NDA-24307 CHAPTER 3 Page 63 Issue 1 SYSTEM MESSAGES This message displays when a B-level infinite loop failure occurs. βInformation on Self-CPU Restart after detection of a clock fault β Mate-CPU Restart Information β B-level Infinite Loop β Data to be Analyzed by NEC Engineers See Chapter 5 for repair procedure. 0-F Memory Failure 1: XXXX XXXX XXXX XXXX 2: XXXX XXXX XXXX XXXX 3: XXXX XXXX XXXX XXXX β β β β 4: XXXX XXXX XXXX XXXX 5: XXXX XXXX XXXX XXXX 6: XXXX XXXX XXXX XXXX β 7: XXXX XXXX XXXX XXXX 8: XX00 0000 0000 0000 9: 0000 0000 0000 0000 β b7 b5 b4 b3 b0 b7 b5 b4 b3 b0 b1 b0 b7 b6 b5 b4 b3 b2 b1 b0 Default Alarm: MN0-GB-Level Infinite Loop (Permanent)Default Grade: 2Grade Modified: Lamp Modified: b0: 0/1 = -/Monitor Restart b3: 0/1 = -/Initialization b4: 0/1 = -/Data Copy restart (for Dual-CPU system only) b5: 0/1 = -/MB control b7: 0/1 = ACT/STBY (active system indication after restart) b0: 0/1 = -/Monitor Restart b3: 0/1 = -/Initialization b4: 0/1 = -/Data Copy Restart (for Dual-CPU system only) b5: 0/1 = -/MB control b7: 0/1 = ACT/STBY (active system indication after restart) b0: 0/1 = -/B-level Infinite Loop b1: 0/1 = -/Task Timer Timeout
CHAPTER 3 NDA-24307 Pag e 6 4 Issue 1 SYSTEM MESSAGES This message displays when, in the CPU program processing, the counter value to check the normality of the processing has become abnormal. β Self-CPU Restart Information β Mate-CPU Restart Information (FF H: not mounted) β β Data analyzed by NEC Engineers See Chapter 5 for repair procedure. 1: XXXX XXXX XXXX XXXX 2: XXXX XXXX XXXX XXXX 3: XXXX XXXX XXXX XXXX β β β β β β 4: XXXX XXXX XXXX XXXX 5: XXXX XXXX XXXX XXXX 6: XXXX XXXX XXXX XXXX βββ 7: XXXX XXXX XXXX XXXX 8: XX00 0000 0000 0000 9: 0000 0000 0000 0000 ββ b7 b5 b4 b3 b0 b7 b5 b4 b3 b0 b1 b0 Default Alarm: SUP0-HB-Level Infinite Loop (Temporary)Default Grade: 1Grade Modified: Lamp Modified: b0: 0/1 = -/Monitor Restart b3: 0/1 = -/Initialization b4: 0/1 = -/Data Copy restart (for Dual-CPU system only) b5: 0/1 = -/MB control b7: 0/1 = ACT/STBY (active system indication after restart) b0: 0/1 = -/Monitor Restart b3: 0/1 = -/Initialization b4: 0/1 = -/Data Copy restart (for Dual-CPU system only) b5: 0/1 = -/MB control b7: 0/1 = ACT/STBY (active system indication after restart) b0: 0/1 = -/B-level Infinite Loop b1: 0/1 = -/Task Timer Timeout
NDA-24307 CHAPTER 3 Page 65 Issue 1 SYSTEM MESSAGES This message displays when a fault, such as the Clock down or C-level infinite loop error, has occurred. β STBY-side CPU Fault Information See Chapter 5 for repair procedure. 1: XX00 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000 β 4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000 b3 b2 b1 b0 Default Alarm: SUP0-IMate CPU FailureDefault Grade: 3Grade Modified: Lamp Modified: b0: 0/1 = -/CPU clock down b1: 0/1 = -/C-level infinite loop b2: 0/1 = -/Memory error, Parity alarm b3: 0/1 = -/Emergency Timer Overflow
CHAPTER 3 NDA-24307 Pag e 6 6 Issue 1 SYSTEM MESSAGES This message displays when the CPU detects abnormal interruption. β Self-CPU Restart Information β Mate-CPU Restart Information (FF H: not mounted) β β Data analyzed by NEC Engineers See Chapter 5 for repair procedure. 1: XXXX XXXX XXXX XXXX 2: XXXX XXXX XXXX XXXX 3: XXXX XXXX XXXX XXXX β β β β β β β 4: XXXX XXXX XXXX XXXX 5: XXXX XXXX XXXX XXXX 6: XXXX XXXX XXXX XXXX βββ 7: XXXX XXXX XXXX XXXX 8: XX00 0000 0000 0000 9: 0000 0000 0000 0000 ββ b7 b5 b4 b3 b0 b7 b5 b4 b3 b0 b1 b0 Default Alarm: SUP0-JAbnormal InterruptDefault Grade: 2Grade Modified: Lamp Modified: b0: 0/1 = -/Monitor Restart b3: 0/1 = -/Initialization b4: 0/1 = -/Data Copy restart (for Dual-CPU system only) b5: 0/1 = -/MB control b7: 0/1 = ACT/STBY (active system indication after restart) b0: 0/1 = -/Monitor Restart b3: 0/1 = -/Initialization b4: 0/1 = -/Data Copy restart (for Dual-CPU system only) b5: 0/1 = -/MB control b7: 0/1 = ACT/STBY (active system indication after restart) b0: 0/1 = -/Abnormal Interruption (Hardware) b3: 0/1 = -/Program Exception
NDA-24307 CHAPTER 3 Page 67 Issue 1 SYSTEM MESSAGES This message displays when link information cannot be written into the switch memory of the TSW in both systems. βTSW system in which a fault is detected β Status at the time of fault detection β Data analyzed by NEC Engineers See Chapter 5 for repair procedure. 1: XXXX XXXX XXXX XXXX 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000 β β β 4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000 b0 b6 b0 Default Alarm: MN1-ABoth TSW Failure (Permanent)Default Grade: 3Grade Modified: Lamp Modified: b0: 0/1 = TSW No. 0/TSW No. 1 b0: 0/1 = TSW No. 0 system/TSW No. 1 system b6: Speech Path in ACT status 0/1 = No. 0 system/No. 1 system
CHAPTER 3 NDA-24307 Pag e 6 8 Issue 1 SYSTEM MESSAGES This message displays when link information cannot be written into the switch memory of the TSW card in one of the dual systems. βTSW system in which a fault is detected β Status at the time of fault detection β Data analyzed by NEC Engineers See Chapter 5 for repair procedure. 1: XXXX XXXX XXXX XXXX 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000 β β β 4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000 b0 b6 b0 Default Alarm: MN1-BTSW Failure (Permanent)Default Grade: 3Grade Modified: Lamp Modified: b0: 0/1 = TSW No. 0/TSW No. 1 b0: 0/1 = TSW No. 0/TSW No. 1 b6: 0/1 = Speech Path in ACT status No. 0 system/No. 1 system
NDA-24307 CHAPTER 3 Page 69 Issue 1 SYSTEM MESSAGES This message displays when the link information cannot be written into the switch memory of the TSW in both systems. βTSW system in which a fault is detected β β Data analyzed by NEC Engineers See Chapter 5 for repair procedure. 1: XXXX XXXX XXXX XXXX 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000 β β β 4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000 b0 b6 b0 Default Alarm: MN1-CBoth TSW Write FailureDefault Grade: 2Grade Modified: Lamp Modified: b0: 0/1 = TSW No. 0/TSW No. 1 b0: 0/1 = TSW No. 0/TSW No. 1 b6: 0/1 = Speech Path in ACT status No. 0 system/No. 1 system
CHAPTER 3 NDA-24307 Pag e 7 0 Issue 1 SYSTEM MESSAGES This message displays when the link information cannot be written into the switch memory of the TSW card in one of the dual systems. βTSW system in which a fault is detected β Status at the time of fault detection β Data analyzed by NEC Engineers See Chapter 5 for repair procedure. 1: XXXX XXXX XXXX XXXX 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000 β β β 4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000 b0 b6 b0 Default Alarm: MN1-DTSW Write FailureDefault Grade: 2Grade Modified: Lamp Modified: b0: 0/1 = TSW No. 0/TSW No. 1 b0: 0/1 = TSW No. 0/TSW No. 1 b6: 0/1 = Speech Path ACT status TSW No. 0 system is ACT/TSW No. 1 system is ACT
NDA-24307 CHAPTER 3 Page 71 Issue 1 SYSTEM MESSAGES This message displays when the system detects a clock failure, such as TSW internal clock down or Frame Head down, in both systems. βTSW card in which a fault is detected β Clock status of No. 0 TSW β Clock status of No. 1 TSW Note:Refer to the meaning of β. See Chapter 5 for repair procedure. 1: XXXX XX00 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000 β β β 4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000 b1 b0 b7 b6 b2 Default Alarm: MN1-EBoth TSW Clock FailureDefault Grade: 3Grade Modified: Lamp Modified: b0: 0/1 = -/Clock failure of No. 0 TSW b1: 0/1 = -/Clock failure of No. 1 TSW b2: 0/1 = -/DTG output down b6: 0/1 = -/External 32 ch Clock (PLO) No. 0 System down b7: 0/1 = -/External 32 ch Clock (PLO) No. 1 System down
CHAPTER 3 NDA-24307 Pag e 7 2 Issue 1 SYSTEM MESSAGES This message displays when the system detects a clock failure, such as TSW internal clock down or Frame Head down in one of the dual systems. βTSW card in which a fault is detected β Clock status of No. 0 TSW β Clock status of No. 1 TSW Note:Refer to the meaning of β. See Chapter 5 for repair procedure. 1: XXXX XX00 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000 β ββ 4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000 b1 b0 b7 b6 b2 Default Alarm: MN1-FTSW Clock FailureDefault Grade: 3Grade Modified: Lamp Modified: b0: 0/1 = -/Clock failure of No. 0 TSW b1: 0/1 = -/Clock failure of No. 1 TSW b2: 0/1 = -/DTG output down b6: 0/1 = -/External 32 ch Clock (PLO) No. 0 System down b7: 0/1 = -/External 32 ch Clock (PLO) No. 1 System down