    							CHAPTER 3 NDA-24238
    Pag e 9 4
    Revision 3.0
    SYSTEM MESSAGES
    When type of connection is ACD Trunk connection
    ➁ ACD Trouble Kind
    Note 1:When “(ACD Trouble Kind)” is 01 Hex:
    ➂-➅ Information on Calling Party
    (a) Station (b) Trunk
    My Line No. Route No. + Trunk No.
    ➆ ➇ Not Used
    ➈ ➉  Information on Calling Party
    Refer to 
    ➂~➅
    Information on Held Party or 3rd Station/Trunk in 3-Party Connection
    Refer to 
    ➂~➅
    Note 2:When “(ACD Trouble Kind)” is 14 Hex:
    ➂ Issue of ACDP (First digit of decimal place)
    ➃ Issue of ACDP (Second digit of decimal place)
    Note 3:When “(ACD Trouble Kind)” is 21 Hex:
    ➂~➅  Information on Calling Party
    Refer to 
    ➂~➅ of Note 1
    ➆ ➇Not used
    ➈ ➉Information on Unknown Pilot No.
    Refer to 
    ➂~➅, (a) Station of Note 1 b7 b6 b5 b4 b3 b2 b1 b0
    b4-b7b0-b3
    ➂DC0 DC1
    ➃DC2 DC3
    ➄DC4 DC5
    ➅
    b0-b7: ACD trouble kind
    01H=ACD trunk trouble key Note 1
    14H=ACD reset start Note 2
    15H=Insufficient ACD memory
    16H=Insufficient ACD call record
    17H=Excessive business station on ACD calls
    18H=Excessive calls queued
    21H=Unknown Pilot No. called Note 3
    24H=Illegal execution of ACD timeout procedure Note 4
    30H=ACD pointer error detection and recovery Note 5
    33H=ACDP reset completion Note 6
    34H=Call recovery failure on unknown Pilot No. Note 7
    37H=ACD Traffic (incoming) Capacity Over
    99H=Illegal ACD processing-trace stored Note 4
    b4-b7b0-b3
    ➂DC0
    ➃DC1 DC2
    ➄DC0
    ➅DC1 DC2
    Route No.
    Trunk No.
    Example:RT125,TKl0
    01 25 00 l0
     
    ➂➃➄➅
    1112 
    						
    							NDA-24238 CHAPTER 3
    Page 95
    Revision 3.0
    SYSTEM MESSAGES
    Note 4:
    When “(ACD Trouble Kind)” is 24 or 99 Hex:
    ➂~➅Not used
    ➆ ➇Error Counter
    Note 5:When “(ACD Trouble Kind)” is 30 Hex:
    ➂~➅Pointer Address
    ➆Not used
    ➇Error Kind
    Note 6:When “(ACD Trouble Kind)” is 33 Hex:
    ➂ACDP Data Memory
    00 = Used
    01 = Not used
    ➃ACDP System Capacity
    02 = 50 Agent Positions
    04 = 200 Agent Positions
    07 = 500 Agent Positions
    12 = 900 Agent Positions
    15 = 2,000 Agent Positions
    Note:If other data is output, the ACD system may not be working correctly. In this case, be sure to install the
    ACD application again by using the MSVIP command.
    Note 7:When “(ACD Trouble Kind)” is 34 Hex:
    ➂~➅Information on Unknown Pilot No.
    Refer to 
    ➂~➅, (a) Station of Note 1
    Note 
    						
    							CHAPTER 3 NDA-24238
    Pag e 9 6
    Revision 3.0
    SYSTEM MESSAGES
    This message displays to indicate the result of a designated connection test (Individual Trunk Access) from a
    station.
    ➀Test Item (b0-b3 is valid only for 
    Outgoing trunk test)
    1: XXXX XXXX XXXX XXXX 2: XXXX 00XX XXXX XXXX 3: XXXX XXXX XXXX XXXX
    ➀ ➁ ➂ ➃ ➄ ➅ ➆ ➇ ➈ ➉
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b7 b6 b5 b4 b3 b2 b1 b0
    Default Alarm:
    NON6-ISTA-Test Connection DataDefault Grade:
    3Grade Modified: Lamp Modified:
    11121212121212
    b0-b2: Kind of Signal
    2 = Second Dial Tone
    6 = Sender (Delay Dial Start)
    7 = Sender (Wink Start)
    b3: 0/1 = Data is invalid/valid
    b4-b7: Test item
    1 = Outgoing Trunk Test
    2 = ORT/IRT Test
    3 = Sender Test
    4 = Digital Conference
    5  =  To n e  Te s t
    6 = Ringing Signal test
    0 = Test NG 
    						
    							NDA-24238 CHAPTER 3
    Page 97
    Revision 3.0
    SYSTEM MESSAGES
    ➁ 
    ➂-➄ Station number of testing station 
    (see table)
    ➅ Te n a n t  N o .
    ➆ OPTN data b7 b6 b5 b4 b3 b2 b1 b0
    b7 b3 b2 b1 b0
    b7 b3 b2 b1 b0
    b0-b3: Number of digits of the testing station No.
    b4-b7: Error Numbers (see table below)
    Error Numbers and Their Meanings
    ERROR NO. MEANING
    0---
    1 The testing station is restricted from activating the service.
    2 Route Number Error of the designated trunk
    3 Trunk Number Error of the designated trunk
    4 Trunk busy
    5Sender busy
    6 SMDR failure
    7 Call origination restriction
    8 Register busy
    9 Trunk Number Error - when the trunk has been designated 
    by SHF.
    A Trunk busy - when the trunk has been designated by SHF.
    B Inter-digit timer expiration
    C Register or sender is defective with respect to DP, DP/PB
    D Register of sender is faulty with respect to PB
    E Tone fault
    F Test Processing Error
    b4-b7 b0-b3
    ➂DC0 DC1
    ➃DC2 DC3
    ➄DC4 DC5
    b0-b3: Tenant No. (1-15)
    b7: OP
    0/1 = Data in OPTN ( )
     is invalid/valid➆
    b0-b3: Tenant No. (Over 15) 
    						
    							CHAPTER 3 NDA-24238
    Pag e 9 8
    Revision 3.0
    SYSTEM MESSAGES
    ➇ Tested Route No.
    Note:When Logical Routes are assigned, Logical Route Numbers are displayed here.
    ➈ OPRT data
    Note:When Logical Routes are assigned, Logical Route Numbers are displayed here.
    ➉ (This data is not for Ringing Signal 
    Te s t )
    Digit of Dialed Number (for test
    )
    Dialed Number (for test)
    (a) Dialed Number sent by the test Trunk/Sender b7 b6 b5 b4 b3 b2 b1 b0
    b7 b6 b5 b4 b3 b2 b1 b0
    b7 b6 b5 b4 b3 b2 b1 b0
    b7 b4 b3 b2 b1 b0
    b7 b6 b5 b4 b3 b2 b1 b0
    b4-b7b0-b3b4-b7b0-b3
    dc0 dc1 dc12 dc13
    dc2 dc3 dc14 dc15
    dc4 dc5 dc16 dc17
    dc6 dc7 dc18 dc19
    dc8 dc9 dc20 dc21
    dc10 dc11
    b0-b5: Route No. (1-63) Note
    b6: OP
    0/1 = Data in OPRT ( 
    ➈ ) is invalid/valid
    b7: AC
    0/1 = Internal trunk/External trunk
    b0-b7: Route No. ( 
     64) Note>
    b0-b7: Trunk No. for Outgoing trunk test, ORT/IRT Test, Sender Test and 
    Digital Conference test
    To n e  S l o t  N o .  f o r  To n e  Te s t
    0 = DT 1 = SPDT
    2 = RBT 3 = CRBT, CWT
    4 = BT 5 = RBT
    6 = SST, WT 7 = SDT
    8 = TRG 9 = SDTT
    10 = CWRBT 14 = MSC
    b0-b4: Dialed number digit sent by the test Trunk/Sender
    or
    Dialed Number digit received by the test Register
    11
    12
    (b) Dial Number received by the test Register
    b4-b7b0-b3
    dc0 dc1
    dc2 dc3
    dc4 dc5
    dc6 dc7
    dc8 dc9
    dc10 dc11 
    						
    							NDA-24238 CHAPTER 3
    Page 99
    Revision 3.0
    SYSTEM MESSAGES
    This message displays when a call terminates to the Emergency Telephone.
    ➀ - ➅ Called Station (Emergency 
    Telephone) No. (ASCII Code)
    ➆ -   Calling Station No. (ASCII 
    Code)
    1: XXXX XXXX XXXX XXXX 2: XXXX XXXX 0000 0000 3: 0000 0000 0000 0000
    ➀ ➁ ➂ ➃ ➄ ➅
    ➆  ➇➈ ➉
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b7 b6 b5 b4 b3 b2 b1 b0
    b7 b6 b5 b4 b3 b2 b1 b0
    Default Alarm:
    SUP6-JEmergency CallDefault Grade:
    3Grade Modified: Lamp Modified:
    1112
    ➀DC0 (1st digit)
    ➁DC1 (2nd digit)
    ➂DC2 (3rd digit)
    ➃DC3 (4th digit)
    ➄DC4 (5th digit)
    ➅DC5 (6th digit)
    ➆DC0 (1st digit)
    ➇DC1 (2nd digit)
    ➈DC2 (3rd digit)
    ➉DC3 (4th digit)
    DC4 (5th digit)
    DC5 (6th digit)
    11
    12
    12 
    						
    							CHAPTER 3 NDA-24238
    Page 100
    Revision 3.0
    SYSTEM MESSAGES
    This message displays when the LCR-Attendant Manual Override is set at the Attendant Desk Console.
    ➀ Route Selection Time Pattern No. 
    assigned at Attendant Desk 
    Console
    Note:Route Selection Time Pattern 0-7 corresponds to TDPTN No. 0-7 in the AOPR command.
    1: XX00 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀
     
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b7 b2 b1 b0
    Default Alarm:
    NON6-LEmergency Control StartDefault Grade:
    3Grade Modified: Lamp Modified:
    b0-b2: Pattern No. (1-7) 
    						
    							NDA-24238 CHAPTER 3
    Page 101
    Revision 3.0
    SYSTEM MESSAGES
    This message displays when the LCR-Attendant Manual Override is cancelled at the Attendant Desk Console.
    ➀ Suspension of Emergency Control
    Note:Route Selection Patterns 0-7 corresponds to TDPTN No. 0-7 in the AOPR command.
    1: XX00 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀
     
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b7 b0
    Default Alarm:
    NON6-MEmergency Control StopDefault Grade:
    3Grade Modified: Lamp Modified:
    b0: Fixed 0.
    0 = Outgoing call restriction is released by Attendant Desk Console 
    						
    							CHAPTER 3 NDA-24238
    Page 102
    Revision 3.0
    SYSTEM MESSAGES
    This message displays when the system detects abnormal duration in the line connection between the calling
    and called party. When the calling and called party establish a line connection and continue the hook-up for an
    extremely short or long period of time (predetermined by the ASYD command (SYS1 Index 45, 46)), this mes-
    sage is created.
    ➀ Calling party information
    ➁ Tenant No. of Calling/Called party (Hex.)
    ➂ Calling party Information
    When calling party is Station
    Calling station No. (See table)
    1: XXXX XXXX XXXX XX00 2: XXXX XXXX XXXX XXXX 3: XXXX XXXX XXXX XX00
    ➀ ➁ ➁ ➂ ➂ ➂ ➂  ➃ ➄ ➄ ➄ ➄ ➄ ➄ ➄ ➄ ➄ ➄ ➄ ➄ ➄ ➄ 
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b7 b3 b2 b1 b0
    b7 b3 b2 b1 b0
    Default Alarm:
    NON6-NAbnormal Call Duration DataDefault Grade:
    0Grade Modified: Lamp Modified:
    b0-b3: Type of Calling party
    0 = Station
    1 = Attendant console
    2 = Trunk
    b7: 0/1 = Short/Long Time
    b4-b7b0-b3
    DC0 DC1
    DC2 DC3
    DC4 DC5 
    						
    							NDA-24238 CHAPTER 3
    Page 103
    Revision 3.0
    SYSTEM MESSAGES
    When calling party is ATTCON/DESKCON
    Attendant/Desk console No. (See 
    table.)
    When calling party is Trunk
    Route No. and Trunk No. (See table.)
    Note:
    Route No. (a)
    Route No. (b)
    ➃ Called party information b7 b6 b5 b4 b3 b2 b1 b0
    b7 b6 b5 b4 b3 b2 b1 b0
    b7 b3 b2 b1 b0
    b7 b3 b2 b1 b0
    b4- b7b0-b3
    DC0 DC1
    b0-b7
    (a) Route No. (Hex) Note
    (b) Route No. (Hex) Note
    (c) Trunk No. (Hex) 
    (d) Trunk No. (Hex) 
    b0-b5: Route No. (1-63)
    b6: OP
    0/1 = Data in OPRT is invalid/valid
    b7: AC
    0/1 = Internal trunk/External trunk
    b0-b3: OPRT
    Route No. (Over 64)
    b0-b3:
    00 = Station-to-Station call
    01 = Outgoing call to outside
    02 = Incoming call from outside 
    						