    							NDA-24307 CHAPTER 3
    Page 143
    Issue 1
    SYSTEM MESSAGES
    This message displays when the MBR switch on the TSW card has been turned OFF at CPU changeover or
    speech path changeover.
    ➀ System Status of TSW Card
    1: XX00 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀ 
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b7 b0
    Default Alarm:
    NON7-FTSW MBR Key Turn OFFDefault Grade:
    3Grade Modified: Lamp Modified:
    b0: 0/1 = No. 0 system/No. 1 system
    b7: Kind of PKG
    0/1 = SW12/GT09 
    						
    							CHAPTER 3 NDA-24307
    Page 144
    Issue 1
    SYSTEM MESSAGES
    This message displays when the MB switch on the EMA card has been turned ON when extracting or inserting
    a circuit card or at PM initialization. This message displays with the [7-J]: ALMC MB Key Turn OFF message.
    ➀ Frame No. and its Kind
    1: XX00 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀ 
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b7 b6 b5 b4 b3 b2 b1 b0
    Default Alarm:
    SUP7-IALMC MB Key Turn ONDefault Grade:
    3Grade Modified: Lamp Modified:
    b0-b3: Frame No. (0 only)
    b4-b5: Frame Group No. (0 only)
    b6-b7: Kind of Frame
    00=IMG 
    						
    							NDA-24307 CHAPTER 3
    Page 145
    Issue 1
    SYSTEM MESSAGES
    This message displays when the MB switch on the EMA card has been turned OFF when extracting or inserting
    a circuit card or at PM initialization.
    ➀ Frame No. and its Kind
    1: XX00 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀ 
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b7 b6 b5 b4 b3 b2 b1 b0
    Default Alarm:
    NON7-JALMC MB Key Turn OFFDefault Grade:
    3Grade Modified: Lamp Modified:
    b0-b3: Frame No. (0 only)
    b4-b5: Frame Group No. (0 only)
    b6-b7: Kind of Frame
    00=IMG 
    						
    							CHAPTER 3 NDA-24307
    Page 146
    Issue 1
    SYSTEM MESSAGES
    This message displays when the MB switch on the line/trunk card has been turned ON when extracting or
    inserting a circuit card or at PM initialization.
    ➀ Faulty Line/Trunk Card Location 
    1: XX00 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀ 
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b7 b6 b5 b4 b3 b2 b1 b0
    Default Alarm:
    NON7-KPM MB Key Turn ONDefault Grade:
    3Grade Modified: Lamp Modified:
    b0-b4: Group No. 
    b5, b6: Unit No. (0-3)
    b7: MG No.
    0/1 = Even-numbered MG/Odd-numbered MG 
    						
    							NDA-24307 CHAPTER 3
    Page 147
    Issue 1
    SYSTEM MESSAGES
    This message displays when the MB switch on the line/trunk card has been turned OFF when extracting or
    inserting a circuit card or at PM initialization.
    ➀ Faulty Line/Trunk Card Location 
    1: XX00 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀ 
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b7 b6 b5 b4 b3 b2 b1 b0
    Default Alarm:
    NON7-LPM MB Key Turn OFFDefault Grade:
    3Grade Modified: Lamp Modified:
    b0-b4: Group No.
    b5, b6: Unit No. (0-3)
    b7: MG No.
    0/1 = Even-numbered MG/Odd-numbered MG 
    						
    							CHAPTER 3 NDA-24307
    Page 148
    Issue 1
    SYSTEM MESSAGES
    This message displays when the MB switch on the PFT card has been turned ON when extracting or inserting
    a circuit card or at PM initialization.
    ➀ Faulty PFT Card No.
    ➁ Faulty PFT Card Location
    1: XXXX 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀ 
    ➁
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b2 b1 b0
    b7 b6 b5 b4 b3 b2 b1 b0
    Default Alarm:
    NON7-MNCU MB Key Turn ONDefault Grade:
    3Grade Modified: Lamp Modified:
    b0-b2: Circuit card No. (0-7)
    b0-b4: Group No.
    b5, b6: Unit No. (0-3)
    b7: 0/1 = Even-numbered MG/Odd-numbered MG 
    						
    							NDA-24307 CHAPTER 3
    Page 149
    Issue 1
    SYSTEM MESSAGES
    This message displays when the MB switch on the PFT card has been turned OFF when extracting or inserting
    a circuit card, or at PM initialization.
    ➀ Faulty PFT Card No.
    ➁ Faulty PFT Card Location
    1: XXXX 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀ 
    ➁
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b2 b1 b0
    b7 b6 b5 b4 b3 b2 b1 b0
    Default Alarm:
    NON7-NNCU MB Key Turn OFFDefault Grade:
    3Grade Modified: Lamp Modified:
    b0-b2: Circuit card No. (0-7)
    b0-b4: Group No.
    b5, b6: Unit No. (0-3)
    b7: 0/1 = Even-numbered MG/Odd-numbered MG 
    						
    							CHAPTER 3 NDA-24307
    Page 150
    Issue 1
    SYSTEM MESSAGES
    In a specific time cycle, the system allows a routine diagnosis in its hardware and software to determine if they
    are operating properly. This message indicates that the system has been checked by the routine diagnosis
    program and the result of the diagnosis is normal.
    ➀ Performed Diagnosis Item
    Note:The data in this area will be diverse, according to the diagnosis specified in ➀. For details on each
    item data, see the following pages.
    1: XXXX XXXX XXXX XXXX 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    Note
    ➀ 
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b7 b6 b5 b4 b3 b2 b1 b0
    Default Alarm:
    NON7-OCyclic Diagnosis NormalDefault Grade:
    3Grade Modified: Lamp Modified:
    [00H] Routine Diagnosis Start
    [10H] Program Memory Verification Normal End
    [20H] Data Memory Verification Normal End
    [30H] TSW ACT/STBY Changeover Normal End
    [40H] CPU ACT/STBY Changeover Normal End
    [50H] No Trunk Ineffective Hold
    [70H] Call Forwarding Memory Clear Normal End
    [A0H] Periodic Back-up Normal End
    [C0H] Detection of Remaining Link Normal End 
    						
    							NDA-24307 CHAPTER 3
    Page 151
    Issue 1
    SYSTEM MESSAGES
    [00H] Routine Diagnosis Start
    ➀ Performed Diagnosis Item
    ➁ Diagnosis Menu (SYS1, Index 89)
    ➂ Diagnosis Menu (SYS1, Index 90)
    ➃ Call Forward Memory Clear Item 
    (SYS1, Index 232)
    ➄ Periodic Back-up Item 
    (SYS1, Index 304)
    1: 00XX 0X0X XX00 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀  ➁ ➂  ➃ ➄
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b7 b6 b5 b4 b3 b2 b1 b0
    b3 b1
    b2 b1 b0
    b5 b4 b3 b2 b1 b0
    [00H] Routine Diagnosis Start (LN)
    [01H] Routine Diagnosis Start (ISW)
    b0: 0/1=-/Program Memory Verification
    b1: 0/1=-/Data Memory Verification
    b2: 0/1=-/TSW ACT/STBY Changeover
    b3: 0/1=-/CPU ACT/STBY Changeover
    b4: 0/1=-/Trunk Ineffective Hold Check
    b5: 0/1=-/Trunk Ineffective Hold Detection
    b6: 0/1=-/Call Forwarding Memory Clear
    b7: 0/1=-/IP ACT/STBY Changeover
    b1: 0/1 = -/Periodic Back-up
    b3: 0/1 = -/Residual Link Detection
    b0: 0/1 = -/Call Forward All Clear
    b1: 0/1 = -/Call Forward Busy Clear
    b2: 0/1 = -/Call Forward No Answer Clear
    b0: 0/1 = -/Individual Speed Calling Data Save
    b1: 0/1 = -/Call Forwarding Data Save
    b2: 0/1 = -/PCS Data Save
    b3: 0/1 = -/Name Display Data Save
    b4: 0/1 = -/User Assign Soft Key Data Save
    b5: 0/1 = -/Number Sharing Data Save 
    						
    							CHAPTER 3 NDA-24307
    Page 152
    Issue 1
    SYSTEM MESSAGES
    [10H] Program Memory Verification Normal End
    ➀ Performed Diagnosis Item
    ➁ Information on HD
    ➂ Verification of Drive Number
    1: 10XX XX00 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀ ➁ ➂
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b1 b0
    b3 b2 b1 b0
    [10H] Program Memory Verification Normal End
    b0: 0/1 = -/HFD 0 is normal
    b1: 0/1 = -/HFD 1 is normal
    b0: 0/1 = -/Drive Number 0
    b1: 0/1 = -/Drive Number 1
    b2: 0/1 = -/Drive Number 2
    b3: 0/1 = -/Drive Number 3 
    						