    SYSTEM MESSAGES
    This message displays when a VPS failure is detected.
    ➀ Probable cause for the failure
    ➁ LENS of VPS
    ➂ LENS of VPS
    1: XXXX XX00 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀ ➁ ➂
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b7 b6 b5 b4 b3 b2 b1 b0
    b7 b6 b5 b4 b3 b2 b1 b0
    b7 b6 b5 b4 b3 b2 b1 b0
    Default Alarm:
    MN15-BVPS Failure (Permanent)Default Grade:
    2Grade Modified: Lamp Modified:
    b0-b7: 0 = -
    01H = Sector error
    FF = Other than above
    b0-b2: Level
    b3-b7: Group
    b0, b1: Unit
    b2-b7: Module Group 
    						
    							CHAPTER 3 NDA-24307
    Page 204
    Issue 1
    SYSTEM MESSAGES
    This message displays when a VPS failure, observed in the message [15-B], is restored to normal.
    ➀ LENS of VPS
    ➁ LENS of VPS
    1: XXXX 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀ ➁
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b7 b6 b5 b4 b3 b2 b1 b0
    b7 b6 b5 b4 b3 b2 b1 b0
    Default Alarm:
    NON15-CVPS RestoreDefault Grade:
    2Grade Modified: Lamp Modified:
    b0-b2: Level
    b3-b7: Group
    b0, b1: Unit
    b2-b7: Module Group 
    						
    							NDA-24307 CHAPTER 3
    Page 205
    Issue 1
    SYSTEM MESSAGES
    This message displays when Intra-Office Trunks (ATI, RST, etc.) have all become busy.
    ➀ Details on Trunk name and its 
    Route number
    1: XX00 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀ 
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b7 b6 b5 b4 b3 b2 b1 b0
    Default Alarm:
    SUP16-AInside Trunk All BusyDefault Grade:
    3Grade Modified: Lamp Modified:
    See table on the following page 
    						
    							CHAPTER 3 NDA-24307
    Page 206
    Issue 1
    SYSTEM MESSAGES
    ROUTE 
    NO.DATA  
    (HEX.)TRUNK NAMEROUTE 
    NO.DATA 
    (HEX.)TRUNK NAME
    901 01 Attendant Console 917 11 MFC Sender
    902 02 Originating Register Trunk 918 12 Not used
    903 03 Incoming Register Trunk 919 13 MODEM
    904 04 MF Receiver 920 14 MODEM
    905 05 Sender Trunk DP/PB 921 15 MODEM
    906 06 PB Receiver for Automated
    Attendant Service922 16 MODEM
    907 07 AMP 923 17 MODEM
    908 08 Not used 924 18 MODEM
    909 09 Three-Way Conference Trunk 925 19 MODEM
    910 0A Not used 926 1A MODEM
    911 0B Not used 927 1B Not used
    912 0C Originating Register Trunk for 
    ATTCON/DESKCON928 1C Not used
    913 0D Three-Way Conference Trunk for 
    ATTCON/DESKCON929 1D Data Signaling Trunk-Option
    914 0E Not used 930 1E Rate Adaptation Conversion Trunk
    915 0F Night ATTCON/DESKCON 931 1F Not used
    916 10 MFC Register 
    						
    							NDA-24307 CHAPTER 3
    Page 207
    Issue 1
    SYSTEM MESSAGES
    This message displays when Virtual Tie Line setup has completed.
    ➀ Counter
    ➁ Virtual Tie Line Call Header 
    Location
    ➂ Virtual Tie Line Call Header 
    Location
    1: XXXX XX00 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀ ➁ ➂
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b7 b6 b5 b4 b3 b2 b1 b0
    b2 b1 b0
    b7 b6 b5 b4 b3 b2 b1 b0
    Default Alarm:
    NON16-BVirtual Tie Line Set ReportDefault Grade:
    3Grade Modified: Lamp Modified:
    b0: 00=-
    01=Re-setup
    b0,b1: Unit No.
    b2: Module Group No.
    b0-b2:  Level
    b3-b7:  Group No. 
    						
    							CHAPTER 3 NDA-24307
    Page 208
    Issue 1
    SYSTEM MESSAGES
    This message displays when Virtual Tie Line Cancel has completed.
    ➀ Counter
    ➁ Virtual Tie Line Call Header 
    Location
    ➂ Virtual Tie Line Call Header 
    Location
    1: XXXX XX00 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀ ➁➂
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b0
    b2 b1 b0
    b7 b6 b5 b4 b3 b2 b1 b0
    Default Alarm:
    NON16-CVirtual Tie Line Cancel ReportDefault Grade:
    3Grade Modified: Lamp Modified:
    b0: 0/1=-/Re-setup
    b0,b1: Unit No.
    b2: Module Group No.
    b0-b2: Level
    b3-b7: Group No. 
    						
    							NDA-24307 CHAPTER 3
    Page 209
    Issue 1
    SYSTEM MESSAGES
    This message displays when Virtual Tie Line Setup has failed due to a fault in the network of the terminating
    office concerned.
    ➀ Virtual Tie Line Call Header 
    Location
    ➁ Virtual Tie Line Call Header 
    Location
    1: 00XX XX8X XXXX 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀
    ➁ ➂ ➃ ➄
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b2 b1 b0
    b7 b6 b5 b4 b3 b2 b1 b0
    Default Alarm:
    NON16-EVirtual Tie Line Set Time OutDefault Grade:
    1Grade Modified: Lamp Modified:
    b0,b1: Unit No.
    b2: Module Group No. 
    b0-b2: Level
    b3-b7: Group No. 
    						
    							CHAPTER 3 NDA-24307
    Page 210
    Issue 1
    SYSTEM MESSAGES
    ➂ Virtual Tie Line Call Header 
    Location
    ➃ Fault Cause b7 b6 b5 b4 b3 b2 b1 b0
    b6 b5 b4 b3 b2 b1 b0
    CLASS
    REASON 
    KIND 
    VA L U E
    DATAREASON KIND
     Reason Kind
    Class Value
    XX
    8765
    4321(bit)
    -000
    xxxx
    -001
    Normal Event Class000
    000
    000
    000
    000
    001
    001
    001
    001
    001
    001
    001 
    001
    001
    001
    001
    0010001
    0010
    0011
    0110
    0111
    0000
    0001
    0010
    0011
    0101
    0110
    1010
    1011
    1100
    1101
    1110
    11111
    2
    3
    6
    7
    16
    17
    18
    19
    21
    22
    26
    27
    28
    29
    30
    31Dead Number
    No route to the designated transit network
    No route to the opposite Party
    Use of channel not allowed
    Call terminated to a setup channel
    Normal disconnection
    Called user busy
    No response from called user
    Called party being rung/no answer
    Communication denied
    Opposite party’s terminal number changed
    Disconnection and release of the user not selected
    Opposite party’s terminal out of order
    Invalid number format (Incomplete Number)
    Facility denied
    Answer to status inquiry
    Other normal class
    b0-b3: Call Source
    b4-b7:“8” is always indicated. DATA CALL SOURCE
    0User
    1 Private network to which the user is directly connected. 
    (Self side)
    2 National network to which the user is directly connected. 
    (Self side)
    3 Tie-Line Network
    4 National network to which the opposite party is directly 
    connected. (Opposite party’s side)
    5 Private network to which the opposite party is directly 
    connected. (Opposite party’s side)
    7 International Network
    A Network from Interworking
    Other Spare
    b0-b3: Reason Kind
    b4-b6: Class
    0=No Answer 
    Other than 0=Refer to the following table 
    						
    							NDA-24307 CHAPTER 3
    Page 211
    Issue 1
    SYSTEM MESSAGES
    010 xxxx
    Classes not allowed use of resources010
    010
    010
    010
    010
    010
    0100010
    0110
    1001
    1010
    1011
    1100
    111134
    38
    41
    42
    43
    44
    47No usable channel/line
    Network failure
    Temporary failure
    Switching system congested
    Access information discarded
    Use of requested line/channel not allowed
    Class not allowed use of other resources
     Reason Kind
    Class Value
    XX
    8765
    4321(bit)
    011 xxxx
    Classes not allowed use of services011
    011
    011
    011
    0110001
    0010
    1001
    1010
    111149
    50
    57
    58
    63Use of QOS not allowed
    Requested facility not contracted
    Bearer capability not allowed
    Bearer capability not allowed at present
    Class not allowed to use other services or options
    100 xxxx
    Classes not provided with services100
    100
    100
    100
    1000001
    0010
    0101
    0110
    111165
    66
    69
    70
    79Unprovided bearer capability designated
    Unprovided channel kind designated
    Unprovided facility requested
    Restricted digital information bearer capability
    Class unprovided with other services or options
    101 xxxx
    Invalid message class
    001
    101
    101
    101
    101
    101 
    101
    101
    1010001
    0010
    0011
    0100
    0101
    0110
    1000
    1011
    111181
    82
    83
    84
    85
    86
    88
    91
    95Invalid call number used
    Invalid channel number used
    Designated transit call ID number unused
    Transit call ID number being used
    No transit call
    Designated transit call disconnected and released
    Terminal attributes unmatch
    Invalid transit network selected
    Other invalid message class
    110    xxxx
    Procedure error (ex: unrecognized 
    message) class110
    110
    110
    110
    110
    110
    110
    1100000
    0001
    0010
    0011
    0100
    0101
    0110
    111196
    97
    98
     
    99
    100
    101
    102
    111Mandatory information elements inadequate
    Message kind undefined or unprovided
    Call status and message unmatching or message 
    kind undefined
    Information element undefined
    Content of information element invalid
    Call status and message unmatching
    Recovery due to timer over
    Class of other procedure errors
    111     xxxx 
    Interworking class111 111 127 Other interworking class
    Others Reserved
    CLASS
    REASON 
    KIND 
    VA L U E
    DATAREASON KIND 
    						
    							CHAPTER 3 NDA-24307
    Page 212
    Issue 1
    SYSTEM MESSAGES
    This message indicates that an outgoing call (by connection acknowledge system) has not received an
    acknowledgment signal from the opposite office. As a result, the attempted outgoing call is routed to Reorder
    Tone (ROT) connection.
    In Case of Station OG/ATT OG/ATT Tandem Connection
    ➀ Type of connection and station 
    number digits
    ➁ ~ ➃ Calling station number
    (See table)
    1: XXXX XXXX XX0X XX0X 2: XXXX XXXX XXXX XXXX 3: XXXX XXXX XXXX XXXX
    12➀ ➁ ➂  ➃ ➄ ➅ ➆ ➇ ➈ ➉11 12
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b7 b6 b2 b1 b0
    b7 b6 b5 b4 b3 b2 b1 b0
    Default Alarm:
    NON16-FSender Start Time OutDefault Grade:
    0Grade Modified: Lamp Modified:
    b0-b2: Digits of station number (origination)
    b6
    -b7: 
    0 0 = Station OG connection
    0 1 = ATT OG connection
    1 1 = ATT Tandem connection
    b4-b7 b0-b3
    ➁DC0 DC1
    ➂DC2 DC3
    ➃DC4 DC5 
    						
    All NEC manuals Comments (0)

    Related Manuals for NEC Neax 2400 Ipx System Operations And Maintenance Manual