    							NDA-24307 CHAPTER 3
    Page 223
    Issue 1
    SYSTEM MESSAGES
    This message displays when the IOC card fails.
    ➀ IOC circuit card No.
    ➁ Cause for the fault
    1: XXXX 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀ ➁
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b0
    b4 b3 b2 b1 b0
    Default Alarm:
    SUP16-TIOC Failure (Temporary)Default Grade:
    1Grade Modified: Lamp Modified:
    b0: 0/1 = No. 0/No. 1
    b0: 0/1 = -/COP Alarm
    b1: 0/1 = -/CLK Alarm
    b2: 0/1 = -/MEM bus CLK Alarm
    b3: 0/1 = -/Abnormal Interruption
    b4: 0/1 = -/Infinite Loop Detected 
    						
    							CHAPTER 3 NDA-24307
    Page 224
    Issue 1
    SYSTEM MESSAGES
    This message displays when the IOC card failure, observed in the message [16-T], is detected more than eight
    times a day.
    ➀ IOC circuit card No.
    ➁ Cause for the fault
    See Chapter 4 for the Circuit Card Replacement Procedure.
    1: XXXX 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀ ➁
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b0
    b4 b3 b2 b1 b0
    Default Alarm:
    SUP16-UIOC Failure (Permanent)Default Grade:
    2Grade Modified: Lamp Modified:
    b0: 0/1 = No. 0/No. 1
    b0: 0/1 = -/COP Alarm
    b1: 0/1 = -/CLK Alarm
    b2: 0/1 = -/MEM bus CLK Alarm
    b3: 0/1 = -/Abnormal Interruption
    b4: 0/1 = -/Infinite Loop 
    						
    							NDA-24307 CHAPTER 3
    Page 225
    Issue 1
    SYSTEM MESSAGES
    This message displays when the user uses Follow Phone (SWAP) service.
    ➀ Error code
    1: XXXX XXXX XXXX XX00 2: XXXX XXXX XXXX 00XX 3: XXXX 0000 0000 0000
    ➀ ➁ ➂ ➃ ➄ ➅ ➆ ➇ ➈ ➉ 1112 13 14 14
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b7 b6 b5 b4 b3 b2 b1 b0
    ERROR 
    CODE (HEX)FA I L U R EERROR 
    CODE (HEX)FAILURE
    00 Normal End 16 Called station is busy
    01 MG unmatch 17 MW has been set to Calling or Called 
    station
    02 Called party is not the station 18 Call Back/OG queuing has been set to 
    Calling or Called station
    03 TEC of Calling or Called station is abnor-
    mal19 Call Forwarding - All Calls has been set to 
    Calling or Called station
    04 TEC  unmatch 20 Call Forwarding - Busy Line has been set to 
    Calling or Called station
    05 Hunting group unmatch 21 Call Forwarding - Don’t Answer has been 
    set to Calling or Called station
    06 Call Pick Up group unmatch 22-31 -
    07 Calling or Called station is Night station 32 Under processing of Data Memory Back 
    Up
    08 Call Pick Up Expand group unmatch 33Collision of swap service
    Under swapping of One Touch Memory
    Memory overflow (Max. 4 stations)
    Default Alarm:
    NON16-XStation Exchanged ReportDefault Grade:
    0Grade Modified: Lamp Modified:
    b0-b7: See table 
    						
    							CHAPTER 3 NDA-24307
    Page 226
    Issue 1
    SYSTEM MESSAGES
    ➁ Tenant No. of the calling station
    ➂ Accommodated location of the 
    calling station after Follow Phone 
    service
    ➃ Accommodated location of the 
    calling station after Follow Phone 
    service
    09 - 34 Data Memory read error
    10 Calling or Called D
    term has Data Line 35 Data Memory swap failure
    11 Calling or Called D
    term has OAI function 
    key36 OAI Terminal Information swap failure 
    (CM Data)
    12 Calling or Called station is Agent/
    Supervisor (ACD)37 OAI Terminal Information swap failure 
    (LP Data)
    13-15 - 38 SST Time out
    b7 b6 b5 b4 b3 b2 b1 b0
    b7 b6 b5 b4 b3 b2 b1 b0
    b7 b6 b5 b4 b3 b2 b1 b0
    ERROR 
    CODE (HEX)FA I L U R EERROR 
    CODE (HEX)FAILURE
    b0-b3: Tenant No. (1-15)
    b0-b7: Tenant No. (over 15)
    b0-b2: Level
    b3-b7: Group (0-22)
    b0, b1: Unit No. (0-3)
    b2-b7: MG No. 
    						
    							NDA-24307 CHAPTER 3
    Page 227
    Issue 1
    SYSTEM MESSAGES
    ➄ ~ ➆ Station No. of the calling 
    station
    ➇ Tenant No. of the called station
    ➈ Accommodated location of the 
    called station
    ➉ Accommodated location of the 
    called station
    11 ~ 13 Station No. of the called 
    station
    14 Data Analyzed by NEC Engineers b7 b6 b5 b4 b3 b2 b1 b0
    b7 b6 b5 b4 b3 b2 b1 b0
    b7 b6 b5 b4 b3 b2 b1 b0
    b7 b6 b5 b4 b3 b2 b1 b0
    b7 b6 b5 b4 b3 b2 b1 b0
    b4-b7b0-b3
    ➄DC0 DC1
    ➅DC2 DC3
    ➆DC4 DC5
    b0-b3: Tenant No. (1-15)
    b0-b7: Tenant No. (over 15)
    b0-b2: Level
    b3-b7: Group
    b0, b1: Unit No. (0-3)
    b2-b7: MG No.
    b4-b7b0-b3
    11DC0 DC1
    12DC2 DC3
    13DC4 DC5 
    						
    							CHAPTER 3 NDA-24307
    Page 228
    Issue 1
    SYSTEM MESSAGES
    This message displays when the MBR switch on the CCH/DCH card has turned ON.
    ➀ CCH/DCH Card Mounting 
    Location 
    ➁ CKT No.
    1: XXXX 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀ ➁
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b7 b6 b5 b4 b3 b2 b1 b0
    b1 b0
    Default Alarm:
    NON17-ACCH MBR Key Turn ONDefault Grade:
    3Grade Modified: Lamp Modified:
    b0-b4: Group No. 
    b5, b6: Unit No. (0-3)
    b7: MG No.
    0/1 = Even-numbered MG/Odd-numbered MG
    b0, b1: CKT No. (0-3) 
    						
    							NDA-24307 CHAPTER 3
    Page 229
    Issue 1
    SYSTEM MESSAGES
    This message displays when the MBR switch on the CCH/DCH card has turned OFF.
    ➀ CCH/DCH Card Mounting 
    Location
    ➁ CKT No.
    1: XXXX 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀  ➁
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b7 b6 b5 b4 b3 b2 b1 b0
    b1 b0
    Default Alarm:
    NON17-BCCH MBR Key Turn OFFDefault Grade:
    3Grade Modified: Lamp Modified:
    b0-b4: Group No.
    b5, b6: Unit No. (0-3)
    b7: MG No.
    0/1 = Even-numbered MG/Odd-numbered MG
    b0, b1: CKT No. (0-3) 
    						
    							CHAPTER 3 NDA-24307
    Page 230
    Issue 1
    SYSTEM MESSAGES
    This message displays when the MB switch on the CCH/DCH card has turned ON when extracting or inserting
    a circuit card or at PM initialization, etc.
    ➀ CCH/DCH Card Mounting 
    Location
    1: XX00 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀ 
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b7 b6 b5 b4 b3 b2 b1 b0
    Default Alarm:
    NON17-CCCH MB Key Turn ONDefault Grade:
    3Grade Modified: Lamp Modified:
    b0-b4: Group No. 
    b5, b6: Unit No. (0-3)
    b7: MG No.
    0/1 = Even-numbered MG/Odd-numbered MG 
    						
    							NDA-24307 CHAPTER 3
    Page 231
    Issue 1
    SYSTEM MESSAGES
    This message displays when the MB switch on the CCH/DCH card has turned OFF when extracting or
    inserting a circuit card or at PM initialization, etc.
    ➀ CCH/DCH Card Mounting 
    Location
    1: XX00 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀ 
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b7 b6 b5 b4 b3 b2 b1 b0
    Default Alarm:
    NON17-DCCH MB Key Turn OFFDefault Grade:
    3Grade Modified: Lamp Modified:
    b0-b4: Group No. 
    b5, b6: Unit No. (0-3)
    b7: MG No.
    0/1 = Even-numbered MG/Odd-numbered MG 
    						
    							CHAPTER 3 NDA-24307
    Page 232
    Issue 1
    SYSTEM MESSAGES
    This message displays when the NIGHT switch on the ATTCON/DESKCON has been operated or when the
    DAY/NIGHT change has been executed by the external switch operation.
    ➀ Tenant No.
    ➁ Changing Method
    1: XXXX XXXX 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀ ➁ ➂ ➃
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b7 b6 b5 b4 b3 b2 b1 b0
    b7 b6 b5 b4 b3 b2 b1 b0
    Default Alarm:
    NON17-HDay/Night Change InformationDefault Grade:
    0Grade Modified: Lamp Modified:
    b0-b3: Tenant No. (1-15)
    b4-b7: Tenant No. (over 15)
    b0-b7:
    1=Night Key on the ATTCON/DESKCON
    2=External Key 
    						