    							CHAPTER 3 NDA-24238
    Pag e 7 4
    Revision 3.0
    SYSTEM MESSAGES
    This message displays when a wire of the line between the LC circuit card and the telephone set is short-
    circuited with ground.
    ➀ Location of faulty circuit card
    ➁ Location of faulty circuit card
    Note:This message displays when the specific LC card providing the above function is used.
    1: XXXX 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀ ➁
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b7 b6 b5 b4 b3 b2 b1 b0
    b7 b6 b5 b4 b3 b2 b1 b0
    Default Alarm:
    SUP3-GGround FailureDefault Grade:
    1Grade Modified: Lamp Modified:
    b0-b2: Circuit No. (0-7)
    b3-b7: Circuit card No. (0-31)
    b0, b1: Unit No. (0-3)
    b2-b7: MG No. (0-1) 
    						
    							NDA-24238 CHAPTER 3
    Page 75
    Revision 3.0
    SYSTEM MESSAGES
    This message displays when the DTI card detects an abnormal state of a digital line but this failure has no in-
    fluence on the speech path. When the status worsens, the system issues [3-I] Digital Line Failure message.
    ➀ Location of PM (LENS) with a 
    fault
    ➁ Kind of fault
    ➂ Time Slot No. of fault (This data is 
    valid only when the kind of fault is 
    08H.)
    1: XXXX XX00 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀ ➁ ➂ 
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b7 b6 b5 b4 b3 b2 b1 b0
    b7 b6 b5 b4 b3 b2 b1 b0
    b7 b4 b3 b2 b1 b0
    Default Alarm:
    SUP3-HDigital Line WarningDefault Grade:
    2Grade Modified: Lamp Modified:
    b0-b4: Group
    b5, b6: Unit
    b7: 0/1 = Even-numbered MG/Odd-numbered MG
    01H = Frame alignment loss occurs three times a day
    02H = Bit error rate is over 10
    -6
    03H = Slip occurs twice a day
    04H = Multiframe alignment loss occurs three times a day
    08H = Fault detection on the CCIS Bch
    b0-b4: Time slot No. in which the digital line failure occurred (1-16, 17-31) 
    						
    							CHAPTER 3 NDA-24238
    Pag e 7 6
    Revision 3.0
    SYSTEM MESSAGES
    This message displays after [3-H] Digital Line Warning lasts in the DTI card over the particular time. This
    failure may cause a speech path fault to the DTI card.
    ➀ Location of faulty PM
    ➁ Kind of fault
    ➂ Location of faulty circuit card (This 
    data is valid when 
    ➁ is 0FH)
    ➃ Location of faulty circuit card (This 
    data is valid when 
    ➁ is 0FH)
    1: XXXX 0000 XXXX XXXX 2: XXXX XXXX XXXX XXXX 3: XXXX XXXX XXXX XXXX
    ➀ ➁ ➂ ➃ ➂ ➃ ➂ ➃ ➂ ➃ ➂ ➃ ➂ ➃ ➂ ➃ ➂ ➃ ➂ ➃
    4: XXXX XXXX 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    ➂ ➃ ➂ ➃
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b7 b6 b5 b4 b3 b2 b1 b0
    b7 b6 b5 b4 b3 b2 b1 b0
    b7 b6 b5 b4 b3 b0
    b7 b6 b5 b4 b3 b2 b1 b0
    Default Alarm:
    SUP3-IDigital Line FailureDefault Grade:
    3Grade Modified: Lamp Modified:
    b0-b4: Group
    b5, b6: Unit
    b7: 0/1 = Even-numbered MG/Odd-numbered MG
    01H = Frame alignment loss occurs 100 times a day
    03H = Slip occurs 50 times a day
    04H = Multiframe alignment loss occurs 110 times a day
    06H = Frame alignment loss lasts for 2 to 3 sec.
    07H = Bit error rate is over 10
    -4
    09H = Warning signal (AIS) from the opposite office has been received for 1 
    sec. continuously.
    0BH = Multiframe alignment loss lasts for 2 to 3 sec.
    0FH = Digital Line is not restored
    b3-b7: Group No.
    b0, b1: Unit No.
    b2-b7: MG No. 
    						
    							NDA-24238 CHAPTER 3
    Page 77
    Revision 3.0
    SYSTEM MESSAGES
    This message displays when a digital line fault is restored.
    ➀ Location of faulty line
    1: XX00 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀ 
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b7 b6 b5 b4 b3 b2 b1 b0
    Default Alarm:
    NON3-JDigital Line RestoreDefault Grade:
    0Grade Modified: Lamp Modified:
    b0-b4: Group No. 
    b5, b6: Unit No. (0-3)
    b7: 0/1 = Even-numbered MG/odd-numbered MG 
    						
    							CHAPTER 3 NDA-24238
    Pag e 7 8
    Revision 3.0
    SYSTEM MESSAGES
    This message displays when a Ready Failure occurs in both systems as a result of the TSW card having a failure
    or the card is not mounted properly.
    ➀Unit and MG number of fault 
    detection
    Reference: See Chapter 5, Section 5.3, for the repair procedure.
    1: XX00 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀ 
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b7 b0
    Default Alarm:
    MN4-CBoth TSW Ready FailureDefault Grade:
    3Grade Modified: Lamp Modified:
    b0: 0/1 = TSW No. 0 system/TSW No. 1 system
    Note:
    When Ready Failure occurs in both systems, the [4-C]
    message is separately issued twice: “0” displays in one
    message, and “1” in the other message. 
    						
    							NDA-24238 CHAPTER 3
    Page 79
    Revision 3.0
    SYSTEM MESSAGES
    This message displays when a Ready Failure occurs in one of the dual systems because the TSW card fails or
    the card is not mounted properly.
    ➀Unit and MG number of fault 
    detection
    Reference: See Chapter 5, Section 5.4, for the repair procedure.
    1: XX00 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀ 
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b7 b0
    Default Alarm:
    MN4-DTSW Ready FailureDefault Grade:
    3Grade Modified: Lamp Modified:
    b0: 0/1 = TSW No. 0 system/TSW No. 1 system 
    						
    							CHAPTER 3 NDA-24238
    Pag e 8 0
    Revision 3.0
    SYSTEM MESSAGES
    This message displays when I/O Ready Failure occurs on a DLKC card.
    ➀Details on faulty DLKC card
    1: XX00 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀ 
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b7 b0
    Default Alarm:
    MN4-QDLKC Ready FailureDefault Grade:
    3Grade Modified: Lamp Modified:
    b0: 0/1 = No. 0 system/No. 1 system
    b7: 0/1 = ACT/STBY 
    						
    							NDA-24238 CHAPTER 3
    Page 81
    Revision 3.0
    SYSTEM MESSAGES
    This message displays when the MUX (PH-PC36) card has a Ready Failure in one of the dual systems. When
    the card is not ready for service function because of the failure or because the card is not mounted properly,
    the system creates this message.
    ➀Unit and MG number for MUX 
    card with ready fault
    ➁MG and system number for faulty 
    MUX card
    Reference: See Chapter 5, Section 4.3 and Section 4.4, for the repair procedure.
    1: XXXX 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀ ➁
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b7 b6 b5 b4 b3 b2 b1 b0
    b7 b2 b1 b0
    Default Alarm:
    MN4-SMUX Ready FailureDefault Grade:
    3Grade Modified: Lamp Modified:
    b0: 0/1 = -/MUX ready fault in even-numbered MG, Unit 0
    b1: 0/1 = -/MUX ready fault in even-numbered MG, Unit 1
    b2: 0/1 = -/MUX ready fault in even-numbered MG, Unit 2
    b3: 0/1 = -/MUX ready fault in even-numbered MG, Unit 3
    b4: 0/1 = -/MUX ready fault in odd-numbered MG, Unit 0
    b5: 0/1 = -/MUX ready fault in odd-numbered MG, Unit 1
    b6: 0/1 = -/MUX ready fault in odd-numbered MG, Unit 2
    b7: 0/1 = -/MUX ready fault in odd-numbered MG, Unit 3
    b0: MG number for faulty MUX card
    0/1 = Even number/Odd number
    b1: 0/1 = Ready failure in MUX No. 0 system/Ready failure in MUX No. 
    1 system
    b2: ACT or STBY status of faulty MUX.
    0/1 = ACT/STBY 
    						
    							CHAPTER 3 NDA-24238
    Pag e 8 2
    Revision 3.0
    SYSTEM MESSAGES
    This message displays when the MUX (PH-PC36) card has a Ready Failure in both of the dual systems. When
    the card is not ready for service function because of the failure or because the card is not mounted properly,
    the system creates this system message.
    ➀Unit and MG number for MUX 
    card with the ready fault
    ➁MG and system number for faulty 
    MUX card
    Note 1:Though this message indicates the Ready Failure in both systems, the information displayed here only
    relates to the ACT-side MUX status. (Two messages are not displayed separately.)
    Note 2:Fixed as “0 (=ACT).” See Note 1.
    Reference: See Chapter 5, Section 4.3 and Section 4.4, for the repair procedure.
    1: XXXX 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀ ➁
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b7 b6 b5 b4 b3 b2 b1 b0
    b7 b2 b1 b0
    Default Alarm:
    MN4-TBoth MUX Ready FailureDefault Grade:
    3Grade Modified: Lamp Modified:
    b0: 0/1 = -/MUX ready fault in even-numbered MG, Unit 0
    b1: 0/1 = -/MUX ready fault in even-numbered MG, Unit 1
    b2: 0/1 = -/MUX ready fault in even-numbered MG, Unit 2
    b3: 0/1 = -/MUX ready fault in even-numbered MG, Unit 3
    b4: 0/1 = -/MUX ready fault in odd-numbered MG, Unit 0
    b5: 0/1 = -/MUX ready fault in odd-numbered MG, Unit 1
    b6: 0/1 = -/MUX ready fault in odd-numbered MG, Unit 2
    b7: 0/1 = -/MUX ready fault in odd-numbered MG, Unit 3
    b0: MG number for faulty MUX card
    0/1 = Even number/Odd number
    b1: 0/1 = Ready failure in MUX No. 0 system/Ready failure in MUX No. 
    1 system Note 1
    b2: ACT or STBY status of the faulty MUX Note 2
    0/1 = ACT/STBY 
    						
    							NDA-24238 CHAPTER 3
    Page 83
    Revision 3.0
    SYSTEM MESSAGES
    This message displays when a PCI card failure occurs.
    ➀ Fault detection on PCI card
    ➁ Error status on PCI slot 0
    ➂ Error status on PCI slot 1
    ➃ Not used
    1: 0X0X 0X0X 0X00 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀ ➁ ➂ ➃ ➄
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b7 b3 b2 b1 b0
    b7 b1 b0
    b7 b1 b0
    Default Alarm:
    MN4-UPCI Card FailureDefault Grade:
    3Grade Modified: Lamp Modified:
    b0: 0/1 = -/Error detection on PCI slot 0 (LANI-A)
    b1: 0/1 = -/Error detection on PCI slot 1
    b2: 0/1 = -/Error detection on PCI slot 2 (Not used)
    b3: 0/1 = -/Error detection on PCI slot 3 (LANI-B)
    b0: 0/1 = -/Physical connection error Note 1
    b1: 0/1 = -/Hardware Fault Note 2
    b0: 0/1 = -/Physical connection error Note 1
    b1: 0/1 = -/Hardware Fault Note 2 
    						