    							NDA-24307 CHAPTER 4
    Page 273
    Issue 1
    UNIT/CIRCUIT CARD REPLACEMENT PROCEDURE
    Figure 4-3   How to Replace the CPU
    ..... .....
    12
    34
    567
    812
    34
    567
    812
    345A
    SLOT No.    0 1 2 3
    45 6
    26E
    ..... .....
    12
    34
    567
    812
    34
    567
    8
    12
    345A
    SLOT No.   
    0
    1
    2
    3
    4
    5
    6
    26E
    CPR
    LPM
    IMG 0 
    						
    							CHAPTER 4 NDA-24307
    Page 274
    Issue 1
    UNIT/CIRCUIT CARD REPLACEMENT PROCEDURE
    Replacement Procedure
    Note:ACT/STBY of CPR can also be performed by using the CMODI/CMOD command. For details, refer to
    Chapter 8, Maintenance Commands.
    System Changeover of the CPU from 
    AC T  to ST B Y m od e.
    IMG0 lamp on the DSP begin to flash 
    green.
    Check the mate CPU’s lamp indications:
    At the ISW
    CPU OPE=Steady green
    IMG0 ~ IMG3=Steady green
    at the LN
    CPU OPE=Steady green
    IMG0 ~ IMG3=Flash green
    Note:
    IMG2 - IMG3 lamps may be
    OFF depending on the system
    configuration
    EMA SUP lamp on the EMA card lights 
    green.
    Cable Name to be disconnected
    CPU 0: 10AL-(110) FLT CA
    CPU 1: 10AL-(130) FLT CA
    START
    Make a backup copy of the main data (office data, 
    CF/SPD data, etc.) onto the hard disk of the HFD.
    Turn ON the MBR key on the DSP of the CPU
    to be replaced. Then turn OFF the MBR key again.
    Confirm the mate CPUs ACT mode.
    Turn ON the EMA SUP key on the 
    EMA (PH-PC40) card.
    Disconnect the power alarm cable from 
    the PALM connector on PZ-PW92.
    A
    IMG1 IMG2 IMG3 CPUOPE WDT IMG0
    12
    34
    567
    8
    OFF
    12
    34
    567
    8
    OFF
    12
    34
    OFF
    MBR
    FRONT VIEWDSP
    ON
    4C026AE
    AT T E N T I O NContents
    Static Sensitive
    Handling
    Precautions Required
    PWR (PZ-PW92)
    FRONT VIEW
    SW
    ON
    OFF
    PALM -48V
    ON
    ALM OUTPWR
    INPWR 
    						
    							NDA-24307 CHAPTER 4
    Page 275
    Issue 1
    UNIT/CIRCUIT CARD REPLACEMENT PROCEDURE
    ATTENTIONContents
    Static Sensitive
    Handling
    Precautions Required
    Refer to Figure 4-2 for 
    CPR face layout.
    Refer to Figure 4-2 for 
    CPR face layout.
    Refer to Figure 4-3 to
    replace the CPU.
    Cables to be disconnected
    Ether cable: UTP CTG5 ST CA-n
    Note:
     The kind of Ethernet cable may vary, 
    Disconnect power cables from the OUTPWR
    connector and INPWR connector on PZ-PW92.
    Disconnect Ethernet cables from the front
    connectors on the PZ-PC19 (LANI).
    Remove the four screws fastened onto the CPR.
    (Keep the removed screws.)
    B
    A
    Turn OFF the SW key on PZ-PW92.
    Disconnect bus cables from the front connectors
    on the PZ-GT13/PZ-GT20 (ISAGT).
    Cables to be disconnected from front
    EXGT BUS CA-A for CN-M connector
    depending on its connecting
    conditions. Cable to be disconnected from OUTPWR
    CPU 0: 6P-(4P-3P) PWR CA-A
    CPU 1: 6P-(4P-3P) PWR CA-B
    Cable to be disconnected from INPWR
    CPU 0: 4P-2P PWR CA-A
    CPU 1: 4P-2P PWR CA-B
    PWR (PZ-PW92)
    FRONT VIEW
    SW
    ON
    OFF
    PALM -48V
    ON
    ALM OUTPWR
    INPWR
    connector of PZ-GT13
    34PH 50AL CA-A for CN-T connector
    34PH 50AL CA-B (in LN only) Cables to be disconnected from front
    connector of PZ-GT20 
    						
    							CHAPTER 4 NDA-24307
    Page 276
    Issue 1
    UNIT/CIRCUIT CARD REPLACEMENT PROCEDURE
    ATTENTIONContents
    Static Sensitive
    Handling
    Precautions Required
    Refer to Figure 4-3 to replace
    the CPU.
    Refer to Circuit Card Installation
    Into New CPR procedure in this
    section.C
    B
    Extract the CPR from the LPM.
    Mount the ISAGT (PZ-GT13/PZ-GT20) and 
    LANI (PZ-PC19) cards onto the new CPR. 
    Then, insert the new CPR into the LPM. 
    						
    							NDA-24307 CHAPTER 4
    Page 277
    Issue 1
    UNIT/CIRCUIT CARD REPLACEMENT PROCEDURE
    ATTENTIONContents
    Static Sensitive
    Handling
    Precautions Required
    Note: Do not connect the cable for the 
    Connect the disconnected bus cables to the
    front connectors on the PZ-GT13/PZ-GT20.
    Turn ON the SW key on PZ-PW92.
    Connect the disconnected power alarm cable
    to the PALM connector on PZ-PW92.
    D
    C
    Connect the disconnected Ethernet cables
    Connect the disconnected power cables to 
    the OUTPWR and INPWR connectors.
    PALM connector yet.
    to the connectors on the PZ-PC19.
    PWR (PZ-PW92)
    FRONT VIEW
    SW
    ON
    OFF
    PALM -48V
    ON OUTPWR
    INPWR
    ALM 
    						
    							CHAPTER 4 NDA-24307
    Page 278
    Issue 1
    UNIT/CIRCUIT CARD REPLACEMENT PROCEDURE
    ATTENTIONContents
    Static Sensitive
    Handling
    Precautions Required
    EMA SUP lamp on the 
    EMA card goes OFF.
    IMG0 lamp on the DSP 
    flashes green.
    Flip the MBR key on the DSP of the new 
    CPR from ON to OFF.
    END
    D
    Turn OFF the EMA-SUP key on the EMA
    (PH-PC40) card.
    Confirm that IPL has completed successfully.
    Initial Program Load (IPL) 
    starts automatically.
    MBR(DSP)
    IMG1 IMG2 IMG3 CPUOPE WDT IMG0
    12
    34
    567
    8
    OFF
    12
    34
    567
    8
    OFF
    12
    34
    OFF
    MBR
    FRONT VIEWDSP
    ON
    4C026AE 
    						
    							NDA-24307 CHAPTER 4
    Page 279
    Issue 1
    UNIT/CIRCUIT CARD REPLACEMENT PROCEDURE
    Circuit Card Installation Into New CPR
    This procedure shows how to install the new CPR into the LPM.
    (1) Detach the front panel of the new CPR by using the Phillips screwdriver to remove
    the four screws, as shown in Figure 4-4. Then, lift the top cover by removing the
    eight screws.
    Figure 4-4   Removal of Front Panel and Top Cover From CPR
    ATTENTIONContents
    Static Sensitive
    Handling
    Precautions Required
    Top Cover
    CPRFront Panel 
    						
    							CHAPTER 4 NDA-24307
    Page 280
    Issue 1
    UNIT/CIRCUIT CARD REPLACEMENT PROCEDURE
    (2) Insert the ISAGT (PZ-GT13/PZ-GT20) and LANI (PZ-PC19) cards into the
    following slots of the new CPR (refer to Figure 4-5):
    ISAGT (PZ-GT13) →Slot 6 (ISA)
    ISAGT (PZ-GT20) →Slot 5 (ISA) (When LN has more than two IMGs) 
    Note
    LANI (PZ-PC19) →Slot 0 (PCI) (For Fusion Link)
    LANI (PZ-PC19) →Slot 1 (PCI) (When connecting MAT via 10-BASE T and PCI buses)
    LANI (PZ-PC19) →Slot 3 (PCI) (When LANI for Fusion Link is in dual configuration)
    Figure 4-5 shows how to insert the ISAGT and LANI cards into the PCI slots 5 and 6, 0 and 1 and 3 of the
    CPR, respectively.
    Note:This card is mounted in LN only.
    Figure 4-5   Insertion of ISAGT and LANI Cards
    ATTENTIONContents
    Static Sensitive
    Handling
    Precautions Required
    CPR
    Slot 6 (ISA)
    ISAGT
    LANI
    Slot 5 (ISA)
    Slot 3 (PCI)Slot 1 (PCI)Slot 0 (PCI)
    Note:Actual installation of the LANI card may differ, depending on your system configuration. 
    						
    							NDA-24307 CHAPTER 4
    Page 281
    Issue 1
    UNIT/CIRCUIT CARD REPLACEMENT PROCEDURE
    (3) Reattach the top cover by fastening the removed eight screws. Then, reattach the
    front panel by fastening the removed four screws. Refer to Figure 4-6).
    Figure 4-6   Reattachment of CPR Top Cover and Front Panel
    ATTENTIONContents
    Static Sensitive
    Handling
    Precautions Required
    Top Cover
    CPRFront Panel 
    						
    							CHAPTER 4 NDA-24307
    Page 282
    Issue 1
    UNIT/CIRCUIT CARD REPLACEMENT PROCEDURE
    (4) After turning ON the MBR key on the DSP of the new CPR, insert the new CPR into
    the LPM as shown in Figure 4-7. Then, fasten the retained four screws.
    Figure 4-7   Accommodation of New CPR Into LPM
    ATTENTIONContents
    Static Sensitive
    Handling
    Precautions Required
    CPR LPM 
    						