    							CHAPTER 3 NDA-24238
    Pag e 4 4
    Revision 3.0
    SYSTEM MESSAGES
    This message displays when a fault has occurred to the clock oscillator in the CPU.
    ➀ Self-CPU Restart Information
    ➁ Male-CPU Restart Information (FF 
    H: not mounted)
    ➂ Related Call Information
    Reference: See Chapter 5, Section 6.2, for the repair procedure.
    1: XXXX XX00 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀ ➁➂
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b7 b5 b4 b3 b0
    b7 b5 b4 b3 b0
    b7 b0
    Default Alarm:
    MN0-DCPU Clock DownDefault Grade:
    3Grade Modified: Lamp Modified:
    b0: 0/1=-/Monitor Restart
    b3: 0/1=-/Initialization
    b4: 0/1=Data Copy restart (for Dual-CPU system only)
    b5: 0/1=-/MB control
    b7: 0/1=ACT/STBY (active system indication after restart)
    b0: 0/1=-/Monitor Restart
    b3: 0/1=-/Initialization
    b4: 0/1=-/Data Copy restart (for Dual-CPU system only)
    b5: 0/1=-/MB control
    b7: 0/1=ACT/STBY (active system indication after restart)
    b7: 0/1=Released/Not released 
    						
    							NDA-24238 CHAPTER 3
    Page 45
    Revision 3.0
    SYSTEM MESSAGES
    C-level infinite loop is a state where a clock-level program, running under clock interrupt disable state, is in
    an infinite loop. This message displays when the counter value to check the normality of the processing has
    become abnormal.
    ➀ Self-CPU Restart Information after 
    clock fault occurrence
    ➁ Mate-CPU Restart Information
    ➂ NMI Factor
    Reference: See Chapter 5, Section 6.2, for the repair procedure.
    0-E C-level Infinite Loop
    1: XXXX XXXX XXXX XXXX 2: XXXX XXXX XXXX XXXX 3: XXXX XXXX XXXX XXXX
     
    ➀ ➁ ➂ ➃ ➄ ➅ ➆
    ➇
    4: XXXX XXXX XXXX XXXX 5: XXXX XXXX XXXX XXXX 6: XXXX XXXX XXXX XXXX
    ➇
    7: XXXX XXXX XXXX XXXX 8: XX00 0000 0000 0000 9: 0000 0000 0000 0000
    ➇
    b7 b5 b4 b3 b0
    b7 b5 b4 b3 b0
    b7 b6 b5 b4 b3 b2 b1 b0
    Default Alarm:
    SUP0-EC-Level Infinite LoopDefault Grade:
    2Grade Modified: Lamp Modified:
    b0: 0/1 = -/Monitor Restart
    b3: 0/1 = -/Initialization
    b4: 0/1 = -/Data Copy Restart (for Dual-CPU system only)
    b5: 0/1 = -/MBcontrol
    b7: 0/1 = ACT/STBY (active system indication after restart)
    b0: 0/1 = -/Monitor Restart
    b3: 0/1 = -/Initialization
    b4: 0/1 = -/Data Copy Restart (for Dual-CPU system only)
    b5: 0/1 = -/MBcontrol
    b7: 0/1 = ACT/STBY (active system indication after restart)
    b0: 0/1 = -/Reset by Power On
    b1: 0/1 = -/Watchdog Timer timeout
    b2: 0/1 = ISAGT is mounted/ISGAT is not mounted
    b3: 0/1 = -/OSC clock interrupt on ISGAT
    b4: 0/1 = -/IO parity Alarm
    b5: 0/1 = -/IO ready Alarm
    b6: 0/1 = -/External NMI 
    						
    							CHAPTER 3 NDA-24238
    Pag e 4 6
    Revision 3.0
    SYSTEM MESSAGES
    ➃ System Controlling Port B
    ➄ CPU Alarm
    ➅ CPU Changeover Factors
    ➆ System ALM
    ➇ Data Analyzed by NEC Engineers b7 b6 b5 b4 b3 b2 b1 b0
    b7 b6 b5 b4 b3 b2 b1 b0
    b7 b6 b5 b4 b3 b2 b1 b0
    b7 b6 b5 b4 b3 b2 b1 b0
    b0: 0/1 = Timer 2 Gate ON/OFF
    b1: 0/1 = Speaker Gate ON/OFF
    b2: 0/1 = Parity Check Enable/MASK
    b3: 0/1 = Channel Check Enable/MASK
    b4: 0/1 = -/RAM Refresh Pulse Output State
    b5: 0/1 = -/Timer 2 Output State
    b6: 0/1 = -/Channel Check Error Detected
    b7: 0/1 = -/Parity Error Detected
    b0: 0/1 = -/ACT-side Processor CLK Alarm
    b1: 0/1 = -/ACT-side Processor COP Alarm
    b2: 0/1 = -/ACT-side Processor MEM Alarm
    b3: 0/1 = -/ACT-side Processor Emergency Timer Overflow
    b4: 0/1 = -/STBY-side Processor CLK Alarm
    b5: 0/1 = -/STBY-side Processor COP Alarm
    b6: 0/1 = -/STBY-side Processor MEM Alarm
    b7: 0/1 = -/STBY-side Processor Emergency Timer Overflow
    b0: 0/1 = -/CLK Alarm
    b1: 0/1 = -/Emergency Timer Overflow
    b2: 0/1 = -/SOFT EMA
    b3: 0/1 = -/SOFT changeover
    b4: 0/1 = -/Emergency Counter Overflow
    b5: 0/1 = STBY/ACT
    b6: 0/1 = Dual/Single
    b7: 0/1 = CPU #0/CPU#1
    b0: 0/1 = -/Main Power Alarm
    b1: 0/1 = -/Power Alarm
    b2: 0/1 = -/FUSE Alarm
    b3: 0/1 = -/TEMP MJ Alarm
    b4: 0/1 = -/TEMP MN Alarm
    b5: 0/1 = -/Parity Alarm
    b6: 0/1 = Card is not mounted/mounted
    b7: 0/1 = -/EMA CLK Alarm 
    						
    							NDA-24238 CHAPTER 3
    Page 47
    Revision 3.0
    SYSTEM MESSAGES
    This message displays when a CPU memory read/write error occurs.
    ➀Information on Self-CPU Restart 
    after detection of a clock fault
    ➁ Mate-CPU Restart Information
    ➂ NMI Factor
    Reference: See Chapter 5, Section 6.2, for the repair procedure.
    0-F Memory Failure
    1: XXXX XXXX XXXX XXXX 2: XXXX XXXX XXXX XXXX 3: XXXX XXXX XXXX XXXX
     
    ➀ ➁ ➂ ➃ ➄ ➅ ➆
    ➇
    4: XXXX XXXX XXXX XXXX 5: XXXX XXXX XXXX XXXX 6: XXXX XXXX XXXX XXXX
    ➇
    7: XXXX XXXX XXXX XXXX 8: XX00 0000 0000 0000 9: 0000 0000 0000 0000
    ➇
    b7 b5 b4 b3 b0
    b7 b5 b4 b3 b0
    b7 b6 b5 b4 b3 b2 b1 b0
    Default Alarm:
    SUP0-FMemory FailureDefault Grade:
    3Grade Modified: Lamp Modified:
    b0: 0/1 = -/Monitor Restart
    b3: 0/1 = -/Initialization
    b4: 0/1 = -/Data Copy Restart (for Dual-CPU system only)
    b5: 0/1 = -/MBcontrol
    b7: 0/1 = ACT/STBY (active system indication after restart)
    b0: 0/1 = -/Monitor Restart
    b3: 0/1 = -/Initialization
    b4: 0/1 = -/Data Copy Restart (for Dual-CPU system only)
    b5: 0/1 = -/MBcontrol
    b7: 0/1 = ACT/STBY (active system indication after restart)
    b0: 0/1 = -/Reset by Power On
    b1: 0/1 = -/Watchdog Timer timeout
    b2: 0/1 = ISGAT is mounted/ISGAT is not mounted
    b3: 0/1 = -/OSC clock interrupt on ISGAT
    b4: 0/1 = -/IO parity Alarm
    b5: 0/1 = -/IO ready Alarm
    b6: 0/1 = -/External NMI 
    						
    							CHAPTER 3 NDA-24238
    Pag e 4 8
    Revision 3.0
    SYSTEM MESSAGES
    ➃ System Controlling Port B
    ➄ CPU Alarm
    ➅ CPU Changeover Factors
    ➆ System ALM
    ➇ Data Analyzed by NEC Engineers b7 b6 b5 b4 b3 b2 b1 b0
    b7 b6 b5 b4 b3 b2 b1 b0
    b7 b6 b5 b4 b3 b2 b1 b0
    b7 b6 b5 b4 b3 b2 b1 b0
    b0: 0/1 = Timer 2 Gate ON/OFF
    b1: 0/1 = Speaker Gate ON/OFF
    b2: 0/1 = Parity Check Enable/MASK
    b3: 0/1 = Channel Check Enable/MASK
    b4: 0/1 = -/RAM Refresh Pulse Output State
    b5: 0/1 = -/Timer 2 Output State
    b6: 0/1 = -/Channel Check Error Detected
    b7: 0/1 = -/Parity Error Detected
    b0: 0/1 = -/ACT-side Processor CLK Alarm
    b1: 0/1 = -/ACT-side Processor COP Alarm
    b2: 0/1 = -/ACT-side Processor MEM Alarm
    b3: 0/1 = -/ACT-side Processor Emergency Timer Overflow
    b4: 0/1 = -/STBY-side Processor CLK Alarm
    b5: 0/1 = -/STBY-side Processor COP Alarm
    b6: 0/1 = -/STBY-side Processor MEM Alarm
    b7: 0/1 = -/STBY-side Processor Emergency Timer Overflow
    b0: 0/1 = -/CLK Alarm
    b1: 0/1 = -/Emergency Timer Overflow
    b2: 0/1 = -/SOFT EMA
    b3: 0/1 = -/SOFT changeover
    b4: 0/1 = -/Emergency Counter Overflow
    b5: 0/1 = STBY/ACT
    b6: 0/1 = Dual/Single
    b7: 0/1 = CPU #0/CPU #1
    b0: 0/1 = -/Main Power Alarm
    b1: 0/1 = -/Power Alarm
    b2: 0/1 = -/FUSE Alarm
    b3: 0/1 = -/TEMP MJ Alarm
    b4: 0/1 = -/TEMP MN Alarm
    b5: 0/1 = -/Parity Alarm
    b6: 0/1 = Card is not mounted/mounted
    b7: 0/1 = -/EMA CLK Alarm 
    						
    							NDA-24238 CHAPTER 3
    Page 49
    Revision 3.0
    SYSTEM MESSAGES
    This message displays when a B-level infinite loop failure occurs.
    ➀Information on Self-CPU Restart 
    after detection of a clock fault
    ➁ Mate-CPU Restart Information
    ➂ B-level Infinite Loop
    ➃ Data Analyzed by NEC Engineers
    Reference: See Chapter 5, Section 6.2, for the repair procedure.
    0-F Memory Failure
    1: XXXX XXXX XXXX XXXX 2: XXXX XXXX XXXX XXXX 3: XXXX XXXX XXXX XXXX
    ➀ ➁➂ 
    ➃
    4: XXXX XXXX XXXX XXXX 5: XXXX XXXX XXXX XXXX 6: XXXX XXXX XXXX XXXX
    ➃
    7: XXXX XXXX XXXX XXXX 8: XX00 0000 0000 0000 9: 0000 0000 0000 0000
    ➃
    b7 b5 b4 b3 b0
    b7 b5 b4 b3 b0
    b7 b1 b0
    Default Alarm:
    MN0-GB1-Level Infinite Loop (Permanent)Default Grade:
    2Grade Modified: Lamp Modified:
    b0: 0/1 = -/Monitor Restart
    b3: 0/1 = -/Initialization
    b4: 0/1 = -/Data Copy restart (for Dual-CPU system only)
    b5: 0/1 = -/MB control
    b7: 0/1 = ACT/STBY (active system indication after restart)
    b0: 0/1 = -/Monitor Restart
    b3: 0/1 = -/Initialization
    b4: 0/1 = -/Data Copy Restart (for Dual-CPU system only)
    b5: 0/1 = -/MBcontrol
    b7: 0/1 = ACT/STBY (active system indication after restart)
    b0: 0/1 = -/B-level Infinite Loop
    b1: 0/1 = -/Task Timer Timeout 
    						
    							CHAPTER 3 NDA-24238
    Pag e 5 0
    Revision 3.0
    SYSTEM MESSAGES
    This message displays when, in the CPU program processing, the counter value to check the normality of the
    processing has become abnormal.
    ➀ Self-CPU Restart Information
    ➁ Mate-CPU Restart Information (FF 
    H: not mounted)
    ➂
    ➃
     Data Analyzed by NEC Engineers
    Reference: See Chapter 5, Section 6.2 and Section 6.3, for the repair procedure.
    1: XXXX XXXX XXXX XXXX 2: XXXX XXXX XXXX XXXX 3: XXXX XXXX XXXX XXXX
    ➀ ➁ ➂ ➃ ➃ ➃
    4: XXXX XXXX XXXX XXXX 5: XXXX XXXX XXXX XXXX 6: XXXX XXXX XXXX XXXX
    ➃➃➃
    7: XXXX XXXX XXXX XXXX 8: XX00 0000 0000 0000 9: 0000 0000 0000 0000
    ➃➃
    b7 b5 b4 b3 b0
    b7 b5 b4 b3 b0
    b7 b1 b0
    Default Alarm:
    SUP0-HB1-Level Infinite Loop (Temporary)Default Grade:
    1Grade Modified: Lamp Modified:
    b0: 0/1 = -/Monitor Restart
    b3: 0/1 = -/Initialization
    b4: 0/1 = -/Data Copy restart (for Dual-CPU system only)
    b5: 0/1 = -/MB control
    b7: 0/1 = ACT/STBY (active system indication after restart)
    b0: 0/1 = -/Monitor Restart
    b3: 0/1 = -/Initialization
    b4: 0/1 = -/Data Copy restart (for Dual-CPU system only)
    b5: 0/1 = -/MB control
    b7: 0/1 = ACT/STBY (active system indication after restart)
    b0: 0/1 = -/B-level Infinite Loop
    b1: 0/1 = -/Task Timer Timeout 
    						
    							NDA-24238 CHAPTER 3
    Page 51
    Revision 3.0
    SYSTEM MESSAGES
    This message displays when a fault, such as the Clock down or C-level infinite loop error, has occurred.
    ➀ Mate-CPU Restart Information
    Reference: See Chapter 5, Section 6.2 and Section 6.3, for the repair procedure.
    1: XX00 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀ 
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b7 b3 b2 b1 b0
    Default Alarm:
    SUP0-IMate CPU FailureDefault Grade:
    3Grade Modified: Lamp Modified:
    b0: 0/1 = -/CPU clock down
    b1: 0/1 = -/C-level infinite loop
    b2: 0/1 = -/Memory error, Parity alarm
    b3: 0/1 = -/Emergency Timer Overflow 
    						
    							CHAPTER 3 NDA-24238
    Pag e 5 2
    Revision 3.0
    SYSTEM MESSAGES
    This message displays when the system is interrupting abnormally in the processing.
    ➀ Self-CPU Restart Information
    ➁ Mate-CPU Restart Information (FF 
    H: not mounted)
    ➂
    ➃
     Data Analyzed by NEC Engineers
    Reference: See Chapter 5, Section 6.2 and Section 6.3, for the repair procedure.
    1: XXXX XXXX XXXX XXXX 2: XXXX XXXX XXXX XXXX 3: XXXX XXXX XXXX XXXX
    ➀ ➁ ➂ ➃ ➃ ➃ ➃
    4: XXXX XXXX XXXX XXXX 5: XXXX XXXX XXXX XXXX 6: XXXX XXXX XXXX XXXX
    ➃➃➃
    7: XXXX XXXX XXXX XXXX 8: XX00 0000 0000 0000 9: 0000 0000 0000 0000
    ➃➃
    b7 b5 b4 b3 b0
    b7 b5 b4 b3 b0
    b7 b3 b0
    Default Alarm:
    SUP0-JAbnormal InterruptDefault Grade:
    2Grade Modified: Lamp Modified:
    b0: 0/1 = -/Monitor Restart
    b3: 0/1 = -/Initialization
    b4: 0/1 = -/Data Copy restart (for Dual-CPU system only)
    b5: 0/1 = -/MB control
    b7: 0/1 = ACT/STBY (active system indication after restart)
    b0: 0/1 = -/Monitor Restart
    b3: 0/1 = -/Initialization
    b4: 0/1 = -/Data Copy restart (for Dual-CPU system only)
    b5: 0/1 = -/MB control
    b7: 0/1 = ACT/STBY (active system indication after restart)
    b0: 0/1 = -/Abnormal Interruption (Hardware)
    b3: 0/1 = -/Program Exception 
    						
    							NDA-24238 CHAPTER 3
    Page 53
    Revision 3.0
    SYSTEM MESSAGES
    This message displays when link information cannot be written into the switch memory of the TSW in both
    systems.
    ➀TSW system in which a fault is 
    detected
    ➁ Status at the time of fault detection
    ➂ Data Analyzed by NEC Engineers
    Reference: See Chapter 5, Section 5.3, for the repair procedure.
    1: XXXX XXXX XXXX XXXX 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀ ➁ ➂
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b7 b0
    b7 b6 b0
    Default Alarm:
    MN1-ABoth TSW Failure (Permanent)Default Grade:
    3Grade Modified: Lamp Modified:
    b0: 0/1 = TSW No. 0/TSW No. 1
    b0: 0/1 = TSW No. 0 system/TSW No. 1 system
    b6: Speech Path in ACT status
    0/1 = No. 0 system/No. 1 system 
    						