    							NDA-24307 CHAPTER 3
    Page 193
    Issue 1
    SYSTEM MESSAGES
    ➂ Probable cause for the failure
    b3 b2 b1 b0b0-b3: See Table.
    FLT IDCCITT 
    ERROR FAC TO R
    00 A S (F = 1) frame is received.
    01 B DM (F = 1) response is received.
    02 C UA (F = 1) response is received.
    03 D UA (F = 0) response is received.
    04 E DM (F = 0) response is received.
    05 F SABME command is received.
    06 G N200 Timeout (Link is set)
    07 H N200 Timeout (Link is disconnected)
    08 I N200 Timeout (Link failure is restored 
    to normal)
    09 J N (R) frame error is received.
    0A K FRMR frame is received (Link is 
    re-setup).
    0B L Undefined frame is received.
    0C M -
    0D N Improper long frame is received.
    0E O I frame with I field which exceeds 
    N201 is received.
    0F - -
    10 - Layer 1 down (for ILC)
    40 - FRMR frame is received. (Link is not 
    re-setup) 
    						
    							CHAPTER 3 NDA-24307
    Page 194
    Issue 1
    SYSTEM MESSAGES
    This message displays when the faults pertaining to CCIS/ISDN Link are restored to normal.
    ➀ Location of faulty CCH/DCH card
    ➁ Data to be Analyzed by NEC Engineers
    1: XXXX 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀ ➁
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b7 b6 b5 b4 b3 b2 b1 b0
    b7 b6 b5 b4 b3 b2 b1 b0
    Default Alarm:
    NON13-JRestoration From CCS Link FailureDefault Grade:
    3Grade Modified: Lamp Modified:
    b0-b4: Group No.
    b5, b6: Unit No. (0-3)
    b7: 0/1 = Even-numbered MG/Odd-numbered MG 
    						
    							NDA-24307 CHAPTER 3
    Page 195
    Issue 1
    SYSTEM MESSAGES
    This message displays when a fault occurred to the Port Microprocessor (PM) within the CCH/DCH circuit
    card and the restart processing is executed
    .
    ➀ Location of faulty CCH/DCH card
    1: XX00 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀ 
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b7 b6 b5 b4 b3 b2 b1 b0
    Default Alarm:
    SUP13-KCCH Reset Interrupt FailureDefault Grade:
    3Grade Modified: Lamp Modified:
    b0-b4: Group No. 
    b5, b6: Unit No. (0-3)
    b7: 0/1 = Even-numbered MG/Odd-numbered MG 
    						
    							CHAPTER 3 NDA-24307
    Page 196
    Issue 1
    SYSTEM MESSAGES
    This message displays when a digital line failure occurs on the DAI circuit card.
    ➀ DAI Card Mounting Location
    ➁ Kind of Fault
    1: XXXX 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀ ➁
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b7 b6 b5 b4 b3 b2 b1 b0
    b4 b3 b2 b1 b0
    Default Alarm:
    SUP13-NDigital Line WarningDefault Grade:
    1Grade Modified: Lamp Modified:
    b0-b4: Group No.
    b5, b6: Unit No. (0-3)
    b7: MG No.
    0/1 = Even-numbered MG/Odd-numbered MG
    b0-b4: Kind of Fault (HEX)
    00 = -
    01 = Frame alignment loss PCM down
    02 = Bit error rate is over 10
    -6
    03 = Slip is detected 
    04 = -
    05 = Dch down
    06 = Multi-frame alignment loss
    07 = -
    10 = -
    11 = Frame alignment loss PCM down (frequently)
    12 = Bit error rate is over 10
    -4
    13 = Slip is detected (frequently)
    14 = Opposite office alarm is detected
    15 = -
    16 = Multi-frame alignment loss (frequently)
    17 = Frame alignment loss PCM down (continuously)
    18 = Multi-frame alignment loss (continuously) 
    						
    							NDA-24307 CHAPTER 3
    Page 197
    Issue 1
    SYSTEM MESSAGES
    This message displays when a digital line failure occurs in succession on the DAI circuit card.
    ➀ DAI Card Mounting Location
    ➁ Kind of Fault
    1: XXXX 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀ ➁
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b7 b6 b5 b4 b3 b2 b1 b0
    b4 b3 b2 b1 b0
    Default Alarm:
    SUP13-ODigital Line FailureDefault Grade:
    2Grade Modified: Lamp Modified:
    b0-b4: Group No. 
    b5, b6: Unit No. (0-3)
    b7: MG No.
    0/1 = Even-numbered MG/Odd-numbered MG
    b0-b4: Kind of Fault (HEX)
    00 = -
    01 = Frame alignment loss PCM down
    02 = Bit error rate is over 10
    -4
    03 = Slip is detected 
    04 = Opposite office alarm (AIS) is detected
    05 = -
    06 = Multi-frame alignment loss
    07 = Frame alignment loss PCM down (continuously)
    08 = Multi-frame alignment loss (continuously) 
    						
    							CHAPTER 3 NDA-24307
    Page 198
    Issue 1
    SYSTEM MESSAGES
    This message displays when a digital line failure is restored to normal.
    ➀ DAI Card Mounting Location
    ➁ Kind of Fault
    1: XXXX 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀ ➁
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b7 b6 b5 b4 b3 b2 b1 b0
    b4 b3 b2 b1 b0
    Default Alarm:
    NON13-PDigital Line RestoreDefault Grade:
    0Grade Modified: Lamp Modified:
    b0-b4: Group No. 
    b5, b6: Unit No. (0-3)
    b7: MG No.
    0/1 = Even-numbered MG/Odd-numbered MG
    b0-b4: Kind of Fault (HEX)
    00 = -
    01 = Frame alignment loss PCM down
    02 = Bit error rate is over 10
    -4
    03 = -
    04 = Opposite office alarm (AIS) is detected
    05 = Dch restores to normal
    06 = Multi-frame alignment loss 
    						
    							NDA-24307 CHAPTER 3
    Page 199
    Issue 1
    SYSTEM MESSAGES
    This message displays when the battery is operated in the due to the Digital Access Unit (DAU) power down.
    ➀ DAI Card Mounting Location
    1: XX00 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀ 
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b7 b6 b5 b4 b3 b2 b1 b0
    Default Alarm:
    SUP13-QDAU Battery OperationDefault Grade:
    1Grade Modified: Lamp Modified:
    b0-b4: Group No.
    b5, b6: Unit No. (0-3)
    b7: MG No.
    0/1 = Even-numbered MG/Odd-numbered MG 
    						
    							CHAPTER 3 NDA-24307
    Page 200
    Issue 1
    SYSTEM MESSAGES
    This message displays when the main power of the Digital Access Unit (DAU) system is restored to normal,
    ending the temporary power acceptance from the battery observed in the message [13-Q] DAU
    Battery Operation.”
    ➀ DAI Card Mounting Location
    1: XX00 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀ 
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b7 b6 b5 b4 b3 b2 b1 b0
    Default Alarm:
    NON13-RDAU Line OperationDefault Grade:
    0Grade Modified: Lamp Modified:
    b0-b4: Group No. 
    b5, b6: Unit No. (0-3)
    b7: 0/1 = Even-numbered MG/Odd-numbered MG 
    						
    							NDA-24307 CHAPTER 3
    Page 201
    Issue 1
    SYSTEM MESSAGES
    This message displays when a PWR circuit card failure is detected.
    ➀ Power Circuit Card Location
    ➁ Fault Information
    ➂ Power Card Classification
    See Chapter 4 for the Circuit Card Replacement Procedure.
    1: XXXX XX00 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀ ➁ ➂
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b2 b1 b0
    b4 b3 b2 b1
    b0
    Default Alarm:
    NON13-ZPower FailureDefault Grade:
    3Grade Modified: Lamp Modified:
    b0, b1: Unit No. (0-3)
    b2: MG No.
    0/1 = Even-numbered MG/Odd-numbered MG
    b1: 0/1 = -/-5V Power Failure
    b2: 0/1 = -/+12V Power Failure
    b3: 0/1 = -/+5V Power Failure
    b4: 0/1 = -/-48V Power Failure
    b0: 0/1 = Group 24 (0 side) / Group 25 (1 side) 
    						
    							CHAPTER 3 NDA-24307
    Page 202
    Issue 1
    SYSTEM MESSAGES
    This message displays when a VPS failure is detected.
    ➀ Probable cause for the failure
    ➁ LENS of VPS
    ➂ LENS of VPS
    See Chapter 4 for the Circuit Card Replacement Procedure.
    1: XXXX XX00 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀ ➁ ➂
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b7 b6 b5 b4 b3 b2 b1 b0
    b7 b6 b5 b4 b3 b2 b1 b0
    b7 b6 b5 b4 b3 b2 b1 b0
    Default Alarm:
    SUP15-AVPS Failure (Temporary)Default Grade:
    1Grade Modified: Lamp Modified:
    b0-b7: 0 = -
    1 = Sector error
    FF = Other than above
    b0-b2: Level
    b3-b7: Group
    b0, b1: Unit
    b2-b7: Module Group 
    						