CHAPTER 3 NDA-24238 Page 134 Revision 3.0 SYSTEM MESSAGES In a specific time cycle, the system allows a routine diagnosis in its hardware and software to determine if they are operating properly. This message indicates that the system has been checked by the routine diagnosis pro- gram and the result of the diagnosis is not normal. ➀ Detected Error Item Note:The data in this area will be diverse, according to the diagnosis specified in ➀. For details on each item data, see the following pages. 1: XXXX XXXX XXXX XXXX 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000 Note ➀ 4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000 b7 b6 b5 b4 b3 b2 b1 b0 Default Alarm: NON7-PCyclic Diagnosis Information (Error Detected)Default Grade: 3Grade Modified: Lamp Modified: [10H] Program Memory Verification Discrepancy [11H] Program Memory Verification Impossible (HFD Fault) [12H] Program Memory Verification Impossible (Fault at CPU side) [20H] Data Memory Verification Discrepancy [21H] Data Memory Verification Impossible (HFD Fault) [30H] TSW ACT/STBY Changeover Failure [31H] TSW ACT/STBY Changeover Failure (MUX Fault) [41H] CPU ACT/STBY Changeover Failure (Single CPU System) [42H] CPU ACT/STBY Changeover Failure (DM Verification NG) [43H] CPU ACT/STBY Changeover Failure (PCI Fault) [44H] CPU ACT/STBY Changeover Failure (Changeover NG or CPU RAM Copy NG) [50H] Trunk Ineffective Hold Detected [51H] Trunk Ineffective Hold Detected and Released [52H] Trunk Ineffective Hold Detected Impossible [70H] Call Forwarding Memory Clear NG [A0H] Periodic Backup Abnormal End [C0H] Detection of Remaining Link Abnormal End (for Release 4 or later)
NDA-24238 CHAPTER 3 Page 135 Revision 3.0 SYSTEM MESSAGES [10H] Program Memory Verification Discrepancy ➀ Error detection by Routine Diagnosis ➁ Verification of HFD number ➂ Verification of Drive Number ➃ Data analyzed by NEC Engineers 1: 1000 XXXX XXXX XXXX 2: XXXX 0000 0000 0000 3: 0000 0000 0000 0000 ➀ ➁ ➂ ➃ 4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000 b7 b1 b0 b7 b3 b2 b1 b0 [10H] Program Memory Verification Discrepancy b0: 0/1 = -/HFD 0 b1: 0/1 = -/HFD 1 b0: 0/1 = -/Drive Number 0 b1: 0/1 = -/Drive Number 1 b2: 0/1 = -/Drive Number 2 b3: 0/1 = -/Drive Number 3
CHAPTER 3 NDA-24238 Page 136 Revision 3.0 SYSTEM MESSAGES [11H] Program Memory Verification Impossible (HFD Fault) ➀ Error detection by Routine Diagnosis ➁ Verification Impossible of HD ➂ Error Type ➃ Data analyzed by NEC Engineers ➄ Error Drive 1: 11XX XXXX XXXX 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000 ➀ ➁ ➂ ➃ ➄ 4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000 b7 b1 b0 b7 b6 b5 b4 b3 b2 b1 b0 b7 b3 b2 b1 b0 [11H] Program Memory Verification Impossible (HFC Fault) b0: 0/1 = -/HFC 0 b1: 0/1 = -/HFC 1 00H: HD Processing NG 01H: HD Not Connected 02H: HD Busy 03H: HD Fault (Fault processing/Not equipment, etc.) 04H: Transfer NG 05H: Response Timeout b0: 0/1 = -/Drive Number 0 b1: 0/1 = -/Drive Number 1 b2: 0/1 = -/Drive Number 2 b3: 0/1 = -/Drive Number 3
NDA-24238 CHAPTER 3 Page 137 Revision 3.0 SYSTEM MESSAGES [12H] Program Memory Verification Impossible (Fault at CPU side) ➀ Error detection by Routine Diagnosis ➁ Cause for suspension of Program Memory Verification (Error Code) 1: 12XX 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000 ➀ ➁ 4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000 b7 b1 b0 [12H] Program Memory Verification Impossible (Fault at CPU side) 01H: CPU-to-CPU communication failed 02H: Check sum file copy failed
CHAPTER 3 NDA-24238 Page 138 Revision 3.0 SYSTEM MESSAGES [20H] Data Memory Verification Discrepancy ➀ Error detection by Routine Diagnosis ➁ Verification of HFC ➂ Verification of Data Memory ➃ Data analyzed by NEC Engineers 1: 20XX XX00 XXXX XXXX 2: XXXX XXXX XXXX XXXX 3: 0000 0000 0000 0000 ➀ ➁ ➂ ➃ 4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000 b7 b1 b0 b7 b2 b1 b0 [20H] Data Memory Verification Discrepancy b0: 0/1 = -/HFC 0 is normal b1: 0/1 = -/HFC 1 is normal b0: 0/1 = -/Present Data Memory (DM) b1: 0/1 = -/Local Data Memory (LDM) b2: 0/1 = -/Network Data Memory (NDM)
NDA-24238 CHAPTER 3 Page 139 Revision 3.0 SYSTEM MESSAGES [21H] Data Memory Verification Impossible (HFC Fault) ➀ Error detection by Routine Diagnosis ➁ HFC Impossible Verification ➂ Verification of Data Memory ➃ Error Type ➄ Single Code DM LDM NDM 1: 21XX XX00 XXXX XXXX 2: XXXX XXXX XXXX XXXX 3: 0000 0000 0000 0000 ➀ ➁ ➂ ➃ ➄ ➅ ➆ ➃ ➄ ➅ ➆ ➃ ➄ ➅ ➆ 4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000 b7 b1 b0 b7 b2 b1 b0 b7 b6 b5 b4 b3 b2 b1 b0 b7 b6 b5 b4 b3 b2 b1 b0 [21H] Data Memory Verification Impossible (HFC Fault) b0: 0/1 = -/HFC 0 is abnormal b1: 0/1 = -/HFC 1 is abnormal b0: 0/1 = -/Data Memory (DM) b1: 0/1 = -/Local Data Memory (LDM) b2: 0/1 = -/Network Data Memory (NDM) 00H: HD Processing NG 01H: HD Not Connected 02H: HD Busy 03H: HD Fault (Fault processing/Not equipment etc.) 04H: Transfer NG 05H: Response Timeout 51H: Data Transfer starts 53H: File Transfer starts 55H: Data Load
CHAPTER 3 NDA-24238 Page 140 Revision 3.0 SYSTEM MESSAGES ➅ Data analyzed by NEC Engineers ➆ Error Drive Note:When ➃ (Error Type) is 00H, ➄ Signal Code, ➅ and ➆ Error Drive are valid. b7 b3 b2 b1 b0 b0: 0/1 = -/Drive Number 0 b1: 0/1 = -/Drive Number 1 b2: 0/1 = -/Drive Number 2 b3: 0/1 = -/Drive Number 3
NDA-24238 CHAPTER 3 Page 141 Revision 3.0 SYSTEM MESSAGES [30H] TSW ACT/STBY Changeover Failure ➀ Detected Error Item ➁ Active TSW No. ➂-➅ MUX card (ACT-side) linkage condition 1: 30XX XXXX XXXX XXXX 2: XXXX 0000 0000 0000 3: 0000 0000 0000 0000 ➀ ➁ ➂ ➃ ➄ ➅ ➆ ➇ ➈ ➉ 4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000 b7 b0 b7 b6 b5 b4 b3 b2 b1 b0 b7 b6 b5 b4 b3 b2 b1 b0 ➂Unit 3 Unit 2 Unit 1 Unit 0 Unit 3 Unit 2 Unit 1 Unit 0 0: - 1: MUX connection error (functional fault/not mounted) MG1 MG0 ➃Unit 3 Unit 2 Unit 1 Unit 0 Unit 3 Unit 2 Unit 1 Unit 0 MG3 MG2 ➄Unit 3 Unit 2 Unit 1 Unit 0 Unit 3 Unit 2 Unit 1 Unit 0 MG5 MG4 ➅Unit 3 Unit 2 Unit 1 Unit 0 Unit 3 Unit 2 Unit 1 Unit 0 MG7 MG6 [30H] TSW ACT/STBY Changeover Failure b0: 0/1=TSW #0 is ACT/#1 is ACT As shown in the following table, each bit represents the Unit No. allocated for each MUX card in position. When “1” is set, the corresponding MUX card (status: ACT) has a functional failure or is not mounted in the proper location.
CHAPTER 3 NDA-24238 Page 142 Revision 3.0 SYSTEM MESSAGES ➆-➉ MUX card (STBY) linkage condition b7 b6 b5 b4 b3 b2 b1 b0 b7 b6 b5 b4 b3 b2 b1 b0 ➆Unit 3 Unit 2 Unit 1 Unit 0 Unit 3 Unit 2 Unit 1 Unit 0 0: - 1: MUX connection error (functional fault/not mounted) MG1 MG0 ➇Unit 3 Unit 2 Unit 1 Unit 0 Unit 3 Unit 2 Unit 1 Unit 0 MG3 MG2 ➈Unit 3 Unit 2 Unit 1 Unit 0 Unit 3 Unit 2 Unit 1 Unit 0 MG5 MG4 ➉Unit 3 Unit 2 Unit 1 Unit 0 Unit 3 Unit 2 Unit 1 Unit 0 MG7 MG6 As shown in the following table, each bit represents the Unit No. allocated for each MUX card in position. When “1” is set, the corresponding MUX card (status: STBY) has a functional failure or is not mounted in the proper location.
NDA-24238 CHAPTER 3 Page 143 Revision 3.0 SYSTEM MESSAGES [31H] TSW ACT/STBY Changeover Failure (MUX Fault) ➀ Detected Error Item ➁ Active TSW No. ➂-➅ MUX card (ACT-side) linkage condition 1: 30XX XXXX XXXX XXXX 2: XXXX 0000 0000 0000 3: 0000 0000 0000 0000 ➀ ➁ ➂ ➃ ➄ ➅ ➆ ➇ ➈ ➉ 4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000 b7 b0 b7 b6 b5 b4 b3 b2 b1 b0 b7 b6 b5 b4 b3 b2 b1 b0 ➂Unit 3 Unit 2 Unit 1 Unit 0 Unit 3 Unit 2 Unit 1 Unit 0 0: - 1: MUX connection error (functional fault/not mounted) MG1 MG0 ➃Unit 3 Unit 2 Unit 1 Unit 0 Unit 3 Unit 2 Unit 1 Unit 0 MG3 MG2 ➄Unit 3 Unit 2 Unit 1 Unit 0 Unit 3 Unit 2 Unit 1 Unit 0 MG5 MG4 ➅Unit 3 Unit 2 Unit 1 Unit 0 Unit 3 Unit 2 Unit 1 Unit 0 MG7 MG6 [31H] TSW ACT/STBY Changeover Failure (MUX Fault) b0: 0/1=TSW #0 is ACT/#1 is ACT As shown in the following table, each bit represents the Unit No. allocated for each MUX card in position. When “1” is set, the corresponding MUX card (status: ACT) has a functional failure or is not mounted in the proper location.