    							NDA-24307 CHAPTER 3
    Page 73
    Issue 1
    SYSTEM MESSAGES
    This message displays when the system detects any failure at the HSW in both systems.
    ➀ HSW detected as faulty
    ➁ System status at the time of fault 
    detection
    ➂ Wire Address
    ➃ Write Data
    ➄ Read Data
    See Chapter 5 for repair procedure.
    1: XXXX XXXX XXXX XX00 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀ ➁ ➂ ➃➄
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b0
    b7 b6 b4 b3 b2 b0
    Default Alarm:
    MN1-GBoth HSW FailureDefault Grade:
    3Grade Modified: Lamp Modified:
    b0: 0/1 = No. 0 system / No. 1 system
    b0: HSW No. (0-1)
    b2-b3: Kind of TSW
    10 = Second Switching
    b4: HSW No. (0-1)
    b6: Speech Path in ACT state 
    0/1 = No. 0 system/No. 1 system
    b7: Base clock in ACT state
    Data analyzed by NEC Engineers. 
    						
    							CHAPTER 3 NDA-24307
    Pag e 7 4
    Issue 1
    SYSTEM MESSAGES
    This message displays when the system detects any failure at the HSW in one of the dual systems.
    ➀ HSW detected as faulty
    ➁ System status at the time of fault 
    detection
    ➂ Wire Address
    ➃ Write Data
    ➄ Read Data
    See Chapter 5 for repair procedure.
    1: XXXX XXXX XXXX XX00 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀ ➁ ➂ ➃➄
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b0
    b7 b6 b4 b3 b2 b0
    Default Alarm:
    MN1-HHSW FailureDefault Grade: Grade Modified: Lamp Modified:
    b0: 0/1 = No. 0 system / No. 1 system
    b0: HSW No. (0-1)
    b2-b3: Kind of TSW
    10 = Second Switching
    b4: HSW No. (0-1)
    b6: Speech Path in ACT state 
    0/1 = No. 0 system/No. 1 system
    b7: Base clock in ACT state
    Data analyzed by NEC Engineers. 
    						
    							NDA-24307 CHAPTER 3
    Page 75
    Issue 1
    SYSTEM MESSAGES
    This message displays when the link information cannot be written into the switch memory of the HSW card
    in both systems.
    ➀ HSW detected as faulty
    ➁ System status at the time of fault 
    detection
    ➂ Wire Address
    ➃ Write Data
    ➄ Read Data
    See Chapter 5 for repair procedure.
    1: XXXX XXXX XXXX XX00 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀ ➁ ➂ ➃➄
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b0
    b7 b6 b4 b3 b2 b0
    Default Alarm:
    MN1-IBoth HSW Write FailureDefault Grade:
    2Grade Modified: Lamp Modified:
    b0: 0/1 = No. 0 system / No. 1 system
    b0: HSW No. (0-1)
    b2-b3: Kind of TSW
    10 = Second Switching
    b4: HSW No. (0-1)
    b6: Speech Path in ACT state 
    0/1 = No. 0 system/No. 1 system
    b7: Base clock in ACT state
    Data analyzed by NEC Engineers. 
    						
    							CHAPTER 3 NDA-24307
    Pag e 7 6
    Issue 1
    SYSTEM MESSAGES
    This message displays when the link information cannot be written into the switch memory of the HSW card
    in one of the dual systems.
    ➀ HSW detected as faulty
    ➁ System status at the time of fault 
    detection
    ➂ Wire Address
    ➃ Write Data
    ➄ Read Data
    See Chapter 5 for repair procedure.
    1: XXXX XXXX XXXX XX00 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀ ➁ ➂ ➃➄
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b0
    b7 b6 b4 b3 b2 b0
    Default Alarm:
    MN1-JHSW Write FailureDefault Grade:
    2Grade Modified: Lamp Modified:
    b0: 0/1 = No. 0 system / No. 1 system
    b0: HSW No. (0-1)
    b2-b3: Kind of TSW
    10 = Second Switching
    b4: HSW No. (0-1)
    b6: Speech Path in ACT state 
    0/1 = No. 0 system/No. 1 system
    b7: Base clock in ACT state
    Data analyzed by NEC Engineers. 
    						
    							NDA-24307 CHAPTER 3
    Page 77
    Issue 1
    SYSTEM MESSAGES
    This message displays when the system detects a clock failure such as HSW internal clock down or Frame
    Head down in both systems.
    ➀ HSW detected as faulty
    ➁ Details on failure
    ➂ Clock status of No. 0 HSW
    1: XXXX XXXX XXXX 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀ ➁ ➂ ➃
    ➄ 
    ➅
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b0
    b4 b0
    b3 b1 b0
    Default Alarm:
    MN1-KBoth HSW CLK FailureDefault Grade:
    3Grade Modified: Lamp Modified:
    b0: 0/1 = No. 0 system / No. 1 system
    b0: 0/1 = -/Clock failure in HSW
    b4: HSW No. (0-1)
    b0: 0/1 = -/HSW card internal clock down
    b1: 0/1 = -/External 32 ch Clock (PLO) down
    b3: 0/1 = -/Frame Head Return down 
    						
    							CHAPTER 3 NDA-24307
    Pag e 7 8
    Issue 1
    SYSTEM MESSAGES
    ➃ Clock status of No. 1 HSW
    Note:Refer to the meaning of ➂.
    ➄ Clock status of No. 2 HSW
    Note:Refer to the meaning of ➂.
    ➅ Clock status of No. 3 HSW
    Note:Refer to the meaning of ➂.
    See Chapter 5 for repair procedure. 
    						
    							NDA-24307 CHAPTER 3
    Page 79
    Issue 1
    SYSTEM MESSAGES
    This message displays when the system detects a clock failure such as HSW internal clock down or Frame
    Head down in both systems.
    ➀ HSW detected as faulty
    ➁ Details on failure
    ➂ Clock status of No. 0 HSW
    1: XXXX XXXX XXXX 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀ ➁ ➂ ➃
    ➄ ➅
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b0
    b4 b0
    b3 b1 b0
    Default Alarm:
    MN1-LHSW CLK FailureDefault Grade:
    3Grade Modified: Lamp Modified:
    b0: 0/1 = No. 0 system / No. 1 system
    b0: 0/1 = -/Clock failure in HSW
    b4: HSW No. (0-1)
    b0: 0/1 = -/HSW card internal clock down
    b1: 0/1 = -/External 32 ch Clock (PLO) down
    b3: 0/1 = -/Frame Head Return down 
    						
    							CHAPTER 3 NDA-24307
    Pag e 8 0
    Issue 1
    SYSTEM MESSAGES
    ➃ Clock status of No. 1 HSW
    Note:Refer to the meaning of ➂.
    ➄ Clock status of No. 2 HSW
    Note:Refer to the meaning of ➂.
    ➅ Clock status of No. 3 HSW
    Note:Refer to the meaning of ➂.
    See Chapter 5 for repair procedure. 
    						
    							NDA-24307 CHAPTER 3
    Page 81
    Issue 1
    SYSTEM MESSAGES
    This message displays when the system detects a fault, such as input clock all down or output clock down in
    the PLO/CLK cards (both systems).
    ➀ Detected PLO number
    Note 1:For CLK in TSWM1 (used in LN only).
    Note 2:For PLO in TSWM0 (used in LN only).
    ➁ Valid Information bit for Scan 
    Data 1
    ➂ Valid Information bit for Scan 
    Data 2
    See Chapter 4 for the Circuit Card Replacement Procedure.
    1: XXXX XXXX XX00 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀ ➁ ➂ ➃ ➄
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b7 b6 b0
    b7 b6 b5 b4 b3 b2 b1 b0
    b7 b6 b5 b4 b3 b2 b1 b0
    Default Alarm:
    MJ1-OBoth PLO FailureDefault Grade:
    3Grade Modified: Lamp Modified:
    b0: 0/1 = No. 0 PLO/No. 1 PLO
    b6: 0/1 = -/CLK card failure Note 1
    b7: 0/1 = -/PLO card failure Note 2
    b0-b7: The bit position corresponding to the detected information in Scan 
    Data 1 ( ) is flagged “1”.
    ➃
    b0-b7: The bit position corresponding to the detected information in Scan 
    Data 2 ( ) is flagged “1”.
    ➄ 
    						
    							CHAPTER 3 NDA-24307
    Pag e 8 2
    Issue 1
    SYSTEM MESSAGES
    ➃ Scan Data 1: Current Status of the 
    PLO card
    ➄ Scan Data 2: Current status of the 
    PLO card
    Note 1:The clock status includes that of PH-CK18 (CLK) card.
    Note 2:This information includes the failure detected in PH-CK18 (CLK) card. b7 b6 b5 b4 b3 b2 b1 b0
    b4 b1 b0
    b0: Clock status at the time of detection Note 1
    0/1 = STBY/ACT
    b1: Circuit Card status at the time of detection
    0/1 = PLO synchronizing/PLO self running or drifting
    b2: 0/1 = -/Input clock down
    b3, b4: Route of Input clock 
    b5: 0/1 = -/PLO input all down
    b6: 0/1 = -/PLO output down Note 2
    b7: 0/1 = -/Drifting
    b3b4DCS Input RouteRoute of Input Clock
    00 0 0
    01 1 1
    10 - 2
    11 - 3
    b0: 0/1 = -/5msec Burst Clock down
    b1: 0/1 = -/Frame Synchronization from SYNC card is down
    b4: 0/1 = -/Internal OSC clock down 
    						