NDA-24307 CHAPTER 3 Page 223 Issue 1 SYSTEM MESSAGES This message displays when the IOC card fails. ➀ IOC circuit card No. ➁ Cause for the fault 1: XXXX 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000 ➀ ➁ 4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000 b0 b4 b3 b2 b1 b0 Default Alarm: SUP16-TIOC Failure (Temporary)Default Grade: 1Grade Modified: Lamp Modified: b0: 0/1 = No. 0/No. 1 b0: 0/1 = -/COP Alarm b1: 0/1 = -/CLK Alarm b2: 0/1 = -/MEM bus CLK Alarm b3: 0/1 = -/Abnormal Interruption b4: 0/1 = -/Infinite Loop Detected
CHAPTER 3 NDA-24307 Page 224 Issue 1 SYSTEM MESSAGES This message displays when the IOC card failure, observed in the message [16-T], is detected more than eight times a day. ➀ IOC circuit card No. ➁ Cause for the fault See Chapter 4 for the Circuit Card Replacement Procedure. 1: XXXX 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000 ➀ ➁ 4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000 b0 b4 b3 b2 b1 b0 Default Alarm: SUP16-UIOC Failure (Permanent)Default Grade: 2Grade Modified: Lamp Modified: b0: 0/1 = No. 0/No. 1 b0: 0/1 = -/COP Alarm b1: 0/1 = -/CLK Alarm b2: 0/1 = -/MEM bus CLK Alarm b3: 0/1 = -/Abnormal Interruption b4: 0/1 = -/Infinite Loop
NDA-24307 CHAPTER 3 Page 225 Issue 1 SYSTEM MESSAGES This message displays when the user uses Follow Phone (SWAP) service. ➀ Error code 1: XXXX XXXX XXXX XX00 2: XXXX XXXX XXXX 00XX 3: XXXX 0000 0000 0000 ➀ ➁ ➂ ➃ ➄ ➅ ➆ ➇ ➈ ➉ 1112 13 14 14 4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000 b7 b6 b5 b4 b3 b2 b1 b0 ERROR CODE (HEX)FA I L U R EERROR CODE (HEX)FAILURE 00 Normal End 16 Called station is busy 01 MG unmatch 17 MW has been set to Calling or Called station 02 Called party is not the station 18 Call Back/OG queuing has been set to Calling or Called station 03 TEC of Calling or Called station is abnor- mal19 Call Forwarding - All Calls has been set to Calling or Called station 04 TEC unmatch 20 Call Forwarding - Busy Line has been set to Calling or Called station 05 Hunting group unmatch 21 Call Forwarding - Don’t Answer has been set to Calling or Called station 06 Call Pick Up group unmatch 22-31 - 07 Calling or Called station is Night station 32 Under processing of Data Memory Back Up 08 Call Pick Up Expand group unmatch 33Collision of swap service Under swapping of One Touch Memory Memory overflow (Max. 4 stations) Default Alarm: NON16-XStation Exchanged ReportDefault Grade: 0Grade Modified: Lamp Modified: b0-b7: See table
CHAPTER 3 NDA-24307 Page 226 Issue 1 SYSTEM MESSAGES ➁ Tenant No. of the calling station ➂ Accommodated location of the calling station after Follow Phone service ➃ Accommodated location of the calling station after Follow Phone service 09 - 34 Data Memory read error 10 Calling or Called D term has Data Line 35 Data Memory swap failure 11 Calling or Called D term has OAI function key36 OAI Terminal Information swap failure (CM Data) 12 Calling or Called station is Agent/ Supervisor (ACD)37 OAI Terminal Information swap failure (LP Data) 13-15 - 38 SST Time out b7 b6 b5 b4 b3 b2 b1 b0 b7 b6 b5 b4 b3 b2 b1 b0 b7 b6 b5 b4 b3 b2 b1 b0 ERROR CODE (HEX)FA I L U R EERROR CODE (HEX)FAILURE b0-b3: Tenant No. (1-15) b0-b7: Tenant No. (over 15) b0-b2: Level b3-b7: Group (0-22) b0, b1: Unit No. (0-3) b2-b7: MG No.
NDA-24307 CHAPTER 3 Page 227 Issue 1 SYSTEM MESSAGES ➄ ~ ➆ Station No. of the calling station ➇ Tenant No. of the called station ➈ Accommodated location of the called station ➉ Accommodated location of the called station 11 ~ 13 Station No. of the called station 14 Data Analyzed by NEC Engineers b7 b6 b5 b4 b3 b2 b1 b0 b7 b6 b5 b4 b3 b2 b1 b0 b7 b6 b5 b4 b3 b2 b1 b0 b7 b6 b5 b4 b3 b2 b1 b0 b7 b6 b5 b4 b3 b2 b1 b0 b4-b7b0-b3 ➄DC0 DC1 ➅DC2 DC3 ➆DC4 DC5 b0-b3: Tenant No. (1-15) b0-b7: Tenant No. (over 15) b0-b2: Level b3-b7: Group b0, b1: Unit No. (0-3) b2-b7: MG No. b4-b7b0-b3 11DC0 DC1 12DC2 DC3 13DC4 DC5
CHAPTER 3 NDA-24307 Page 228 Issue 1 SYSTEM MESSAGES This message displays when the MBR switch on the CCH/DCH card has turned ON. ➀ CCH/DCH Card Mounting Location ➁ CKT No. 1: XXXX 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000 ➀ ➁ 4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000 b7 b6 b5 b4 b3 b2 b1 b0 b1 b0 Default Alarm: NON17-ACCH MBR Key Turn ONDefault Grade: 3Grade Modified: Lamp Modified: b0-b4: Group No. b5, b6: Unit No. (0-3) b7: MG No. 0/1 = Even-numbered MG/Odd-numbered MG b0, b1: CKT No. (0-3)
NDA-24307 CHAPTER 3 Page 229 Issue 1 SYSTEM MESSAGES This message displays when the MBR switch on the CCH/DCH card has turned OFF. ➀ CCH/DCH Card Mounting Location ➁ CKT No. 1: XXXX 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000 ➀ ➁ 4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000 b7 b6 b5 b4 b3 b2 b1 b0 b1 b0 Default Alarm: NON17-BCCH MBR Key Turn OFFDefault Grade: 3Grade Modified: Lamp Modified: b0-b4: Group No. b5, b6: Unit No. (0-3) b7: MG No. 0/1 = Even-numbered MG/Odd-numbered MG b0, b1: CKT No. (0-3)
CHAPTER 3 NDA-24307 Page 230 Issue 1 SYSTEM MESSAGES This message displays when the MB switch on the CCH/DCH card has turned ON when extracting or inserting a circuit card or at PM initialization, etc. ➀ CCH/DCH Card Mounting Location 1: XX00 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000 ➀ 4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000 b7 b6 b5 b4 b3 b2 b1 b0 Default Alarm: NON17-CCCH MB Key Turn ONDefault Grade: 3Grade Modified: Lamp Modified: b0-b4: Group No. b5, b6: Unit No. (0-3) b7: MG No. 0/1 = Even-numbered MG/Odd-numbered MG
NDA-24307 CHAPTER 3 Page 231 Issue 1 SYSTEM MESSAGES This message displays when the MB switch on the CCH/DCH card has turned OFF when extracting or inserting a circuit card or at PM initialization, etc. ➀ CCH/DCH Card Mounting Location 1: XX00 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000 ➀ 4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000 b7 b6 b5 b4 b3 b2 b1 b0 Default Alarm: NON17-DCCH MB Key Turn OFFDefault Grade: 3Grade Modified: Lamp Modified: b0-b4: Group No. b5, b6: Unit No. (0-3) b7: MG No. 0/1 = Even-numbered MG/Odd-numbered MG
CHAPTER 3 NDA-24307 Page 232 Issue 1 SYSTEM MESSAGES This message displays when the NIGHT switch on the ATTCON/DESKCON has been operated or when the DAY/NIGHT change has been executed by the external switch operation. ➀ Tenant No. ➁ Changing Method 1: XXXX XXXX 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000 ➀ ➁ ➂ ➃ 4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000 b7 b6 b5 b4 b3 b2 b1 b0 b7 b6 b5 b4 b3 b2 b1 b0 Default Alarm: NON17-HDay/Night Change InformationDefault Grade: 0Grade Modified: Lamp Modified: b0-b3: Tenant No. (1-15) b4-b7: Tenant No. (over 15) b0-b7: 1=Night Key on the ATTCON/DESKCON 2=External Key