIC ON
    HOLD
    ORT
    SNDTEST IN PROGRESS
    ORT
    DP
    OR PB
    YESNO
    Hang Up 
    						
    							NDA-24307 CHAPTER 6
    Page 505
    Issue 1
    SYSTEM OPERATIONS
    (c) 3-Party Conference Trunk Test Procedure
    Figure 6-31   3-Party Conference Test Procedure
    Note:If the trunk number of the next 3-Party Conference Trunk is not assigned, the test ends.
    Access code is assigned by ASPA command, CI=N,
    SRV=SSC, SID=17
      Route numbers to be designated are as follows:
    RT NUMBER
    909
    913
    TRUNK NAME
    3-party conference trunk
    (for station, ATTCON, trunk)
    3-party conference trunk
    (only for ATTCON)
    + “9xx”
    RT No.“xxx”
    TRK No. Lift handset
    Is next
    register to be
    tested, too?
    Make switch hook flash
    Note
    (DT)
    Dial access code for
    designated connection
    (SST)
    (SST)
    YESNO
    Hang Up As shown in Figure 6-32, 
    tone sending is repeated. 
    						
    							CHAPTER 6 NDA-24307
    Page 506
    Issue 1
    SYSTEM OPERATIONS
    Figure 6-32   3-Party Conference Test Connection Diagram
    TSTT TSTT TSTTTSTT TSTT TSTT ORTSST TRUNK DESIGNATION TEST IN PROGRESS
    1 SEC.1 SEC.1 SEC.1 SEC.
    1 SEC.
    1 SEC.
    1 SEC. 1 SEC.
    (DT) (SST) (DT)
    (SST) (DT) (SST) 
    						
    							NDA-24307 CHAPTER 6
    Page 507
    Issue 1
    SYSTEM OPERATIONS
    (d) Tone Test Procedure
    Figure 6-33   Tone Test Procedure/Connection Diagram
    Access code is assigned by ASPA command, CI=N, SRV=SSC,
    SID=17
      For Tone No. to be designated, refer to Table 6-7.
    Tone designated by Tone No. is heard.
    Lift handset
    (Tone)
    Dial access code for
    designated connection
    Dial   “x x”
    Tone Number
    Dial “000”
    (DT)
    Hang Up(DT)TRUNK DESIGNATIONTEST IN PROGRESS
    ORT ORTTONE 
    						
    							CHAPTER 6 NDA-24307
    Page 508
    Issue 1
    SYSTEM OPERATIONS
    Table 6-7  Tone Numbers
    Tone No. Kind Of Tone Remarks
    00 Dial Tone (DT)
    01 Special Dial Tone (SPDT)
    02 Ring Back Tone (RBT)
    03Continuous Ring Back Tone (CRBT)
    04 Busy Tone (BT)
    05 Reorder Tone (ROT)
    06 Service Set Tone (SST)
    07 Second Dial Tone (SDT)
    08 No Tone
    09 Sender Transmitting Tone (SDTT)
    10 Call Waiting Ring Back Tone (CWRBT)
    11 No Tone
    12 No Tone
    1 3 Te s t  To n e  ( T S T T )
    14 Music On Hold (MSC)
    15 No Tone 
    						
    							NDA-24307 CHAPTER 6
    Page 509
    Issue 1
    SYSTEM OPERATIONS
    (e) Interrupt Ringing (IR) Test Procedure
    Figure 6-34   Interrupt Ringing (IR) Test Procedure/Connection Diagram
    AAA A
    ORTIR SST
    Access code is assigned by ASPA command, CI=N, SRV=SSC,
    SID=17
    Lift handset
    Dial access code for
    designated connection
    (SST)
    (DT)
    TEST IN PROGRESSDESIGNATION
    Dial “999”
    Hang Up
    Bell Rings
    Lift handset and answer
    (SST)
    Hang Up
    HANGUPSST
    ANSWER 
    						
    							CHAPTER 6 NDA-24307
    Page 510
    Issue 1
    SYSTEM OPERATIONS
    (f) Trunk Test Procedure
    Figure 6-35   Trunk Test Procedure
    Note:If the trunk number of the next trunk is not assigned, the test ends.
      Access code is assigned by ASPA command, CI=N,
    SRV=SSC, SID=17
    + “9xx”
    RT No.“xxx”
    TRK No. Lift handset
    Is next
    register to be
    tested, too?
    Make switch hook flash
    Note
    (DT)
    Dial access code for
    designated connection
    (RBT)
    YESNO
    Dial the called party
    number
    The called party at the
    distant office answers
    and talks
    Hang Up 
    						
    							NDA-24307 CHAPTER 6
    Page 511
    Issue 1
    SYSTEM OPERATIONS
    Figure 6-36   Trunk Test Connection Diagram
    A
    ORT
    TRUNK DESIGNATIONCALLED PARTY DIALINGCALLED PARTY DIALING
    NUMBER SENDINGCALLED PARTY DIALING
    TRKA AA A A2nd DT SYSTEM
    CHARGING SERVICE
    PROVIDED SENDER
    SYSTEM
    SND
    TRK
    ORT
    ORT
    TRK 
    						
    							CHAPTER 6 NDA-24307
    Page 512
    Issue 1
    SYSTEM OPERATIONS
    10.2 Designated Connection Test (DESKCON/ATTCON)
    (1) General
    The purpose of this test is to confirm the operations related to a trunk which has been designated from the
    DESKCON/ATTCON.
    (2) Test Procedure
    (a) Trunk seizure with TKSL key
    Whether dialing RT No. + TRK No. 
    OR 
    Dialing C.O. Line NO. is determined per ASYD
    command, SYS1. INDEX68. b1.
    C.O. Line No. is assigned by ACOC command.
    Press TKSL or TRKSL key
    (RBT)
    + “xxx”
    RT No.“xxx”
    TRK No.
    or
    “xxxx”
    C.O. Line NO.
    Dial the called party
    number
    Press CANCEL key
    The called party at the
    and talks distant office answers(DT from Distant Office) 
    						