CHAPTER 3 NDA-24238 Pag e 4 4 Revision 3.0 SYSTEM MESSAGES This message displays when a fault has occurred to the clock oscillator in the CPU. ➀ Self-CPU Restart Information ➁ Male-CPU Restart Information (FF H: not mounted) ➂ Related Call Information Reference: See Chapter 5, Section 6.2, for the repair procedure. 1: XXXX XX00 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000 ➀ ➁➂ 4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000 b7 b5 b4 b3 b0 b7 b5 b4 b3 b0 b7 b0 Default Alarm: MN0-DCPU Clock DownDefault Grade: 3Grade Modified: Lamp Modified: b0: 0/1=-/Monitor Restart b3: 0/1=-/Initialization b4: 0/1=Data Copy restart (for Dual-CPU system only) b5: 0/1=-/MB control b7: 0/1=ACT/STBY (active system indication after restart) b0: 0/1=-/Monitor Restart b3: 0/1=-/Initialization b4: 0/1=-/Data Copy restart (for Dual-CPU system only) b5: 0/1=-/MB control b7: 0/1=ACT/STBY (active system indication after restart) b7: 0/1=Released/Not released
NDA-24238 CHAPTER 3 Page 45 Revision 3.0 SYSTEM MESSAGES C-level infinite loop is a state where a clock-level program, running under clock interrupt disable state, is in an infinite loop. This message displays when the counter value to check the normality of the processing has become abnormal. ➀ Self-CPU Restart Information after clock fault occurrence ➁ Mate-CPU Restart Information ➂ NMI Factor Reference: See Chapter 5, Section 6.2, for the repair procedure. 0-E C-level Infinite Loop 1: XXXX XXXX XXXX XXXX 2: XXXX XXXX XXXX XXXX 3: XXXX XXXX XXXX XXXX ➀ ➁ ➂ ➃ ➄ ➅ ➆ ➇ 4: XXXX XXXX XXXX XXXX 5: XXXX XXXX XXXX XXXX 6: XXXX XXXX XXXX XXXX ➇ 7: XXXX XXXX XXXX XXXX 8: XX00 0000 0000 0000 9: 0000 0000 0000 0000 ➇ b7 b5 b4 b3 b0 b7 b5 b4 b3 b0 b7 b6 b5 b4 b3 b2 b1 b0 Default Alarm: SUP0-EC-Level Infinite LoopDefault Grade: 2Grade Modified: Lamp Modified: b0: 0/1 = -/Monitor Restart b3: 0/1 = -/Initialization b4: 0/1 = -/Data Copy Restart (for Dual-CPU system only) b5: 0/1 = -/MBcontrol b7: 0/1 = ACT/STBY (active system indication after restart) b0: 0/1 = -/Monitor Restart b3: 0/1 = -/Initialization b4: 0/1 = -/Data Copy Restart (for Dual-CPU system only) b5: 0/1 = -/MBcontrol b7: 0/1 = ACT/STBY (active system indication after restart) b0: 0/1 = -/Reset by Power On b1: 0/1 = -/Watchdog Timer timeout b2: 0/1 = ISAGT is mounted/ISGAT is not mounted b3: 0/1 = -/OSC clock interrupt on ISGAT b4: 0/1 = -/IO parity Alarm b5: 0/1 = -/IO ready Alarm b6: 0/1 = -/External NMI
CHAPTER 3 NDA-24238 Pag e 4 6 Revision 3.0 SYSTEM MESSAGES ➃ System Controlling Port B ➄ CPU Alarm ➅ CPU Changeover Factors ➆ System ALM ➇ Data Analyzed by NEC Engineers b7 b6 b5 b4 b3 b2 b1 b0 b7 b6 b5 b4 b3 b2 b1 b0 b7 b6 b5 b4 b3 b2 b1 b0 b7 b6 b5 b4 b3 b2 b1 b0 b0: 0/1 = Timer 2 Gate ON/OFF b1: 0/1 = Speaker Gate ON/OFF b2: 0/1 = Parity Check Enable/MASK b3: 0/1 = Channel Check Enable/MASK b4: 0/1 = -/RAM Refresh Pulse Output State b5: 0/1 = -/Timer 2 Output State b6: 0/1 = -/Channel Check Error Detected b7: 0/1 = -/Parity Error Detected b0: 0/1 = -/ACT-side Processor CLK Alarm b1: 0/1 = -/ACT-side Processor COP Alarm b2: 0/1 = -/ACT-side Processor MEM Alarm b3: 0/1 = -/ACT-side Processor Emergency Timer Overflow b4: 0/1 = -/STBY-side Processor CLK Alarm b5: 0/1 = -/STBY-side Processor COP Alarm b6: 0/1 = -/STBY-side Processor MEM Alarm b7: 0/1 = -/STBY-side Processor Emergency Timer Overflow b0: 0/1 = -/CLK Alarm b1: 0/1 = -/Emergency Timer Overflow b2: 0/1 = -/SOFT EMA b3: 0/1 = -/SOFT changeover b4: 0/1 = -/Emergency Counter Overflow b5: 0/1 = STBY/ACT b6: 0/1 = Dual/Single b7: 0/1 = CPU #0/CPU#1 b0: 0/1 = -/Main Power Alarm b1: 0/1 = -/Power Alarm b2: 0/1 = -/FUSE Alarm b3: 0/1 = -/TEMP MJ Alarm b4: 0/1 = -/TEMP MN Alarm b5: 0/1 = -/Parity Alarm b6: 0/1 = Card is not mounted/mounted b7: 0/1 = -/EMA CLK Alarm
NDA-24238 CHAPTER 3 Page 47 Revision 3.0 SYSTEM MESSAGES This message displays when a CPU memory read/write error occurs. ➀Information on Self-CPU Restart after detection of a clock fault ➁ Mate-CPU Restart Information ➂ NMI Factor Reference: See Chapter 5, Section 6.2, for the repair procedure. 0-F Memory Failure 1: XXXX XXXX XXXX XXXX 2: XXXX XXXX XXXX XXXX 3: XXXX XXXX XXXX XXXX ➀ ➁ ➂ ➃ ➄ ➅ ➆ ➇ 4: XXXX XXXX XXXX XXXX 5: XXXX XXXX XXXX XXXX 6: XXXX XXXX XXXX XXXX ➇ 7: XXXX XXXX XXXX XXXX 8: XX00 0000 0000 0000 9: 0000 0000 0000 0000 ➇ b7 b5 b4 b3 b0 b7 b5 b4 b3 b0 b7 b6 b5 b4 b3 b2 b1 b0 Default Alarm: SUP0-FMemory FailureDefault Grade: 3Grade Modified: Lamp Modified: b0: 0/1 = -/Monitor Restart b3: 0/1 = -/Initialization b4: 0/1 = -/Data Copy Restart (for Dual-CPU system only) b5: 0/1 = -/MBcontrol b7: 0/1 = ACT/STBY (active system indication after restart) b0: 0/1 = -/Monitor Restart b3: 0/1 = -/Initialization b4: 0/1 = -/Data Copy Restart (for Dual-CPU system only) b5: 0/1 = -/MBcontrol b7: 0/1 = ACT/STBY (active system indication after restart) b0: 0/1 = -/Reset by Power On b1: 0/1 = -/Watchdog Timer timeout b2: 0/1 = ISGAT is mounted/ISGAT is not mounted b3: 0/1 = -/OSC clock interrupt on ISGAT b4: 0/1 = -/IO parity Alarm b5: 0/1 = -/IO ready Alarm b6: 0/1 = -/External NMI
CHAPTER 3 NDA-24238 Pag e 4 8 Revision 3.0 SYSTEM MESSAGES ➃ System Controlling Port B ➄ CPU Alarm ➅ CPU Changeover Factors ➆ System ALM ➇ Data Analyzed by NEC Engineers b7 b6 b5 b4 b3 b2 b1 b0 b7 b6 b5 b4 b3 b2 b1 b0 b7 b6 b5 b4 b3 b2 b1 b0 b7 b6 b5 b4 b3 b2 b1 b0 b0: 0/1 = Timer 2 Gate ON/OFF b1: 0/1 = Speaker Gate ON/OFF b2: 0/1 = Parity Check Enable/MASK b3: 0/1 = Channel Check Enable/MASK b4: 0/1 = -/RAM Refresh Pulse Output State b5: 0/1 = -/Timer 2 Output State b6: 0/1 = -/Channel Check Error Detected b7: 0/1 = -/Parity Error Detected b0: 0/1 = -/ACT-side Processor CLK Alarm b1: 0/1 = -/ACT-side Processor COP Alarm b2: 0/1 = -/ACT-side Processor MEM Alarm b3: 0/1 = -/ACT-side Processor Emergency Timer Overflow b4: 0/1 = -/STBY-side Processor CLK Alarm b5: 0/1 = -/STBY-side Processor COP Alarm b6: 0/1 = -/STBY-side Processor MEM Alarm b7: 0/1 = -/STBY-side Processor Emergency Timer Overflow b0: 0/1 = -/CLK Alarm b1: 0/1 = -/Emergency Timer Overflow b2: 0/1 = -/SOFT EMA b3: 0/1 = -/SOFT changeover b4: 0/1 = -/Emergency Counter Overflow b5: 0/1 = STBY/ACT b6: 0/1 = Dual/Single b7: 0/1 = CPU #0/CPU #1 b0: 0/1 = -/Main Power Alarm b1: 0/1 = -/Power Alarm b2: 0/1 = -/FUSE Alarm b3: 0/1 = -/TEMP MJ Alarm b4: 0/1 = -/TEMP MN Alarm b5: 0/1 = -/Parity Alarm b6: 0/1 = Card is not mounted/mounted b7: 0/1 = -/EMA CLK Alarm
NDA-24238 CHAPTER 3 Page 49 Revision 3.0 SYSTEM MESSAGES This message displays when a B-level infinite loop failure occurs. ➀Information on Self-CPU Restart after detection of a clock fault ➁ Mate-CPU Restart Information ➂ B-level Infinite Loop ➃ Data Analyzed by NEC Engineers Reference: See Chapter 5, Section 6.2, for the repair procedure. 0-F Memory Failure 1: XXXX XXXX XXXX XXXX 2: XXXX XXXX XXXX XXXX 3: XXXX XXXX XXXX XXXX ➀ ➁➂ ➃ 4: XXXX XXXX XXXX XXXX 5: XXXX XXXX XXXX XXXX 6: XXXX XXXX XXXX XXXX ➃ 7: XXXX XXXX XXXX XXXX 8: XX00 0000 0000 0000 9: 0000 0000 0000 0000 ➃ b7 b5 b4 b3 b0 b7 b5 b4 b3 b0 b7 b1 b0 Default Alarm: MN0-GB1-Level Infinite Loop (Permanent)Default Grade: 2Grade Modified: Lamp Modified: b0: 0/1 = -/Monitor Restart b3: 0/1 = -/Initialization b4: 0/1 = -/Data Copy restart (for Dual-CPU system only) b5: 0/1 = -/MB control b7: 0/1 = ACT/STBY (active system indication after restart) b0: 0/1 = -/Monitor Restart b3: 0/1 = -/Initialization b4: 0/1 = -/Data Copy Restart (for Dual-CPU system only) b5: 0/1 = -/MBcontrol b7: 0/1 = ACT/STBY (active system indication after restart) b0: 0/1 = -/B-level Infinite Loop b1: 0/1 = -/Task Timer Timeout
CHAPTER 3 NDA-24238 Pag e 5 0 Revision 3.0 SYSTEM MESSAGES This message displays when, in the CPU program processing, the counter value to check the normality of the processing has become abnormal. ➀ Self-CPU Restart Information ➁ Mate-CPU Restart Information (FF H: not mounted) ➂ ➃ Data Analyzed by NEC Engineers Reference: See Chapter 5, Section 6.2 and Section 6.3, for the repair procedure. 1: XXXX XXXX XXXX XXXX 2: XXXX XXXX XXXX XXXX 3: XXXX XXXX XXXX XXXX ➀ ➁ ➂ ➃ ➃ ➃ 4: XXXX XXXX XXXX XXXX 5: XXXX XXXX XXXX XXXX 6: XXXX XXXX XXXX XXXX ➃➃➃ 7: XXXX XXXX XXXX XXXX 8: XX00 0000 0000 0000 9: 0000 0000 0000 0000 ➃➃ b7 b5 b4 b3 b0 b7 b5 b4 b3 b0 b7 b1 b0 Default Alarm: SUP0-HB1-Level Infinite Loop (Temporary)Default Grade: 1Grade Modified: Lamp Modified: b0: 0/1 = -/Monitor Restart b3: 0/1 = -/Initialization b4: 0/1 = -/Data Copy restart (for Dual-CPU system only) b5: 0/1 = -/MB control b7: 0/1 = ACT/STBY (active system indication after restart) b0: 0/1 = -/Monitor Restart b3: 0/1 = -/Initialization b4: 0/1 = -/Data Copy restart (for Dual-CPU system only) b5: 0/1 = -/MB control b7: 0/1 = ACT/STBY (active system indication after restart) b0: 0/1 = -/B-level Infinite Loop b1: 0/1 = -/Task Timer Timeout
NDA-24238 CHAPTER 3 Page 51 Revision 3.0 SYSTEM MESSAGES This message displays when a fault, such as the Clock down or C-level infinite loop error, has occurred. ➀ Mate-CPU Restart Information Reference: See Chapter 5, Section 6.2 and Section 6.3, for the repair procedure. 1: XX00 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000 ➀ 4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000 b7 b3 b2 b1 b0 Default Alarm: SUP0-IMate CPU FailureDefault Grade: 3Grade Modified: Lamp Modified: b0: 0/1 = -/CPU clock down b1: 0/1 = -/C-level infinite loop b2: 0/1 = -/Memory error, Parity alarm b3: 0/1 = -/Emergency Timer Overflow
CHAPTER 3 NDA-24238 Pag e 5 2 Revision 3.0 SYSTEM MESSAGES This message displays when the system is interrupting abnormally in the processing. ➀ Self-CPU Restart Information ➁ Mate-CPU Restart Information (FF H: not mounted) ➂ ➃ Data Analyzed by NEC Engineers Reference: See Chapter 5, Section 6.2 and Section 6.3, for the repair procedure. 1: XXXX XXXX XXXX XXXX 2: XXXX XXXX XXXX XXXX 3: XXXX XXXX XXXX XXXX ➀ ➁ ➂ ➃ ➃ ➃ ➃ 4: XXXX XXXX XXXX XXXX 5: XXXX XXXX XXXX XXXX 6: XXXX XXXX XXXX XXXX ➃➃➃ 7: XXXX XXXX XXXX XXXX 8: XX00 0000 0000 0000 9: 0000 0000 0000 0000 ➃➃ b7 b5 b4 b3 b0 b7 b5 b4 b3 b0 b7 b3 b0 Default Alarm: SUP0-JAbnormal InterruptDefault Grade: 2Grade Modified: Lamp Modified: b0: 0/1 = -/Monitor Restart b3: 0/1 = -/Initialization b4: 0/1 = -/Data Copy restart (for Dual-CPU system only) b5: 0/1 = -/MB control b7: 0/1 = ACT/STBY (active system indication after restart) b0: 0/1 = -/Monitor Restart b3: 0/1 = -/Initialization b4: 0/1 = -/Data Copy restart (for Dual-CPU system only) b5: 0/1 = -/MB control b7: 0/1 = ACT/STBY (active system indication after restart) b0: 0/1 = -/Abnormal Interruption (Hardware) b3: 0/1 = -/Program Exception
NDA-24238 CHAPTER 3 Page 53 Revision 3.0 SYSTEM MESSAGES This message displays when link information cannot be written into the switch memory of the TSW in both systems. ➀TSW system in which a fault is detected ➁ Status at the time of fault detection ➂ Data Analyzed by NEC Engineers Reference: See Chapter 5, Section 5.3, for the repair procedure. 1: XXXX XXXX XXXX XXXX 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000 ➀ ➁ ➂ 4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000 b7 b0 b7 b6 b0 Default Alarm: MN1-ABoth TSW Failure (Permanent)Default Grade: 3Grade Modified: Lamp Modified: b0: 0/1 = TSW No. 0/TSW No. 1 b0: 0/1 = TSW No. 0 system/TSW No. 1 system b6: Speech Path in ACT status 0/1 = No. 0 system/No. 1 system