    							CHAPTER 3 NDA-24238
    Page 134
    Revision 3.0
    SYSTEM MESSAGES
    In a specific time cycle, the system allows a routine diagnosis in its hardware and software to determine if they
    are operating properly. This message indicates that the system has been checked by the routine diagnosis pro-
    gram and the result of the diagnosis is not normal.
    ➀ Detected Error Item
    Note:The data in this area will be diverse, according to the diagnosis specified in ➀. For details on each
    item data, see the following pages.
    1: XXXX XXXX XXXX XXXX 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    Note
    ➀ 
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b7 b6 b5 b4 b3 b2 b1 b0
    Default Alarm:
    NON7-PCyclic Diagnosis Information (Error Detected)Default Grade:
    3Grade Modified: Lamp Modified:
    [10H] Program Memory Verification Discrepancy
    [11H] Program Memory Verification Impossible (HFD Fault)
    [12H] Program Memory Verification Impossible (Fault at CPU side)
    [20H] Data Memory Verification Discrepancy
    [21H] Data Memory Verification Impossible (HFD Fault)
    [30H] TSW ACT/STBY Changeover Failure
    [31H] TSW ACT/STBY Changeover Failure (MUX Fault)
    [41H] CPU ACT/STBY Changeover Failure (Single CPU System)
    [42H] CPU ACT/STBY Changeover Failure (DM Verification NG)
    [43H] CPU ACT/STBY Changeover Failure (PCI Fault)
    [44H] CPU ACT/STBY Changeover Failure (Changeover NG or CPU 
    RAM Copy NG)
    [50H] Trunk Ineffective Hold Detected
    [51H] Trunk Ineffective Hold Detected and Released
    [52H] Trunk Ineffective Hold Detected Impossible
    [70H] Call Forwarding Memory Clear NG
    [A0H] Periodic Backup Abnormal End
    [C0H] Detection of Remaining Link Abnormal End
    (for Release 4 or later) 
    						
    							NDA-24238 CHAPTER 3
    Page 135
    Revision 3.0
    SYSTEM MESSAGES
    [10H] Program Memory Verification Discrepancy 
    ➀ Error detection by Routine 
    Diagnosis
    ➁ Verification of HFD number
    ➂ Verification of Drive Number
    ➃ Data analyzed by NEC Engineers
    1: 1000 XXXX XXXX XXXX 2: XXXX 0000 0000 0000 3: 0000 0000 0000 0000
    ➀ ➁ ➂ ➃
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b7 b1 b0
    b7 b3 b2 b1 b0
    [10H] Program Memory Verification Discrepancy
    b0: 0/1 = -/HFD 0
    b1: 0/1 = -/HFD 1
    b0: 0/1 = -/Drive Number 0
    b1: 0/1 = -/Drive Number 1
    b2: 0/1 = -/Drive Number 2
    b3: 0/1 = -/Drive Number 3 
    						
    							CHAPTER 3 NDA-24238
    Page 136
    Revision 3.0
    SYSTEM MESSAGES
    [11H] Program Memory Verification Impossible (HFD Fault)
    ➀ Error detection by Routine 
    Diagnosis
    ➁ Verification Impossible of HD
    ➂ Error Type
    ➃ Data analyzed by NEC Engineers
    ➄ Error Drive
    1: 11XX XXXX XXXX 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀ ➁
    ➂  ➃ ➄
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b7 b1 b0
    b7 b6 b5 b4 b3 b2 b1 b0
    b7 b3 b2 b1 b0
    [11H] Program Memory Verification Impossible (HFC Fault)
    b0: 0/1 = -/HFC 0
    b1: 0/1 = -/HFC 1
    00H: HD Processing NG
    01H: HD Not Connected
    02H: HD Busy
    03H: HD Fault (Fault processing/Not equipment, etc.)
    04H: Transfer NG
    05H: Response Timeout
    b0: 0/1 = -/Drive Number 0
    b1: 0/1 = -/Drive Number 1
    b2: 0/1 = -/Drive Number 2
    b3: 0/1 = -/Drive Number 3 
    						
    							NDA-24238 CHAPTER 3
    Page 137
    Revision 3.0
    SYSTEM MESSAGES
    [12H] Program Memory Verification Impossible (Fault at CPU side)
    ➀ Error detection by Routine 
    Diagnosis
    ➁ Cause for suspension of Program 
    Memory Verification (Error Code)
    1: 12XX 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀ ➁
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b7 b1 b0
    [12H] Program Memory Verification Impossible (Fault at CPU side)
    01H: CPU-to-CPU communication failed
    02H: Check sum file copy failed 
    						
    							CHAPTER 3 NDA-24238
    Page 138
    Revision 3.0
    SYSTEM MESSAGES
    [20H] Data Memory Verification Discrepancy
    ➀ Error detection by Routine 
    Diagnosis
    ➁ Verification of HFC
    ➂ Verification of Data Memory
    ➃ Data analyzed by NEC Engineers
    1: 20XX XX00 XXXX XXXX 2: XXXX XXXX XXXX XXXX 3: 0000 0000 0000 0000
    ➀ ➁ ➂
    ➃
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b7 b1 b0
    b7 b2 b1 b0
    [20H] Data Memory Verification Discrepancy
    b0: 0/1 = -/HFC 0 is normal
    b1: 0/1 = -/HFC 1 is normal
    b0: 0/1 = -/Present Data Memory (DM)
    b1: 0/1 = -/Local Data Memory (LDM)
    b2: 0/1 = -/Network Data Memory (NDM) 
    						
    							NDA-24238 CHAPTER 3
    Page 139
    Revision 3.0
    SYSTEM MESSAGES
    [21H] Data Memory Verification Impossible (HFC Fault)
    ➀ Error detection by Routine 
    Diagnosis
    ➁ HFC Impossible Verification
    ➂ Verification of Data Memory
    ➃ Error Type
    ➄ Single Code
    DM LDM NDM
    1: 21XX XX00 XXXX XXXX 2: XXXX XXXX XXXX XXXX 3: 0000 0000 0000 0000
    ➀ ➁ ➂ ➃ ➄ ➅ ➆ ➃ ➄ ➅ ➆ ➃ ➄ ➅ ➆
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b7 b1 b0
    b7 b2 b1 b0
    b7 b6 b5 b4 b3 b2 b1 b0
    b7 b6 b5 b4 b3 b2 b1 b0
    [21H] Data Memory Verification Impossible (HFC Fault)
    b0: 0/1 = -/HFC 0 is abnormal
    b1: 0/1 = -/HFC 1 is abnormal
    b0: 0/1 = -/Data Memory (DM)
    b1: 0/1 = -/Local Data Memory (LDM)
    b2: 0/1 = -/Network Data Memory (NDM)
    00H: HD Processing NG
    01H: HD Not Connected
    02H: HD Busy
    03H: HD Fault (Fault processing/Not equipment etc.)
    04H: Transfer NG
    05H: Response Timeout
    51H: Data Transfer starts
    53H: File Transfer starts
    55H: Data Load 
    						
    							CHAPTER 3 NDA-24238
    Page 140
    Revision 3.0
    SYSTEM MESSAGES
    ➅ Data analyzed by NEC Engineers
    ➆ Error Drive
    Note:When ➃ (Error Type) is 00H, ➄ Signal Code, ➅ and ➆ Error Drive are valid. b7 b3 b2 b1 b0
    b0: 0/1 = -/Drive Number 0
    b1: 0/1 = -/Drive Number 1
    b2: 0/1 = -/Drive Number 2
    b3: 0/1 = -/Drive Number 3 
    						
    							NDA-24238 CHAPTER 3
    Page 141
    Revision 3.0
    SYSTEM MESSAGES
    [30H] TSW ACT/STBY Changeover Failure 
    ➀ Detected Error Item
    ➁ Active TSW No.
    ➂-➅ MUX card (ACT-side) linkage 
    condition
    1: 30XX XXXX XXXX XXXX 2: XXXX 0000 0000 0000 3: 0000 0000 0000 0000
    ➀ ➁ ➂ ➃ ➄ ➅ ➆ ➇ ➈ ➉
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b7 b0
    b7 b6 b5 b4 b3 b2 b1 b0
    b7 b6 b5 b4 b3 b2 b1 b0
    ➂Unit 3 Unit 2  Unit 1  Unit 0 Unit 3 Unit 2  Unit 1  Unit  0
    0: -
    1: MUX connection error 
    (functional fault/not 
    mounted) MG1
    MG0
    ➃Unit 3 Unit 2  Unit 1  Unit 0 Unit 3 Unit 2  Unit 1  Unit  0
    MG3
    MG2
    ➄Unit 3 Unit 2  Unit 1  Unit 0 Unit 3 Unit 2  Unit 1  Unit  0
    MG5
    MG4
    ➅Unit 3 Unit 2  Unit 1  Unit 0 Unit 3 Unit 2  Unit 1  Unit  0
    MG7
    MG6
    [30H] TSW ACT/STBY Changeover Failure
    b0: 0/1=TSW #0 is ACT/#1 is ACT
    As shown in the following table, each bit represents the Unit No. allocated 
    for each MUX card in position. When “1” is set, the corresponding MUX 
    card (status: ACT) has a functional failure or is not mounted in the proper 
    location. 
    						
    							CHAPTER 3 NDA-24238
    Page 142
    Revision 3.0
    SYSTEM MESSAGES
    ➆-➉ MUX card (STBY) linkage 
    condition
    b7 b6 b5 b4 b3 b2 b1 b0
    b7 b6 b5 b4 b3 b2 b1 b0
    ➆Unit 3 Unit 2  Unit 1  Unit 0 Unit 3 Unit 2  Unit 1  Unit  0
    0: -
    1: MUX connection error 
    (functional fault/not 
    mounted) MG1
    MG0
    ➇Unit 3 Unit 2  Unit 1  Unit 0 Unit 3 Unit 2  Unit 1  Unit  0
    MG3
    MG2
    ➈Unit 3 Unit 2  Unit 1  Unit 0 Unit 3 Unit 2  Unit 1  Unit  0
    MG5
    MG4
    ➉Unit 3 Unit 2  Unit 1  Unit 0 Unit 3 Unit 2  Unit 1  Unit  0
    MG7
    MG6
    As shown in the following table, each bit represents the Unit No. allocated 
    for each MUX card in position. When “1” is set, the corresponding MUX 
    card (status: STBY) has a functional failure or is not mounted in the proper 
    location. 
    						
    							NDA-24238 CHAPTER 3
    Page 143
    Revision 3.0
    SYSTEM MESSAGES
    [31H] TSW ACT/STBY Changeover Failure (MUX Fault)
    ➀ Detected Error Item
    ➁ Active TSW No.
    ➂-➅ MUX card (ACT-side) linkage 
    condition
    1: 30XX XXXX XXXX XXXX 2: XXXX 0000 0000 0000 3: 0000 0000 0000 0000
    ➀ ➁ ➂ ➃ ➄ ➅ ➆ ➇ ➈ ➉
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b7 b0
    b7 b6 b5 b4 b3 b2 b1 b0
    b7 b6 b5 b4 b3 b2 b1 b0
    ➂Unit 3 Unit 2  Unit 1  Unit 0 Unit 3 Unit 2  Unit 1  Unit  0
    0: -
    1: MUX connection error 
    (functional fault/not 
    mounted) MG1
    MG0
    ➃Unit 3 Unit 2  Unit 1  Unit 0 Unit 3 Unit 2  Unit 1  Unit  0
    MG3
    MG2
    ➄Unit 3 Unit 2  Unit 1  Unit 0 Unit 3 Unit 2  Unit 1  Unit  0
    MG5
    MG4
    ➅Unit 3 Unit 2  Unit 1  Unit 0 Unit 3 Unit 2  Unit 1  Unit  0
    MG7
    MG6
    [31H] TSW ACT/STBY Changeover Failure (MUX Fault)
    b0: 0/1=TSW #0 is ACT/#1 is ACT
    As shown in the following table, each bit represents the Unit No. allocated 
    for each MUX card in position. When “1” is set, the corresponding MUX 
    card (status: ACT) has a functional failure or is not mounted in the proper 
    location. 
    						