NDA-24307 CHAPTER 3 Page 123 Issue 1 SYSTEM MESSAGES Note 4: When“➁ (ACD Trouble Kind)” is 24 or 99 Hex: ➂ ~ ➅ Not used ➆, ➇Error Counter Note 5:When“➁ (ACD Trouble Kind)” is 30 Hex: ➂ ~ ➅ Pointer Address ➆Not used ➇Error Kind Note 6:When“➁ (ACD Trouble Kind)” is 33 Hex: ➂ ACDP Data Memory 00 = Used 01 = Not used ➃ACDP System Capacity 02 = 50 Agent Positions 04 = 200 Agent Positions 07 = 500 Agent Positions 12 = 900 Agent Positions 15 = 2,000 Agent Positions Note:If other data is output, the ACD system may not be working correctly. In this case, be sure to install the ACD application again by using the MSVIP command. Note 7:When“➁ (ACD Trouble Kind)” is 34 Hex: ➂ ~ ➅ Information on Unknown Pilot No. Refer to ➂ ~ ➅, (a) Station of Note 1 Note
![](/img/blank.gif)
CHAPTER 3 NDA-24307 Page 124 Issue 1 SYSTEM MESSAGES This message displays to indicate the result of a designated connection test (Individual Trunk Access) from a station. ➀Test Item (b0-b3 is valid only for Outgoing trunk test) 1: XXXX XXXX XXXX XXXX 2: XXXX 00XX XXXX XXXX 3: XXXX XXXX XXXX XX00 ➀ ➁ ➂ ➃ ➄ ➅ ➆ ➇➈ ➉11 12 12 12 12 12 4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000 b7 b6 b5 b4 b3 b2 b1 b0 Default Alarm: NON6-ISTA-Test Connection DataDefault Grade: 3Grade Modified: Lamp Modified: b0-b2: Kind of Signal 2 = Second Dial Tone 6 = Sender (Delay Dial Start) 7 = Sender (Wink Start) b3: 0/1 = Data is not valid/valid b4-b7: Test item 1 = Outgoing Trunk Test 2 = ORT/IRT Test 3 = Sender Test 4 = Digital Conference 5 = Tone Test 6 = Ringing Signal test 0 = Test NG 12
![](/img/blank.gif)
NDA-24307 CHAPTER 3 Page 125 Issue 1 SYSTEM MESSAGES ➁ ➂ ~ ➄ Station number of testing station (see table) ➅ Te n a n t N o . b7 b6 b5 b4 b3 b2 b1 b0 b7 b3 b2 b1 b0 b0-b3: Number of digits of testing station No. b4-b7: Error Numbers (see table below) Error Numbers and Their Meanings ERROR NO. MEANING 0--- 1 Testing station is restricted from activating the service. 2 Route Number Error of the designated trunk 3 Trunk Number Error of the designated trunk 4 Trunk busy 5 Sender busy 6 SMDR failure 7 Call origination restriction 8Register busy 9 Trunk Number Error - when the trunk has been designated by SHF. A Trunk busy - when the trunk has been designated by SHF. B Inter-digit timer expiration C Register or sender is defective with respect to DP, DP/PB D Register of sender is faulty with respect to PB ETone fault F Test Processing Error b4-b7 b0-b3 ➂DC0 DC1 ➃DC2 DC3 ➄DC4 DC5 b0-b3: Tenant No. (1-15) b7: OP 0/1 = Data in OPTN ( ➆ ) is invalid/valid
![](/img/blank.gif)
CHAPTER 3 NDA-24307 Page 126 Issue 1 SYSTEM MESSAGES ➆ Tenant No. ➇ Tested Route No. Note:When Logical Routes are assigned, Logical Route Numbers are displayed here. ➈ OPRT data Note:When Logical Routes are assigned, Logical Route Numbers are displayed here. ➉ (This data is not for Ringing Signal Test) Digit of Dialed Number (for test) Dialed Number (for test) (a) Dialed Number sent by the test Trunk/Senderb3 b2 b1 b0 b7 b6 b5 b4 b3 b2 b1 b0 b7 b6 b5 b4 b3 b2 b1 b0 b7 b4 b3 b2 b1 b0 b7 b6 b5 b4 b3 b2 b1 b0 b4-b7b0-b3b4-b7b0-b3 DC0 DC1 DC12 DC13 DC2 DC3 DC14 DC15 DC4 DC5 DC16 DC17 DC6 DC7 DC18 DC19 DC8 DC9 DC20 DC21 DC10 DC11 b0-b3: Tenant No. (Over 15) b0-b5: Route No. (1-63) Note b6: OP 0/1 = Data in OPRT ( ➈ ) is invalid/valid b7: AC 0/1 = Internal trunk/External trunk b0-b7: Route No. ( 64)Note > b0-b7: Trunk No. for Outgoing trunk test, ORT/IRT Test, Sender Test and Digital Conference test Tone Slot No. for Tone Test 0 = DT 1 = SPDT 2 = RBT 3 = CRBT, CWT 4 = BT 5 = RBT 6 = SST, WT 7 = SDT 8 = TRG 9 = SDTT 10 = CWRBT 14 = MSC b7 b6 b5 b4 b3 b2 b1 b0 b0-b4: Dialed number digit sent by the test Trunk/Sender or Dialed number digit received by the test Register11 12 b) Dialed Number received by the test Register b4-b7b0-b3 DC0 DC1 DC2 DC3 DC4 DC5 DC6 DC7 DC8 DC9 DC10 DC11
![](/img/blank.gif)
NDA-24307 CHAPTER 3 Page 127 Issue 1 SYSTEM MESSAGES This message displays when a call terminates to the Emergency Telephone. ➀ ~ ➅ Called Station (Emergency Telephone) No. (ASCII Code) ➆ ~ Calling Station No. (ASCII Code) 1: XXXX XXXX XXXX XXXX 2: XXXX XXXX 0000 0000 3: 0000 0000 0000 0000 ➀ ➁ ➂ ➃ ➄ ➅ ➆ ➇➈ ➉ 4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000 b7 b6 b5 b4 b3 b2 b1 b0 b7 b6 b5 b4 b3 b2 b1 b0 Default Alarm: SUP6-JEmergency CallDefault Grade: 3Grade Modified: Lamp Modified: ➀DC0 (1st digit) ➁DC1 (2nd digit) ➂DC2 (3rd digit) ➃DC3 (4th digit) ➄DC4 (5th digit) ➅DC5 (6th digit) ➆DC0 (1st digit) ➇DC1 (2nd digit) ➈DC2 (3rd digit) ➉DC3 (4th digit) DC4 (5th digit) DC5 (6th digit) 11 12 12 1211
![](/img/blank.gif)
CHAPTER 3 NDA-24307 Page 128 Issue 1 SYSTEM MESSAGES This message displays when the LCR-Attendant Manual Override is set at the Attendant/Desk Console. ➀ Route Selection Time Pattern No. assigned at Attendant/Desk Console Note:Route Selection Time Pattern 0-7 corresponds to TDPTN No. 0-7 in the AOPR command. 1: XX00 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000 ➀ 4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000 b2 b1 b0 Default Alarm: NON6-LEmergency Control StartDefault Grade: 3Grade Modified: Lamp Modified: b0-b2: Pattern No. (1-7)
![](/img/blank.gif)
NDA-24307 CHAPTER 3 Page 129 Issue 1 SYSTEM MESSAGES This message displays when the LCR-Attendant Manual Override is cancelled at the Attendant/Desk Console. ➀ Suspension of Emergency Control Note:Route Selection Patterns 0-7 corresponds to TDPTN No. 0-7 in the AOPR command. 1: XX00 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000 ➀ 4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000 b0 Default Alarm: NON6-MEmergency Control StopDefault Grade: 3Grade Modified: Lamp Modified: b0: Fixed 0. 0 = Outgoing call restriction is released by Attendant/Desk Console
![](/img/blank.gif)
CHAPTER 3 NDA-24307 Page 130 Issue 1 SYSTEM MESSAGES This message displays when the system detects abnormal duration in the line connection between the calling and called party. When the calling and called party establish a line connection and continue the hook-up for an extremely short or long period of time (predetermined by the ASYD command (SYS1, INDEX45, 46)), this message is created. ➀ Calling party information ➁ Tenant No. of Calling/Called party (Hex.) ➂ Calling party Information When calling party is Station Calling station No. (See table) 1: XXXX XXXX XXXX XX00 2: XXXX XXXX XXXX XXXX 3: XXXX XXXX XXXX XX00 ➀ ➁ ➁ ➂ ➂ ➂ ➂ ➃ ➄ ➄ ➄ ➄ ➄ ➄ ➄ ➄ ➄ ➄ ➄ ➄ ➄ ➄ 4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000 b7 b3 b2 b1 b0 b7 b6 b5 b4 b3 b2 b1 b0 Default Alarm: NON6-NAbnormal Call Duration DataDefault Grade: 0Grade Modified: Lamp Modified: b0-b3: Type of Calling party 0 = Station 1 = Attendant console 2 = Trunk b7: 0/1 = Short/Long Time b4-b7b0-b3 DC0 DC1 DC2 DC3 DC4 DC5
![](/img/blank.gif)
NDA-24307 CHAPTER 3 Page 131 Issue 1 SYSTEM MESSAGES When calling party is ATTCON/DESKCON Attendant/Desk console No. (See table.) When calling party is Trunk Route No. and Trunk No. (See table.) Note: Route No. (a) Route No. (b) ➃ Called party information b7 b6 b5 b4 b3 b2 b1 b0 b7 b6 b5 b4 b3 b2 b1 b0 b3 b2 b1 b0 b3 b2 b1 b0 b4- b7b0-b3 DC0 DC1 b0-b7 (a) Route No. (Hex) Note (b) Route No. (Hex) Note (c) Trunk No. (Hex) (d) Trunk No. (Hex) b0-b5: Route No. (1-63) b6: OP 0/1 = Data in OPRT is invalid/valid b7: AC 0/1 = Internal trunk/External trunk b0-b3: OPRT Route No. (Over 64) b0-b3: 00 = Station-to-Station call 01 = Outgoing call to outside 02 = Incoming call from outside
![](/img/blank.gif)
CHAPTER 3 NDA-24307 Page 132 Issue 1 SYSTEM MESSAGES ➄ Called Party Information Station to Station Call OG Call to outside IC Call from outside b4-b7 b0-b3 (a) Te n a n t N o . Te n a n t N o . DC0 DC1 DC2 DC3 DC4 DC5(a) Type of called party 00 = Station b7 b6 b5 b4 b3 b2 b1 b0 b0-b7 Route No. (Hex) Route No. (Hex) Trunk No. (Hex) Trunk No. (Hex)b4-b7 b0-b3 Route No. (Hex) Route No. (Hex) Trunk No. (Hex) Trunk No. (Hex) DC0 DC1 DC2 DC3 DC4 DC5 DC6 DC7 DC8 DC9 DC10 DC11 DC12 DC13 DC14 DC15 DC16 DC17 DC18 DC19