    							NDA-24307 CHAPTER 8
    Page 593
    Issue 1
    CHAPTER 8 MAINTENANCE COMMANDS
    This chapter explains various commands used in the system administrative management procedure. Table 8-1
    shows a list of maintenance commands.
    Table 8-1  Command Lis t  
    COMMAND COMMAND FULL NAME
    ALLC Assignment of Line Load Control
    ALMG Assignment of Alarm Grade Data
    ATRF Assignment of Traffic Measurement Order
    ATRFN Assignment of Traffic Measurement Order for Fusion Network
    BOSD Back Up One-Touch Speed Call Memory Data
    CADSD Continuous Assignment of Station Data
    CATK Continuous Assignment of Trunk Data
    CBCN Control of Broadcasting for NDM
    CCSE Change of Common Signaling Channel Equipment
    CDBU Change of Dch Backup
    CMOD Change of System Mode
    CMODI Change of System Mode for ISW
    CMWL Control Message Waiting Lamp
    CMWL_T Control Message Waiting Lamps - Telephone Number
    CPRS Controlled Alternate PRSCs
    CSCL Continuous Change of Station Class
    CSTN Continuous Change of Station Number
    DCBD Display of Call Block Entry Data
    DCEN Display of Connection Trunk LENS Data for LDM
    DCON Display of Connection Status
    DFTD Display of System Message Details
    DISS Display of Program Issue
    DLEN Display of LENS Data
    DLSL Display of Lock Out Station - LENS
    DLSS Display of Lockout Station - Number
    DLSS_T Display of Lock Out Station - Number- Telephone Number 
    						
    							CHAPTER 8 NDA-24307
    Page 594
    Issue 1
    MAINTENANCE COMMANDS
    DLTEL Display of Telephone Number from LENS for LDM
    DNTEL Display of Telephone Number from LENS for NDM
    DPKG Display of Setting Port Package
    DPSW Display Package Switch Status
    DSTN Display of Station Data
    DTELN Display of Telephone Number Data for NDM
    DTF101 Display of Terminal Traffic Data
    DTF102 Display of Route Traffic Data
    DTF103 Display of Station Peg Count Data
    DTF104 Display of Attendant Peg Count Data
    DTF105 Display of Route Peg Count Data
    DTF201 Display of Service Peg Count Data
    DTF301 Display of UCD Route Peg Count Data
    DTF302 Display of UCD Group Peg Count Data
    DTF303 Display of Station Peg Count Data
    DTF501 Display of Attendant Answering Peg Count Data
    DTF601 Display of Connection Route Peg Count Data
    DTF602 Display of Connection Route Traffic Data
    DTF101N Display of Terminal Traffic Data for Fusion Network
    DTF102N Display of Route Traffic Data for Fusion Network
    DTF103N Display of Station Peg Count Data for Fusion Network
    DTF104N Display of Attendant Peg Count Data for Fusion Network
    DTF105N Display of Route Peg Count Data for Fusion Network
    DTF201N Display of Service Peg Count Data for Fusion Network
    DTF301N Display of UCD Route Peg Count Data for Fusion Network
    DTF302N Display of UCD Group Peg Count Data for Fusion Network
    DTF303N Display of Station Peg Count Data for Fusion Network
    DTF501N Display of Attendant Answering Peg Count Data for Fusion Network
    DTF601N Display of Connection Route Peg Count Data for Fusion Network
    DTF602N Display of Connection Route Traffic Data for Fusion NetworkTable 8-1  Command List (Continued) 
    COMMAND COMMAND FULL NAME 
    						
    							NDA-24307 CHAPTER 8
    Page 595
    Issue 1
    MAINTENANCE COMMANDS
    FLINST File Install
    HDD_FDD Data Control Between HDD and FDD
    HDD_MAT Data Control Between HDD and MAT
    HDD_MAT_N Data Control Between HDD and MAT for NDM
    HDFP HDD Format of PBX
    MBCT Make Busy of Connection Trunk for LDM
    MBLE Make Busy of LENS
    MBPM Make Busy of Port Microprocessor
    MBRT Make Busy of Route
    MBSM Make Busy of System Message Printout
    MBST Make Busy of Station
    MBST_T Make Busy of Station - Telephone Number
    MBTC Make Busy of Trunk-Continuous
    MBTK Make Busy of Trunk
    MEM_HDD Data Control Between Memory and HDD
    MEM_HDD_N Data Control Between Memory and HDD for NDM
    MFCH Make Busy of FCCH
    PMBU Port Microprocessor Back Up
    RALM Release Alarm
    RALMN Release Alarm for NDM
    RLST Release Station/Trunk
    RLST_T Release Station/Trunk - Telephone Number
    SINZ System Initialization
    SINZI System Initialization for ISW
    SPTS Scanning of Port Status
    SRTS Scanning of Route Status
    XHFD X-RAY HD or FDD DiagnosisTable 8-1  Command List (Continued) 
    COMMAND COMMAND FULL NAME 
    						
    							CHAPTER 8 NDA-24307
    Page 596
    Issue 1
    ALLC: Assignment of Line Load Control
    ALLC:Assignment of Line Load Control
    1. Functional Outline
    This command designates the start and stop of line load control.
    2. Parameters
    Input Data
    ALL/ONE: Operation Mode Selection (1,2)
    O/A=Only One LP/All LPs
    LP: Local Partition (LP) Number 
    Note
    STATUS: Line Load Control Status (0-3)
    0=Stop Line Load Control
    1=Start Line Load Control
    2=Automatic Line Load Control is in effect (display only)
    3=Status of all LPs do not match (display only)
    Note:This parameter appears when 0 (only one LP) is set in ALL/ONE input data. 
    						
    							NDA-24307 CHAPTER 8
    Page 597
    Issue 1
    ALMG: Assignment of Alarm Grade Data
    ALMG:Assignment of Alarm Grade Data
    1. Functional Outline
    This command makes a flexible change of system message output grades. Thus, the PBX user can give a proper
    alarm grade to each system message according to their requirements. When no data is assigned, the default
    alarm grades are automatically adopted.
    Note:This command cannot change the alarm grade for [6-A] system message.
    2. Parameters
    Input data
    FK: Fault Message Kind (0-7, 10-17, 20-27, 30-37)
    FI: Fault Message Index (A-Z)
    LMP: Fault Message Lamp Data (0-3)
    0=Lamp OFF
    1=SUP Lamp ON
    2=MN Lamp ON
    3=MJ Lamp ON
    GRD: Printout Grade (0-3)
    TYPE: List-up Type)
    1=All Data
    2=Changed Data
    3=Default Data
    SYSM GRD: System Message Output Grade
    0=All Messages
    1=Not Used
    2=MN/MJ Grade Massages
    3=MJ Grade Massages 
    						
    							CHAPTER 8 NDA-24307
    Page 598
    Issue 1
    ATRF: Assignment of Traffic Measurement Order
    AT R F :Assignment of Traffic Measurement Order
    1. Functional Outline
    This command is used to assign and delete node-level traffic measurement programs. A request for traffic
    measurement is performed on each node basis when a traffic measurement instruction has been assigned by
    this command. The collected traffic measurement data can be stored on the HD of the MAT, which can be
    designated on the basis of traffic measurement type.
    2. Parameters
    Input Data
    TYPE: Type of Traffic Measurement (1-19)
    PORT: Traffic Information Output Terminal Number (0-7: IOC, 8: LAN, 9: NMS) 
    INTERVAL: Output interval (0, 30-120)
    Assign the data (30-120) in 10 minute increments. When assigning 0 (available when any
    of TYPE 3-18 is selected), instead specify your desired output time in the OUTPUT
    HOUR/MINUTE parameters below.
    START HOUR
    Note 
    START MINUTE
    Note 
    END HOUR
    Note 
    END MINUTE
    Note 
    OUTPUT HOUR: This data is valid only when “INTERVAL”=0.
    OUTPUT MINUTE: This data is valid only when “INTERVAL”=0.
    START RT: Start External Route Number (available when TYPE 2/5/8 is selected)
    END RT: End External Route Number (available when TYPE 2/5/8 is selected)
    DATA MEANING DATA MEANING
    1 Terminal Traffic 2 Route Traffic
    3 Station Peg Count 4 ATT Peg Count
    5 Route Peg Count 6 Service Peg Count
    8 UCD Route Peg Count 9 UCD Group Peg Count
    10 UCD Station Peg Count 15 ATT Answering Peg Count
    18 Connection Route Peg Count 19 Connection Route Traffic 
    						
    							NDA-24307 CHAPTER 8
    Page 599
    Issue 1
    ATRF: Assignment of Traffic Measurement Order
    START C_RT: Start Connection Route Number (available when TYPE 18/19 is selected)
    END C_RT: End Connection Route Number (available when TYPE 18/19 is selected)
    Note:Assign the traffic measurement time period between START HOUR/MINUTE and END HOUR/
    MINUTE longer than an hour. Also, if the measurement should be executed throughout a day, assign
    the same data in both START HOUR/MINUTE and END HOUR/MINUTE parameter 
    						
    							CHAPTER 8 NDA-24307
    Page 600
    Issue 1
    ATRFN: Assignment of Traffic Measurement Order for Fusion Network
    ATRFN:Assignment of Traffic Measurement Order for Fusion Network
    1. Functional Outline
    This command is used to assign and delete traffic measurement programs available on the Ethernet. A request
    for traffic measurement is performed on a network basis when a traffic measurement instruction has been
    assigned by this command. The collected traffic measurement data can be stored on the HD of the MAT
    (connected to the NCN: Network Control Node), which can be designated on the basis of traffic measurement
    type. Note that this command can be used at the NCN only.
    2. Parameters
    Input Data
    TYPE: Type of Traffic Measurement (1-19) 
    Note 1
    PORT: Traffic Information Output Terminal Number (0-7: IOC, 8: LAN, 9: NMS) 
    INTERVAL: Output interval (0, 30-120)
    Assign the data (30-120) in 10 minute increments. When assigning 0 (avail-
    able when any of TYPE 3-18 is selected), instead specify your desired output
    time in the “OUTPUT HOUR/MINUTE” parameters below.
    START HOUR
    Note 2, Note 3
    START MINUTENote 2, Note 3
    END HOURNote 2, Note 3
    END MINUTENote 2, Note 3
    OUTPUT HOUR: This data is valid only when “INTERVAL”=0.
    OUTPUT MINUTE: This data is valid only when “INTERVAL”=0.
    START LGRT: Start Logical Route Number (available when TYPE 2/5/8 is selected)
    DATA MEANING DATA MEANING
    1 Terminal Traffic 2 Route Traffic
    3 Station Peg Count 4 ATT Peg Count
    5 Route Peg Count 6 Service Peg Count
    8 UCD Route Peg Count 9 UCD Group Peg Count
    10 UCD Station Peg Count 15 ATT Answering Peg Count
    18 Connection Route Peg Count 19 Connection Route Traffic 
    						
    							NDA-24307 CHAPTER 8
    Page 601
    Issue 1
    ATRFN: Assignment of Traffic Measurement Order for Fusion Network
    END LGRT: End Logical Route Number (available when TYPE 2/5/8 is selected)
    START C_RT: Start Connection Route Number (available when TYPE 18/19 is selected)
    END C_RT: End Connection Route Number (available when TYPE 18/19 is selected)
    Note 1:The selected traffic measurement data, except for TYPE 1 (Terminal Traffic), is collected with the
    whole network systems as a single unit.
    Note 2:When time difference exists between the nodes, confirm that the related time difference data, based on
    the UCT (Universal Coordinated Time) standard, has been assigned at each node via the ATDF com-
    mand.
    Note 3:Assign the traffic measurement time period between START HOUR/MINUTE and END HOUR/
    MINUTE longer than an hour. Also, if the measurement should be executed throughout a day, assign
    the same data in both START HOUR/MINUTE and END HOUR/MINUTE parameters.
    Note 4:If the data for this command is once assigned, the node-level data by the ATRF command is not
    cleared, but loses its validity (the network-level data takes precedence). 
    						
    							CHAPTER 8 NDA-24307
    Page 602
    Issue 1
    BOSD: Back Up One-Touch Speed Call Memory Data
    BOSD:Back Up One-Touch Speed Call Memory Data
    1. Functional Outline
    Save Function
    Saves the data residing in the One-Touch Speed Call Memory of ELC card onto a floppy disk.
    Verify Function
    Verifies the One-Touch Speed Call Memory data saved on the floppy disk with the data residing in the
    One-Touch Speed Call Memory of ELC card.
    Load Function
    Loads the One-Touch Speed Call Memory data saved in the floppy disk into the One-Touch Speed Call
    Memory of ELC card.
    2. Parameters
    Input data
    Direction Select: PBX Memory to MAT/MAT to PBX Memory / Verify MAT against MEM
    Data Type Selection: by Station / by LEN
    Begin TN:
    Note 1
    End TN:Note 1
    Begin STN:Note 1
    End STN:Note 1
    Begin LEN:Note 2
    End LEN:Note 2
    Auto Verify Afterward: Click ON/OFF=Checked/Unchecked
    File Name and Path
    Note 1:When “by Station” is designated
    Note 2:When “by LEN” is designated 
    						