    SYSTEM MESSAGES
    This message displays when link information cannot be written into the switch memory of the TSW card in
    one of the dual systems.
    ➀TSW system in which a fault is 
    detected
    ➁ Status at the time of fault detection
    ➂ Data Analyzed by NEC Engineers
    Reference: See Chapter 5, Section 5.4, for the repair procedure.
    1: XXXX XXXX XXXX XXXX 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀ ➁ ➂
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b7 b0
    b7 b6 b0
    Default Alarm:
    MN1-BTSW Failure (Permanent)Default Grade:
    3Grade Modified: Lamp Modified:
    b0: 0/1 = TSW No. 0/TSW No. 1
    b0: 0/1 = TSW No. 0/TSW No. 1
    b6: 0/1 = Speech Path in ACT status
    No. 0 system/No. 1 system 
    						
    							NDA-24238 CHAPTER 3
    Page 55
    Revision 3.0
    SYSTEM MESSAGES
    This message displays when the link information cannot be written into the switch memory of the TSW in both
    systems.
    ➀TSW system in which a fault is 
    detected
    ➁ 
    ➂ Data Analyzed by NEC Engineers
    Reference: See Chapter 5, Section 5.2 and Section 6.2, for the repair procedure.
    1: XXXX XXXX XXXX XXXX 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀ ➁ ➂
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b7 b0
    b7 b6 b0
    Default Alarm:
    MN1-CBoth TSW Write FailureDefault Grade:
    2Grade Modified: Lamp Modified:
    b0: 0/1 = TSW No. 0/TSW No. 1
    b0: 0/1 = TSW No. 0/TSW No. 1
    b6: 0/1 = Speech Path in ACT status
    No. 0 system/No. 1 system 
    						
    							CHAPTER 3 NDA-24238
    Pag e 5 6
    Revision 3.0
    SYSTEM MESSAGES
    This message displays when the link information cannot be written into the switch memory of the TSW card
    in one of the dual systems.
    ➀TSW system in which a fault is 
    detected
    ➁ Status at the time of fault detection
    ➂ Data Analyzed by NEC Engineers
    Reference: See Chapter 5, Section 5.2, Section 5.4, and Section 6.2, for the repair procedure.
    1: XXXX XXXX XXXX XXXX 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀ ➁ ➂
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b7 b0
    b7 b6 b0
    Default Alarm:
    MN1-DTSW Write FailureDefault Grade:
    2Grade Modified: Lamp Modified:
    b0: 0/1 = TSW No. 0/TSW No. 1
    b0: 0/1 = TSW No. 0/TSW No. 1
    b6: 0/1 = Speech Path ACT status 
    TSW No. 0 system is ACT/TSW No. 1 system is ACT 
    						
    							NDA-24238 CHAPTER 3
    Page 57
    Revision 3.0
    SYSTEM MESSAGES
    This message displays when the system detects a clock failure, such as TSW internal clock down or Frame
    Head down, in both systems.
    ➀TSW card in which a fault is 
    detected
    ➁ Clock status of No. 0 TSW
    ➂ Clock status of No. 1 TSW
    Note:Refer to the meaning of ➁.
    Reference: See Chapter 5, Section 5.3, for the repair procedure.
    1: XXXX XX00 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀ ➁ ➂
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b7 b1 b0
    b7 b6 b2 b0
    Default Alarm:
    MN1-EBoth TSW Clock FailureDefault Grade:
    3Grade Modified: Lamp Modified:
    b0: 0/1 = -/TSW No. 0 system
    b1: 0/1 = -/TSW No. 1 system
    b2: 0/1 = -/DTG output down
    b6: 0/1 = -/External 32 ch Clock (PLO) No. 0 System down
    b7: 0/1 = -/External 32 ch Clock (PLO) No. 1 System down 
    						
    							CHAPTER 3 NDA-24238
    Pag e 5 8
    Revision 3.0
    SYSTEM MESSAGES
    This message displays when the system detects a clock failure, such as TSW internal clock down or Frame
    Head down, in one of the dual systems.
    ➀TSW card in which a fault is 
    detected
    ➁ Clock status of No. 0 TSW
    ➂ Clock status of No. 1 TSW
    Note:Refer to the meaning of ➁.
    Reference: See Chapter 5, Section 5.4, for the repair procedure.
    1: XXXX XX00 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀ ➁ ➂
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b7 b1 b0
    b7 b6 b2 b0
    Default Alarm:
    MJ1-FTSW Clock FailureDefault Grade:
    3Grade Modified: Lamp Modified:
    b0: 0/1 = -/TSW No. 0
    b1: 0/1 = -/TSW No. 1 system
    b2: 0/1 = -/DTG output down
    b6: 0/1 = -/External 32 ch Clock (PLO) No. 0 System down
    b7: 0/1 = -/External 32 ch Clock (PLO) No. 1 System down 
    						
    							NDA-24238 CHAPTER 3
    Page 59
    Revision 3.0
    SYSTEM MESSAGES
    This message displays when the system detects a fault, such as input clock all down or output clock down in
    the PLO cards, at both sides.
    ➀ Detected PLO number
    ➁ Valid Information bit for Scan Data 
    1
    ➂ Valid Information bit for Scan Data 
    2
    Reference: See Chapter 4, Section 2.3.2 and Section 2.3.4, for the circuit card replacement procedure.
    1: XXXX XXXX XX00 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀ ➁ ➂ ➃ ➄
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b7 b0
    b7 b6 b5 b4 b3 b2 b1 b0
    b7 b6 b5 b4 b3 b2 b1 b0
    Default Alarm:
    MJ1-OBoth PLO FailureDefault Grade:
    3Grade Modified: Lamp Modified:
    b0: 0/1 = No. 0 PLO/No. 1 PLO
    b0-b7: Bit position corresponding to the detected information in Scan Data 1 
    ( ) is flagged “1”.
    ➃
    b0-b7: Bit position corresponding to the detected information in Scan Data 2 
    ( ) is flagged “1”.
    ➄ 
    						
    							CHAPTER 3 NDA-24238
    Pag e 6 0
    Revision 3.0
    SYSTEM MESSAGES
    ➃ Scan Data 1: Current Status of PLO 
    card
    ➄ Scan Data 2: Current Status of PLO 
    card b7 b6 b5 b4 b3 b2 b1 b0
    b7 b4 b1 b0
    b0: Clock status at time of detection
    0/1 = STBY/ACT
    b1: Circuit Card status at time of detection
    0/1 = PLO synchronizing/PLO self running or drift abnormal
    b2: 0/1 = -/Input clock down
    b3, b4: Route of Input clock 
    b5: 0/1 = -/PLO input all down
    b6: 0/1 = -/PLO output down
    b7: 0/1 = -/Drifting
    b4b3DCS Input RouteRoute Of Input Clock
    00 0 0
    01 1 1
    10 - 2
    11 - 3
    b0: 0/1 = -/5msec Burst Clock down
    b1: 0/1 = -/Frame Synchronization from SYNC card is down
    b4: 0/1 = -/Internal OSC clock down 
    						
    							NDA-24238 CHAPTER 3
    Page 61
    Revision 3.0
    SYSTEM MESSAGES
    This message displays when the system detects all the failures concerned with input clock down or output clock
    down in the PLO card at the ACT side. When this message is indicated, the PLO card changeover executes.
    Note:The No. 0 PLO card automatically changes over to No. 1. The changeover of No. 1 to No. 0 is not
    automatic.
    ➀ Self-CPU Restart Information
    ➁ Valid Information bit for Scan Data 
    1
    ➂ Valid Information bit for Scan Data 
    2
    Reference: See Chapter 4, Section 2.3.2 and Section 2.3.4, for the circuit card replacement procedure.
    1:XXXX XXXX XX00 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀ ➁ ➂ ➃ ➄
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b7 b0
    b7 b6 b5 b4 b3 b2 b1 b0
    b7 b6 b5 b4 b3 b2 b1 b0
    Default Alarm:
    MN1-PPLO FailureDefault Grade:
    3Grade Modified: Lamp Modified:
    b0: 0/1 = No. 0 PLO/No. 1 PLO
    b0-b7: Bit position corresponding to the detected information in Scan Data 1 
    ( ) is flagged “1”.
    ➃
    b0-b7: Bit position corresponding to the detected information in Scan Data 2 
    ( ) is flagged “1”.
    ➄ 
    						
    							CHAPTER 3 NDA-24238
    Pag e 6 2
    Revision 3.0
    SYSTEM MESSAGES
    ➃ Scan Data 1: Status of PLO card
    ➄ Scan Data: Status of PLO card b7 b6 b5 b4 b3 b2 b1 b0
    b7 b4 b1 b0
    b0: Clock status at time of detection
    0/1 = STBY/ACT
    b1: Circuit card at time of detection
    0/1 = PLO synchronizing/PLO self running or drifting
    b2: 0/1 = -/Input clock down
    b3, b4: Route of Input clock 
    b5: 0/1 = -/PLO input all down
    b6: 0/1 = -/PLO output down
    b7: 0/1 = -/Drifting
    b4b3DCS Input RouteRoute Of Input Clock
    00 0 0
    01 1 1
    10 - 2
    11 - 3
    b0: 0/1 = -/5msec Burst Clock down
    b1: 0/1 = -/Frame Synchronization from SYNC card is down
    b4: 0/1 = -/Internal OSC clock down 
    						
    							NDA-24238 CHAPTER 3
    Page 63
    Revision 3.0
    SYSTEM MESSAGES
    This message displays when a fault of the speech path system has occurred in a specific Module Group. The
    specific Module Group is placed into make-busy state.
    ➀ MG number of fault detection
    ➁ Kind of failure
    ➂ Speech Path/Clock System
    Reference: See Chapter 4, Section 2.3.2, for the circuit card replacement procedure.
    1: XXXX XX00 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀ ➁ ➂
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b7 b0
    b7 b6 b5 b4 b3 b2 b1 b0
    b7 b1 b0
    Default Alarm:
    MJ1-SModule Group Down FailureDefault Grade:
    3Grade Modified: Lamp Modified:
    b0: 0/1 = Even-numbered MG/Odd-numbered MG
    b0-b7: 00H/01H = -/ACT side TSW fault
    b0: ACT side speech path
    0/1 = No. 0 system/No. 1 system
    b1: ACT side clock
    0/1 = No. 0 system/No. 1 system 
    						