    							NDA-24307 CHAPTER 4
    Page 283
    Issue 1
    UNIT/CIRCUIT CARD REPLACEMENT PROCEDURE
    (5) Insert the new HFD (PZ-IO27) into the CPR. Then, fasten the two screws as shown in
    Figure 4-8. 
    Figure 4-8   Insertion of New HFD Into CPR
    ATTENTIONContents
    Static Sensitive
    Handling
    Precautions Required
    LPM
    HFD (PZ-IO27/PZ-IO28) 
    						
    							CHAPTER 4 NDA-24307
    Page 284
    Issue 1
    UNIT/CIRCUIT CARD REPLACEMENT PROCEDURE
    (6) Make sure Switch 8 of SYSTEM SELECT 1 (DIP Switch) on each CPU Front Panel
    is set to ON. (Do this for all LNs and ISW: Refer to Figure 4-9.)
    Figure 4-9   Switch Setting on the CPU Front Panel
    ATTENTIONContents
    Static Sensitive
    Handling
    Precautions Required
    12
    34
    567
    8
    OFF
    12
    34
    OFF
    MBR
    FDD ON
    OFF
    PALM
    ON
    OFF OUT PWR
    IN PWR5AHDD SW
    MB
    SYSTEM SELECT0
    SENSE
    SYSTEM SELECT2
    CPURST
    SLOT No.    0 1 2 3 4 5 6 STATUS IMG1 IMG2 IMG3 CPUOPE
    WDTIMG0
    ON
    ON
    SYSTEM SELECT112
    34
    567
    8
    OFFON4C026AE
    12
    34
    567
    8
    OFF
    12
    34
    567
    8
    OFF
    12
    34
    OFF
    MBR
    FDD ON
    OFF
    ON
    OFF OUT PWR
    IN PWR5AHDD SW
    MB
    SYSTEM SELECT0
    SENSE SYSTEM SELECT1
    SYSTEM SELECT2
    CPURST
    SLOT No.    0 1 2 3 4 5 6 STATUS IMG1 IMG2 IMG3 CPUOPE
    WDTIMG0
    ON
    ON
    ON4C026AE
    00 01 02 03 04
    MMC (PH-M22) MISC/IOC IOC(PH-IO24) EMA(PH-PC49)
    MISC
    LPMCPR1
    LANI(PZ-PC19)ISAGT(PZ-GT13)
    ISAGT(PZ-GT20)
        
    Note
    PALMCPR0
    FRONT VIEW
    Note:  PZ-GT20 card is mounted in LN only.SYSTEM SELECT1
    12
    34
    567
    8
    OFF
    ON 
    						
    							NDA-24307 CHAPTER 4
    Page 285
    Issue 1
    UNIT/CIRCUIT CARD REPLACEMENT PROCEDURE
    1.3.2 EMA Card Replacement Procedure
    The EMA (PH-PC40) card is mounted in slot No. 04 of the LPM. The main
    functions of the card are as follows:
    Designation of ACT/STBY status of the CPU and forced changeover of the
    system
    Shutoff of the system’s power supply and detection of rising temperature within the system
    Control of the NCU (PA-M53) card
    Replacement Procedure
    ATTENTIONContents
    Static Sensitive
    Handling
    Precautions Required
    ATTENTIONContents
    Static Sensitive
    Handling
    Precautions Required
    Before replacing the EMA card, check the CPU 0’s ACT mode. Attempting to replace the card
    when the CPU 1 is active will result in the system being initialized.WAR NI NG
    Check the CPU OPE lamp of DSP 1. 
    When the lamp is steady-green, 
    perform the system changeover.
    OPE/MB Lamp on the EMA card 
    lights red from green.
    When NCU (PA-M53) cards are 
    mounted, Power Failure Transfer 
    (PFT) is activated.
    Turn ON the MB key on the EMA (PH-PC40) card.
    A Flip the MBR key on the DSP 1 (ON
    (System Changeover of CPU 1: ACT        STBY)
    Extract the EMA card from the LPM.
    CPU 1 is Active?
    YES NO
    OFFON 
    						
    							CHAPTER 4 NDA-24307
    Page 286
    Issue 1
    UNIT/CIRCUIT CARD REPLACEMENT PROCEDURE
    ATTENTIONContents
    Static Sensitive
    Handling
    Precautions Required
    OPE/MB Lamp on the EMA card 
    lights steady-green.
    The PFT service is cancelled: 
    resumption of normal operation.
    Turn ON the MB and EMA SUP keys on the
    new card.
    Turn OFF the MB and EMA SUP keys on the card.
    Assign the time data by using the ATIM/ATIMN
    END
    A
    Set the keys on the new card by referring to the 
    Insert the new card into the LPM.card being replaced.
    command. 
    						
    							NDA-24307 CHAPTER 4
    Page 287
    Issue 1
    UNIT/CIRCUIT CARD REPLACEMENT PROCEDURE
    1.3.3 IOC Card Replacement Procedure
    The IOC (PH-IO24) card is mounted in slot No. 02 and/or 03 of the LPM. The
    card’s main function is to provide a serial interface between the system and its
    external equipment, such as the Maintenance Administration Terminal (MAT),
    Station Message Detail Recording System (SMDR), Message Center Interface
    (MCI), Property Management System (PMS), etc.
    AT T E N T I O NContents
    Static Sensitive
    Handling
    Precautions Required
    OPE lamp on the IOC card first 
    flashes and then lights red.
    All I/O ports are closed and the 
    equipment, such as MAT and SMDR, 
    loses connections.
    Note:The text data (such as bill-
    ing information), registered
    before this step, will be
    safely transmitted later.
    However, the data, recorded
    after this step, will not be
    sent out, and instead is
    stored in the buffer.
    OPE lamp on the IOC card goes OFF.
    Extract the card from the LPM.
    A Turn ON the MB key on the card.
    Turn ON the MBR key on the IOC (PH-IO24)
    card to be replaced.
    Set the keys on the new card, referring to the
    card to be replaced.
    START
    The equipment connected to the I/O ports of each card (MAT, SMDR, etc.) cannot be used while
    replacing the IOC card.AT T E N T I O N 
    						
    							CHAPTER 4 NDA-24307
    Page 288
    Issue 1
    UNIT/CIRCUIT CARD REPLACEMENT PROCEDURE
    ATTENTIONContents
    Static Sensitive
    Handling
    Precautions Required
    OPE lamp on the IOC card lights 
    red.
    Release of I/O ports: new IOC card 
    is initialized, and I/O port channels 
    reopens.
    OPE lamp lights green.
    Turn OFF the MB key on the card.
    END Insert the new card into the LPM.
    Turn ON  the MB and MBR keys on the 
    new card.
    Turn OFF the MBR key on the card.
    A 
    						
    							NDA-24307 CHAPTER 4
    Page 289
    Issue 1
    UNIT/CIRCUIT CARD REPLACEMENT PROCEDURE
    1.3.4 Power Supply Unit Replacement Procedure
    ATTENTIONContents
    Static Sensitive
    Handling
    Precautions Required
    CPU System 
    Changeover
    Refer to Section 12, 
    Chapter 6.
    Cable to be disconnected from OUTPWR
    CPU 0: 6P-(4P-3P) PWR CA-A
    CPU 1: 6P-(4P-3P) PWR CA-B
    START
    Set the mode of the PWR UNIT (PZ-PW92)
    to be replaced into STBY mode.
    On the EMA (PH-PC40) card, set EMA SUP
    switch UP.
    Turn OFF the SW key on the PWR UNIT.
    Disconnect the power cables from the OUTPWR
    connector and INPWR connector on the PZ-PW92.
    A
    Disconnect the power alarm cable from the 
    PALM connector on the PZ-PW92.
    Cable Name to be disconnected
    CPU 0: 10AL-(110) FLT CA
    CPU 1: 10AL-(130) FLT CA
    Cable to be disconnected from INPWR
    CPU 0: 4P-2P PWR CA-A
    CPU 1: 4P-2P PWR CA-B
    PWR (PZ-PW92)
    FRONT VIEW
    SW
    ON
    OFF
    PALM -48V
    ON
    ALM OUTPWR
    INPWR 
    						
    							CHAPTER 4 NDA-24307
    Page 290
    Issue 1
    UNIT/CIRCUIT CARD REPLACEMENT PROCEDURE
    ATTENTIONContents
    Static Sensitive
    Handling
    Precautions Required
    END Insert the new PWR UNIT into the CPR.
    Unscrew the PWR UNIT from the CPR.
    Turn ON the SW key on the PWR UNIT.
    A
    On the EMA card, set EMA SUP switch DOWN.
    Reattach power alarm cable to the PALM 
    connector on the PZ-PW92.Reattach power cables to OUTPWR
    and INPWR connectors on the PZ-PW92. 
    						
    							NDA-24307 CHAPTER 4
    Page 291
    Issue 1
    UNIT/CIRCUIT CARD REPLACEMENT PROCEDURE
    1.3.5 MISC Card Replacement Procedure
    ATTENTIONContents
    Static Sensitive
    Handling
    Precautions Required
    Keep MB switch UP.
    END Extract the MISC card from its mounting slot.
    On the MISC card, set MB switch UP.
    On the MISC card, set MB switch DOWN.
    START
    Insert the new circuit card into the same 
    mounting slot. 
    						
    							CHAPTER 4 NDA-24307
    Page 292
    Issue 1
    UNIT/CIRCUIT CARD REPLACEMENT PROCEDURE
    1.3.6 MMC Card Replacement Procedure
    The MMC (PH-M22) card is mounted in slot No. 00 of the LPM. The card’s main
    functions are:
    To collect key setting information on the TOPU of each LN/ISW. 
    Note
    To collect alarm information on LN or the entire system (in case of MMC in
    ISW), thereby activating MJ/MN LED on the TOPU display.
    Note:If the key setting affects the entire system (i.e. the SYSTEM side is selected by the INITIAL SELECT key
    on the ISW TOPU). The information is broadcast to the MMC of ISW including the MMC of all existing
    LNs.
    Replacement Procedure
    AT T E N T I O NContents
    Static Sensitive
    Handling
    Precautions Required
    OPE lamp on the MMC goes off.
    A Disconnect the cable from the KEY connector
    Set the MB key to UP on the MMC (PH-M22)
    START
    card the be replaced.
    on the MMC card.
    Cable to be disconnected
    10AL-(400) FLT CA
    Disconnect the whole cable(s) from the CNx
    connector(s) on the MMC card.
    Cable to be disconnected
    MT24 MISC CA-n
    Extract the MMC card from the LPM.Note:
    The connector and cable
    names vary depending on
    it’s connecting conditions. 
    						
    All NEC manuals Comments (0)