    							NDA-24307 CHAPTER 3
    Page 123
    Issue 1
    SYSTEM MESSAGES
    Note 4:
    When“➁ (ACD Trouble Kind)” is 24 or 99 Hex:
    ➂ ~ ➅ Not used
    ➆, ➇Error Counter
    Note 5:When“➁ (ACD Trouble Kind)” is 30 Hex:
    ➂ ~ ➅ Pointer Address
    ➆Not used
    ➇Error Kind
    Note 6:When“➁ (ACD Trouble Kind)” is 33 Hex:
    ➂ ACDP Data Memory
    00 = Used
    01 = Not used
    ➃ACDP System Capacity
    02 = 50 Agent Positions
    04 = 200 Agent Positions
    07 = 500 Agent Positions
    12 = 900 Agent Positions
    15 = 2,000 Agent Positions
    Note:If other data is output, the ACD system may not be working correctly. In this case, be sure to install the
    ACD application again by using the MSVIP command.
    Note 7:When“➁ (ACD Trouble Kind)” is 34 Hex:
    ➂ ~ ➅ Information on Unknown Pilot No.
    Refer to 
    ➂ ~ ➅, (a) Station of Note 1
    Note 
    						
    							CHAPTER 3 NDA-24307
    Page 124
    Issue 1
    SYSTEM MESSAGES
    This message displays to indicate the result of a designated connection test (Individual Trunk Access) from a
    station.
    ➀Test Item (b0-b3 is valid only for 
    Outgoing trunk test)
    1: XXXX XXXX XXXX XXXX 2: XXXX 00XX XXXX XXXX 3: XXXX XXXX XXXX XX00
    ➀ ➁ ➂ ➃ ➄ ➅
    ➆  ➇➈ ➉11 12 12 12 12 12
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b7 b6 b5 b4 b3 b2 b1 b0
    Default Alarm:
    NON6-ISTA-Test Connection DataDefault Grade:
    3Grade Modified: Lamp Modified:
    b0-b2: Kind of Signal
    2 = Second Dial Tone
    6 = Sender (Delay Dial Start)
    7 = Sender (Wink Start)
    b3: 0/1 = Data is not valid/valid
    b4-b7: Test item
    1 = Outgoing Trunk Test
    2 = ORT/IRT Test
    3 = Sender Test
    4 = Digital Conference
    5 = Tone Test
    6 = Ringing Signal test
    0 = Test NG
    12 
    						
    							NDA-24307 CHAPTER 3
    Page 125
    Issue 1
    SYSTEM MESSAGES
    ➁ 
    ➂ ~ ➄ Station number of testing 
    station (see table)
    ➅ Te n a n t  N o . b7 b6 b5 b4 b3 b2 b1 b0
    b7 b3 b2 b1 b0
    b0-b3: Number of digits of testing station No.
    b4-b7: Error Numbers (see table below)
    Error Numbers and Their Meanings
    ERROR NO. MEANING
    0---
    1 Testing station is restricted from activating the 
    service.
    2 Route Number Error of the designated trunk
    3 Trunk Number Error of the designated trunk
    4 Trunk busy
    5 Sender busy
    6 SMDR failure
    7 Call origination restriction
    8Register busy
    9 Trunk Number Error - when the trunk has been 
    designated by SHF.
    A Trunk busy - when the trunk has been designated 
    by SHF.
    B Inter-digit timer expiration
    C Register or sender is defective with respect to DP, 
    DP/PB
    D Register of sender is faulty with respect to PB
    ETone fault
    F Test Processing Error
    b4-b7 b0-b3
    ➂DC0 DC1
    ➃DC2 DC3
    ➄DC4 DC5
    b0-b3: Tenant No. (1-15)
    b7: OP
    0/1 = Data in OPTN ( 
    ➆ ) is invalid/valid 
    						
    							CHAPTER 3 NDA-24307
    Page 126
    Issue 1
    SYSTEM MESSAGES
    ➆ Tenant No.
    ➇ Tested Route No.
    Note:When Logical Routes are assigned, Logical Route Numbers are displayed here.
    ➈ OPRT data
    Note:When Logical Routes are assigned, Logical Route Numbers are displayed here.
    ➉ (This data is not for Ringing Signal Test)
     Digit of Dialed Number (for test)
     Dialed Number (for test)
    (a) Dialed Number sent by the test Trunk/Senderb3 b2 b1 b0
    b7 b6 b5 b4 b3 b2 b1 b0
    b7 b6 b5 b4 b3 b2 b1 b0
    b7 b4 b3 b2 b1 b0
    b7 b6 b5 b4 b3 b2 b1 b0
    b4-b7b0-b3b4-b7b0-b3
    DC0 DC1 DC12 DC13
    DC2 DC3 DC14 DC15
    DC4 DC5 DC16 DC17
    DC6 DC7 DC18 DC19
    DC8 DC9 DC20 DC21
    DC10 DC11
    b0-b3: Tenant No. (Over 15)
    b0-b5: Route No. (1-63) Note
    b6: OP
    0/1 = Data in OPRT ( 
    ➈ ) is invalid/valid
    b7: AC
    0/1 = Internal trunk/External trunk
    b0-b7: Route No. ( 64)Note >
    b0-b7: Trunk No. for Outgoing trunk test, ORT/IRT Test, Sender
    Test and Digital Conference test
    Tone Slot No. for Tone Test
    0 = DT 1 = SPDT
    2 = RBT 3 = CRBT, CWT
    4 = BT 5 = RBT
    6 = SST, WT 7 = SDT
    8 = TRG 9 = SDTT
    10 = CWRBT 14 = MSC b7 b6 b5 b4 b3 b2 b1 b0
    b0-b4: Dialed number digit sent by the test Trunk/Sender
        or
    Dialed number digit received by the test Register11
    12
    b) Dialed Number received by the test Register
    b4-b7b0-b3
    DC0 DC1
    DC2 DC3
    DC4 DC5
    DC6 DC7
    DC8 DC9
    DC10 DC11 
    						
    							NDA-24307 CHAPTER 3
    Page 127
    Issue 1
    SYSTEM MESSAGES
    This message displays when a call terminates to the Emergency Telephone.
    ➀ ~ ➅ Called Station (Emergency 
    Telephone) No. (ASCII Code)
    ➆ ~   Calling Station No. (ASCII 
    Code)
    1: XXXX XXXX XXXX XXXX 2: XXXX XXXX 0000 0000 3: 0000 0000 0000 0000
    ➀ ➁ ➂ ➃ ➄ ➅
    ➆  ➇➈ ➉
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b7 b6 b5 b4 b3 b2 b1 b0
    b7 b6 b5 b4 b3 b2 b1 b0
    Default Alarm:
    SUP6-JEmergency CallDefault Grade:
    3Grade Modified: Lamp Modified:
    ➀DC0 (1st digit)
    ➁DC1 (2nd digit)
    ➂DC2 (3rd digit)
    ➃DC3 (4th digit)
    ➄DC4 (5th digit)
    ➅DC5 (6th digit)
    ➆DC0 (1st digit)
    ➇DC1 (2nd digit)
    ➈DC2 (3rd digit)
    ➉DC3 (4th digit)
    DC4 (5th digit)
    DC5 (6th digit)
    11
    12
    12
    1211 
    						
    							CHAPTER 3 NDA-24307
    Page 128
    Issue 1
    SYSTEM MESSAGES
    This message displays when the LCR-Attendant Manual Override is set at the Attendant/Desk Console.
    ➀ Route Selection Time Pattern No. 
    assigned at Attendant/Desk 
    Console
    Note:Route Selection Time Pattern 0-7 corresponds to TDPTN No. 0-7 in the AOPR command.
    1: XX00 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀
     
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b2 b1 b0
    Default Alarm:
    NON6-LEmergency Control StartDefault Grade:
    3Grade Modified: Lamp Modified:
    b0-b2: Pattern No. (1-7) 
    						
    							NDA-24307 CHAPTER 3
    Page 129
    Issue 1
    SYSTEM MESSAGES
    This message displays when the LCR-Attendant Manual Override is cancelled at the Attendant/Desk Console.
    ➀ Suspension of Emergency Control
    Note:Route Selection Patterns 0-7 corresponds to TDPTN No. 0-7 in the AOPR command.
    1: XX00 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀
     
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b0
    Default Alarm:
    NON6-MEmergency Control StopDefault Grade:
    3Grade Modified: Lamp Modified:
    b0: Fixed 0.
    0 = Outgoing call restriction is released by Attendant/Desk Console 
    						
    							CHAPTER 3 NDA-24307
    Page 130
    Issue 1
    SYSTEM MESSAGES
    This message displays when the system detects abnormal duration in the line connection between the calling
    and called party. When the calling and called party establish a line connection and continue the hook-up for an
    extremely short or long period of time (predetermined by the ASYD command (SYS1, INDEX45, 46)), this
    message is created.
    ➀ Calling party information
    ➁ Tenant No. of Calling/Called party (Hex.)
    ➂ Calling party Information
    When calling party is Station
    Calling station No. (See table)
    1: XXXX XXXX XXXX XX00 2: XXXX XXXX XXXX XXXX 3: XXXX XXXX XXXX XX00
    ➀ ➁ ➁ ➂ ➂ ➂ ➂  ➃ ➄ ➄ ➄ ➄ ➄ ➄ ➄ ➄ ➄ ➄ ➄ ➄ ➄ ➄ 
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b7 b3 b2 b1 b0
    b7 b6 b5 b4 b3 b2 b1 b0
    Default Alarm:
    NON6-NAbnormal Call Duration DataDefault Grade:
    0Grade Modified: Lamp Modified:
    b0-b3: Type of Calling party
    0 = Station
    1 = Attendant console
    2 = Trunk
    b7: 0/1 = Short/Long Time
    b4-b7b0-b3
    DC0 DC1
    DC2 DC3
    DC4 DC5 
    						
    							NDA-24307 CHAPTER 3
    Page 131
    Issue 1
    SYSTEM MESSAGES
    When calling party is ATTCON/DESKCON
    Attendant/Desk console No. (See 
    table.)
    When calling party is Trunk
    Route No. and Trunk No. (See table.)
    Note:
    Route No. (a)
    Route No. (b)
    ➃ Called party information b7 b6 b5 b4 b3 b2 b1 b0
    b7 b6 b5 b4 b3 b2 b1 b0
    b3 b2 b1 b0
    b3 b2 b1 b0
    b4- b7b0-b3
    DC0 DC1
    b0-b7
    (a) Route No. (Hex) Note
    (b) Route No. (Hex) Note
    (c) Trunk No. (Hex) 
    (d) Trunk No. (Hex) 
    b0-b5: Route No. (1-63)
    b6: OP
    0/1 = Data in OPRT is invalid/valid
    b7: AC
    0/1 = Internal trunk/External trunk
    b0-b3: OPRT
    Route No. (Over 64)
    b0-b3:
    00 = Station-to-Station call
    01 = Outgoing call to outside
    02 = Incoming call from outside 
    						
    							CHAPTER 3 NDA-24307
    Page 132
    Issue 1
    SYSTEM MESSAGES
    ➄ Called Party Information
    Station to Station Call
    OG Call to outside IC Call from outside
    b4-b7 b0-b3
    (a)
    Te n a n t  N o .
    Te n a n t  N o .
    DC0 DC1
    DC2 DC3
    DC4 DC5(a) Type of called party
    00 = Station
    b7 b6 b5 b4 b3 b2 b1 b0
    b0-b7
    Route No. (Hex)
    Route No. (Hex)
    Trunk No. (Hex)
    Trunk No. (Hex)b4-b7 b0-b3
    Route No. (Hex)
    Route No. (Hex)
    Trunk No. (Hex)
    Trunk No. (Hex)
    DC0 DC1
    DC2 DC3
    DC4 DC5
    DC6 DC7
    DC8 DC9
    DC10 DC11
    DC12 DC13
    DC14 DC15
    DC16 DC17
    DC18 DC19 
    						