    							NDA-24307 CHAPTER 3
    Page 233
    Issue 1
    SYSTEM MESSAGES
    ➂ Day/Night Mode Specification
    ➃ External Switch Status b7 b6 b5 b4 b3 b2 b1 b0
    b7 b6 b5 b4 b3 b2 b1 b0
    b0-b3:  Mode after changing (Refer to table below)
    b4-b7:  Mode before changing (Refer to table below)
    Note:
    This data is programmed as initial data.
    b0b1b2b3
    MEANING
    b4b5b6b7
    0000Day Mode
    0 0 0 1 Night Mode 1
    0 0 1 0 Night Mode 2 (available only for Japan)
    0011Night Mode 3 (DIT-Night Connection Fixed) 
    Note
    b0-b7:
    01=Not used
    02=Day/Night Change
    03=Not used 
    						
    							CHAPTER 3 NDA-24307
    Page 234
    Issue 1
    SYSTEM MESSAGES
    This message displays when the MB switch on the IOC card has turned ON when extracting or inserting a
    circuit card.
    ➀ Circuit Card No.
    1: XX00 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀ 
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b0
    Default Alarm:
    NON17-OIOC MB Key Turn ONDefault Grade:
    3Grade Modified: Lamp Modified:
    b0: 0/1 = IOC 0/IOC 1 
    						
    							NDA-24307 CHAPTER 3
    Page 235
    Issue 1
    SYSTEM MESSAGES
    This message displays when the MB switch on the IOC card has turned OFF.
    ➀ Circuit Card No.
    1: XX00 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀ 
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b0
    Default Alarm:
    NON17-PIOC MB Key Turn OFFDefault Grade:
    3Grade Modified: Lamp Modified:
    b0: 0/1 = IOC 0/IOC 1 
    						
    							CHAPTER 3 NDA-24307
    Page 236
    Issue 1
    SYSTEM MESSAGES
    This message displays when the MBR switch on the IOC card has turned ON at the time of CPU changeover
    or speech path changeover.
    ➀ Circuit Card No.
    1: XX00 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀ 
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b0
    Default Alarm:
    NON17-QIOC MBR Key Turn ONDefault Grade:
    3Grade Modified: Lamp Modified:
    b0: 0/1 = IOC 0/IOC 1 
    						
    							NDA-24307 CHAPTER 3
    Page 237
    Issue 1
    SYSTEM MESSAGES
    This message displays when the MBR switch on the IOC card has turned OFF at the time of CPU changeover
    or speech path changeover.
    ➀ Circuit Card No.
    1: XX00 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀ 
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b0
    Default Alarm:
    NON17-RIOC MBR Key Turn OFFDefault Grade:
    3Grade Modified: Lamp Modified:
    b0: 0/1 = IOC 0/IOC 1 
    						
    							CHAPTER 3 NDA-24307
    Page 238
    Issue 1
    SYSTEM MESSAGES
    This message displays when the MBR switch on the IOGT (PH-GT10) card in ISW is turned ON.
    ➀ IOGT card system status
    ➁ IOGT card system status after key 
    operation
    Note 1:If the MBR key on the active IOGT card is flipped, the ACT/STBY of Speech Path Systems within the
    whole system is totally changed over. For more details, refer to Chapter 6, Chapter 12.
    Note 2:“1” is always displayed in the bit data.
    1: XXXX XX00 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀ ➁
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b0
    b7
    Default Alarm:
    NON17-YGATE-HSW MBR Key ONDefault Grade:
    3Grade Modified: Lamp Modified:
    b0: 0/1 = No. 0 system/No. 1 system
    b7: 0/1 = Normal/MB Note 1 
    						
    							NDA-24307 CHAPTER 3
    Page 239
    Issue 1
    SYSTEM MESSAGES
    This message displays when the MBR switch on the IOGT (PH-GT10) card in ISW is turned OFF.
    ➀ IOGT card system status
    ➁ IOGT card system status after key 
    operation
    Note:If failure occurs on the HSW card side, the IOGT card is placed in Make-Busy state and “1” is
    displayed in the bit. Otherwise, “0” is displayed.
    1: XXXX XX00 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀ ➁
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b0
    b7
    Default Alarm:
    NON17-ZGATE-HSW MBR Key OFFDefault Grade:
    3Grade Modified: Lamp Modified:
    b0: 0/1 = No. 0 system/No. 1 system
    b7: 0/1 = Normal/MB Note 
    						
    							CHAPTER 3 NDA-24307
    Page 240
    Issue 1
    SYSTEM MESSAGES
    This message displays when the Primary Dch fails, Dch Back-Up function is operated automatically.
    ➀ Condition of the Dch
    ➁ Location of the Dch (Primary)
    ➂ Location of the Dch (Back-up)
    1: XXXX XXXX XXXX 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀ ➁ ➂ ➃ ➄ ➅
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b7 b6 b5 b4 b3 b2 b1 b0
    b7 b6 b5 b4 b3 b2 b1 b0
    b7 b6 b5 b4 b3 b2 b1 b0
    Default Alarm:
    NON23-PDch Back-Up Automatic Change Start/EndDefault Grade:
    1Grade Modified: Lamp Modified:
    b0-b7:
    1 = Back-up Start
    2 = Back-up End
    3 = Back-up Failed
    b0-b4: Group No.
    b5, b6: Unit No. (0-3)
    b7: 0/1 = Even-numbered MG/Odd-numbered MG
    b0-b4: Group No.
    b5, b6: Unit No. (0-3)
    b7: 0/1 = Even-numbered MG/Odd-numbered MG 
    						
    							NDA-24307 CHAPTER 3
    Page 241
    Issue 1
    SYSTEM MESSAGES
    ➃ Changeover Information
    ➄ Status of the Primary/Back-up Dch
    ➅ EVENT No.b3 b2 b1 b0
    b5 b4 b3 b2 b1 b0
    b7 b6 b5 b4 b3 b2 b1 b0
    b0, b1:
    00 = Change from Primary Dch to Dch for Back-up
    01 = Change from Dch for Back-up to Primary Dch
    10 = Place Primary Dch to ACT status
    11 = Place Dch for Back-up to ACT status
    b2, b3:
    00 = Change signal is received
    01 = Change signal is sent
    b0-b2: Status of Primary Dch
    0 = In service (ACT status)
    1 = STBY
    2 = Out of Service
    3 = Make Busy
    4 = Changing the status from STBY to In Service
    5 = Manual Changeover out of service
    b3-b5: Status of Primary Dch
    0 = In service (ACT status)
    1 = STBY
    2 = Out of Service
    3 = Make Busy
    4 = Changing the status from STBY to In Service
    5 = Manual Changeover out of service
    b0-b7: EVENT No. 
    						
    							CHAPTER 3 NDA-24307
    Page 242
    Issue 1
    SYSTEM MESSAGES
    This message displays when the Primary Dch fails, and the Dch Back-Up function is operated manually.
    ➀ Condition of the Dch
    ➁ Location of the Dch (Primary)
    ➂ Location of the Dch (Back-up)
    1: XXXX XXXX XXXX 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀ ➁ ➂ ➃ ➄ ➅
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b7 b6 b5 b4 b3 b2 b1 b0
    b7 b6 b5 b4 b3 b2 b1 b0
    b7 b6 b5 b4 b3 b2 b1 b0
    Default Alarm:
    NON23-QDch Back-Up Manual Change Start/EndDefault Grade:
    3Grade Modified: Lamp Modified:
    b0-b7:
    1 = Back-up Start
    2 = Back-up End
    3 = Back-up Failed
    b0-b4: Group No. 
    b5, b6: Unit No. (0-3)
    b7: 0/1 = Even-numbered MG/Odd-numbered MG
    b0-b4: Group No. 
    b5, b6: Unit No. (0-3)
    b7: 0/1 = Even-numbered MG/Odd-numbered MG 
    						